| 1 | PROPOSED CONSTRUCTION OF CLEANING GRADING & FLOUR MILLSHED 106.99 SQ.Mt. |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel, and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation, and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift up to 1.5 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means. |
| 4 | Filling in plinth and floors with approved excavated material in 15cm to 20cm layers, including watering and compacting, etc. Complete. |
| 5 | Filling in plinth and floors with contractor's material/brought from outside and approved by Engineer in charge in layers of 15cm to 20cm including watering and compaction etc. complete. |
| 6 | Providing soling using 80mm size trap metal in 15cm layer including filling voids with crushed sand/grit, ramming, watering, etc. complete. |
| 7 | (P.C.C. ) Providing and laying cast in-situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, and curing complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 8 | (FOOTING CONCRETE ) Providing and laying cast in-situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage, and footings of R.C.C. columns and steel stanchions, etc. including bailing out water, steel centering, formwork, cover blocks, laying/pumping, compaction, and curing, roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 9 | ( COLUMNS CONCRETE )Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided, and curing, etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed, including steel centering, formwork, cover blocks, laying/pumping, compaction, and roughening the surface if special finish is to be provided, and curing, etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor-based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 11 | Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches, etc. as per detailed designs, drawings, and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required, complete. |
| 12 | (Brick Work) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls, including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces, and watering, etc. Complete |
| 13 | ( BRICK WORK ) Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 14 | ( INTERNAL PLASTER ) Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, etc. complete. |
| 15 | ( EXTERNAL PLASTER ) Providing sand-faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag, curing the same for not less than 2 days, and keeping the surface of the base coat rough to receive the sand-faced treatment 6 to 8mm thick in cement mortar 1:4, finishing the surface by taking out grains and curing for fourteen days, scaffolding, etc. Complete. |
| 16 | ( INTERNAL PAINTING WORKS ) Providing and applying white-wash in two coats on old/newplaster do rmasonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 17 | (EXTERNAL PAINTING) Providing and applying plastic emulsion paint of approved quality, colour, and shade to old and new surfaces in two coats, including scaffolding, preparing the surface. (Excluding the primer coat) etc. Complete |
| 18 | (WINDOW) Providing and fixing steel WINDOWS fully glazed, partly fixed as per detailed drawing, with hot-dip zinc coating, including fabricating glazing with plain/obscured glass panes 5mm thick and approved type quality, and iron oxidized fixtures and fastening with guard square bars 12 mm, 10 cm c/c, and oil painting 2 coats, etc. Complete. |
| 19 | Providing Structural Steel work in trusses,other similar trussed purlins and memebers with bracing , gusset plates etc.as per detailed designs and drawings or as directed including cutting , fabricating, hoisting, errecting fixing in position Making riveted / bolted / welded connection and one coat of anticorrosinge paint and over it 2 coats of oil paintin approved quality and shade etc.completed. |
| 20 | Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by engineer incharge with all necessary accessories.(Essar) Make) |
| 21 | Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of2mm thk clear 1.020 mtr wide & 1.7 mtr long. |
| 22 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness, reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with holdfast arrangements, M.S. Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high-grade cast iron or mild steel and one coat of red lead primer, etc. complete. (I.S. 6248-1979) (Without mechanical gear) |
| 23 | Providing & laying in situ cement concrete M-20 Trimix treatment with 100 mm thickness for flooring with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. |
| 24 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) |
| 25 | Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes pro de shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all 26 materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge/ |
| 26 | Roof Gutter (Assumed Girth- 600 mm) PPGI 0.5 mm Thk. Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer in charge |
| 27 | Supply & Fixing of 0.5 mm thk PPGL roof accessories - Center Ridge as per drawing or as directed by engineer incharge-in-completed. |
| 28 | ELECTRICAL |
| 29 | Providing and fixing lioghtening conductor system comprising of erecting Air - Termination consisting of tubular copper rod of 25 mm dia.1.2 mm thick with multiple point shead 1.2mt.long (Heavy Duty)welded or clamped to G.I. pipe pole B grade 50 mm dia of required length with M.S . round base plate 25 Cm diamand 10 mm thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 cm dia m x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cad mium plate nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and G.I. pipe 40 mm dia2 meter length burried in earthing plate remining portion above ground level for watering and refilling comcpete Note-Copper strip from lightening conductor is not considered in this item. |
| 30 | Providing and fixing copper strip 25 mm wide and 3 mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note:- Lightening conductor and earthin pits is not considered in this item. |
| 31 | Supplying and errecting HMS PVC conduit FRLS Grade 25 mm dia. With pvc accessorieson wall/ ceilling as per specification No. WG-MA/ CON |
| 32 | Supplying and errecting mains with 1X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit /trunking / inside pole/ Buss bars or any other places as per specification No. WG-MA/CON |
| 33 | Supplying and errecting mains with 2X1.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Buss bars or any other places as per specification No. WG-MA/CON |
| 34 | Supplying and errecting mains with 2X2.5 sq. mm. FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Buss bars or any other places as per specification No. WG-MA/CON |
| 35 | Supplying and errecting modular type 3pin 6/16 A multy sockets with safety shutter, duly errected on provided plate and box with wiring connections complete |
| 36 | Supplying and errecting PVC surface maodular switch box with double mounting plate for 6 module duly errected |
| 37 | Supplying and errecting PVC surface maodular switch box with double mounting plate for 12 module duly errected |
| 38 | Supplying and errecting street light wall bracket made from 40 mm dia G I pipe 1.2 m in total length complete as per specification no FG- BKT/WB |
| 39 | Supplying, errecting and marking SPMCB 6A to 32 A, C series with rated short circuit braking capasity 10kA in provided distribution board as per specification no SW-SWR/MCB |
| 40 | Providing earthing with galvnised iron earth plate size 60 X 60 C 0.6 cm complete with all materials, testing and recording the resuilt as per specification no EA-Ep |
| 41 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG ODF/FLS2 |
| 42 | ROYALTY CHARGES |
| 43 | Royalty for Sand |
| 44 | Royalty for murum and Other material |
| 45 | QUALITY CONTROL & LAB TESTING |
| 46 | M20 CONCRETE: Mix Design with all tests on basic materials |
| 47 | M20 CONCRETE: Concrete cube compressive strength |
| 48 | M10 CONCRETE: Concrete cube Test |
| 49 | BRICKS : Water Absorption (Set of 5 Bricks), Compressive strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks) |
| 50 | TMT STEEL : Yield Stress, Ultimate Tensile Stress, Elongation, Weight per running meter. |
| 51 | Sand :- i) Fineness Modulus, II) Silt content |
| 52 | Murum :- ii) Atterberg Limit |
| 53 | iii) Density of compacted layer |
| 54 | iv) Proctor Test |
| 55 | Cement Test i) Comprecive strengh ii) Intital and final setting time iii)Spcific Gravity iv) Spicific Gravity v) soundness vi) Finess |
| 56 | Metal Test i) AIV ii) Gradation iii) water Absorbation |
| 57 | Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct Please Enable Macros to View BoQ information |