| Sl. No. | Item Description |
| 1 | Renovation Work |
| 2 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 3 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. Extra for making of structural steel work required to be re-erected. |
| 4 | Random rubble dry stone Kharanja under floor. |
| 5 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil |
| 6 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 7 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 8 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 9 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 10 | Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at sitecomplete as per direction of Engineer In charge |
| 11 | Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm |
| 12 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 13 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. |
| 14 | Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete:M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 15 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 16 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: Old work (One or more coats). |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old Work |
| 19 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 20 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: Asbestos Sheet. |
| 21 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 22 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 23 | Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc.complete in all respects. |
| 24 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make on surface ISI marked(IS-19427-P-II) PVCcasing capping and its accessories, round tiles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point 6 A switch, 3.0 mm. thick ISI marked phenolic laminated sheet, zinc plated/brass screw, cup washers, making connections, testing etc. as required. Short point (upto 3mtr.) Group-2 |
| 25 | (a) Short Point (upto 3 mtr.) |
| 26 | (b) Medium Point (upto 6 mtr.) |
| 27 | (c) Long Point (upto 10 mtr.) |
| 28 | Wiring for 3 pin 5 amp light plug point with 1.5 sqmm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 Sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit and it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in swith board & falce ceiling point, 6 A swith, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc. as required on board. Grade-II. |
| 29 | S&Ffollowingsizes(dia.)ofISImarkedmediumdutyPVCconduitalongwithaccessoriesinsurface/recessedusingsaddles,clamps,fastenerasrequiredincludingcuttingthewall,coveringconduitand making good the same as required. 25mm |
| 30 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group p-2 |
| 31 | 1 x 1.5 sq.mm |
| 32 | 2 x 2.5 sq.mm |
| 33 | 2 x 4.0 sq.mm for powder circuit |
| 34 | 2 x 6.0 sq.mm for powder circuit |
| 35 | P&F two pin energy efficient compact flourscent lamp in existing holder/fixture as required. 36 watt 4 pin Group-II |
| 36 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D tripping characterstic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing boards/sheets including making connections with lugs, testing etc. as required 6 A to 32 A rating (Havells, HPL, SSK, Anchor, Khaitan).Grade-II. |
| 37 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V-1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 38 | P & F Fluorscent tube rod in existing fixtures as required, Flourscent powder coated (minimum 3 star rating) 36/40 Watts |
| 39 | P & F ISI marked 6 amp bakelitebatten/angle holder including makingconnection testing etc. as required. |
| 40 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaireon existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KVexternal. driver should be Phase to phase protection of 440 V for 4Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/attached with this BSR . work , refer Annexure \\"A\\" LED Street Light fixture 60 Watt |
| 41 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 42 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 43 | Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 44 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead :With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 45 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 46 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 47 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. Add extra for 0.60mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel sheet in place of 0.50mm thick |
| 48 | Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame & diagonals braces of 40 x 40 x 6mm. angle iron3mm M.S. gusset plates at the junction and corners, 25mm dia pulley 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. |
| 49 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods andhire charge of welding meachine and TP etc complete |
| 50 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-(i) Choping losse and cracked concrete to required depth,cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.(iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wetsurface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work includingscaffolding etc. complete in all respect.Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-(i) Choping losse and cracked concrete to required depth,cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.(iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wetsurface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work includingscaffolding etc. complete in all respect. |
| 51 | Providing & applying Three coat of Acrylic Water Proof membrane having sunlight and UV resistant properties over waterproofing slurry coat , initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 parts of clean water, over which applying 2 coats at 2 Hrs .intervals each with diluting 1 part of chemical with 20% of clean water for total thickness of 400 to 450 microns (covering area 0.9Sq.M/Kg of chemical including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractor's labour, tools, machinery etc, complete as directed by Engineer in Charge. |
| 52 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 53 | Renovation Work 8 & 9 Godown |
| 54 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 55 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. Extra for making of structural steel work required to be re-erected. |
| 56 | Random rubble dry stone Kharanja under floor. |
| 57 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil |
| 58 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 59 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 60 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 61 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 62 | Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at sitecomplete as per direction of Engineer In charge |
| 63 | Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm |
| 64 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 65 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. |
| 66 | Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete:M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 67 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 68 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: Old work (One or more coats). |
| 69 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 70 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old Work |
| 71 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 72 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: Asbestos Sheet. |
| 73 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 74 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 75 | Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc.complete in all respects. |
| 76 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make on surface ISI marked(IS-19427-P-II) PVCcasing capping and its accessories, round tiles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point 6 A switch, 3.0 mm. thick ISI marked phenolic laminated sheet, zinc plated/brass screw, cup washers, making connections, testing etc. as required. Short point (upto 3mtr.) Group-2 |
| 77 | (a) Short Point (upto 3 mtr.) |
| 78 | (b) Medium Point (upto 6 mtr.) |
| 79 | (c) Long Point (upto 10 mtr.) |
| 80 | Wiring for 3 pin 5 amp light plug point with 1.5 sqmm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 Sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit and it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in swith board & falce ceiling point, 6 A swith, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc. as required on board. Grade-II. |
| 81 | S&Ffollowingsizes(dia.)ofISImarkedmediumdutyPVCconduitalongwithaccessoriesinsurface/recessedusingsaddles,clamps,fastenerasrequiredincludingcuttingthewall,coveringconduitand making good the same as required. 25mm |
| 82 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group p-2 |
| 83 | 1 x 1.5 sq.mm |
| 84 | 2 x 2.5 sq.mm |
| 85 | 2 x 4.0 sq.mm for powder circuit |
| 86 | 2 x 6.0 sq.mm for powder circuit |
| 87 | P&F two pin energy efficient compact flourscent lamp in existing holder/fixture as required. 36 watt 4 pin Group-II |
| 88 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D tripping characterstic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing boards/sheets including making connections with lugs, testing etc. as required 6 A to 32 A rating (Havells, HPL, SSK, Anchor, Khaitan).Grade-II. |
| 89 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V-1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 90 | P & F Fluorscent tube rod in existing fixtures as required, Flourscent powder coated (minimum 3 star rating) 36/40 Watts |
| 91 | P & F ISI marked 6 amp bakelitebatten/angle holder including makingconnection testing etc. as required. |
| 92 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaireon existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KVexternal. driver should be Phase to phase protection of 440 V for 4Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/attached with this BSR . work , refer Annexure \\"A\\" LED Street Light fixture 60 Watt |
| 93 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 94 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 95 | Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 96 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead :With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 97 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 98 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 99 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. Add extra for 0.60mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel sheet in place of 0.50mm thick |
| 100 | Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame & diagonals braces of 40 x 40 x 6mm. angle iron3mm M.S. gusset plates at the junction and corners, 25mm dia pulley 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. |
| 101 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods andhire charge of welding meachine and TP etc complete |
| 102 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 103 | Renovation Work 1, 2 & 3 Godown |
| 104 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 105 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. Extra for making of structural steel work required to be re-erected. |
| 106 | Random rubble dry stone Kharanja under floor. |
| 107 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil |
| 108 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). |
| 109 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 110 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 111 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 112 | Refebrication work with existing steel work including cutting, welding & refebrication as per requirement with fixing at sitecomplete as per direction of Engineer In charge |
| 113 | Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm |
| 114 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 115 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. |
| 116 | Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete:M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 117 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 118 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: Old work (One or more coats). |
| 119 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 120 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old Work |
| 121 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 122 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: Asbestos Sheet. |
| 123 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) |
| 124 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 125 | Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc.complete in all respects. |
| 126 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS : 694) of approved make on surface ISI marked(IS-19427-P-II) PVCcasing capping and its accessories, round tiles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point 6 A switch, 3.0 mm. thick ISI marked phenolic laminated sheet, zinc plated/brass screw, cup washers, making connections, testing etc. as required. Short point (upto 3mtr.) Group-2 |
| 127 | (a) Short Point (upto 3 mtr.) |
| 128 | (b) Medium Point (upto 6 mtr.) |
| 129 | (c) Long Point (upto 10 mtr.) |
| 130 | Wiring for 3 pin 5 amp light plug point with 1.5 sqmm. nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 Sq. mm. nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit and it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in swith board & falce ceiling point, 6 A swith, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated/ brass screws, cup washers, making connections, testing etc. as required on board. Grade-II. |
| 131 | S&Ffollowingsizes(dia.)ofISImarkedmediumdutyPVCconduitalongwithaccessoriesinsurface/recessedusingsaddles,clamps,fastenerasrequiredincludingcuttingthewall,coveringconduitand making good the same as required. 25mm |
| 132 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group p-2 |
| 133 | 1 x 1.5 sq.mm |
| 134 | 2 x 2.5 sq.mm |
| 135 | 2 x 4.0 sq.mm for powder circuit |
| 136 | 2 x 6.0 sq.mm for powder circuit |
| 137 | P&F two pin energy efficient compact flourscent lamp in existing holder/fixture as required. 36 watt 4 pin Group-II |
| 138 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D tripping characterstic) ISI marked IS 8828 (1996)/ conforming to IEC 60898 in existing boards/sheets including making connections with lugs, testing etc. as required 6 A to 32 A rating (Havells, HPL, SSK, Anchor, Khaitan).Grade-II. |
| 139 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V-1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 140 | P & F Fluorscent tube rod in existing fixtures as required, Flourscent powder coated (minimum 3 star rating) 36/40 Watts |
| 141 | P & F ISI marked 6 amp bakelitebatten/angle holder including makingconnection testing etc. as required. |
| 142 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaireon existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KVexternal. driver should be Phase to phase protection of 440 V for 4Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/attached with this BSR . work , refer Annexure \\"A\\" LED Street Light fixture 60 Watt |
| 143 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 144 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 145 | Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 146 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead :With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 147 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 148 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 149 | Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. Add extra for 0.60mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel sheet in place of 0.50mm thick |
| 150 | Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame & diagonals braces of 40 x 40 x 6mm. angle iron3mm M.S. gusset plates at the junction and corners, 25mm dia pulley 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. |
| 151 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods andhire charge of welding meachine and TP etc complete |
| 152 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 153 | Less :- Credit for dismantled item in 22 Godown (Old Ac Sheet Roofing Godown No. 10 & 11 @ 30/Sqm * 1843.00 = 55290.00, Old Steel @ 25/Kg @ *200 = 5000.00) = 60290.00 Godown No. 8 & 9 @ 30/Sqm * 1843.00 = 55290.00, Old Steel @ 25/Kg @ *200 = 5000.00) = 60290.00 Godown No. 1, 2 & 3 @ 30/Sqm * 1843.00 = 55290.00, Old Steel @ 25/Kg @ *200 = 5000.00) = 60290.00 |
| 154 | Note :- (1) The quantity of dismantled material are tentative which my vary depending upon actual weightment/counting/measurement respectively. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail