| 1 | Earth work in excavation by manual /mechnical means in foundation trenches or drains (not exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead as directed from edge of cutting All kinds of soil. |
| 2 | Supplying and laying soling dully hand packed tightly including ramming , watering and with all carriages up to the site of work . |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to all level ( 1:4:8 (1 Cement: 4 corse sand: 8 grade stone aggregate 40mm nominal size) crushed |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to all levels ( 1:2:4 (1Cement- 2 fine sand: 4 grade stone aggregate 20mm nominal size). Crushed including all carriages up to the site of work . |
| 5 | Centering and shuttering including strutting propping etc. and removal of form work in foundation footings basis of colums ,suspended floors etc. |
| 6 | Brick work with common clay (non Modular ) bricks in class designation 7.5 in foundation and plinth including extra for brick work with common brunt clay bricks in superstructure all work upto plinth level including curring and cement motor (1:4) (1 cement 4 Course sand ) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo- Mechanically Treated bars of grade Fe-500D or more |
| 9 | 12 mm thick cement plaster on rough side of single or half brick / concrete wall of mix 1:6 mix ( 1cement:6 coarse sand incl. cost of scaffolding complete and carraige of material . |
| 10 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. kajari,somany,nitco,orientbell etc or equivalent approved by EIC |
| 11 | Providing and fixing 1st quality ceramic anti skid floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. kajari,somany,nitco,orientbell etc or equivalent approved by EIC |
| 12 | Providing and fixing of the following hardware fittings,brass make or eequavalent as per direction by EIC a)TOWER BOLT 100 MM |
| 13 | TOWER BOLT 150 MM |
| 14 | TOWER BOLT 200 MM |
| 15 | ALDROP |
| 16 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 17 | Providing and placing on terrace (at all floor levels) polythene water storage tank ISI : 12701 mashed indicating the BIS license no .with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but including all fittings and the base support for tank syntax)or equilant having valid ISI license complete. ( Five Layer ) |
| 18 | Providing and fixing water closet squatting pan ( Indian type W.C. pan) with 100 mm sand cast Iron P or Strap, 10 litre low level P.V. C. flushing cistern including flush pipe (of approved make) \\"manually contro(led device (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 19 | Providing and fixing wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap |
| 20 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 21 | Providing and fixing 03 Layer P.P.R. pipes SDR 7.4UV Staplised and antimicrobial fusion welded having thermal stability for hot and cold water complete with PPR. fittings and clamps , including cutting and making good the walls etc of 25mm dia,,32mm medium. with all necessary PPR fittings 15mm to 25mm complete job. 32 MM Dia |
| 22 | Providing and fixing 03 Layer P.P.R. pipes SDR 7.4UV Staplised and antimicrobial fusion welded having thermal stability for hot and cold water complete with PPR. fittings and clamps , including cutting and making good the walls etc of 25mm dia,,32mm medium. with all necessary PPR fittings 15mm to 25mm complete job. 20MM Dia |
| 23 | Providing and fixing of pvc prince pipes ( prince /finolex /jindal make ) pipes ( type B ) in proper graident in excavated trenches including jointing and refilling the excavated material complete including cost of excavation. Including bends ,L,Floor trapes etc all pvc necessary fittings complete job 100mm |
| 24 | Providing and fixing of pvc prince pipes ( prince /finolex /jindal make ) pipes ( type B ) in proper graident in excavated trenches including jointing and refilling the excavated material complete including cost of excavation. Including bends ,L,Floor trapes etc all pvc necessary fittings complete job 75 mm |
| 25 | Providing and fixing of brass angle value of approved quality( Hindware ,Jackwar,Cera,Jhonson etc or equivalent as per direction by EIC (LMR) |
| 26 | Providing and fixing of brass bib cock of approved quality( Hindware ,Jackwar,Cera,Jhonson etc or equivalent as per direction by EIC (LMR) |
| 27 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer of approved make quality( Hindware ,Jackwar,Cera, Jhonson etc or equivalent as per direction by EIC (LMR) |
| 28 | Providing and fixing of C.P.grating 100mm size.ISI |
| 29 | Random Rubble stone masonary laid dry stones without Bond Stone including carriage of stones (Complete Job) |
| 30 | Carriage ofSand/ Bajari from nearest source to site of work avg. lead 60km |
| 31 | carriage of bricks for an average lead of 60 kms |
| 32 | Electrical Part: Wirlng for lighting polnts/fan points/ exhaust fan polnts/call bell polnts with 1.5 sq mm FRLS PVC Insulated flexible stranded copper conductor wires In recessed or surface medium class PVC condult, with 240V GA modular switch ,modular plate and carthing the polnt with 1,5 sq. mm FRLS PVC Insulated copper conductor single core cable, etc. as required. (Havells,polycab, Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of condult. |
| 33 | Wiring for light/power plug points {15/1GA heating polnts) with 2x4 sq mm FRLS PVC Insulated flexible stranded copper conductor wlres In recessed or surface medlum class PVC condult along with 1x4 sg. mm FRLS PVC Insulatedcopper conductor single core cable for loop earthing, etc. as required.(Maximum two polnts shall be connected on one clrcult).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) excl. cost of conduit |
| 34 | Supplylng and fixing of sultable size GI box With modular plate and modular cover In front on surface or In recess, Including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connectlons, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schnelder or equivalent) |
| 35 | Supplying and fixing of sultable size Gl box with ‘modular plate and modular cover in front on surface or In recess, Including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schnelder or equivalent) |
| 36 | Point wirlng for SA -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC Insulated 660/1100volt grade flexible stranded copper “conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make In recessedor surface condulting system and earthing the point with 1 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on3 one circult). (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit |
| 37 | Supply, Installation, testing and commissloning of 12 Watt LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average llfe 50000 hours, Operating temperature -10'Cto +45°C. The job includes replacement warranty of fixture If damaged/ burnt outwhat so ever reason for a period of two years reckoned from the date ofsuccessful commissioning/ handing over of site to the Intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). |
| 38 | Supply, Installation, testing and commissioning of 400 mm sweep wall fans , Incl. making of necessary connections. (Havells/ Philips/ Crompton/ Anchor). |
| 39 | Supply, installation, testing and commissloning of 200-250 mm sweep shutter type exhaust fans, incl. cost of celling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Phillps/ Crompton/Anchor). |
| 40 | Supply and fixing of modular blanking plates on modular switch plates, excluding cost of switch plates, |
| 41 | ‘Wiring for sub mains along with earth wire in FRLS PVC Insulated 660/1100volt —grade flexible stranded copper conductor wires In recessed or surfacecondulting system, excluding cost of conduits(Havells/ Polycab/ Finolex/Anchor/KEI/RR). 2x2.5 sq.mm + 1x 2.5 sq. mm_lighting circult |
| 42 | 2x6.0 sq.mm +1x 659, mm _Lighting sub maln |
| 43 | 2x105q.mm +1x 6 sq. mm_Heating sub maln |
| 44 | Supply and fixing of 25 mm dla./25 mm wide medlum class PVC condult along with accessorles, Including cutting the wall and making good the same as reqd. |
| 45 | Supply and fixing of 16 way , Double door surface/ recess mounting , Horlzontal type, 240 V, SP&N MCB distribution board of sheet steel, dustprotected, duly powder painted, Inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer, (Havells/Legrand/SSK) |
| 46 | Supply, Installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA MCB sultable for Inductive load In the MCB distribution board complete with necessary connectlons. (Havells/ Legrand/ L&T/ABB/ Schnelder). |
| 47 | Supply,Installation,testing and commissioning of 32A DP rating 240/415v, 10 kA MCB suitable for inductive load in the MCB distribution board complete with necessary connections, (Havells/ Legrand/ L&T/ABB/ Schnelder). |
| 48 | Supply,Installation,testing suitable and commissioning of 63A DP MCB rating for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider) |
| 49 | Supply,installation,testing and commissioning of 100A DP MCB rating 240/415, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ LE&T/ABB/ Schneider). |
| 50 | Supply,installation, testing and commissioning of 200A SP&N (2 strip) aluminum bus bar chamber |
| 51 | Supply, laying, and connecting and commissloning of 25 sq. mm 2 core XLPE steel armored 1.1 KV grade Aluminum LT cable from LT panel to LT pole, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). |
| 52 | Supplying and fixing of modular 6A socket out let/ indicators on existing modular plate and switch box, incl. connections, etc. as required. (Havells/Anchor/Gold medal/Legrand/SSK) 1.3 pin 5/6A socket, |
| 53 | Indicator. Please Enable Macros to View BoQ information |