Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Installation Charges inclusive of Transportation to site and the Bored pile equipment employed for the works including setting up of pile driving equipment with all accessories and tools at each of the pile location based on the sequence of operation approved by the departmental Engineers irrespective of the location and distance involved in movement of pile driving equipment etc., complete. |
| 2 | Installation of Vertical Bored cast in situ RCC piles in all types of soils, using Ready Mix Concrete of M 30 grade, with sulphate resistant Cement, fine aggregate, 20mm and down graded HBGS jelly coarse aggregate. The rate includes welding charges, placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavation of mud pits for circulation of Bentonite solution, closing the mud pits to original level and mud removal with initial lead and lift but excluding dismandeling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing should be as per clause 15.2.2. The length of pile for payment shall be measured upto natural ground level. The work should be carried out as per IS 2911. Pile depth should be decided by the departmental officers at site. |
| 3 | 900 mm dia pile having longitudinal main reinforcement of 12 Nos 20# with helical reinforcement at 12 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with lifting hook of 12 # at required length. (Before 20m) |
| 4 | 450 mm dia pile having longitudinal main reinforcement of 12 Nos 20# with helical reinforcement at 12 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with lifting hook of 12 # at required length.(Before 20m) |
| 5 | 900 mm dia pile having longitudinal main reinforcement of 12 Nos 20# with helical reinforcement at 12 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with lifting hook of 12 # at required length.(After 20m) |
| 6 | 450 mm dia pile having longitudinal main reinforcement of 12 Nos 20# with helical reinforcement at 12 # @ 150mm C/C with inner rings of 12 # @ 1000mm C/C with lifting hook of 12 # at required length.(After 20m) |
| 7 | Initial Load Test as per IS 2911 Part IV 1985 including cost of single pile (250% of pile capacity), labour, reinforcement charges and all other incidential charges including excavation, shoring, strutting, dewatering etc. as necessary hire charges for jacks, measuring devices, Structural Frame work for platform, Kent ledges etc, as required and providing pilecap. |
| 8 | Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete. |
| 9 | Pull out test as per IS 2911 part IV 2013 including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete. |
| 10 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. Data worked out for 48 m3 per day/8 hrs. |
| 11 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting in- clusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. |
| 12 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. |
| 13 | Supplying and filling in foundation, basement, etc with Crushed Stone Sand (M-Sand) in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 14 | Providing, laying, spreading and compacting graded stone aggregates to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers 300mm thick with pavers in sub base/ base course on well prepared surface and compacting with vibratory rollers to achieve the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc complete. |
| 15 | Granular Sub-base with Graded Material (Table:- 400-1) - Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401) - for grading- V Material. |
| 16 | Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification - Mechanical means |
| 17 | Supplying and filling in foundation, basement, etc with stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 18 | Providing pre constructional Anti-termite treatment for the construction of building including cost of chemicals labour as per standard specification. Labour for preparing the area for treatment by spreading chemicals and other incidental charges complete. The rate shall be inclusive of giving anti termite treatment to the building for the following four stages including breaking the termite moulds making holes with crow bars at an interval of 12\\" to a depth of 8\\" in the periphery of the building including flooring area and pouring chemicals etc., complete as per ISI 6313/1981. |
| 19 | Supply and application of of MAPEI's Mapelastic Smart two-component, high flexible, elastic cementitious mortar made from cementitious binders, fine-grained selected aggregates, special admixtures and synthetic polymers in water dispersion with an elongation of 120% (DIN 53504), Static crack bridging ability of >2.5mm (EN 1062-7), Permeability to water vapour sD = 3.6 m, µ = 1800 (EN ISO 7783-1), Impermeability to water < 0.05kg/m²·h0.5 (EN 1062-3), Permeability to CO₂ sDCO2 >50m (EN 1062-6), Reaction to fire (Euroclass): E (EN 13501-1), adhesion to concrete after 28 days: 1.3N/mm² (EN 1542) when applied @ 2mm thickness (in 2 coats) on the surface prepared for waterproofing to be carried out to ensure the mechanical properties of the product. The application of the product shall be carried out after the thorough preparation of the surface which includes cleaning, crack treatment, corner joint treatment, grouting. |
| 20 | Supply and application of MAPEI's Planiseal 88 CE certified ready-to-use, single component, osmotic cementitious mortar suitable for contact with drinking water for waterproofing concrete surfaces by brush or trowel. Apply several criss-cross coats of the product on a clean substrate saturated with water. The product must have the following mechanical characteristics when mixed with 23% water and applied to 2 mm thick. Compressive strength (EN 12190) (MPa): > 25 (after 28 days), Flexural strength (EN 196/1) (MPa): > 6.0 (after 28 days), Adhesion to substrate (EN 1542) (MPa): ≥ 2 (after 28 days), Impermeability expressed as coefficient of permeability to free water (EN 1062-3) (kg/m²•h0.5): W < 0.05 Class III (low permeability to water) according to EN 1062-1, Permeability to water vapour equivalent air thickness SD (EN ISO 7783-1) (m): sD < 1Class I (permeable to water vapour), Reaction to fire (Euroclass): E. Application of the product shall be carried out after all the surfaces and thoroughly prepared free from dust, laitance, dead mortar and any other loose particles that affect the adhesion of the waterproofing mortar from the substrate. |
| 21 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 22 | Supplying and erecting centering for plane surfaces such as RCC Floor / Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting above 3.60m upto 4.90m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m (expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2.40 x 3.0m (expandable upto 4.90m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c and with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 23 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 24 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid) |
| 25 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 26 | Supplying and fixing Kwik stage propping for carrying design load carrying capacity and with stand any side movements of design load with necessary 50mm dia MS pipe cross bracings at spacing each row 1mx1m horizontally and vertically connecting each propping arrangements fully engaged each other with coupler bracings suitably placed at various levels (DOUGLAS) and hSevenths with plywood of 19mm thick board connecting with suitable scaffolding form work like Laced and Braced arrangements as per standard design and as directed by the departmental officers,etc. |
| 27 | Providing and laying in position, Standardised Concrete Mix M-30 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 28 | Foundation & Basement |
| 29 | Providing and laying in position, Standardised Concrete Mix M-40 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 440 kg/m3 and maximum water cement ratio of 0.40, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production,laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 30 | Ground floor |
| 31 | First Floor |
| 32 | Second Floor |
| 33 | Third Floor |
| 34 | Fourth Floor |
| 35 | Fifth Floor |
| 36 | Sixth Floor |
| 37 | Seventh Floor |
| 38 | Eighth Floor |
| 39 | Nineth Floor |
| 40 | Tenth Floor |
| 41 | Eleventh Floor |
| 42 | Twelveth Floor |
| 43 | Thirteenth Floor |
| 44 | Fourteenth Floor |
| 45 | Terrace Floor |
| 46 | Providing and laying in position, Standardised Concrete Mix M-35 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 47 | Ground Floor |
| 48 | Fourteenth floor |
| 49 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 50 | In Foundation and Basement |
| 51 | In Ground Floor |
| 52 | Post Tensioning Work:Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately. |
| 53 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 54 | Foundation and Basement |
| 55 | Ground Floor |
| 56 | First Floor |
| 57 | Second Floor |
| 58 | Third Floor |
| 59 | Fourth Floor |
| 60 | Fifth Floor |
| 61 | Sixth Floor |
| 62 | Seventh Floor |
| 63 | Eighth Floor |
| 64 | Nineth Floor |
| 65 | Tenth Floor |
| 66 | Eleventh Floor |
| 67 | Twelveth Floor |
| 68 | Thirteenth Floor |
| 69 | Fourteenth Floor |
| 70 | Terrace Floor |
| 71 | Brick work in following Cement Mortar using best 1:6 quality Fly ash Brick of size 230x110x70mm with class designation of 12.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 72 | Basement floor |
| 73 | Ground Floor |
| 74 | First Floor |
| 75 | Second Floor |
| 76 | Third Floor |
| 77 | Fourth Floor |
| 78 | Fifth Floor |
| 79 | Sixth Floor |
| 80 | Seventh Floor |
| 81 | Eighth Floor |
| 82 | Nineth Floor |
| 83 | Tenth Floor |
| 84 | Eleventh Floor |
| 85 | Twelveth Floor |
| 86 | Thirteenth Floor |
| 87 | Fourteenth Floor |
| 88 | Terrace Floor |
| 89 | Brick partition walls of 11.00cm thickness using best quality Fly ash bricks of size 230x110x70mm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 90 | Ground Floor |
| 91 | First Floor |
| 92 | Second Floor |
| 93 | Third Floor |
| 94 | Fourth Floor |
| 95 | Fifth Floor |
| 96 | Sixth Floor |
| 97 | Seventh Floor |
| 98 | Eighth Floor |
| 99 | Nineth Floor |
| 100 | Tenth Floor |
| 101 | Eleventh Floor |
| 102 | Twelveth Floor |
| 103 | Thirteenth Floor |
| 104 | Fourteenth Floor |
| 105 | Brick work in following Cement Mortar 1:5 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification. |
| 106 | In Foundation and Basement |
| 107 | In Ground floor |
| 108 | Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete. |
| 109 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 110 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 111 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used, hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 112 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc.,complete. The putty should be got approved by the Executive Engineer before use on work. |
| 113 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 114 | Painting the wall with Texture Finish Paint including labour charges |
| 115 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works) |
| 116 | Treatment to side wall of varying thickness of basement floor, Lift pit, of main building from exterior surface covering the following sequence of operations - Water Proofing: |
| 117 | a) Providing, supplying, mixing, applying two coats of ready to use two component acrylic polymer modified cement based flexible water proofing slurry like TAPECRETE or approved equivalent conforming to IS to thickness of 2 mm on the surface of side wall prior to the chemical injection treatment is completed as specified under item above. |
| 118 | b) Providing, supplying, mixing, laying cement screed plaster 20 mm thick in cement concrete slurry 1:2:4 mixed with 6mm & down grade course graded aggregate with water proofing compound like CICO NO:1 (normal setting integral water proofing compound) or approved equivalent conforming to IS at the rate specified by the manufacturer at any depth & height ove the coated surface of operation (a) above. |
| 119 | Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, shuttering, Nozzles etc. complete as per manufacturer's specification and as directed. |
| 120 | Providing, mixing, laying polymer based water proofing treatment for the Sunken Toilet by applying cement based, flexible, waterproofing compound confirming to IS:2645, to a thickness of 1mm of the prepared surface of the roof slab / floor slab as per specification |
| 121 | Brick Jelly Lime Concrete of 1:2:5 (One Lime,Two Sand and Five Brick jelly ) with 40 mm hand broken brick jelly for Sunken portions including dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification. |
| 122 | Ground Floor |
| 123 | First Floor |
| 124 | Second Floor |
| 125 | Third Floor |
| 126 | Fourth Floor |
| 127 | Fifth Floor |
| 128 | Sixth Floor |
| 129 | Seventh Floor |
| 130 | Eighth Floor |
| 131 | Nineth Floor |
| 132 | Tenth Floor |
| 133 | Eleventh Floor |
| 134 | Twelveth Floor |
| 135 | Thirteenth Floor |
| 136 | Fourteenth Floor |
| 137 | Providing screed concrete for levellling course screed using 6-10 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. - Mechanical Means |
| 138 | Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works). |
| 139 | Paving the floor with best brandaed quality Full body tiles of size 1200 x 600 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 140 | Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 141 | Paving the floor with best approved quality lapato Granite Stone Slabs of size 1200 x 600 of 16 / 18mm thick laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification. |
| 142 | Paving the floor with kotta stone laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and |
| 143 | Paving the floor with best quality (Anti-skid) double charged vitrified Tiles matt finish of size 600 x 600 x 10 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 144 | Dadooing of wall with Special type of ceramic wall tiles of approved quality, colour and design of size 600x600x8mm thick in all floor over a base layer in CM 1:2, (one of cement and two of sand) 10mm thick and laid in situ, in true alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 to suit the colour of the tiles fixed in position with out any air gap in the tiles etc., complete complying with std. specification and as directed bythe deptl. officers. The colour & quality of tiles should be got appd. by the EE before use on work. |
| 145 | Cladding the vertical wall surface with best approved quality fine polished granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick with machine cut edges laid over a cement mortar bed of 10mm thick using cement mortar 1:2 (One cement and two sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 146 | Supplying and cladding 16mm-18mm thick machine mirror polished italian marble slab of approved colour and approved texture to the newly plastered walls or after preparing the existing surface by roughening or hacking the surface, in required position using cement and tile adhesive(diamond star of Bal Endura make or equivalent) mixture grout of average 20mm thick in the ratio 1:2 (tile adhesive shall only be used if marble is to be fixed on existing plastered wall) in proper line and level and filling the joints with roff/balendura make joint filling compound of the same shade of the marble. The rate includes costs of all materials,equipments,labour charges, curing, rubbing, washing, cleaning the site etc. Complete as per instructions of Departmental officers. |
| 147 | Supplying and paving about 16-18mm thick machine mirror polished italian marble slab of approved colour and approved texture in 1:4 cement mortar (One cement and Four M sand) bedding having average thickness upto 75mm in proper line and level including cement slurry with required slope for flooring and filling the joints with Roff/Bal-endura make polymer joint filling compound of the same shade of the marble. The rate shall includes costs of all materials, equipments, labour charges, curing, rubbing, washing, cleaning the surface etc.Complete as per instructions of the departmental officers etc complete. |
| 148 | Providing and fixing of 2mm thick JEOFLOR PREMIUM + Vinyl flooring, 100% recycled flexible homogeneous and monolayer in construction and should be manufactured by calendering & pressing process of size in approved pattern , to ensure a dense , smooth surface and non- directional design , color dyed as a raw mixture to ensure even color throughout the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti- bacterial and Fungicidal properties. The flooring shall incorporates a specially formulated PUR+Surface Treatment and increases the durability of the flooring. It incorporates bacteriostatic and fungistatic actions, tested for Anti - bacterial activity (ISO 22196- >99% inhibit the growth of bacteria) JEOFLOR or Equivalent |
| 149 | Providing granolithic floor finish of 40mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) |
| 150 | Supplying and installation of Anutone/ Topakustiks / Idea Tec / Wood Fit / Equivalent Brand of Acoustic Wooden Wall Panelling with fire retardant grade pine wood fibre slats of size 2430 x 128 x 16mm with lineal perforation of 2mm back lined with soundtex black acoustical fleece 0.27mm thick , 63 g /m2, tongue-groove edge for a seamless look, 5 test fire retardant grade with noise reduction coefficient not less than 0.75 NRC to absorb low and mid range frequencies from 125Hz to 4000Hz. GI strut CC50 frame work not more than 60cm centre to centre using GI channels are fixed on the wall, over which an acoustic filling polywool material sound synth of 500 gsm density of 50mm thick has fixed and finally the panels are fixed and finished, so as to have an neat appearance as directed by the departmental offices. The cost includes cost of material, cost of Labours, scaffolding, transportation, conveyance, etc. complete complying to standard specification. |
| 151 | Providing and Fixing of PVC Trims (Corner beeding) at the outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental engineers at site of work and as per standard specification. |
| 152 | Single nosing to the the granite slabs by cutting the granite slabs for 18mm to 20mm thick edges semicircular shape to required size and nosing with semicircular shape and polishing using hand machine and the nosing is made highly smooth and glossy.The cost includes labour charges and cost cost of machineries and polishing charges,etc.,complete as directed by the departmental officers. |
| 153 | Providing and Fixing of SS corner beading L angle for outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental officers. |
| 154 | Supply and installationi of Anutone (or) Equivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120Kgs/m3, weight 1.8/2.4/3 kg/m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angel with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 Main T wtih flange width 15mm, height 32mm and length 3600mm, , from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel ot the Main T15 to result in 600 x 600mm double. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance etc. complying to standard specification. |
| 155 | Supplying and fixing of Gypsum board false ceiling or equilant using 10mm thick plain board sheets of approved quality and design. The falde ceiling should be suspended from ceiling using 'U' shaped galvanized iron chanels at 1.20m centre to centre on both longitudinal and cross directions.The Gyp board panels are provided as per design/pattern given by the site officer and finishing the ceiling surface with plaster of paris material and including paper tape etc., necessary opening should be made for providing spot lights.Flourescent tubes in the ceiling by covered by using plywood of 12mm thick and the opening should be covered with acrylic panel complying with standard specification and as directed etc., complete and all the materials should be got approved by the Executive Engineer before use on work.The rate is including two coats of plastic emulsion painting over the wall coat primer etc., complete. |
| 156 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated onexternal surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre 'T'. The 'T' shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of 'T' section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of 'T' section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile 'L' Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look |
| 157 | Paving the floor with Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 x 305 x 15mm for Vision Impairment Person laid in cement mortar 1:3 (one cement and three M sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 158 | Supply and fixing Shera Board of natural fibres bonded of Cement Board 6mm thick water resistant with necessary painting and Support materials fixed at all levels, complete complying with standard specification and as directed by the departmental officers,The materials should be got approved by the Executive Engineer before use on works. |
| 159 | Supplying and fixing of GI Metal Single Leaf Door (Duct door) with Insulated PU Adhessive Honeycomb structure infill for stability, door skin In 1 mm Thickness, frame Sheet Thickness 1.2 mm with powder coated of size 1000 X 2100 - Single Leaf Shaft Door - 4 Side Frame including Ball Bearing Butt Hinges (Geze) 4\\"x3\\"x3-3Nos, Shaft lock with Allen key (GEZE)- 1 No, Flush Pull Size: 102X45MM (GEZE)-1 No, Vision Panel-1 No, FIRE RATED Glass Size: 200X300X5mm-1 No, Anchor Bolt-7 Nos of specified Design which is approved by engineering-in-charge etc. complete as per the direction of the departmental officers |
| 160 | Manufactruing, Supplying and fixing of 12 mm thick Toughened glass partition arrangement with the following specification. The outer frame of the glass partition should be made up of Teakwwod scantlings of size 75mm x50mm with ornamental works. The 8mm thick thoughened glass should be sanwitched between two nos of T.W. Scantlings on both sides alround in tact and the beedings should be polished with high quality polish material. The rate includs cost of T.W.Beedings, charges for thoughening the 8mm glass, manufacturing, conveyence of all the materials to the work site, fixing in positition ectc complete as directed by the departmental officers. |
| 161 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) partition using from the profile the size of outer frame 74mm x 60mmx56mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations ree pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the partition. The partition should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. |
| 162 | Supplying and fixing the aluminium anodised fixed glassing 1/3 glazed plus 2/3 prelaminated and partially prelaminated partition using 63.50mm x 38.10mm x 1.50 mm @ 0.818 Kg/cm box section for all members and 5.50mm thick plan glass for pnales. The aluminium frames are at 0.60m c/c in both horizontal and vertical directions with necessary triangle shape glazing clips of 19mm x 17.30mm x 0.75 mm @ 0.124 Kg/cm and the rubber beadings for glass pnales including labour charges for fabrication, conveyance, cost of power consumption charges and dismantling, making holes in R.C.C. / masonry wherever necessary with power drill to the required extent and make good to the original condition after fixing the partition as directed by the departmental officers. |
| 163 | Supplying and fabricating and fixing 45.00 29 in position aluminium anodised partly top 1/2 galzed and partly bottom 1/2 panelled door and frame made out of box section 101.6x44.45x3.18mm thick at 2.319 kg/m door shutter made out of box section 47.1x44.45x2.5mm at 1.202 kg/m for vertical style and top, lock rail sections of size 50x44.50x2.5mm @ 1.292 Kg/m and bottom 100.4x44.45x2.50mm at 1.974kg/m using clips of size 17.15x17.27x1.5mm at 0.176 kg/m with necessary metal screws, rubber beading, strike plate type handle of size 100x30x1.60mm at 0.988 kg/m on both sides, tower bolts, lock pivot arrangements and top 1/2 portion with 5.50 mm thick plain glass and bottom 1/2 portion with one side prelaminated board (MDF) 12mm thick for panel portion with 1 No. of hydraulic door closers of approved quality using aluminium extruded section body tubler type universal with double speed adjustment with ISI monogram including cost - Single Door |
| 164 | UPVC WindowSpecification:(with flymesh and grill)Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (sliding) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 165 | Expansion Joint filling with Polysulphide sealant upto 30mm width - Vertical Providing and laying with two-part elastomeric UV resistant, non-toxic gun grade liquid polysulphide sealant to fill the expansion joint, sealing joints in water retaining structure. The sealant shall have Elongation min. 500% confirms to ASTM D 412, movement accommodation for butt joint 25% & for lap joints 50%. The sealant should meets the requirement of BS 4254 & ISO:12118. Ensure that apply a coat of polysulphide sealant primer @0.5L/m2 to get better adhesion on prepared surface before placing the sealant. The finished cost including surface preparation, filling foam backer rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely asper specification. |
| 166 | Providing expansion joints of 12.50mm wide in RCC floor slab with necessary PVC water stopper of 150mm wide with center bulb and with 4mm to 6mm thickness of approved quality and brand including filling the inner space with suitable non absorbent flexible compressible filler materials of approved quality and brand providing polysulphide sealant of approved quality to a depth of 7.5mm each top and bottom using gun grade qulaity etc., complete and as directed by the deprtmental officers. Rate is inclusive of cost of materails and labours charges for cutting fixing PVC water water stopper, packing materials and poly sulphide sealents etc., as per standard specification. |
| 167 | UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations free pin headed glass 4mm thick should be provided in the louvers. The Ventilator should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 168 | Supplying and fixing of M.S.grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. |
| 169 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 170 | Providing and fixing Glass Reinforced Concrete (G.R.C) ornamental Screens casted with 'Spray Mix' concrete design in approved size, pattern, Thickness (Border 40-50m Thick & Internal Member 25-30mm thick) and shade. The Screens should be made from '53 grade' White Portland Cement' manufactured by 'JK Cement' or 'Birla white', White Quartz fine graded sieve Silica sand, Alkali Resistant Glass Fiber manufactured by 'NEG Japan, Owen corning 'Saint Gobain' or equivalent, Super Plasticizers manufactured by 'Karochem' or equivalent, Polymers manufactured by 'Nova Polychem' or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'Phenochem industries or equivalent. The Screens casting shall take place with layering methodology using-Direct power spray machines. The GRC Screens flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.R should be above or equivalent to 12N/mm2 for tests done on 28 days cured samples. The fixing of Screens should be done using 'Dry fixing' method onto structural support mambers i.e. R.C.C, Brick work or Red oxide primer-paint or Epoxy primer-paint treated mild steel. The fixtures, fasteners and self tapping screws to be used for dry fixing should be of HILTI/KLIMAS/Fischer. The quantity of fasteners or self tapping screws shall be calculated in accordance to the weight of Screens and actual site fixing conditions. If there will be a requirement of Joint filling then Elastometrtic exterior grade paintable PU sealant will be used.For final finishing of Screen one weathershield exterior grade water based diluted paint coat will be done if required. Vendors shall submit shop drawings of the same, the drawings to be duly approved by the engineer incharge at site. The rate is inclusive of scaffolding, filling the gap between the panel and wall surface, saftey net , lifting charges, tools and plants, transportation, taxes etc., complete |
| 171 | Supplying and fixing of Automatic Sliding door High usage frequency.Our doors opens & close at a speed of speed 100-450mm/sec. (adjustable)Heavy duty Top Mounted track with timing beltNo obstruction at the bottomVarious types of Standard & Economical range of panels are available to suite your building structural requirement.Doors can be constructed as partly pre-coated paneled/Aluminium sheets & partly glazing sheet.Automatic Glass Sliding Doors can be constructed with vertical EPDM rubber sealThese doors offer interlocking facility between two doors.The automatic sliding doors can be included with additional safety devices. Actuators such as radar detectors, push buttons, loop detectors or remote control can be added to the control system specified Design which is approved by engineering-in-charge etc. complete as per the direction of the departmental officers |
| 172 | FRAME: Fully Solid Core WPC-100MMX75MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 100mmx75mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member |
| 173 | Supplying and fixing solid core flush shutter 32mm thick with commercial ply on both sides & teak lipping alround and laminated on bothsides with 1 mm thick MICA sheet of approved design with necessary adhesive and C.P.screws, including fixing for aldrop , tower bolt, hinges and lock strike plates , putty, fevical etc., and including the cost of aluminium hinges 125x 30mm size -3 Nos. Antique brass aldrop of size 250x16mm 1No, Antiquebrass tower bolt of size 250x12 mm -1 No. , Antique brass tower bolt of size 200x12mm-1 No, Antique brass door stopper with Nylon bush-1No. shall be provided. All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 microns. The rate is inclusive of cost of fevical, fixing charges, transportation, loading, unloading all other incidental charges and handling charges etc., complete complying with standard specification. |
| 174 | Single Door |
| 175 | Double Door |
| 176 | Supply and fixing in position of ornamental teak wood door frame with shutter of size 4.00m x 2.80m and teak wood scandling superior quality outer frame of size 100 mm x 75 mm and panel shutter of teak wood planks of 30 - 45 cm wide and 25 - 40 mm thick and required hight etc.Rate inclusive of cost of materials for frame, shutter planks, Labour charges frame work, Machine cut of shutter plank with required shape, and nessarry two coat of malamine finish etc.,complete and as directed by the departmental officers. |
| 177 | Supplying and fixing Hydraulic Door Closer of various sizes of approved quality using Aluminium Extruded section body tubuler type universal hydraulic door closer with double speed adjustment like HARDWYN make GAZEL (or) equivalent (with ISI Monogram) |
| 178 | Providing and fixing 2 hr fire rated doubble skin ste door constructed from 1.25mm thick galvanized ste sheet formed to provide a 46mm thick fully flush door shl with lock seam joints at stile edges and the internal construction of the door is a specially designed Honey Comb structure with reinforcements at top, bottom and stile surrounds. As per IS 3614 part-1 & part-2 for stability and integrity and Pressed Galvanized ste confirming to IS 277. |
| 179 | Providing and Fixing, UPVC factory made, white colour sliding Door made of extruded profiles. Sliding frame 60 mm X 62 mm, Sash 66 mm x 42 mm, Bead 16 x 24.5mm. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2±0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8mmx100mm long fasteners, all complete as per direction of Engineer-in-charge. |
| 180 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. |
| 181 | CLEAN ROOM DOORSSupplying and Fixing of double leaf PCGI door with 40mm thick PUF insulation. Door leaf 0.8mm thick. Door profile with powder coated Aluminium. Double glazed vision glass of size 350mmx750mm. Hardwares - SS door handle, automatic door closure and mortice deadlock. |
| 182 | Providing and fixing of 1.2mm thick Lead Lining Door for X-Ray Rooms, Scanning Rooms with Mild Steel Door Frames 105mm x 57mm X 18 G and 12 G x 50mm Shutter made of GI with PWG finish and honey wool insulations with SS 101mm x 75mm x 3mm SS 304 Ball Bearings Butt Hinges, Mortice Sash Lock ML 100A, 50mm BS, 85mm centre, CL 207 : Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make), Heavy Duty Door Closer, Frames fixed wih walls using Mortice Sash Lock ML 100A, 50mm BS, 85mm centre CL207: Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make) all neccesary accessories and fittings as per the required and as per the approval for the Department Officer |
| 183 | Supply & Fixing of 6mm thick (HPL Wall Paneling) Max Compact Interior grade, panels Merino as per ASTM E84 & BS 476 part 7 standards . The panels shall be of standard size with Uni /Nature / Special finish with both side décor, Matt Finish. The Interior panels also should be duromer high-pressure laminates (HPL) as per EN 438-4 type EDF manufactured with norm conformity of EN 438-7 & testing methodoligies as per EN 438-2 standards. The panels Should have Anti Graffiti properties and are Thermally cured High Pressure Laminate Panels. The panels to be fixed to the wall using Profiles which are demountable. which is mounted on the 50 x 25 x 1.50mm powder coated frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights which is fixed to the wall using proper Anchor Fastener required for the Wall base. the profile shall be of 2mm thickness and placed as per the requirement of the Wall surface. The rate is inclusive of all necessary material, labour, and accessories, etc., complete as per Architectural drawing and direction of Engineer-in-charge. |
| 184 | Supplying and fixing in position of 53cm wide Built-in cup-board made of 18mm thick water proof plywood used for rear and sides of cupboard and shutters made of 18mm thick water proof plywood . Inner side to be separated by number of racks with 18mm thick water proof plywood. All the surface is covered with 1.00mm thick mica of approved colour.The shutters are fixed to the frame with required fixtures like aluminium hinges 100x30mm, ornamental handle 100mm, aluminium tower bolts 75x10mm,and cupboard lock, etc., All materials and furniture fittings used on work should be got approved by the Engineer incharge before use. The cost includes cost of all materials labour charges etc., |
| 185 | Suppling and fixing position of polycorbonate sheet (Opaque White) roofing with following specification. The roofing made of 10 mm thick multi wall polycarbonate sheet roofing with following specification. The roofing made of 10mm thick multi wall polycarbonate sheet with approved colour (Lexan branded) double sided UV coated using MS frame work consists of main truss 50 x 50 mm MS square pipe for vertical support in the base plates and top connecting plate for fixing truss. The rate including cost of 10mm thick multi wall polycarbonate sheet, MS truss work, MS vertical support pillars, Horizontal purlins, Aluminium plate for bottom & top with sealent for all joint of sheets and labour charges for all fabrication works and sheet fixing work and necessary Scaffolding cost and painting work for all MS Truss with purlin etc., completed. and as directed by departmental officers. |
| 186 | Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 83mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. |
| 187 | Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sectionsas per the design requirement. Design alculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of5-7 microns or powder coated with pure polyester powderupto 50-60 microns thick. Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 5mm.glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm. Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections. Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonryby using nylon self–expanding cap and driving MS electroplated 80mm long screws into the caps through frames. Glass: 5mm reflective |
| 188 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer |
| 189 | Manufacturing, Supplying and fixing of SPIDER GLAZING which is a complete system for bolted glass structures. This includes 12mm Saint Gobain/eq Toughened glass, fasteners and SPIDER brackets for connection to the framework. The fasteners such as stainless steel Dorma RSF Spider fitting, Stainless steel polished two way spider 90 degree without fin RSF-Fixed bolt for upto 17.52 to 19.52mm facade glass, ULPT 90 single connectors should be used. Adequate door openings should be provided using Dormakaba patch fittings. Top Pivot PT24, Top patch 20, Bottom patch PT 10, Corner US10 and center handle 900mm length and heavy duty floor spring BTS 75, complete door assembly. The glass panes should be designed in order to withstand the wind loads imposed loads and dead loads. .The gap should be maintained between two glass panes in order to avoid brittle failure due to thermal expansion and the provided gap must be sealed using a silicone mastic applied to an extruded silicone seal. the RATE shall include cost of all materials, labour charges and also included charges for redoing the distrubed portion of flooring, etc., complete as directed by the departmental officers. |
| 190 | Providing, assembling and supplying of laminated glass panels for using heat Strengthened clear Glass and toughened glass sandwiched using1.52PVB layer. The Glass of approved colour, size and shape as required shade all complete for the required performance , as directed by the Engineer - in - Charge. The heat strengthened clear glass having properties as U value of 4.20 to 5.50 W/m2 or lower degree K etc., Solar heat gain coefficient less than or equal to 0.35. The sandwich panels shall be assembled in the factory/ workshop of the glass processor. The certificate obtained from approved agency should be produced for heat soak test for clear glass. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. |
| 191 | Providing, assembling and supplying of Single reflective glass panels, 6mm thick heat Strengthened reflective Glass of approved colour, size and shape as required shade with reflective soft coating on surface #2 etc. all complete for the required performance , as directed by the engineer -in - charge. The heat strengthened reflective glass having properties as minimum visible Light transmittance (VLT) of 35-67% or less, Solar heat gain coefficient less than or equal to 0.35-0.5 or less and U value of 5.0-5.6 W/m2 K or lower degree etc. Equivalent SHGC should satisfy the ECBC norms. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. |
| 192 | CURTAIN WORKSupplying and laying polyester, wnShabIe and stainfree cloth (Bio-Active fabric washable gernifreesuitable for dialysis room) curtain system with maximum curtain cloth height 230cm (top 30cm white colour net and 200cm light blue colour as per approval) stitching with stiffenei tape, pleats, ironing ann laying around Each bed using sliding wheels two nylon rollers, nylon axil and tangle free nylon swivel stem with chrome-plated steel hook, curtain track should be supported in roof using 20x20mm, 2mm thick sized aluminium tubes same spec with end caps in two sides using all necessary fittings. as per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour chorges etc. complete.(unpleated length of the cloth measurement will be considered for payinent also the bottoin and top folding will not be consideied in cloth measurement)/ supplying and fixing powder coated 20nam dia. GI round tube lianging support of required length(app. length 1.1Om) one end fixing from slab by using 6inm dia Part bolt at a distance not more than 2in c/c down end fixed to powder costed aluiiiinium channel frame 45 x 20niin x 1mm thick section by using SS screw as per the direction of engineer in chat ge including conveyance. |
| 193 | Providing and fixing of window screen width 100 mm regular quantity made from 100 % polystei/Fibre yarn coated with fade i’esistant polymer to ensure complete opaquely with zeto light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all i‘espect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make- MAC/VISTA/NOVA or any equivalent make. |
| 194 | Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polystei/Fibre yarn coated with fade i’esistant polymer to ensure complete opaquely with zeto light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all i‘espect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make- MAC/VISTA/NOVA or any equivalent make. |
| 195 | Manufacturing, Supplying and Fixing of Stainless Steel Handrails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding,grinding, polishing, conveyance, electrical charges, etc.complete |
| 196 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 197 | Supplying & Fixing of Aluminium Hand Rail vinyl covered box section of size 80-100mm width and 35mm thickness. The box section should be made of Aluminium tubular section with base thickness of 1.5mm and vinyl cover 2mm thickness, the crab band should be fixed on the wall to recommended height of 80cm from finished floor level. The rate inclusive of cost of section labour for fixing and fixtures etc. complete complying with standard specification and as directed by the departmental officers. For Differently Abled Persons |
| 198 | Totem SignageProviding and fixing floor mounted double sided illuminated Totem signs including all operations from fabrication to installation all complete as per relevant image /drawings, detailed technical specification, signage schedule and to the satisfaction of Engineer-incharge. The signage system consisting of sign box made from aluminium modular system with anodized finish of AO 01250/AO 6037 or equivalent of 250mm mill finish complete. Sign box including channel supports shall be anodised coated to match the colour as per drawing and guideline. |
| 199 | Ceiling Suspended Double sided SignageProviding and fixing suspended single sided internally illuminated signs including all operations from fabrication to installation all complete as per relevant image /drawings, detailed technical specifications, signage schedule and to the satisfaction of Engineer -inCharge. The signage system made from aluminium modular system with anodized finish of AO 01250/AO 6037 or equivalent of 250mm mill finish complete. Sign box including channel supports shall be anodised coated to match the colour as per drawing and guideline.Front facia, pictograms and its graphics shall be made up of 4mm thick 040 Acrylic sheet decorated with 3M block out vinyl and approved colour 3M cast Vinyl, design electro cut and pasted on it. Internally illuminated by using LED module GE tetra mini max or equivalent (minimum 50000 hours usage period warranty is must for lighting) with140 degree viewing angle. Internal signs shall be IP52 certified as per approved graphics and fabrication drawing. |
| 200 | Ceiling suspended double side internally illuminated - 600mm x 300mm |
| 201 | Ceiling suspended double side internally illuminated - 1500mm x 300mm |
| 202 | Ceiling suspended double side internally illuminated - 2100mm x 300mm |
| 203 | ENTRANCE BOARDProviding and fixing of titanium gold letters made of 1.2mm thickness front facia & Side beeding 1mm thickness, CNC system channel bending, height 50mm with Reverse LED & SMPS 3mm thick translucent sheet in color as specified, lit internally with Led Modules of Samsung / Osram / Daehans, with requisite Power supply, Breaker and Legrand / L&T Timer mounted on Syntex waterproof junction boxes per attached drawings. System to be designed to with stand design wind pressure of 200Kg/Sqm confirming to IS 875 part 3.Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.Supporting structural steel will be measured under relevant item |
| 204 | Size : Tamil Letters - 18660 mm x 850 mm |
| 205 | Size : English Letters - 16022 mm x 420 mm |
| 206 | Door Signages - Door / Wall MountedSupply and Fixing of Information Signage Board: Pictograms, Front Facia and graphics are to be made up from 5mm thick milky white Acrylic sheet of approved colour and finish, decorated/UV Printed on 3M IJ48C approved colours/Design Cast Vinyl design, electro cut, and pasted on it. The signage shall be fixed to door shutters/ walls/ dado with SS Mirror Screws/3M double sided adhesive tape. |
| 207 | Room designation - 750mm x 200 mm - door mounted / wall mounted above door |
| 208 | Room designation - 600mm x 200 mm - door mounted / wall mounted above door |
| 209 | Room designation - 450mm x 200 mm - door mounted / wall mounted above door |
| 210 | Braille Signage : Room designation - 450mm x 200 mm - door mounted / wall mounted above door |
| 211 | Braille Signage : Room designation - 150mm x 225 mm - door mounted / wall mounted above door. |
| 212 | Lift Directory - Wall Mounted - 900mm x 1200mmProviding and fixing Non - illuminated signs including all operations from fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-in-Charge.>>Sign face: Sign face shall be made in 5 mm thick white acrylic (as specified) having Energy efficient or equivalent self-adhesive cast translucent vinyl of approved colour to be processed in a dust free application room. The translucent film should have clear adhesive. The vinyl thickness should not more than 60 microns without adhesive when measured using IS standard 2508:1984 or ASTM equivalent. The Adhesive of the film should clear and pressure sensitive. The liner of the Film should Synthetic, lay- flat liner that is not affected by water or humidity.The colored vinyl should confirm to class A rating for fire retardant as per ASTM E84 standard - (Standard Test Method for Surface Burning Characteristics of Building Materials) and pass DIN EN 13501-1 (DIN 4102) - (Fire Test to Building Material). The film should also comply to UL746 standard for Polymeric Materials Short Term Property Evaluations.. The films to wrap around the edge of the acrylic to a distance of 25mm on the back side. The sign height shall be equal to the message panel height used i.e. multiple of 255mm. |
| 213 | Supplying and laying red earth, sand and manur mixer as directed by the departmental officer. The proportion of red rod, sand and manure is 1:1:1 and load in layer of 10cm thick in a uniform layer. The cost including cost of all materials, labour for and laying in places as shown by the departmental officer etc complete. |
| 214 | Supplying and laying of korian grass bed over a prepared base including appplication of antitermite chemical like thimpet or purition, neem cake, root regulating fertilizers supply and planing of grass beds cutting the grass to the required or hamental shape etc and carrying out the base management for the turfing for a maintanecne period of three month etc. complete |
| 215 | Supplying, making and Erecting of 5 panelled Multi layer Vertical smart Gardening with variey of colourful plants, the cost including supplying of Plants with required no of wall hanging bio Pots / baskets with potting mix / organic manure. The baskets are fixed double clip hook / hanging arrangements. The vertical garnening should be erected with required water tripping for plants and drain the excess water or cleaning arrangements around gardening. Each panel of garden should have atleast 15 to 20 nos of plants with BIo cups. frame should be made up of coloured powder coated anti corrosive MS angle and hanging wired net .the plants such as crotons, baby tears, dracanea, hosta & Succulents, LIPstick plant, pothos, fern type , bromelids etc should be got approved by Departmental engineer as per standard specification. |
| 216 | Providing SBF Bio-Green Wall Modules/Panels Each 0.3 sqm area with 8 pots (4x2) each pot size 14x7x9 cm With Wall thickness of 2mm)outer wall thickness of 3.5mm and having lock system with panels , provision fir running drip irrigation line on top of panel and drain system for excees water , mounting strip and fixing on ms frame with necessary fixtures etc.,Providing biotechnologically grown plants(syngonium,money plant, ceylon gold, alternanthera and any other suitable indoor/outdoor varieties as directed at site) with thick foliage suitable for vertical / biowall / greenwall structures and filling plant growth media on pots, planting green wall plants on pots and fixing on green wall panels) Plant Choose client Scope.Providing soil less organic growth media with required moisture & nutrients of pH 6.5 - 7.0 and filling growth media on bio - wall pots (160 - 165 pots / sqm and 0.5kg/pot) with necessary geotextile bag and proper drainage of excess water from pots etc., |
| 217 | Charges for Erection and Installation of panel. |
| 218 | Providing and fixing 12mm nominal dia drip irrigation system madewith virgin special grade polyethylene dripper spacing 15cm and having drip punch dia of 2.9mm dia (4LPH) confirm to ISI standard including carriage , fixing at site with all other incedental charges etc., |
| 219 | Supply and fixing of Aluminium Frame work for supporting of vertical garden work, as per detail of the drawing to be given. Rates includes of Material,Labour & Transportation. |
| 220 | Providing and Fixing Water Outlet Drain Line FRB BIO TUB (7''x5\\"Height) |
| 221 | Transportation Charges.. |
| 222 | Supplying and fixing Natural Stone paving of with 18 to 20mm thick necessary raw materials etc., The rate is inclusive of cost of materials, labour charges and transporting etc., complete as directed by the departmental officer. |
| 223 | Supplying and planting Arica Palms as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth Jif any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 224 | Supplying and planting Specimen edge border Plants as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth if any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 225 | Supplying and planting Polyalthia longifoliaTree (False Ashoka ) as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth if any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 226 | Supplying and planting Heliconia Plants as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth if any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 227 | Supplying and planting Vedicator Plants as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth if any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 228 | Supplying and planting Azadirachta indica Tree ( NEEM ) as directed by the Engineer in charge including digging holes in ordinary soils and refilling the same with manure, floating with water and dressing removal of rubbish , surplus earth if any with all lead and lift also maintenance of plant for a period of 90 days from the date of planting work. |
| 229 | Three seater Garden Bench arrangements with 18mm thisck Granite Top and Sides supports and Leg are casted and Jointed with concrete slab member as per standard specification etc complete complying with standard specification and as directed by the departmental officers at site of work.Bench Size : 4' x 1'6\\" |
| 230 | Supply and fixing of tables of following sizes with the following specification . The table is made out of 18 gauge electro glavanized material for the cabinet with epoxy powder coating of thickness 60-80 microns . The panel units , shutter and the entire body shall be of 18 gauge steel with interlocking type construction to form a rigid intergal structure with height adjustable legs with range +/- 50mm .each drawer and shutter will have locking facility . Electrical trunking made out of 1.2 mm thick 18 gauge sheet epoxy coated to a thickness of 60-80 microns with 16A/5A3 pin socket (4 nos) etc. the top is smooth finished jet black granite 18+1 mm thick with edges having round profiles. |
| 231 | \\"L\\" shaped wall Table(2550+3357)L x 750 W x 800 H in mm |
| 232 | Wall Table 6000L x 750 W x 800 H in mm |
| 233 | Manufacturing & Supplying computer Table :- 1200mm X 600mm X 740mmHProviding & Placing Office Table with side unit with following details and specifications : Top and legs are made of 25mm thick Particle Board (E-1 Grade), melamine finish with matching 2mm PVC edge-banding. The Modesty is Particle board wood Grade E-1 (Environmental Friendly) thickness 18 mm cover with Melamine Edge-Banding 2 mm PVC Lipping. Workrtop is provided with Single hanging Drawer pedestal of size 400mm W x 600mm D x 450mm H and standard rectangular Grommet with cover on either end of the table.With keyboard trayE1 Grade laminate to be used which provide no urea formaldehyde emission and formaldehyde should be phenol base with emission of not more than ( |
| 234 | Tripple Seater Stainless Steel Supply of 70 mica powder coated 3 seater capacity waiting chair of (L) 72\\"X (B) 24\\"X (H) 32\\", includings leges and back rest with two supporting legs and two arms at each ends. The seat bottom and back rest should be perforatted MS Fabricated sheets with smooth bends at all edges. The rate includes labour for manufacturing, supply, transportation, etc., |
| 235 | Manufacturing and supplying Main Table :- 2250mm X 900mm X 740mm H Side Table Size - 1050mm X 500-550mm X 740mm HMain & Return Top and legs are made of 25mm E-1 grade particle board finished with 2mm PVC edge banding. E1 grade laminate with zero urea formaldehyde emissions ( |
| 236 | Providing REGISTRATION COUNTER / NURSE STATION of required size by arranging openable cupboard of size 0.90mx0.60 mx0.75m on either side of the workstation at 1.50m apart and top finished with 20mm polished granite top laid over 18mm BWR plywood with suitable adhesive and edges are chamferred. The cabins are fixed with openable drawers 2 Nos at top with roller arrangement for easy operation and bottom portion with openable shutters of side hung with lock and key arrangement fixed in vertical of 18mm(BWR) plywood. The face of the work station is provided with vertical desk top of 0.30m wide and 0.30m height run for the entire length of nurse station. and with half door of horizontal opening and vertical opening on either side of the cabin so as to operate for easy access.The nurse station so fabricated shall be fixed on the different location in the building and polished with melamine varnish of approved quality and brand including preparation of surface. The rate is inclusive of cost of all materials, conveying from the source to workspot, loading, unloading and lifting to various upper floors, labour for wrought and put up etc and cost of furniture fittings, fixing in position and finishing neatly. The rate is also inclusive of all local taxes etc. complete complying with standard specification and as directed by the departmental officers. |
| 237 | Supplying of Chair should be high back, cushioned seat assembly, moulded plywood upholstered with moulded polyurethane foam & finished with Leatherite. Back size: (W) 450 - 500 mm (H) 600-620mm; Seat size: (L) 450mm - 500mm (W) 450 - 500mm with Polyurethane Foam. Polyurethane Foam: The polyurethane foam (Recyclable) of minimum density = 30 kg/ cum + 2 kg/cum fixed to moulded plywood and upholstered with Leatherette. Fixed armrest of premium quality of SS Chromed finish with PU cushion pads. Synchro mechanism: 360 degree revolving type, from pivot for tilt with multiple locking position & feet resting on ground for extra comfort. The pneumatic adjustment has an adjustment stroke of 70-120 mm, Pedestal Assembly: should have 5 star aluminium die cast with hard castors sutable for tiles flooring with adjustment, twin wheel castors & the pitch centre Dia is 650 +/- 50mm. (750 +/- 10mm with castors). Twin wheel castors: these are made of injection moulded in black PP having 50- 60mm dia,complete in all respect. The above chair should be finished / completed as per above mentioned specifications including providing and fixing of other related materials including hardwares, etc. complete or as directed by the Engineer-in- Charge and conforming to the image having back curvature in longitudinal and in trasverse direction as per the image. All complete as per manufacturers specification. Product should be BIFMA gold rated SCSglobal certified for inhouse air quality. |
| 238 | Low back chair with Molded Cushion seat : Executive Low Back Double Ply chair with cushioned seat and back with selected fabric Upholstery, Chromium plated base with revolving casters, hydraulic gas lift and Syncro tilting, Handle to be fixed Features : Comfortable ergonomic ChairBackrest : Comfortable backrest in fibre glass & nylon frame upholstered with mesh. Adjustable lumbar support.Headrest : Adjustable cushion headrestSeat : Medium density foam, moulded plywood and upholstered with fabric. Armrests : 2D adjustable armrest with PU pad for comfort.Mechanism : Back tilt with single position upright locking & simple mechanism. Gas-lift : Class IV Samhongsa gas liftBase : Nylon baseCastors : 5 nos. heavy-duty twin-wheel nylon castors |
| 239 | Providing lab chair 1. Fixed Cushioned seat and back .2. Height adjustable from 540 mm to 660 mm3. Swinging back rest and can be locked at any position4.Aluminum 5 legs Base with S.S. foot ring5. Base fitted with 50 mm (2”) Castors |
| 240 | Providing and placing in position medium back Non revolving Chair Backrest ,Overall Chair size: 445-460W x 450-470Dx 960- 1090Hmm ,The seat and back shall be made up of 12mm. thick hot-pressed plywood upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam shall be designed with contoured lumbar support for extra comfort. The seat shall be extra thick foam on front edge to give comfort to popliteal area. Backrest size 590 mm (H) x 420 mm (W). Spine made of reengineered black nylon. SEAT: The seat is made up of 12 mm thick (7 layers) hot pressed plywood and moulded seat foam upholstered with fabric. The bottom cover made up of injection moulded in black PP to cover the plywood. Seat size 460 mm(W) x 460 mm (D). Minimum and Maximum seating height is 460 mm and 560 mm respectively. Seat/Back Foam: Foam made out of moulded polyurethane foam with the following properties. Average thickness of 65 mm (Width- 460-470 mm, Depth- 460-470 mm) and with the following properties: Density: 52-55 Kg/M³ , Hardness: 25±/3 KGF ,Compression Set: 10% Max,Tensile Strength: 0.90 to 1.2 Kg/Cm² ,Resilience: 40%-60% ,Comfort / Indentation Hardness: 15.4 ,Weight: 650 gms. ,Armrest : Fix Tonic Arm with PP pad, The armrest is made up of Thermo Polyurethane with 40 - 55 Shore Hardness and reinforced with 4 mm thick nylon insert. Arm pad size 235 mm (L) x 80 mm (W). The handle is fitted to the seat with seat/handle connecting strip assembly made of 35% Glass filled nylon 20 mm thick. Standards, Cantilever Base: Base is MS powder coated, 25mm dia pipe frame leg. The height of the frame is 14.5 inches and the length is 21 inches. The width is 18 inches(min) and 20 inches (max).Product should be BIFMA gold rated SCSglobal certified for inhouse air quality and with 05 Years warranty. |
| 241 | Steel Frame powder coated stool :Overall Sizes Diagonal Leg Dia 538 mm H470 min-655maxSS 202 made sheet with spin section of thickness 1mm & should be non corrosive. It should have a diameter of 305mm,seat base is made of MS ring and rectangular tube.EN8 Screw having dia of 22 mm should be used for height adjustment of the seat base.The hub should be made of MS ERW tube having dia of 38mm and thickness 2 mm. The Hub should be welded with the legs and it should accommodate and cover the lead screw mechanism. The under structure should consist of 4 legs made up of MS ERW tube of diameter 25.4 mm and 1.6mm thick. The press formed pipe leg should give a ro und & clean look. All the legs should be provided with 4 nos of Nylon-6 bush.All metal components should be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbial epoxy polyester powder coating to fulfil the requirements for bacterial protection against at least 2 commonly found bacteria in Hospital environment [Gram positive and Gram Negative].Safe working load must be 135kg |
| 242 | Supplying of 3 seater sofa overall dimension - 1800mm W1 x1400mm W2 x 780-810mm D x 760-780mm HWooden structure of sofa to be fabricated using good quiality hardwood duly seasoned and applying anti-termite paint of approved brand & manufacture to ensure stability of the frame, On the wooden base frame of the sofa to be provided withM.S. helical spring, sides & back with jute strips, with polyfill covered with jute & finished with thick marking cloth before doing final finished with Leatherite have basic cost not less than 1500/- Pet Mt. Seat - 35-40Kg/cum density PU Foam, 100mm thick, Back - 35Kg/cum density PU foam, 60mm thick, Sides (inside) - 35 Kg/cum density PU Foam, 45 mm thick Sides (outside) & back (back side) - 35 Kgcum density PU foam, 25mm thick. Seat shall rest on SS square frame of size 25mm x 25mm supported be legs made of 25mm x 25mm square SS section of height 225mm. All SS work should be in grade 304. Base of sofa should be infilled with suitable woode sections so as to give proper support to the seat. Height of the base of sofa shall be 200-250mm(approx). Finished width of arm shall be 100mm after upholstery work. Sofa to be fully upholstered using approved Leather of A grade of desired shade duly embossed including providing & fixing of all other related materials including hardwares etc. complete as directed by the Engineer in charge. Product should be BIFMA gold rated SCSglobal certified for inhouse air quality. |
| 243 | Conference Room Table:15 seater \\"U\\" shape CONFERENCE ROOM TABLE with the following specifications.The table is to be supplied in completely knock down conditions for assembly at site. . The table should be made up of 32mm thick Medium Density Fibre board with balancing laminate. Top is finished with 0.4mm PVC memberebce foil using wrap around technology. table vertical support made with 19mm thick block board and table top & all side finished with 4mm veneer of approved make and top finished with 0.5 mm thick laminate of approved colour. The beading of size 75mm x 25mm thick seasoned solid wood to be provided alround the table top and the same beading finished with melamine polish as per the detailes. beading of The table should have waterfall edge. The foil shall be coated with PU layer for better scratch and wear resistance. MDF board shall be of interior Grade as per IS 12406:2003. the rate inclusive of recess cut out made for comfort usage and provision of Power points sockets and dat & net work cable concealed sytem etc. completeThe 2 seater C of size - 1350mm x 600mm, 1-seater rectangular of size-750mmx600mm, and 2-seater semicircular of size-1350mm x 710mm or 1-seater quarter circular of size 710mm x 710mm. |
| 244 | Pre-treated & powder coated Examination cot of size 6 x 2.5 feet with three drawer in the upper section and three separate cabinet in the lower section, 2 section headrest facilities and foam mattress with rexine cover |
| 245 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 246 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \\"P\\" or \\"S\\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings. |
| 247 | Supplying and providing water dispenser of min. capacity 80 litres capable of dispensing hot, cold and normal water of brand approved by departmental engineers complying with standard specification. |
| 248 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 249 | Without Pedestal |
| 250 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware ovel shaped wash hand basin of size 560 x 450mm, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 251 | Providing & fixing Stainless Wash Sink of size 600 x 450 x 200mm depth with border width of 50mm icluding folding of edges of approved make, connection pipe of approved make & CP waste coupling over the Granite Platform including providing SS vertical splash board of 600mm ht.along with fixing G.I. waste pipe of 32mm dia ‘C’class Approved make below the sink upto Nahani trap through required fixing arrangement like Jam nut etc. complete as directed by the departmental officers . |
| 252 | Supplying and fixing in position best approved quality CI Nahini trap of 100mm x 75mm size with stainless steel grating of approved quality fixed over a bed of brick jelly lime concrete 1:2:5(one lime two sand and five brick jelly) using 40mm broken brick jelly including dismantling the flooring concrete / Brick masonry wherever necessary and redoing the disturbed portion to the original condition and giving in connection to the PVC soil (stacks)pipe as directed etc., complete complying with standard specifications. (The PVC Nahini trap should be got approved from the Executive Engineer before use on works.) |
| 253 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 254 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 255 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works). |
| 256 | Supplying and fixing in position the following foam core pipe grade SN8 complete complying with standard specification including cost and conveyance of all material as directed by the departmental officers. |
| 257 | 50mm dia |
| 258 | 75mm dia |
| 259 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). SN8 Grade |
| 260 | 110mm dia PVC soil / waste pipe |
| 261 | 160mm dia PVC soil / waste pipe |
| 262 | Supplying and fixing in position of the following foam core pipe specials Grade SN8 best approved quality conforming to ISS and providing leak proof joints with adhesive etc, including fixing to walls with necessary teak wood plugs screws etc. and giving connections to the pipe dismantling the brick masonry RCC floor or roof slab and redoing the disturbed portion to original conditions etc. complete complying with standard specifications. (The specials should be got approved from the Executive Engineer before use on works). |
| 263 | 160mm dia Door Bend |
| 264 | 160mm dia Door Elbow |
| 265 | 110mm dia Door Bend |
| 266 | 110mm dia Door Tee |
| 267 | 110mm dia Plain Bend |
| 268 | 110mm dia Single Y Junction with Door |
| 269 | 110mm dia Cowl |
| 270 | 160 mm dia 'Y' with Door |
| 271 | 110mm dia Elbow with Door |
| 272 | Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works). |
| 273 | 110mm dia |
| 274 | Supplying, laying and jointing UPVC Pipes of approved quality and best variety of \\"B\\" class pipe of the following dia including labour fixing UPVC Specials, (excluding charges for cutting and threading of pipes, cost of such specials) to wall with necessary teak wood plugs, clamps, screws, thread balls, shellac, etc., making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessray brick work / concrete and plastering wherever necessry with necessary scaffolding charges. The pipes are to be painted with the 2 coats of good variety and approved best quality of synthetic enamel paint over a priming coat of red oxide etc., complete in all floors complying with standard specification. UPVC shall be got approved by the Executive Engineer before use on works. |
| 275 | 65mm dia |
| 276 | 50mm dia UPVC pipe |
| 277 | 40mm dia UPVC pipe |
| 278 | 32mm dia UPVC pipe |
| 279 | 25mm dia UPVC pipe |
| 280 | 20mm dia UPVC pipe |
| 281 | Supplying and fixing in position the following UPVC Specials of heavy type and approved quality and good variety excluding fixing charges but including necessary cutting and threading of UPVC pipes, jointing the UPVC specials and painting with two coats with good variety and best quality synthetic enamel paint over a coat of red oxide primer and jointing the specials with pipe line using shellac etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.) |
| 282 | 65mm dia UPVC Elbow |
| 283 | 50mm dia UPVC Elbow |
| 284 | 40mm dia UPVC Elbow |
| 285 | 32mm dia UPVC Elbow |
| 286 | 25mm dia UPVC Elbow |
| 287 | 20mm dia UPVC Elbow |
| 288 | 65mm dia UPVC Tee |
| 289 | 50mm dia UPVC Tee |
| 290 | 40mm dia UPVC Tee |
| 291 | 32mm dia UPVC Tee |
| 292 | 25mm dia UPVC Tee |
| 293 | 20mm dia UPVC Tee |
| 294 | 65x50mm dia UPVC Reducer Tee |
| 295 | 50x40 mm dia UPVC Reducer Tee |
| 296 | 40x32 mm dia UPVC Reducer Tee |
| 297 | 32x25mm dia UPVC Reducer Tee |
| 298 | 25x20mm dia UPVC Reducer Tee |
| 299 | 20x15mm dia UPVC Reducer Tee |
| 300 | 65mm dia UPVC Union |
| 301 | 50mm dia UPVC Union |
| 302 | 40mm dia UPVC Union |
| 303 | 32mm dia UPVC Union |
| 304 | 25mm dia UPVC Union |
| 305 | 20mm dia UPVC Union |
| 306 | Supplying, laying and jointing CPVC Pipes of approved quality and best variety of pipe of the following dia including labour fixing UPVC Specials, (excluding charges for cutting of pipes, cost of such specials) to wall with necessary teak wood plugs, clamps, screws, UPVC Solution etc., making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessray brick work / concrete and plastering wherever necessry with necessary scaffolding charges. complete in all floors complying with standard specification. UPVC pipes shall be got approved by the Executive Engineer before use on works. |
| 307 | 20mm dia CPVC pipe |
| 308 | Supplying CPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 309 | 20mm dia CPVC Elbow |
| 310 | 20mm dia CPVC Coupling |
| 311 | 20mm dia CPVC Tee |
| 312 | 20mm dia CPVC Bend |
| 313 | 20mm dia CPVC Union |
| 314 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 315 | 20mm dia Gate valve |
| 316 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 317 | Supplying and fixing in position 15mm dia two way bibcock(heavy duty) with Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 318 | Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works). |
| 319 | Supplying and fixing in position 150 x 100mm \\"P\\" or \\"S\\" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. |
| 320 | Making through holes in Plain or Reinforced Cement Concrete with Diamond Core Drilling System by using BOSCH power tools of following diameter - Depth per cm |
| 321 | 100 mm |
| 322 | 150 mm |
| 323 | 200 mm |
| 324 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 325 | 160mm dia |
| 326 | Providing rain water harvesting pit of 1.50m dia and 1.50m depth with necessary earth work excavation,erecting the five nos of Rcc collar of 1.50m dia,sand filling of 0.60m depth,filling of 40mm HBS Jelly of 0.60m depth and covering with Rcc cover slab of 50mm thick and also connecting 110mm dia PVC pipe of 10.00m legth including transporting charges,fixing,etc.complete. |
| 327 | Construction of Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9\\" thick brick work in cement mortar 1:5 using Fly Ash Bricks of 230 x 110 x 75mm filling the size of foundation with excavated earth, plastering with cm 1:3 20m thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and finishing neatly etc., complete. |
| 328 | Inspection Chamber of Size 0.60 x 0.60 x 0.60m (average depth) |
| 329 | Inspection Chamber of Size 0.90 x 0.90 x 0.60m (average depth) |
| 330 | Supplying and fixing of cylindrical vertical notational polythene water storage tank confirming to IS. 12701 / 96. The tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simple pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank, and the tank should be fixed firmly. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., complete complying with standard specification and as directed by the departmental officers. (The water tank should be got approved by the Executive Engineer before use on works by the Departmental Officers. |
| 331 | Drilling of Borewells in Chennai District including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site shown by the Engineer Incharge including construction of mud pit etc., complete as directed. (Drilling 140/150 mm dia pilot bore) |
| 332 | Reaming 140 / 150 mm dia pilot bore to 300mm dia bore etc complete complying with standard specification and as directed by the departmental officers.Upto 60m depth ending below ground level. |
| 333 | Supplying of PVC casing pipes 160mm assembly in the drilled hole including welding the joints etc., complete supplying and packing the annular space with pebbles of size and quality as approved by the Executive Engineers |
| 334 | Without slot |
| 335 | With slot |
| 336 | Labour charges for inserting casing pipes assembly (with slot or with out slot) n the drilled hole including welding the joint ewtc. Complte and supplying and packing the annular space with pebbles of size and quality as approved by the executive engineer |
| 337 | Charges fordeveloping the Borewell with air compressor of 600 CFH capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWD officers and conducting yield test by V notch method. |
| 338 | Supplying of best and approved quality of HDPE pipe of the 40mm size including laying in the bore well and tying with copper wire it etc complete complying with standard specification. |
| 339 | Supply and Installation of 1000 LPH capacity Fully Automatic Reverse Osmosis Plant to deliver Potable Water with World Health Organisation (WHO) standards with following specifications. 01. Raw water feed pump 1.0 HP - 1 No. of make Grundfos/CNP/Eq. 02. Pressure sand filter - 1 No. of make Pentair/Eq. Vessel size - 350 x 1500 mm with Multiport Valve - Filter - Auto backwash of size 25 NB, Media - Graded Pebbles, Sand, Silex 03. Activated Carbon filter - 1No. of make Pentair/Eq Media - Activated Carbon + Supported Bed 04. Dosing Systems(Antiscalent & pH Booster ) - 2 Nos of make Hydrolynn/E-Dose/Eq of capacity 0-6 l/hr with chemical tank (2 Nos) of 50l capacity 05. Micron Filters - 2 Nos 06. High Pressure pump (3 Hp) - 1 No of make Grundfos / CNP / Eq 07. R.O Membrane system - 4 Nos of make Toray/Hydrounatic/Eq with 2 Nos of membrane housing 08. RO Skid - 1 No (SS 304) Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact |
| 340 | Design,supply&fixing of Gas outlet points:(Self Sealing type-Single/Dinoutlet type) with S type bracket made up of copper and the out let of non-interchangeable for other gas.The outlet points are brazed with brass bracket with self sealing valve(stainless steel) with all accessories and complete set and are converted by plastic cover duly colour coated as per specific gas and button cover etc.,complete as directed by the departmental officers and as per IS Code 12827/1989 & ISO 7396/1987 specification. |
| 341 | Supply and installation of Medical gas copper pipe line arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsencial phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (Tee,Elbow,Reducer,Coupling).The copper pipe lines should be tested suitable for a steam of working pressure of 17.34kg./cm2(17 bar) and confirm to BS 864 standard with specially made for brazed socket type connection.The medical gas copper pipeline should be tested as per standard and commissioning after painting as per international code no IS 2379/1963 Table-V.The pipe lines installed at the various wings and floors etc.,complete as directed by the departmental officers as per IS code 12827/1989&ISO 7396/1987 specification. |
| 342 | 54mm dia copper pipe ODx0.9mm thick |
| 343 | 42mm dia copper pipe ODx0.9mm thick |
| 344 | 28mm dia copper pipe ODx0.9mm thick |
| 345 | 22mm dia copper pipe ODx0.9mm thick |
| 346 | 15mm dia copper pipe ODx0.9mm thick |
| 347 | 10mm dia copper pipe ODx0.9mm thick |
| 348 | Brass Isolation valve. suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball value of RB or Italy or reputed make,connected in line with medical gas pipe line system by using suitable size brass valve adopter union,ferrule,nipple,rubber \\"O\\" ring,taption lap and etc.All pipe line regulators shall be capable of controlling pipee line pressure and must compatible with the requirements specified in IS 12827-1989.All valves should be pneumatically tested for twice the working pressure for the gas line as per IS code 12827/1989&ISO 7396/1987 specification. |
| 349 | 42mm dia valve |
| 350 | 28mm dia valve |
| 351 | 22mm dia valve |
| 352 | 15mm dia valve |
| 353 | Oxygen manifold arrangements of 2bankX12 cylinder each wing with Piston type semi automatic control panel which includes contact gauge 2 Nos.,outlet pressure gauge ,brass heavy duty Ioxregulator 2 Nos. with suitable adopter,flexible SS hose.Manifold shall be of a construction and of a designs and matreial suitable for the service pressure in accordance with IS 1282-1989.Emergency alarms with illuminating display for low / high pipe line pressure and malfunctioning of system. 1) Manifold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing,silver brazing,non return valve,fasteners and cylinder support middle angle frame for claping 2x12 cylinders and related fastenders.The O2 manifold should with stand a pressure of 140kg/CM2.The installation is commissioned after testing as per standards and painted as per international code and as directed by the departmental officers as per IS code 12827/1989&ISO 7396/1987 specification. |
| 354 | Nitrous Oxide Manifold Arrangements of 2 banks 3Cylinder each wing, with Piston type semi automatic control panel which includes contact gauge 2 Nos. outlet pressure gauge, brass heavy duty IOX regulator 2 Nos. with suitable adopter, flexible SS hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 12827 -1989. Emergency alarams with illuminating display for low / high pipe line pressure and malfunctioning of system. 1) 2x3 cyliner Nitrus Oxide Manifold should be suitable with stand a pressure of 140kg/ Cm2 and above along with high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous Oxide Cyliners and manifold.2) Top frames comprising of high pressure copper pipe of size 12mm ID 1.5mm wall thick with high pressure brass fittings made of high tensile brass and connetions through non -return valves, high pressure copper tail pipes made of high pressure copper pipe size of 7mm ID 1.5mm thick. 3) The disign of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely with fitted heavy duty regualtor. The Manifold should be tested at 3500 pig as per IS 12827/1989 & ISO 7396 / 1987 Specification. |
| 355 | Supply, installation,testing and commissioning of equivalent to ingersoll rand reciprocating Air cooled type (5HP) rating vaccum pump as per following provisions.As per IS 12827/1987&ISO 7396/1987 specification |
| 356 | Supply,installation,testing,and commissioning of MS fabricated vertical mounted type 1000 liters capacity vacuum receiver with inlet and drain holes provided suitable to operate with vacuum pump,etc., as directed by the departmental officers. |
| 357 | Supply, installation,testing and commissioning of compressed air system of reciprocating Oil Free Air Compressor belt driven type air compressor with following provisions. As per IS 12827/1987&ISO 7396/1987 specification. |
| 358 | Supply,installation,testing,and commissioning of MS fabricated vertical mounted type 1000 liters capacity Air receiver with inlet and drain holes provided suitable to operate with vacuum pump,etc., as directed by the departmental officers. |
| 359 | Supply of Flow meter with humidifier bottle flow meter should be back pressure compressed flow meter should be accurate gas flow measurement with control range 0-13 litres per minute.It should meet strict permission and dumbling standard.The meter body should be made of unbreakable polycarbonate material and auto cleavable at 134 degrees centigrade.The rate includes flow meter and its accessories (Silicon tube with mask).The cost of materials including transport-taxes etc complete as standard as directed by the departmental officers and as per IS 12827/1989 and ISO 7396/1987 specification. |
| 360 | Supply of ward vacuum unit with gauge both mounted on a collection jar of capacity 600ml and with a wall bracket for mounting it on the wall. The collection jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degrees centigrade as per standard specification and as directed by the departmental officers and as per IS 12827/1989 and ISO 7396/1987 specification.The rate includes cost of silicon hose with SS nipple on either side. |
| 361 | Theatre vacuum unit:The unit should comprise of two reusable 2000ml shatter resistant bottle .Each made up of ply carbonate material and fully autoclavable at 134 degree centigrade,should have a vacuum regulator with instant ON/OFF switch and tree way left,right or both.All the above items should be mounted on a trolley having free moving castor wheels.(As per IS 12827 /19898&ISO 7396/1987 |
| 362 | BED HEAD PANEL supplying and fixing of bed head panel size for 1 m length and height of 0-30 cm depth of 4\\".The Aluminium powder coated with requirment colour for provision points of O2-2 Nos,Air-1No,Vacuum-1No with double electrical socket with switch 2Nos with 2 set with 1 V-bottle holder fixing to the wall hanging including monitor stand etc complete |
| 363 | Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes etc., complete as per MoRT&H specification No.803 |
| 364 | Road Markers/Road Stud with Lens Reflector Providing and fixing reflective road studs of ‘category A’ Raised pavement markers made out of polycarbonate / methyl methercrylate/ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280. The reflective raised pavement markers shall also confirm to the MoRT&H circular No RW / NH. 33023/10/ 97-DO. III dt 11.06.97. The height, width and length shall not be less than 15 mm, 90 mm and 100 mm and with minimum reflective area of 13 Sq.cm on each side and the slope to the base shall be 35 (+/-) 5 degree. Each reflector shall have a CIL not less than values specified in Table 2 of said MoRT&H circular. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 (+/-) 2mm and height not less than 30 (+/-) 2 mm) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the Engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35 - 2015 guidelines and MoRT&H specification 804 etc., complete |
| 365 | Supplying and Fixing of R.C.C hume pipe 300mm dia and wall thickness of 50mm and laying in proper position complete complying with standard specification and as directed by the Departmental officers. |
| 366 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 367 | Providing and fixing of FRP Gratings of 600 x 300mm size with M.S flats of 25x10mm for outer frames, 25x6mm for inner braces and PVC pipe 150mm dia fixed with mild steel grating, including cost and coveyance of pipes and gratings and fixing them in position (At 5m interval) |
| 368 | Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter of size 750x750mm 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm madeup of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers |
| 369 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 370 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 371 | Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., a) Manually operated (up to 8 m2 area) |
| 372 | Supplying fabricating and fixing in position Tensile roof with required MS Frame with proper welding at required places and colour of Tensile roof as directed by departmental officers at site of work. The rate includes transportation charges, lead charges, fixing charges, electricity charges, hire for scaffolding etc.,complying with standard specification and as directed by departmental officers |
| 373 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.-110 mm Ground floor only |
| 374 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 5 points / Coil) |
| 375 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) |
| 376 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) |
| 377 | Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Stair case Light point |
| 378 | Wiring with 2 x 4 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitablePVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point (8 points / Coil) |
| 379 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper lead s from terminals to the fitting |
| 380 | Supply and Fixing of 2 x 22W 4 Feet LED Fitting with 2 Nos 20W Direct LED Tube with complete set on ceiling with suspension downrod with PVC unsheathed copper leads from terminals to the Fittings. |
| 381 | Supply and fixing of 36W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 382 | Supply and fixing of 24W LED 1x1 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 383 | Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. |
| 384 | Supply and fixing of 36W LED 2x2 square type surface fitting with LED (Higher end) on ceiling with suitable clamp with PVC unsheathed copper leads from terminals to the fitting. |
| 385 | Supply and fixing of 24W LED 1x1 square type surface fitting with LED (Higher end) on ceiling with suitable clamp with PVC unsheathed copper leads from terminals to the fitting. |
| 386 | Supply and fixing of WT bulk head fitting suitable with guard and 15 W (100W) LED bulb |
| 387 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting . |
| 388 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 389 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (Make: Crompton) |
| 390 | Supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan |
| 391 | Supply and fixing of 450mm (18\\") sweep (Heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall. (Make: Crompton) |
| 392 | Supply and fixing of light trap arrangements for 450mm (18\\") sweep exhaust fan |
| 393 | Supply and fixing of Emergency 2 X 60W PEL LED LML (CP) FF (FullFascia) with 1.5 Hrs back up battery on wall or on ceiling with suitable clamping with PVC unsheathed copper leads from terminal to the fittings. |
| 394 | Supply and fixing of 15w Recesses LED round type mounting 'philips model no.59185.LED recesses ceiling Fitting complete with PVC unsheathed copper leads from terminals to the Fittings. (Havells/ Equ make) |
| 395 | Supply and fixing of Sky pro LED Strip168 LED(CDL)Rope light fitting with drive unit (Warm White)with Drive fixing with complete connection etc., |
| 396 | Supply and fixing of 30 watts LED UNICO false ceiling round type 'Havells make\\" fixing on GF Lobby & Portico area with PVC unsheathed Copper leads from terminals to the fitting complete etc, |
| 397 | Supply and fixing of 8 watts LED UNICO false ceiling round type 'Havells make\\" fixing on GF Lobby area with PVC unsheathed Copper leads from terminals to the fitting complete etc,. |
| 398 | Supply and fixing of 50 watts LED Cylinder round type 'K-Lite make\\" fixing on GF Portico area with PVC unsheathed Copper leads from terminals to the fitting complete etc,. |
| 399 | Supply and fixing of 15 watts LED Up and Down type fitting Havells/ Equiv make\\" fixing on GF Portico area Entrance pillar with PVC unsheathed Copper leads from terminals to the fitting complete etc, |
| 400 | Supply and fixing of 4 feet 22 watts LED Linear fitting Havells/Equiv ( cat no.DESTPROLP/ S22WLED840WH 1200SD fixing on ceiling with suspension conduit pipe/ chain with PVC unsheathed Copper leads from terminals to the fitting complete etc, |
| 401 | Supply and fixing of 1000W automatic electric water heater of 25 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire,but without plumbing work |
| 402 | Supply and fixing of 1500W automatic electric water heater of 35 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection |
| 403 | Supply and fixing of 1 nos.6A two module 3 pin socket , 2 nos. 6A one module switch on suitable module surface mounting Box (Plastic) with module cover plate (plastic) on wall with connections. |
| 404 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. |
| 405 | Supply and fixing of 2nos.6A two module 3 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. |
| 406 | Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. |
| 407 | Supply and fixing of 2nos.6/16A two module socket , 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. |
| 408 | Supply and fixing of 2nos.6A two module socket , 2 no. 6/16A two module socket , 2 nos. 6A one module switch, 2 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. |
| 409 | Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) |
| 410 | Supply and fixing of 32A DP MCB with suitable weather proof enclosure on wall with necessary earth connection. (Hager / Legrand) |
| 411 | Supply and fixing of 32A FP MCB with suitable weather proof enclosure on wall with necessary earth connection. (Hager / Legrand) |
| 412 | Supply and fixing of 63A FP MCB with suitable weather proof enclosure on wall with necessary earth connection. (Hager / Legrand) |
| 413 | Supply and fixing of 32A DP MCB with suitable sheet steel enclosure on wall with suitable necessary connection. (Make: Hager / Legrand) |
| 414 | Supply and fixing of 32A FP MCB with suitable sheet steel enclosure on wall with suitable necessary connection. (Make: Hager / Legrand) |
| 415 | Supply and fixing of 63A FP MCB with suitable sheet steel Enclosure in flush with wall with necessary earth connection. (Hager / Legrand) |
| 416 | Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5 sq.mm copper wire with painting of suitable colour SD 54 |
| 417 | Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour |
| 418 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion |
| 419 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour |
| 420 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. |
| 421 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A FP MCB switch as incoming, 1 no 40A ELCB, 1 no 32A DP MCB and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. (For Lift) |
| 422 | Supply and fixing of Three phase Seven Segment type 4 way 63A distribution board with Metal Door cover Code IP42 Protection, with 63A 4 pole MCB as incoming and Sub incomers 3 Nos 40A DP MCB and 12 Nos 16-32A SPMCB as Outgoing in flush with wall with making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Higher End) (MLDB) |
| 423 | Supply and fixing of Three phase Seven Segment type 6 way 100A distribution board with Metal Door cover Code IP42 Protection, with 100A 4 pole MCB as incoming and Sub incomers 3 Nos 63A DP MCB and 18 Nos 16-32A SPMCB as Outgoing in flush with wall with making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Higher End) (Make:legrand / Hager) |
| 424 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. |
| 425 | Supply and Fixing of 6 way 125A Vertical TPN Distribution Boards (with MCB Incomer); Double Door; IP43 with 1 No 125A 4 pole MCB as incoming and 4 Nos 63A TP MCB, and 6 Nos 6-32A SP MCB as Outgoing in flush with wall with making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Higher End) (Make:legrand / Hager) |
| 426 | Supply and fixing of 250 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. |
| 427 | Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 428 | Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour. |
| 429 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. |
| 430 | Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed position. |
| 431 | Supply, erection ,testing and commissioning of 15 KVA UPS system (Three phase input & Single phase output) 1 hours back- up for the following configuration1) True ON LINE –UPS SYSTEMS with Pulse width modulation(PWM) Technology using IGBT Inverter.2) INPUT VOLTAGE RANGE : 415V3)OUTPUT VOLTAGE : 415V ± 1%4)DC Volt:120V5)INPUT FREQUENCY : 50Hz ± 5%6)Out put Frequency: 50Hz ± 2%7) Out put Waveform:Pure Sine Wave8) LOAD POWER FACTOR : 0.8 to Unity9)HarmonicDistoration: Less than 5%10)Over Load: : 125% for 10Minutes11)Inverter Operation : PWM-IGBT12)Invertor Efficience : Better Than 90%13)OPERATING TEMPERATURE : 0 to 50 Degrees centigrade’s on Full Load14)Digital Panel Meter : To Read output A/C Volts,Output D/C Volts Frequency15)By pass : Automatic |
| 432 | 16)PROTECTION (INBUILT) : a. Output Under Voltageb. Output Over Voltagec. Output Overloadd. Output Short Circuit e. HRC Fuses, Output & Batteryf. Battery Low tripg. Battery Charging Current Limit.17)INDICATIONS : 1. Mains On,2. Inverter On,3. Load on U.P.S.5. Battery Low6.Over load7.Inverter Trip. |
| 433 | Supply, erection ,testing and commissioning of 10 KVA UPS system (Three phase input & Single phase output) 1 hours back- up for the following configuration 1) True ON LINE –UPS SYSTEMS with Pulse width modulation(PWM) Technology using IGBT Inverter.2) INPUT VOLTAGE RANGE : 415V3)OUTPUT VOLTAGE : 415V ± 1%4)DC Volt:120V5)INPUT FREQUENCY : 50Hz ± 5%6)Out put Frequency: 50Hz ± 2%7) Out put Waveform:Pure Sine Wave8) LOAD POWER FACTOR : 0.8 to Unity9)HarmonicDistoration: Less than 5%10)Over Load: : 125% for 10Minutes11)Inverter Operation : PWM-IGBT12)Invertor Efficience : Better Than 90%13)OPERATING TEMPERATURE : 0 to 50 |
| 434 | Degrees centigrade’s on Full Load14)Digital Panel Meter : To Read output A/C Volts,Output D/C Volts Frequency15)By pass : Automatic16)PROTECTION (INBUILT) : a. Output Under Voltageb. Output Over Voltagec. Output Overloadd. Output Short Circuit e. HRC Fuses, Output & Batteryf. Battery Low trip |
| 435 | g. Battery Charging Current Limit.17)INDICATIONS : 1. Mains On,2. Inverter On,3. Load on U.P.S.5. Battery Low6.Over load7.Inverter Trip. (Make: Numeric / Fuji) |
| 436 | Supply and fixing of 63A FP changeover MCB with suitable sheet steel enclosure on wall with suitable necessary connection. (Make: Hager / Legrand) |
| 437 | Supply and fixing of 4 Mtr Air termination rod 16 /10 mm (Lightning Rod) with Aluminium alloy Solid Round Conductor with 8mm dia of material AlMgSi as per IEC 62561-2 with Conductor Hold er, glue, connectors, joints etc. |
| 438 | Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length |
| 439 | Supply and fixing of S.S test joint |
| 440 | Supply and Fixing of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor for Earth termination |
| 441 | Supply and fixing of S.S. conductor holder |
| 442 | Supply and fixiing of 25mm X 6mm GI strip |
| 443 | Supply, Erection, Testing, Commissioning and Handing over of 1 No 1010 KVA Diesel Generator set of 0.8P.f, Three Phase, 415/420Volts, 50c/s, 1500RPM as detailed below 1.ENGINE: Water cooled Diesel engine suitable for generator application with a shaft Output of 1735 BHP at 1500 RPM under NTP Condition as per BSS 5514/IS 10000. The engine shall comprise the following standard scope of supply: 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter(pre and micro) 8. In-line Mono-block fuel injection pump with governor and fuel feed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate |
| 444 | 13. Residential Mufler 14. Fly wheel with starter ring. ENGINE INSTRUMENTPANEL MOUNTED. Engine control panel consisting of ON/OFF/START Key Lube oil pressure guage , oil temperature gauge, high water temperature guage and electronic hour meter and RPM indicator. SAFETY SYSTEM OF ENGINE :-The Engine shall trip for the following conditions with visual alarm device 1. Low lubricating oil pressure 2. High Water temperature 3. Vee-belt failure and over speed 4. The visual indicator should be provide for Low battery indication. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load. 2. ALTERNATOR : Alternator capacity of 1010 KVA/ 1200 KW,AC 3 phase, 50HZ, 415/420V, 0.8P.F.4 wire self excited, self regulated designed to run at 1500 RPM under |
| 445 | NTP conditions confirming to BS 5000/ IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate. 3.ACOUSTIC ENCLOSURE:- Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet.The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machine to maintain dimensional accuracy of hole |
| 446 | within 0.1mm Powder coating done after seven – tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64 Kg/m density mineral wool of 100mm thickness as Acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1 Mt distance shall be less than 75 DBA average or as per CPCB norms. Surface treatment – Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven – tank treatment thoroughly. Additional features of canopies: Canopy fabricated on CNC machines with dimensional accuracy of 0.1 mm so as to increase its durability. |
| 447 | Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any World class Cooling package: Canopies shall have cooling package for which it can also perform at 45 degree C/ambient temperature.No grouting required on the ground, only a level surface capable of with standing the DG weight.Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. 1150.00 30250.00 The Gen set frame shall also be provided with hooks for unloading Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 5-7 deg centigrade. 4. FUEL TANK : 990 liters capacity fuel tank with mounting brackets, complete with level indicator, fuel inlet and outlet, air vent, drain plug, inlet arrangements for direct filling. |
| 448 | pa inted and fitted with inlet and outlet connection and mechanical uel gauge. Fuel tank can be easily removed for clearing or any maintenance. 5. BASE FRAME : The base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall be have provision for mounting of acoustic enclosure on it. The supply of generator set includes loading. Unloading and transportation charges. 6. Battery: 2 Nos 12V 180AHR Battery |
| 449 | 7. AMF Panel: Supply, Erection, Testing, Commissioning and Handing over of 1 No 1010 KVA Diesel Generator Cubical type AMF floor mounting control panel with hinged doors un-drill bottom gland plate accommodating the following: 1.Air Circuit breaker, FP EDO type U/V release, overload relay with short circuit protection. 2.Continous diplay (digital) A/V/HZ Meters. 3.Continous display (digital) kW/PF/kVA Meters. 4.kWhr meter 5.Current transformers 6.Indicating lamps for supply ON & Load ON 7.Instruments fuses 8.Earth fault relay 9.Differential protecion relay 10.Control for space heaters 11.Copper bus bar as per standard requirements. |
| 450 | Note: Obtaining of Pollution control certificate for the newly ereting 1010KVA Diesel generator with CPCB IV+ Norms and BIS Specification is on contractor side |
| 451 | Civil work Foundation for the size of 6Mtrs x 6Mtrs x height 1.0 Mtrs brick wall with post pcc concret 3 feet wth coarry dust filling for the plinth with complete 25mm cement concrete mat flooring and good finishing etc. |
| 452 | Supply and clamping of 3 Runs 3 ½ x400 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. |
| 453 | Supply and fixing of brass cable gland for 3 ½ x400 sq.mm PVC LTUG armoured cable with earth connection |
| 454 | Supply and providing cable end termination of 3 ½ x400 sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection complete |
| 455 | Supply and Run of 10 core 2.5 sqmm armoured copper control cable FRLS in suitable PVC rigid pipe on wall/Ground/ceiling with connection |
| 456 | Supply, Erection, Testing, Commissioning and Handing over of 1No 26 Persons Bed cum Passenger Lift with narrow vision panel as per following technical specifications 1. Location: Newly proposed Centre of Excellence for Cardiac Science at RGGGH Campus, Chennai.. 2. No of Lift: One No. 3. Type of Lift: Gearless lift with Machine Room. 4. Capacity of Lift :26 Persons. (1768 Kgs) 5. Speed: 1.00 mtr / Sec 6. Type of Drive: Microprocessor based specific variable voltage variable frequency V3F with enhanced ride |
| 457 | comfort and near zero leveling functions. VVVF Drive. 7. No of floor:16 floors( Basement + Ground + 14 floors). 8. Total Travel: 39 mtrs approximate 9. Leveling Accuracy: High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel hairline finish No.4 hair line finish & panels with Direct lighting and New Beautiful Single Tile false ceiling with Tubular Handrail and mirror. 11. Position of Machine: Directly above the lift well shaft gearless. 12. No. of Landing Entrance: One in front - 16 Nos only. 13. No. of Car Entrance: One in front only. 14. Car Entrance Door: centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel operated centre opening SS cars. 15. Landing Entrance Door: centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel Power operated V3F Drive Centre opening stainless steel No.4 Hair line finish with view panel . door with provision for emergency key opening at all landing. 16. Car size: 2400 mm widex 1600mm deep (part 1) |
| 458 | 17. Car clear Opening: (as per IS 14665 (part 1) - 1000 (wide) x 2000mm Height. (as per IS 14665 (Part-I)-2000). 18. Lift well : 2700mm (width) x 3490 mm, 2550mm (width) x 3300 mm, (depth) and 1900mm (width) x 2700 mm, (depth) available size. 19. Lift pit depth available: 1600mm 20. Power supply : 415V,400/440v, 3 phase, 50 cy / Sec A.C supply for power and 230V, 50 Hz single phase AC supply for light. 21. Control: Micro processor Computer based - simplex collective full collective logic system with or without attendant mode. 22. Car fittings:Indirect fluorescent light & Fan. 23. Lift Well: RCC construction with Brick masonry existing. 24. Lift Machine Room: As per standard specification 1800mm (Width) x 1500mm(depth) (as per IS 14665 (Part-5) - 2000) 25. Induction: Up / Down Digital Direction scroll type and position indicator for all landing and in car. 26. Emergency Alarm Bell: Battery Operated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be |
| 459 | provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift Contractor. 31. Stainless Steel still angles and facia Plates: To be provided by lift contractor. 32. Steel for lift Machinery: To be Provided by lift contractor. 33.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarntee period of one year 34. Provision of 1+3 EPABX intercom with phone to be provided at the following places vide 1. Lift Head Room 2. Reception Room and 3. Inside the Lift by lift contractor. 35.Lift License: Preparation of drawing , payment of charges to CEIG and insurance policy if any and obtaining CEIG safety certificate and lift license as per lift act should be done by the lift contractor. 36. Automatic rescue device: To facilitate the landing of the nearest floor at the time of power failure. This shall |
| 460 | consist of suitable type battery system with charger inverter under voltage protection system etc. Note: This rate arrived with inclusive of charges for Granite Flooring. |
| 461 | Supply, Erection, Testing, Commissioning and Handing over of 1No 20 Persons Passenger Lift with narrow vision panel as per following technical specifications 1. Location: Newly proposed Centre of Excellence for Cardiac Science at RGGGH Campus, Chennai.. 2. No of Lift: One No. 3. Type of Lift: Gearless lift with Machine Room. 4. Capacity of Lift :20 Persons. (1360 Kgs) 5. Speed: 1.5 mtr / Sec 6. Type of Drive: Microprocessor based specific variable voltage variable frequency V3F with enhanced ride |
| 462 | comfort and near zero leveling functions. VVVF Drive. 7. No of floor:Basemet + Ground + 16 floors. 8. Total Travel: 39 mtrs approximate 9. Leveling Accuracy: High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel hairline finish No.4 hair line finish & panels with Direct lighting and New Beautiful Single Tile false ceiling with Tubular Handrail and mirror. 11. Position of Machine: Directly above the lift well shaft gearless. 12. No. of Landing Entrance: One in front - 16 Nos only. 13. No. of Car Entrance: One in front only. 14. Car Entrance Door: centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel operated centre opening SS cars. 15. Landing Entrance Door: centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel Power operated V3F Drive Centre opening stainless steel No.4 Hair line finish with view panel . door with provision for emergency key opening at all landing. 16. Car size: 2400 mm widex 1600mm deep (part 1) |
| 463 | 17. Car clear Opening: (as per IS 14665 (part 1) - 1000 (wide) x 2000mm Height. (as per IS 14665 (Part-I)-2000). 18. Lift well : 2450mm (width) x 2100 mm, 2000mm (width) x 1500 mm, (depth) and 2200mm (width) x 2600 mm, (depth) available size. 19. Lift pit depth available: 1500mm 20. Power supply : 415V,400/440v, 3 phase, 50 cy / Sec A.C supply for power and 230V, 50 Hz single phase AC supply for light. 21. Control: Micro processor Computer based - simplex collective full collective logic system with or without attendant mode. 22. Car fittings:Indirect fluorescent light & Fan. 23. Lift Well: RCC construction with Brick masonry existing. 24. Lift Machine Room: As per standard specification 1800mm (Width) x 1500mm(depth) (as per IS 14665 (Part-5) - 2000) 25. Induction: Up / Down Digital Direction scroll type and position indicator for all landing and in car. 26. Emergency Alarm Bell: Battery Operated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be |
| 464 | provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift Contractor. 31. Stainless Steel still angles and facia Plates: To be provided by lift contractor. 32. Steel for lift Machinery: To be Provided by lift contractor. 33.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarntee period of one year 34. Provision of 1+3 EPABX intercom with phone to be provided at the following places vide 1. Lift Head Room 2. Reception Room and 3. Inside the Lift by lift contractor. 35.Lift License: Preparation of drawing , payment of charges to CEIG and insurance policy if any and obtaining CEIG safety certificate and lift license as per lift act should be done by the lift contractor. 36. Automatic rescue device: To facilitate the landing of the nearest floor at the time of power failure. This shall |
| 465 | consist of suitable type battery system with charger inverter under voltage protection system etc. Note: This rate arrived with inclusive of charges for Granite Flooring. |
| 466 | Design, Engineering, supply, fabrication. Erection, Testing commissioning and handing over of 1 No. Goods (Dump) Lift (Gearless without machine Room) as per the following Technical Specification. 1.Type of Lift : Dump waiter lift 2. Capacity of Lift : 150 Kg 3. Speed : 1.00 Meter/Sec 4. Type of Drive: specific Variable Voltage Variable Frequency V3F Drive with Enhanced ride comfort and levelling functions. 5. No. of Floors/Stops : Basemet + Ground floor + 14 Floor/ 13 Stop 6. Total Travel : 39 Metres (Approx) 7. Levelling Accuracy: High Level Accuracy with Smooth and jerk free stopping. 8. Construction of Car: High quality and suitable thickness S.S.car and MS false ceiling 9. Position of Machine: Directly above the Lift shaft. 10. No. of Landing Entrance : 14 (Ground to 13th floor) 11. No. of car Entrance: One in Front only. 12. Car Entrance Door: Power Operated V3F drive side Opening Sliding S.S Doors with VF operation. 13. Landing Entrance Door: Power Operated V3F driver Side Opening S.S Doors with provision emergency key opening at all Landings. 14. Lift Well Existing: 1340 mm (width) X 1600 mm (depth). 15. Lift Pit Depth required: 1600 mm 16. Car Size : 820 mm (Width) X 820 mm (Depth) X 1200mm (Height) 17. Car Clear Opening: 870 mm X 1170 mm 18. Power Supply: 400 / 440 V, 3 Phase, 50Cycles / Sec AC supply for power and 230V 50HZ single phase AC Supply for light at machine room |
| 467 | with proper two distinct earth flat of adequate size from ISI earthing at ground floor. 19. Control: Microcomputer (Microprocessor) based Simplex, Collective control with or without attendant. 20. Car Fittings: Compact Fluorescent Lighting with 2 Nos.300 mm Sweep Cabin Fan. 21. Lift Well: R.C.C Construction with Brick Masonry. 22. Indication: UP/DOWN Digital Direction and position indicator for all landing and inside the car. 23. Emergency Alarm Bell: Battery Operated alarm bell with Automatic Charging Device. 24. Emergency Light: Battery operated Light with Automatic Charging Device. 25. Fire Man’s Switch: Include at Ground Floor.26. Scaffolding: Included. 27. M.S. Sill angels and facis Plates: Included 28. Steel for Lift Machinery: Included 29.Servicing and maintenance: Free comprehensive servicing and maintenance during the guarantee period of one year.30. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of Power Failure. This shall consists of suitable type of Battery system with charger, invertor, under Voltage Protection system etc., Complete with all Accessories. 31. Provision of Intercom with phone: Included 32. Lift Licence: Preparation of Drawing, payment of |
| 468 | Charges to CEIG / Lift inspectorate and insurance policies if any and obtaining CEIG safety certificate as per Lift Act. 33. Floor Annunciator with music: Included. 34. SPECIAL FEATURE: A.) Infra-Red colour Sensor with Height Screen. B.) Stainless steel signal fixtures. C.) Vandal Proof Button with S.S Cover. D.) S.S door frames for landing doors. E.) VF Door operator. F.) Calls register Signal. G.) Stainless Steel Facia plate for car operating Panel and landing fixtures. H.) ON-OFF Switch for fan and Light. I.) Voice Annunciator. 35. Lift Duty motor of adequate capacity reduction worm gear, electromagnetic brake with compression springs, over speed Governor, Phase failure and phase reversal relay, alarm Bell, T Guide Brackets for car and Counter weight, Rubber padding under winding unit, car safety Gears, Buffer, Electro Mechanical Door Locks, Emergency Key, Side supporting angles motor Over Load Protection Devices. Final limit Switch, main suspension ropes, Counter weights, Lifting Joist for Mounting the Machineries. 36. Site testing in accordance with IS 14556 should be carried out at the time of handing over. |
| 469 | supply and fixing of 6 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB Incomer ) with double door (metal door) with 1 no. 160 A 4 P MCCB switch as incoming and 4 nos. 63A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End. (Make: Legrand) (Ess. Lift DB) |
| 470 | supply and clamping of 3 1/2 x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. |
| 471 | supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. |
| 472 | supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. |
| 473 | supply and clarnping of 3 1/2 x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. |
| 474 | supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection. |
| 475 | supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. |
| 476 | Supply installation, testing and commissioning of Addressable fire alarm Panel which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have CORTEX 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NAC's, and Three Programmable Relays, and 1 Loop Card circuits. power Supply Board which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. the panel have IP-50 rating Optional: for BMS integration MODBUS converter, Graphical Software, Software for TCP/IP Module, provision for Auto dialler, Supply of 2 Loop Card which will have 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring Approval UL Listed, Make: Ravel (Make: Honeywell)(SR) |
| 477 | Supply, installation, testing and commissioning of Addressable Smoke detector with base with Binary coded address setting. Dual LED’s for 360° visibility. Sleek low-profile housing design. mounted on ceiling / false ceiling with Regular 100mm base. IP Rating : IP - 42 using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Honeywell)(SR) |
| 478 | Supply, installation, testing and commissioning of Addressable Heat detector with base with Binary coded address setting. Dual LED’s for 360° visibility. Sleek low-profile housing design. mounted on ceiling / false ceiling with Regular 100mm base. IP Rating : IP - 42 using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Honeywell)(SR) |
| 479 | Supply, installation, testing and commissioning of Conventional type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication - (Make: Honeywell)(SR) |
| 480 | Supply, installation, testing and commissioning of Addressable Manual Call Point - Resettable type - with back box with Binary coded address setting with Status LED for 360° visibility - IP:50 Rating providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Honeywell)(Sr) |
| 481 | Supply installation, testing and commissioningof Fault isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected -(Make: Honeywell)(SR) |
| 482 | Supply and fixing of 24VDC Power Supply with 5 amp rating,shall provide the supplies to Beam detector / Conventional Sounders / Strobe, Shall have LED indications for Power supply ON,battery Fail,Battery Charging etc,Shall have inbuilt battery charging circuit. (SR) |
| 483 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Civil SOR RATE) (Item No.M-0773) (Make: Polycab)(SR) |
| 484 | Supply and installation of GI Perforated cable tray from the wall / ceiling. The cable tray shall be fabricated in standard length of 2.5 meter of size 2 mm thick 600mm width x 50 mm height with cover suitable supporting arrangements shall be provided at equal intervals with suitable clamps from the wall / ceiling while erecting the cable tray. Jointing of cable trays shall be with fish plates to match the dimension of the cable tray. Fixing both for the jointing of the tray and fixing of the trays on the structure shall be with Thread Rod or approved type of corrosion resistant fixtures. Where necessary, GI bends, tees, reducers, cross members, clamps, hot dipped galvanised iron angle of suitable size, anchor bolts, steel bolts etc., shall be provided by the contractor. GI cable trays shall be heavy duty material shall be both acid resistant as well as corrosion resistant to saline atmosphere. Trays laid inHorizontal/ vertical |
| 485 | configuration should be provided with flat rungs with spacing of 300 mm and side rails of sufficient strength to ensure no damage during the stipulated life. The cables placed in Horizontal/ vertical trays shall be held in position by using proper type of clamp arrangement so that the same do not rest on the side rails during laying or service life.. The side runner will also have suitable holes at every metre for cleating earthing strip. |
| 486 | Suitable tapped holes shall be provided on the runner top and bottom for supporting and fixing tray covers at every metre. |
| 487 | OUTDOOR RMG :- Supply, Erection, testing and commissioning of 11KV 25 KA 630Amps 3 Panel HT INDOOR RING MAIN GEAR Switch board suitable for Indoor installation comprising two incomer Load break switches panels and one outgoing 11 kv HT Vacuum Circuit Breaker complete as per TANGEDCO specification with Mechanical inter lock between incomers.1.Supply and Erection of Draw out type 11KV 25KA 630Amps Horizontal draw out / Horizontal Isolation VACCUM CIRCUIT BREAKER filled with motor(230V AC) operated spring charged Mechanism, with ON and OFF mechanicalIndicator Anti Pumping Device, 110V DC Shunt Trip and Closing Coils (DC source of supply to be derived from a power pack suitable for three Tripping and two closing operations incorporated on Incoming panel only) Mechanical Operation counter, 4NO + NC Spare Aux. Contact with contact multiplication Contactor for customer use. Automatic |
| 488 | safety shutter, Mechanical close/Trip Knob, Mechanical ON/OFF Indication, Operating Handle, 230V AC to 110V DC Power pack operating Handle etc.-1No2. Supply and erection of 11KV 630Amps 25KA HT Air Break/Load Break Switch with mechanically inter locked earth switch, front operated spring assisted manual closing mechanism , 2 NO+ 2NC Aux. Contact operating handle etc.-1No 3. 11KV/Root 3/110V/Root3-Three Phase 3 Limb 50VA class0.5 Resin cast Draw out type potential Transformer complete with HT and LT HRC fuses with sealing arrangement-3 Nos. 4. Current Transformer of Suitable Ratio/5-5A dual Core (Core 1-5VA Class 0.5 for Metering & Core 15 VA 5P 20 for Protection - 3 Nos 5. Meters: Analog ammeter with 5 position selector switch -1 No Analog Voltmeter with selector switch-1 No cut out provision to receive digital Trivector Meter L&T or secure tobe provided.6. Protection: MCDG 61 TP ND IDMT two over current and one earth fault Relay with higher set Instt. Elements 1.3 |
| 489 | Seconds-1 No Master Trip relay Mega win MVAJH 13eqivalent-1 No 7.Breaker On/Off indication LED Type-2 No Auto Trip/ Healthy Trip and spring charges indication LED type-3 Nos phase indicating Lamps RYB - 3Nos8.TNC Breaker Control Switch -1 No local Remote selectorswitch- 1 No Push button for trip Healthy- 1 No 9. Necessary Control wiring with Copper wire10. 630Amps Copper Bus bar PVC sleeved & required panel Earthing 11. Common for Switch gear MCB's for AC/DC Control Heater ON/OFF switch with space Heater and thermostat, single phases switch socket, cubicle illumination TL lamp, Door switch fullycovered Test Terminal block of IMP make (wherever applicable) |
| 490 | 12.MS Sheet steel Enclosure for outdoor Installations powdercoated with siemens Grey paint finish 13. Provision through bottom entry to receive Incomer &Out going cable excluding cable glands and cable Termination Kit. |
| 491 | Five panel HT VCB:- Design, manufacturing supply, erection, testing, commissioning and handling over of 11KV 25 KA HT Five panel Vacuum Circuit Breaker Switch Board Comprising one number 630A 500MVA VCB as incoming and 4Nos. 630A 500MVA VCB as outgoing panels for outdoor installation each panelcomprising. 1) Draw out type 11KV 500MVA 630A Horizontal Draw out/ Horizontal Isolation Vacuum Circuit Breaker operated with Spring charged mechanism. Anti Pumping Device,110V DC shunt Trip and closing Coils (DC source of supply to be derived from a Power Pack suitable for 3 Tripping and Two closing operation counter, 4 NO + 4NC spare Aux. contact for customer use, Automatic safety shutter, Mechanical Close / Trip knob, Mechanical ON/OFF indication, Operating Handle, 110V AC - 110V DC Power Pack etc. (Incoming 1 No. Outgoing 4 Nos.) 2) 11KV /Root 3/110V/Root 3 - Three Phase, 3 Limb 200V A Class 1 Resin Cast Draw Out type Potential transformers complete with HT and LT HRC fuses. (Incoming - 1 No.) 3) Current Transformers of 240 - 50/5-5 Amps. Dual Core. |
| 492 | (Core 1 - 15 VA class 1 for metering and core 2 - 15 VA 5P 10 for Protection) Incoming 4 Nos, Current Transformers of 60/5-5 Amps Dual Core (Core 1-15VA Class 1 for Metering and Core 2 - 15VA 5P 10 for Protection) (Outgoing 4Nos) 4) Meters : Digital Ammeter with Selector Switch (Incoming 1 No. Outgoing 4Nos Digital Voltmeter with Selector Switch (Incoming 1 No.) Digital Trivector of L&T / Secure make (Incoming 1 No.) Digital power Factor meter (Incoming 1 No.) Digital Frequency Meter (Incoming 1 No) 5) |
| 493 | Protection : TP ND IDMT 2 OC + 1 EF R with Highest inst. Elements similar like Megawin type MCDG 61. (Incoming 1 No) 6) TP ND IDMT 2 OC + 1 EF Relay similar like Megawin type MCDG31 Master trip Replay Megawin MVAJH 13 (Incoming 1 No.Outgoing 4 Nos) 7) Breaker ON/OFF/Auto Trip/Healthy Trip/Spring charged Indication lamp LED type (Incoming 5 Nos. Outgoing 20 Nos) 8) Phase Indicating Lamps R,Y and B (Incoming 3 Nos) 9) Control Wiring 10) 800Amps Aluminium Bus Bar PVC sleeved and required panel copper Earthing. 11) Control Switch TNC (Incoming 1 No. Outgoing 4 No.) 12) Trip Circuit Healthy Push Button (Incoming 1 No. Outgoing 4 No.) 13) Common for Switch gear, MCB's for AC DC Control, Heater ON/OFF Switch with space Heater and thermostat single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc. |
| 494 | 14) MS sheet enclosure for Indoor Installation Powder Coated with paint shade siemens Grey, paint finish Provision through Bottom entry to receive Incoming and Out going cable excluding cable glands and cable termination kit. (Make : system control / Siemens) |
| 495 | Supply and clamping of 11KV 3 Core 300 Sqmm XLPE UG cable on a wall with special type of MS Clamp with necessary scaffolding arrangement and laying the HT Cable. (Make: Polycab / RR / KEI) (From Existing FP VCB to New FP VCB) |
| 496 | Supply and providing cable end termination suitable for 11KV 3 core 300 sq.mm XLPE HTUG cable with necessary indoor type heat / cold shinkable joint kit and accessories. (Make: RayChem) (in existing FP VCB o/g 3 - 1 No. and New FP VCB Incomer -1 No) |
| 497 | Supply, erection, testing and commissioning of 1000 KVA/ 11KV / 433V off load tap changing copper wound Indoor Dry Type CastResin Transformer confirming to IS-2026 (Part-11) standard and fitted with the following :a) HV side Cable end box for connecting 1R of 300 Sq.mm. HT XLPE Cable.b) LT side Bus-Duct box suitable for connecting Busbarsc)SERVICE AND COOLING INDOOR / ANd) Copper Wound HV & LV Windinge) RATED VOLTAGE OF HV ( ON NO LOAD ) VOLT 11000f) RATED VOLTAGE OF LV ( ON NO LOAD ) VOLT 433g) CLASS OF INSULATION Fh) TEMPERATURE RISE of WINDING `C' 100i) MAXIMUM AMBIENT TEMPERATURE `C' 40j) RATED FREQUENCY C/S 50k) NUMBER OF PHASE 3CONNECTIONS:-HIGH VOLTAGE : DELTA LOW VOLTAGE : STARVECTOR GROUP REFERENCE : Dyn11TAPPINGS:-Type of Tap Changer : Off Circuit Tap LinksTapping on Primary Side : +5% to -5% in step of 2.5% |
| 498 | IMPEDANCE VOLTAGE AT 75 deg `C'REACTANCE AT RATED CURRENT : 4.90RESISTANCE AT RATED CURRENT : 0.98STANDARD FITTINGa) Rating And Diagram Plate.b) Earthing Terminal.c) Lifting Lungs.d) Bi-Directional Rollers.e) WTI Scanner.f) Primary Bushing.g) Secondary Bushing.h) Marshalling Box. Data-30 |
| 499 | Design, Supply, erection, testing and Commissioning of 1 No. Outdoor Type ACB Kiosk for Transformer Incomer comprising of 1 No. of 2500A LT Air Circuit Breaker (ACB) is a heavy-duty, low-voltage protection device designed to safeguard electrical distribution systems up to 690V AC. It is engineered to handle large currents with high reliability and is typically used as an incomer or main breaker in LT panels such as PCC, MCC, DG synchronizing panels, and capacitor panels. The breaker is constructed with a robust arc-quenching chamber that ensures rapid interruption of fault currents, minimizing damage to equipment. The 2500A ACB generally features with draw able or fixed-mounted design, allowing easy maintenance and safe isolation during servicing. It is equipped with a microprocessor-based release (electronic trip unit) that provides adjustable protection functions including long-time (L), short-time (S), instantaneous (I), and ground/earth fault (G) protections. These settings allow precise coordination with downstream protection devices, ensuring selective tripping and system stability. |
| 500 | The ACB is designed for high breaking capacities, typically ranging from 50 kA to 65 kA (or as per IEC 60947-2 standards), offering robust protection against severe short-circuit conditions. Additional features include shunt trip, under-voltage release, motorized spring-charging mechanism, mechanical interlocks, closing and opening coils, and a mechanical indicator for ON/OFF/TRIP status. The breaker also incorporates auxiliary contacts for remote monitoring and control, and may offer communication capabilities such as Modbus or Ethernet for integration with SCADA or energy management systems. Thermal performance is optimized with silver-plated contacts and efficient heat dissipation design to ensure continuous operation at 2500A without overheating. The breaker’s insulation system is designed for high dielectric strength, ensuring safe operation even under harsh environmental conditions |
| 501 | Design, Supply, erection, testing and commissioning of 400A floor / Wall mounted MV cubical panel board suitable for operation on 415 V 3 phase, 50 Hz A.C supply, dust and vermin proof and accommodating the following Switches as Incomer unit with the following items of work complete to satisfy the latest IE rules and CEIG guidelines with Bus bar chambers, Main switches chambers and cable entry chambers. Bus bar chamber:Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet teel (1.8mm) with 4Nos. 3” X 1/2” (75 mm x 12 mm) aluminium Main bus bar for 3 phases and neutral and2 Nos. of earth bus of size 1” X 1/4\\" aluminium bus on suitable bus bar insulator (Epoxy insulator) with maximum creepage distance and supported on MS Base channel frame work Main Switches Chamber:Incoming1)Supply and fixing of 2 Nos. 400 A 4 pole 433V MCCBwith Spreader termial and Operating Handle.Outgoing1) 250A Four Pole MCCB - 2 Nos2)125A Four Pole MCCB - 5 Nos 3) 100 Amps 4 Pole MCCB - 1 NoCable Chamber :The Cable chamber should be accommodating 1 Run 3.5 x 240 Sq.mm Cable as incoming for Incomer Instrument chamber : |
| 502 | A Separate chamber on Top of one side should be built with (0- 500 V) Voltmeter (0-600A) Ammeter with C.T and selector switches with one Set of LED pilot lamps Set withfuse base, top with 5A HRC link for 3 phases, 1 Set of Earth Fault relay for protection, Mains CTs for 3 phases lockout, features, separate mold base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules in force with inter connection and terminations as required.Supply and fixing of danger board with Siemens greypowder coating with super scribing the names of places to which supply is fed feeder sizes of cables direction of cables etc. Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel, concreting, testing and commissioning (L&T, SIEMENS, ABB) (DATA-38) |
| 503 | MV PANEL BOARD:- Design, Supply, erection, testing and commissioning of 3200A floor mounted MV cubical panel board bus bar chamber dust and vermin proof and accommodating the following ACB's 2 Nos.3200A EDO ACB as Incomer units with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos ie R,Y,B,N. 4 runs of 100 mm x 12 mm” aluminium bus bar for 3 phases and neutral and 2 Nos. of earthing bus of size 2”X 1/2\\" aluminium bus on suitable bus bar insulator (Epoxy insulator)With maximum creepage distance and supported on MS Base channel frame work of size 4” X 2”X ¼ - 1Set (100mm x 50mm x 6mm) Incoming :1) Supply and fixing of 2 Nos. 3200A basic rating 4 pole 433V LT EDO ACB confirming to IS 13947 – 2 IEC 60947 – 2 for higher breaking capacities of 65KA at 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with micro processor SR 18 G relay, |
| 504 | over current trip device adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with interconnection and terminations as required in specification. BUS COUPLER:- Supply and fixing of 1 No 3200A basic rating 4 pole 433 V LT EDO ACB incoming to IS-13947-21EC60947-690VAC 65KA with all accessories for standard horizontal type ACB equipped with micro processor based SR18G. Outgoing: 1) Supply and fixing of 1250A 4 Pole 65 Ka Drawout type EDO ACB - 4 Nos 2) Supply and fixing of 400A 3 Pole MCCB with Rotary handle, Spreader link - 2 Nos. 3) Supply and fixing of 630A 4 Pole 50 Ka Drawout type EDO ACB - 2 Nos. 4) 2) Supply and fixing of 250A 3 Pole MCCB with Rotary handle, Spreader link - 2 Nos. |
| 505 | 4). Advanced Multifunction meter 13 Nos Inter connecting the all LT ACB’s and MCCBs to two bus bar with suitable insulated tinned copper flats and painting of phases and neutral indication. Double Earth connection of the MCCBs and ACB’s to suitable earth bus. Supply and fixing of LED lamp arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments with in the cubicle by CEIG rules with, 2 sets, of supply and fixing Electronic Trivector EC, 300P class 0.5 Base mounting L&T or equivalent.(Make–Model. ER300P class 0.5) Supply and fixing of suitable CT Coil for all ACB incomer's and Outgoings, supply and fixing of danger board with siemens grey powder coating with super scribing the names of places to which supply is fed feeder sizes of cables direction of cables etc.Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel,concreting, testing and commissioning (L&T/Siemens/ABB) protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mold base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules in force with inter connection and terminations as required in specification. |
| 506 | Design, Supply, erection, testing and commissioning of 2000 A draw out type floor mounted MV cubical panel board suitable for operation on 415 V 3 phase, 50 Hz A.C supply, dust and vermin proof and accommodating the following Switches and 2 Nos. of ACB as Incomer unit withthe following items of work complete to satisfy the latestlatest IE rules and CEIG guidelines with Bus bar chambers, Main switches chambers and cable entry chambers.Bus bar chamber:Supply and fixing of suitable bus bar chamber made up of16SWG MS sheet steel with 4Nos. 100x12mmx2 Runs of Aluminium Busbar for 3 phases and 100x 12 mm x 1 Runsof Aluminium Busbar for neutral and for earth bus of size 50 x 10 mm on suitable bus bar insulator (Epoxy insulator)with maximum creepage distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1SetIncoming :1)Supply and fixing of 1 Nos. 2000 A 4 pole 433V LT ACB confirming to IS13947–2 IEC 60947–2 with suitable capacity and breaking capacity of drawout 65 KA breakingcapacity with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and openingoperation with Microprocessor Based SR 18 G relay, over current trip device adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, |
| 507 | Mains CTs for 3 phases lockout, features, separate mold base for each pole foreasy maintenance all relevant protection safety accessories as per CEIG, IE rules in force with inter connection and terminations as required in specificationOutgoing :a) Supply & fixing of 1250 A 4 Pole ACB — 3 Nosb) Supply & fixing of 400 A 4 Pole MCCB — 4 Nos c) Supply & fixing of 250 A 4 Pole MCCB — 8 Nos Inter connecting the all LT ACB’s and Switches to bus barwith suitable insulated tinned copper flats and painting/ PVC sleeve colour coding of phases and neutral indication. Double Earth connection of the switches and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8”. Supply and fixing of RYB LED lamp arrangements with toggle switches to control each phases and with rigid connection in suitable separate compartments within the cubicle as per CEIG rules, Danger board with Siemens grey powder coating with super scribing the names of places to which supply isfed feeder sizes of cables direction of cables etc., including Erection of panel board complete with suitablefoundation bolts and nuts including suitable M.S Channel, concreting ,testing and commissioning (L&T, SIEMENS,ABB) |
| 508 | Supply and fixing of end feed unit 1600A 4Pole MCCB with enclosure with one set of spreader terminals and Operating handle with necessary cable top up box, including 50mm x10mm aluminium flat interconnection between the Raising main bus-bar to 400A 4P MCCB terminal complete earth connection etc. |
| 509 | Making new end termination for 400 Sq.mm LT UG Cable from busduct to chiller in top floor with necessary Busbar extension for accommodating 3 Runs. |
| 510 | Bus ducts: 1600ADesign Fabrication, Supply erection, testing andcommissioning of 1600 Amps Bus Duct of existing size 6 x1/2\\" Aluminium Busbars with enclosures to be coupledwith L Bend between the existing Incomer from the Main MV panel to the Chiller Rising Main with necessary Angle iron supports, suitable for operation on 415 V 3 phase, 50Hz A.C supply, dust and vermin proof and accommodating the following items of work complete to satisfy the latest IE rules and CEIG guidelines, as required at site. |
| 511 | Supply and fixing of end feed unit 1600A 4Pole MCCB with enclosure with one set of spreader terminals and Operating handle with necessary cable top up box, including 50mm x10mm aluminium flat interconnection between the Raising main bus-bar to 400A 4P MCCB terminal complete earth connection etc. |
| 512 | supply and fixing of flange units for raising mains |
| 513 | Supply and erection of 300 kVAr APFCR panel consists of a total capacitor capacity of 300 kVAr typically divided into multiple steps such as 50 kVAr (six steps) and 25 kVAr (four steps), each supplied with heavy-duty APP/MKP capacitors equipped with built-in discharge resistors. Every capacitor step is paired with a detuned reactor of 5–7% tuning to protect the capacitor bank from harmonics and ensure stable operation. Switching of these capacitor banks is accomplished through APFC-duty contactors or optional thyristor switching modules, one for each step, along with auxiliary contacts. The panel includes a 12-step APFC/APFCR controller capable of automatic power factor correction with programmable PF targets, along with a multifunction meter for monitoring voltage, current, power factor, THD, and energy parameters. Suitable CTs (Class 1 or better) are provided for sensing, and a PT is included if required for medium-voltage inputs. |
| 514 | Protection devices include an MCCB as the incomer (typically 400–630 A depending on system load), individual MCCBs/MCBs for each capacitor step, HRC fuses for capacitor protection, a Class II surge protection device, and a control transformer of 1–2 kVA for auxiliary circuits. The panel is fabricated from powder-coated MS sheets (14/16 SWG), with proper ventilation through thermostatically controlled cooling fans, and contains copper busbars of adequate ampacity, FRLS internal wiring, indicator lamps, selector switches for Auto/Manual operation, space heaters with thermostats, and appropriate cable glands and lugs. The assembly also includes nameplates, ferruling, internal structural supports, and earthing busbars. |
| 515 | Supply and installation of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS |
| 516 | Supply and Providing approved make First Aid Box complete with all First Aid Medicines |
| 517 | Supply and providing shock treatment chart fixed in glass frame (Tamil and English) |
| 518 | Supply and fixing of the 4nos fire buckets stand suitable for 4 nos fire buckets made out of 40 x 40 x6mm MS angle |
| 519 | Supply of hand gloves 11 KV grade |
| 520 | Supply and installation of Danger Board as required by the electrical authorities |
| 521 | Supply and erection of Fire extinguisher Co2, 4.5 Kg confirming to TAC norms |
| 522 | Telescopic Earth Rod extendable type per set (Material - PVC Pipe, 1 Set of 3 Nos, Size 4 Feet) (Distribution type) |
| 523 | Provision towards preparation of site plan, physical layout, electrical line schematic diagram HT side ,5 sets getting drawing approval from CEIG authority (Measures safety to electricity) regulation, preparation of completion report ,Rectification report, preparation of one set approved drawing and copy of safety certificate in a neat frame work and payment of CEIG 's inspection fees including supporting staff for availing service connection. for HT, LT, GENSET and Lift |
| 524 | Supply, erection ,testing and commissioning of indoor IP 55 Protection 1250A capacity vermin dust proof cubical of 14SWG line quality MS sheet steel enclosures for accommodating the 1250A TPN copper busbar and busduct of 2.5” x 1/2” copper busbar 3 phases and neutral earth bus bar copper of 2 Nos 2 run 1” x 1/4” with sealing the interconnection of bus bar chamber using Gaskets made from materials like silicone or rubber are used to seal joints and openings, ensuring no dust or water can penetrate the enclosure. |
| 525 | Supply and fixing of 250 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double brEak on suitable angle iron frame work with MS cable entry boxes with Earth connection only. |
| 526 | Supply, erection, testing and commissioning of 400A 4 pole MCCB switch tapoff box on existing rising main with suitable 14SWG MS sheet steel enclosure for accomodating Copper bus bar of 1\\"x1/4\\" three phase and neutral bus bar with interconnection with 1250A rising mains with suitable earth connection. |
| 527 | Supply and clarnping of 2 run 31/2 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 528 | Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection |
| 529 | Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 530 | Supply and clarnping of 3½ x185 sq.mm PVC LTUG armored LTUG cable on post or on wall/existing trench with MS Clamps. (Polycab / RR / KEI) |
| 531 | Supply, erection ,testing and commissioning of 3 KVA UPS system (Signal phase input & Signal phase output) 2 hours back- up for the following configuration. 1) True ON LINE –UPS SYSTEMS with Pulse width modulation (PWM) Technology using IGBT Inverter. 2) INPUT VOLTAGE RANGE : 230V 3)OUTPUT VOLTAGE : 230V ± 1% 4)DC Volt:120V 5)INPUT FREQUENCY : 50Hz ± 5% 6)Out put Frequency: 50Hz ± 2% 7) Out put Waveform:Pure Sine Wave 8) LOAD POWER FACTOR : 0.8 to Unity 9)HarmonicDistoration: Less than 5% 10)Over Load: : 125% for 10Minutes 11)Inverter Operation : PWM-IGBT 12)Invertor Efficience : Better Than 90% 13)OPERATING TEMPERATURE : 0 to 50 Degrees centigrade’s on Full Load 14)Digital Panel Meter : To Read output A/C Volts,Output D/C Volts Frequency 15)By pass : Manual 16)PROTECTION (INBUILT) : a. Output Under Voltage b. Output Over Voltage c. Output Overload d. Output Short Circuit e. HRC Fuses, Output & Battery f. Battery Low trip g. Battery Charging Current Limit. 17)INDICATIONS : 1. Mains On, 2. Inverter On, 3. Load on U.P.S. 5. Battery Low 6.Over load 7.Inverter Trip. (FOR RMG ROOM) |
| 532 | Supply and providing of Plate earthing electrode with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry work. |
| 533 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. |
| 534 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. |
| 535 | Supply and run of 25mm x 3mm copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 536 | Supply and run of 25mm x 6mm copper flat with necessary clamps / supports on wall / floor / ground for earth connection. |
| 537 | Supply, Erection, Testing & Commissioning of 300 TR Chiller Plant. |
| 538 | Supply and fixing of 40HP Chiller Pump with VFD. |
| 539 | Supply and fixing of 40HP Condenser Pump with VFD. |
| 540 | Supply and fixing of 12\\" chiller main pipe line |
| 541 | Supply and fixing of 10\\" chiller inlet & outlet pipe line. |
| 542 | Supply and fixing of 8\\" chiller pipe line for Terrace area. |
| 543 | Supply and fixing of 6\\" chiller pipe line for Shaft area. |
| 544 | Supply and fixing of 4\\" chiller pipe line for Floor area. |
| 545 | Supply and fixing of 3\\" chiller pipe line for Floor area. |
| 546 | Supply and fixing of 2 1/2\\" chiller pipe line for AHU tapping. |
| 547 | Supply and fixing of 2\\" chiller pipe line for AHU connection. |
| 548 | Supply and fixing of 4\\" cooling tower pipe line. |
| 549 | Supply and fixing of chilled water pipe line insulation with Aluminium cladding in all area. |
| 550 | Supply and fixing of 12\\" Butterfly valve with Flange set. |
| 551 | Supply and fixing of 10\\" Butterfly valve with Flange set. |
| 552 | Supply and fixing of 8\\" Butterfly valve with Flange set. |
| 553 | Supply and fixing of 6\\" Butterfly valve with Flange set. |
| 554 | Supply and fixing of 4\\" Butterfly valve with Flange set. |
| 555 | Supply and fixing of 3\\" Butterfly valve with Flange set. |
| 556 | Supply and fixing of 2\\" Butterfly valve with Flange set for AHU. |
| 557 | Supply and fixing of 3way Accelerator valve for AHU. |
| 558 | Supply and fixing of 2way Accelerator valve. |
| 559 | Supply and fixing of 1\\" Butterfly valve with Flange set for FCU. |
| 560 | Supply, Erection, Testing & Commissioning of 8.5 TR Double skin Air Handling units made of 25 mm thick puf panel with thermal break profiles, forward curved fans, Motors of Class \\"F\\" insulation ; DX cooling coils with aluminium fins and copper tubes. |
| 561 | Supply, Erection, Testing & Commissioning of 11.0 TR Double skin Air Handling units made of 25 mm thick puf panel with thermal break profiles, forward curved fans, Motors of Class \\"F\\" insulation ; DX cooling coils with aluminium fins and copper tubes. |
| 562 | Starter Panel for AHU: Supply installation testing and commissioning of DOL Starter Panel for following capacity with all standard accessories complete. |
| 563 | Supply and fixing of suitable MS angle frame for mounting the indoor units. |
| 564 | Supply and filling of R-407C Refrigerant gas. |
| 565 | Supply and fixing of flexible canvas connection between indoor unit and ducting. |
| 566 | Supply, Fabrication and erection of fabricated ducting made up of GI sheets of complete with MS angle supports angle flanges, anchor fastess, tees and bends where ever necessary etc as required. |
| 567 | a) 20 gauge Sheet |
| 568 | b) 22 gauge Sheet |
| 569 | c) 24 gauge sheet |
| 570 | Supply, fabrication and Erection of Angle Frame for Ducting. |
| 571 | Supply and fixing of extruded aluminum powder coated supply and return air grilles with volume control damper. |
| 572 | Supply and fixing of water drain pipe line (1 inch PVC pipe) |
| 573 | Supply and fixing of duct mouth damper. |
| 574 | Supply and providing acoustic for initial portion of ducting with 12mm thick fiber glass rigid board covered with tissue paper and aluminum perforated sheet. |
| 575 | Supply and providing thermal insulation of 9mm thick vidoflex with aluminum foil. |
| 576 | Supply and providing thermal insulation for Refrigerant Pipe and Drain Pipes. |
| 577 | Lifting, Shifting & Scoffolding Charges for AC |
| 578 | Wall opening for Supply Air Duct and Refrigerant Copper Pipes with Labour work charges. |
| 579 | Supply and providing of power supply for indoor to outdoor unit motors for 6 Sqmm 4 Core copper flexible single cable |
| 580 | Supply and providing of control supply for indoor to outdoor unit Hp and Lp cut outs for 1.5Sq mm 6 core copper flexible cable |
| 581 | Supply and providing of Laminar air flow with HEPA filters for all Operation theatres & Cathlab |
| 582 | Supply of 8.5 TR capacity air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector,internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations. |
| 583 | Supply of 11.0 TR capacity air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector,internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations. |
| 584 | Supply and fixing of hard drawn copper refrigerant piping of 1 1/8\\" dia,interconnecting indoor and outdoor units with necessary fittings,supports etc. |
| 585 | Supply and fixing of hard drawn copper refrigerant piping of 7/8\\" dia,interconnecting indoor and outdoor units with necessary fittings,supports etc. |
| 586 | Supply and installation of 2.0 TR capacity 3 star rated energy efficient Hi wall mounting Split type Air Conditioner unit consisting of out door condensing unit complete with hermetically sealed Air compressor with R 22 refrigerant air cooled condenser, fan etc., and 1No Indoor Hi wall mounted 2.0 TR capacity evaporator unit complete with cooling coil, blower motor and connected accessories, control etc, with 3 metre copper refrigerant piping and chord wire connecting indoor and out door unit with drain pipe suitable for operation on 230V+ 10% 50 HZ single phase AC supply.(Make: Carrier/Equ) |
| 587 | Supply and fixing of 5KVA Automatic voltage stabilizer with time delay arrangements for operation on 230V 50C/S AC supply ( Make V Guard/Equ) |
| 588 | Supply and laying of 5/8” and 3/8” copper with 3 core cord wire and insulation etc., (beyond the standard length of 3mts) |
| 589 | Supply and fixing of out door base stand for split AC unit |
| 590 | UNIDIRECTIONAL LAMINAR AIR FLOW SYSTEM :The ceiling Laminar air fow filtration system (HEPA Filter - 8ft x 8ft LAF with HEPA) shall be designed to ensure unidirectional distribution of sterile air in the surgical theatre to ensure cleanliness of all the area covered by the air flow.The laminar flow system shall comprise of thick extruded aluminium profiles frame with sealed gasket and it should be made of SS-304/Aluminium Cabinet and SS-304 perforated grill. The filters installed in the plenum shall be suitable for application for laminar flow and clean rooms. These filters shall meet following specifications: Separators: Continuous thermo plastic chord, Sealant: Polyurethane,Gasket: One-piece polyurethane, MPPS average efficiency: > 99.97%, 0.33 Micron DOPefficiency:> 99.99%, Final pressure drop: 600 Pa (maximum), Maximum operating temperature: 600°C, RH: 40- 60%, The ceiling system shall be equipped with “H 14” class HEPA filters positioned in the ceiling to achieve 0.25 m/s flow at the diffuser. Filtration ceiling system holding structure, filter frames and top plenum shall be made of aluminium/stainless steel. The filtration ceiling system shall have diffuser/flow equalizer to achieve uniform and constant air distribution over the whole surface. The air management system shall be designed to achieve Class 100 Cleanliness with the following parameters: Bacteriological class=B (5 CFU/m3), Particle decontamination kinetics CP=5 minute, ISO 14644 /1 or latest classification= ISO 5, Third party validation shall be obtained. Positive pressure shall be maintained inside the MOT to prevent contamination due to air from outside. The supplier shall provide test certificate for HEPA filter and laminar air flow systems from the original manufacturers. According to the site condition split type LAF may be required. Excluding Main power supply cabling for Modular OT Distribution Boards, Online UPS input power supply etc should be done by Suitable multicore FRLS copper cabling as per the load and design.As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 591 | ALUMINIUM DUCTING WITH ALUMINIUM FOILED XLPE THERMAL INSULATION:22 GAUGE / 20 GAUGE Aluminium sheets conforming to IS:737-1955. The ducting shall be tested for any kind of leakages.All ducting shall be applied with food grade RTV sealant on joints. All duct work shall be with Aluminum only and cross section shall be rectangular. Duct routing should be straight with minimum deviations as far as possible. sheet thickness of the ducting shall be 20/ 22 gauges and fabrication, installation should be as per the SMACNA standards. Sheet metal work shall be with good quality workman ship using right engineering practices. Contractor shall prepare all working drawings and duct routing layout. Approval from the HLL shall be obtained before commencing the work. Extract panels with inbuilt ducts are envisaged for return air from the clean room. This extract panel will get connected to the return air duct network above false ceiling and finally to the AHU. It is essential to provide straightening vanes wherever there is a duct collar joint for a proper balancing of air distribution. When there is change in duct size in a continuous run transformation duct pieces have to be used. Normal slope shall be one in seven. Elbows shall have radius ratio 1.5 and maximum aspect ratio not more than six. Aspect ratio of rectangular duct should be within 4. In case of shorter elbows or sharp bends multiple turning vanes has to be used. Branch duct from a main duct (after an elbow) should be away at least 7.5 times of the elbow width. Ducts with thermal insulation shall be suspended from the roof slab using GI hi – tech support system with threaded rods and slotted strips. The internal ducts should be insulated by the 13 mm thk XLPE and external ducts should be insulated by the 19 mm XLPE with anti bacterial property and it should be class 0 . Cost of above supports shall be included in the item under duct in the BOQ. Return Air Risers: Return air risers are proposed to be constructed in integral with modular panels. Riser shall be provided with suitable SS-304 return air grille and Aluminium collar damper.As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 592 | Fire dampers: Fire dampers shall be provided with AHU unit matching with the inlet / outlet damper size and shall be of mechiacnal type with fusible link at burst temperature of 58 Deg C. Proper test certificate shall be provided for the same. The damper shall have indication for open/ closed condition. The fire damper shall be of 16 Gauge Aluminum construction . AHU Mouth Dampers: Mouth dampers shall be provided with AHU unit matching with the inlet / outlet damper size and shall be of mechiacnal type, zero leakage, Proper test certificate shall be provided for the same. The damper shall have indication for open/ closed condition. The Mouth damper shall be of 16 Gauge Aluminum construction . Volume Control Damper: Volume control dampers shall be match with the duct size and shall be of mechiacnal type, zero leakage, Proper test certificate shall be provided for the same. The damper shall have indication for open/ closed condition. The VCD shall be of 16 Gauge Aluminum construction . Collar Damper: Collar dampers shall be match with the Supply air and return air opening size and shall be of mechiacnal type, zero leakage, Proper test certificate shall be provided for the same. The damper shall have indication for open/ closed condition. The collar damper shall be of 18 Gauge Aluminum construction . Pressure relief Damper: PRD having multi 304 grade stainless steel blade to maintain positive air pressure inside the OT. Pressure Relief Dampers will be CE/ISO certified and in compliance under Class 1 Medical devices. All rates include NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 593 | HYGIENIC AIR HANDLING UNIT: (AHU - 11 TR - 4500 CFM - 100mm)Hygienic Air Conditioning unit with 0.6mm thick powder coated outer skin, 1mm thick plain aluminum inner skin, frame constructed with 50mm +/- 2 mm thick insulated panels with thermal break profile, , drain pan made out of SS-304, Horizontal floor stand type unit with the base made by1.6 mm thick GI channel. The evaporating coil should be made of plain aluminum casing and blank off, Coils with inner grooved copper tubes, Aluminum fins, Copper header, Twin circuit, cross flow type (interlaced), 12-14 fins per inch. 3 level filtration ie. 20 micron pre filters for fresh air intake, 10 micron pre filter for return air mouth, 5 micron flat fine filter for Supply side, Kruger / Nicotra make blower, backward curved with required CFM, Cooling capacity and TSP. ABB / CG/ Marathon/ Hawells electric motor, Aluminum Dampers for fresh air intake with Aluminum bird screen & cowl, aluminum damper for return air and supply air, Fire damper made out of aluminum with sprig return arrangements. There should not be any condensation on AHU Body & Sound from AHU should not be more than 60 dB according to NABH Guideline. The pressure damper in the unit to get desired level of fresh air & to maintain positive pressure inside the operation theatre. Air recirculation to keep operation theater air more sterile & less load on air conditioning. Should have CFM flow to get minimum 20 air cycle/hour to minimize biological burden and suffocation. The AHU system should have humidistat and heaters with suitable capacity (Kw) incorporated inside AHU to control in desired level as per NABH. The AHU system should have Thermostat to get desired temperature in operation theatre. UV light will do not allow fungus to grow in cooling coils in ppsc and ensure sterile air. Air particle count should be Class 100 in beneath of LAF , Class 1000 in 1 foot distance from laf, class 10000 on table and class 1 lakh in any corner of the operation theater. Copper refrigerant piping: Hard drawn copper piping should be layed between indoor and out door pary with suitable tray supports and 13 mm thk nitrile rubber tubular insualtion along with the the synthetic taping and poly shield coating. The pipe size should be as per the manufacturer's recomendation and the wall thichicness should be not less than 19 Gauge. As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 594 | AHU Control Panel, Temp & Humidity controllers: AHU control panel should be made of 1.2 mm thick powder coated GI steel, hinged door with gasket, it should be suitable for outdoor mounted, IP55 graded, should contains VFD, contactor relay, circuit breakers, timers, On,Off and trip indication for the compressors, blower & heaters, provide thermostat inside OT with on/off control to maitain the temperature from 16 deg C to desired level inside OT. Finned type heaters should be provided along with the humidistat to maintain the Rh between 50% - 60% inside OT. The control panel should have the dispaly of Temp, Rh of OT. As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 595 | DX type Condensing Unit (Twin Circuit): Air cooled type, single circuit, 3 rows, Face area not less than 1 sqm, coil should be made by internally grooved copper tube with 0.355 mm thick, 7.93 mm dia, super slit aluminum fin type with anti corrosion coating, fin pitch should be 13 fins per inch, 2 sqm primary surface area, 36 sqm secondary surface area, 4 deg C sub cooling, mechanical expanded, single phase, 3 speed condenser fan motor, 0.58 HP capacity, 12 mfd burst capacitor, Direct drive, F class insulation, permawick bearings, 60 deg C Over Load Thermal Protection, propeller fan, 508 mm dia, 4 blade and base ASG 20, 55 dBA noise level, green refrigerant(R-410 A / R-407 / R-32), 4950 watts power max., 14000 Kcal/HR cooling capacity , epoxy powder coated on sheet metal parts.Hermetically sealed scroll compressor, Copeland / donfoss make, single compressor, 3 Phase, 380- 420 Volts, 7 Amps, 64 A Locked Rotor Amps, star connection electrical circuit, resilient rubber grommet with steel sleeve, bolt and nuts four sets. As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 596 | Peripheral Lighting: Supply and installation of Clean Room Light Fixture with 2 X 2 Feet LED Light fitting, not less than 40 watts, Recess Mounting, bottom opening, IP54 class, provided with opal polystyrene diffuser as required. Fixing shall be done in modular ceiling.As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. Epoxy White Powder Coated CRCA Housing and High Transmission Non Yellowing PMMA Opal Matt Diffuser is Sealed with CRCA powder coated bottom frame. |
| 597 | Triple Dome Ceiling Suspended LED OT Light with HD CameraThe Operating Theatre Light should comprise of a double structure with 3 lamp heads and two domes having 160000 lux and third dome has 100000 lux with 360-degree rotation in all the arms and light head The lamp heads should have multiple LED light sources including a combination of red and white LEDs to optimize color rendition. The light should provide deep, direct, shadow less Illumination. It should be cool, infrared-free light which prevents tissue from drying out in the operating field. The OT Light system should include the option to adjust the lamp head mounting height by adding modular extensions to the verticals. (These stack up by screwing extra ones on the bottom) The OT light system should include a large, high quality ceiling cover which covers the larger holesinthe ceilings |
| 598 | Inside OT Electrical wiring and conduits: Wiring with Low leakage current wires of FRLS wires as per individual operation theatre requirements including providing and fixing of conducting and boxes inside operation theatres. Wiring for 250 volts single phases and neutral 6 cum16 amps 6 module sockets in all sides of OT wall and 1 no. of 32 amps Industrial socket, MCP with 4 sq. mm 4 core cabling at 1 foot from the finished floor level, wiring with switches for OT accessories, wiring for OT light, Peripheral light, pendants etc including lighting DB and UPS DB outside OT Wall. As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 599 | Power cabling for AHU, Heaters, ODUs and AHU Control Panel, 20 KVA UPS : Suitable multicore FRLS copper cabling should be done along with the necessary cable tray and PVC conduit. The size of the copper cable should be of according to the current and power of the equipment and as per the OEM's recomendation. (16 sqmm x 4 core, 10 sqmm x 4 core ; 6 sqmm x 4 core ; 2.5 sqmm x 4 core). As per NABH / ISO 14644 validation and air balancing certification and warranty upto 3 years including validation, testing & commissioning. |
| 600 | Supply and fixing of 150 W LED street light fitting with LED (higher end) with 40 mm dia. GI pipe (class B) with 1 no. 40 mm dia GI bend complete on the existing post/on wall with 1.5 sq.mm PVC unsheathed FRLS copper leads with MS clamps and with painting. |
| 601 | Design, supply, erection, testing and handing over of 16 Mtrs High Mast Structure Crompton /Havells/Bajaj/make or equivalent with required number of continuously tapered hot dip galvanized steel polygonal sides sections with telescopic strip joints to a total height of 16 meters capable of sustaining the maximum wind pressure at the erection site with single flange base plate secured welded in the bottom of the base mast section with vertically movable hot dip galvanized lantern carriage and accessories such as electrical junction box brackets for providing 8 Nos. of Tango LED flood light luminaries (philips cat no. BVP483 LED29 CW NB A1 PSU GR SPD) complete head frame assembly, Pulley drive, stainless steel wire rope single/double drum self lubricating winch arrangement suitable for raising and lowering the luminaries carriage ring flexible multi core power cable and necessary high tensile hot dipped galvanized foundation, bolt & nuts along with washers and anchor plates and templates including supply and fixing the following accessories in the Mast. |
| 602 | a) Design and casting of suitable foundation with 1:2:4 mix RCC concrete with 30 cm projection above the ground level with 1 metre Width x 1 metre Length and 2.5 metre depth with necessary galvanized 8 Nos foundation bolts nuts and washers and temp plate enclosing the bolts for the High Mast considering the safe soil bearing capacity at site - 1 Job |
| 603 | b) High powered power tool complete with hand held control panel and motor with push button type remote control switch suitablefor 3 phase 415 V 50 HZ for raising and lowering of the lantern carriage complete to operate all fittings mounted in the base to couple with winch - 1 Set |
| 604 | c) Feeder pillar box comprising 0.90 m x 0.45m x 1,20m floor AI frame with 63 A TPN main switch 1 no , 63 A fuse unit 3 nos, 63 A power contactor with automatic timer arrangements and reversing starter for the 3 phase motor - 1 Set. |
| 605 | d) Neon aviation obstruction light(Crompton /equivalent make - 1 No. e) 2 Nos of special GI earth electrodes with copper plate 300 x300 x 3mm and copper flat (1”x1/4”) interconnection as per ISS complete with earth connection - 1 set. |
| 606 | f) Hot dip galvanized lightning arrestor - 1 No. |
| 607 | g) Tango LED Flood light luminaries with single die ceramic base high power LED,PDC housing & Integrated Flood Optics (NB) to ensure uniform distribution maintenance free system,idel for sports lighting, area lighting and high mast lighting provided with 150w LED Light fitting like PHILIPS make cat no. BVP483 LED259 CW NB A1 PSU GR SPD)complete complete as per standard specification. -8 nos |
| 608 | The above Highmast complete all associated works erection ,testing and commissioning in neat alignment wth proper plate earthing complee etc. |
| 609 | Supply and fixing of EPABX system with 8 Trunk line + 30 SIP Trunk + 8 Digital Extension +256 analog Extension Expandable Up to 896 AnalogExtension + 400 IP Port . |
| 610 | Supply and Installation of Caller ID telephone with Speaker. |
| 611 | Supply and Installation of RJ 11 I/O switch with module box and face plate. Make:D-link. |
| 612 | Supply, fixing and termination of 100 pair DB with krone module and necessary connections. |
| 613 | Supply, fixing and termination of 20 pair DB with krone module and necessary connections. |
| 614 | Supply, fixing and termination of 10 pair DB with krone module and necessary connections. |
| 615 | Supply and laying of 0.5mm 20 pair telephone cable with suitable PVC pipe.Make: Delton. |
| 616 | Supply and laying of 0.5mm 10 pair telephone cable with suitable PVC pipe.Make: Delton. |
| 617 | Supply and laying of 0.5mm 2 pair telephone cable with suitable PVC pipe.Make: Delton. |
| 618 | Supply and Installation of 1 KVA ,230 V UPS System with One hour inbuilt battery backup. |
| 619 | Supply and Installation of 9U Rack. |
| 620 | Supply, fixing and termination of RJ45 I/O box with face plate and back box. Make: D-Link |
| 621 | Supply and Installation of 24 Port Fully managed 10/100/1000 Layer-2 with 1G Uplink Switch. |
| 622 | Supply and Installation of 8 Port Fully managed 10/100/1000 Layer-2 with 1G Uplink Switch. |
| 623 | Supply and Installation of 24 Port Un- Mananged 10/100/1000 LAN Network Switches. |
| 624 | Supply and Installation of 24 Port Patch Panel -Fullyloaded. |
| 625 | Supply and Installation of 1 mtr patch Cord. Make: D-Link. |
| 626 | Supply and Installation of 2 mtr Patch Cord. Make: D-link |
| 627 | Supply and Installation of 4U Wall Rack. |
| 628 | Supply and Installation of 600VA,230V, UPS System with One hour inbuilt backup battery. |
| 629 | Supply and Installation of Bullet/Dome Camera. |
| 630 | Supply and Installation of 80-Ch IP NVR, resolution up to 12MP, Dual RJ15 Port, 4 SATA (up to 10TB). 2 HDMI & VGA, 2 USB, Alarm I/O. |
| 631 | Supply and Installation of 24 port POE Switches forr CCTV IP camera. |
| 632 | Supply and Installation of 8TB built in Hard Disc Drive. |
| 633 | Supply and Installation of 65 INCH Professional Display. |
| 634 | Supply and Installation of Wireless Mouse.Make: Dell |
| 635 | Supply and Installation of 20 mtr HDMI Cables. |
| 636 | Supply and laying of CAT 6 cable in existing 1” PVC pipe including numbering and ferruling. Make:D-Link |
| 637 | Supply and laying of 25 mm dia1” PVC pipe on wall and ceiling. |
| 638 | Supply and Installation of 24 Port 10/100/1000 Mbps 24 SFP Port Fully managed switch with two SFP/RJ 45 Combo Ports for high speed Connections. Make: D-Link. |
| 639 | Supply and Installation of LC Dual module Connector forCopper to Optical Conversion.Make: D-Link. |
| 640 | Supply and Laying of 6 Core OFC Oudoor Cable with existing PVC pipe. |
| 641 | Supply and Laying of 50 X 50 mm PVC Truff. |
| 642 | Supply and Installation of PA mixer Amplifier 240W. |
| 643 | Supply and Installation of Conference Controller. |
| 644 | Supply and Installation of Delegate Unit. |
| 645 | Supply and Installation of Wall Speaker 30 W. |
| 646 | Supply and Installation of 2 core 1.5 sq.mm Shielded copper speaker cable. |
| 647 | Supply and Installation of 86,4K,Andriod-13, INTREACTIVE TOUCH Professional Display with USB-C,HDMI-In & Out. |
| 648 | GST @ 18% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail