| 1 | Material and labour for installation of unipole PC as specified below:- (i) Size of Flex Board-(20 ft x 10ft) (LXW) (Star Flex Print with ACP Boarders) 1.5\\" x 1.5\\" pipe, 2\\" x 1\\" Angle, 4\\" x 2\\" Channel). (ii) Length of Iron Unipole - (15ft from the ground) (iii) ACP Board with Backing. (iv) Backlit with LED Module. (v) Foundation/Base for the structure (depth 5ft) (vi) Construction material, Electrical wiring and paint (vii) Material and Transport (viii) Warranty-2 Year |
| 2 | Excavating in post holes or similar holes each n.exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth arround in layers n exc 25cm watering and ramming surplus soil to a distance e exc 50m and making good as in soft/loose soil complete all as specified and directed. |
| 3 | Only Refixing (Except Tile) machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed. |
| 4 | Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete, sub-base & sub-floor, etc. complete all as specified and as directed |
| 5 | Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 6 | M&L for 60 mm thick rubber moulded glossy finish precast concrete interlocking pavers/tiles with grey cement and no pigment, confirming to IS 15658-2006 M-35 Grade, of any size & shape as directed in floors over & including 25mm thick sand screed bedding/cushioning etc complete all as specified and directed. |
| 7 | M& L for preparation of new steel surfaces exceeding 10cm in width or girth and applying 02 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 8 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 9 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 10 | S & F Fe-290 (Gde E 165) Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 11 | S & F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel' complete all as specified and directed. |
| 12 | M & L for cement concrete in foundation filling of post type C-1,1:3:6(using 20 mm graded stone aggregate in C M 1:6 complete all as specified & directed. |
| 13 | Dismantling structural or mild steel work including doors, gates, stairs, grills windows and other miscellaneous items, complete all as specified and as directed. |
| 14 | S & F 1.00mm thick plain galvanised, Mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and grith as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 15 | Supply and fixing mild steel framed work such as grills, guard bars, gate, gratings, door frame etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe290,Gde-E-165 complete all as specified and as directed |
| 16 | S & F of ceiling Fan 5 star rated ISI marked 1200mm sweep, 230 volt, 50Hz AC supply with brushless direct motor (BLDC) 6.00 BEE alongwith down rod, canopy complete and connecting up including provision of three core flexible PVC cable with stranded copper conductor of size 0.75 Sq.mm from ceiling rose to connector and extra 3 feet down rod, if required at site for fixing of ceiling fan complete and taking down old unserviceable fans and to be deposited at E&M store yard complete all as specified and as directed |
| 17 | Supply, installation, testing and commissioning of Electric Water Heater (Geyser) capacity of 25 Ltrs, heating element upto 2 KW, 230 volt, BEE 5 star rated storage type steel body with stainless steel with a glass linked (Vitreous emamel) inner tank comprising with heating element, safety value, thermostate and automatic thermal cutoff, NRV, require all connection Pipe ISI maeked of 15mm dia 600mm long suitable for hot water supply with SS nuts and PCV/rubber sealing washers including mounting on wall with help of suitable nuts & bolts and hole fasteners by help of drilling and grouting complete and taking down old unserviceable Geyseres and to be deposited at E&M store yard complete all as specified and as directed. |
| 18 | S & F of Heavy duty steel body Exhaust Fan of 300mm sweep, with blade 240 volt, energy efficient complete with louvers and shutter and mounted on wall with suitable opening arrangement in wall and connection up including 3 crore PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan copmplete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distrubed wall in cement mortar white washing to match with existing colour complete and taking daown old unserviceable Ex/Fan and to be deposited at E&M store yard complete all as specified and as directed Please Enable Macros to View BoQ information |