| Sl. No. | Item Description |
| 1 | Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based Plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed. |
| 5 | M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes complete all as specified and directed. |
| 6 | M & L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. including 15 mm thick screed bed made in 1:6 cemenr mortar set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 7 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m |
| 8 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with Ultra Tech READIPLAST by adding 17-19% of potable water by weight of material. for thickness above 15mm, it is recommended to be applied in multiple layers. Ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 days- 10-12 Mpa/Bulk density-1500-1600 kg/cum. Note : The rate quoted by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 10 mtr height, all as specified and directed. |
| 9 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting , and internal plastering complete all as specified and as directed. |
| 10 | M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished smooth and even in ceiling without using extra cement. |
| 11 | M & L for glazed ceramic coloured / printed tiles 300mm x 600mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed. |
| 12 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 13 | Hacking out old broken glass ( any thickness ) size or description from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 14 | S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 15 | S & F 3 mm thick Figured glass pin headed type, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 16 | S & F in Repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples. |
| 17 | Dismantling of boarding , any description fixed in any position with screws complete all as specified and directed. |
| 18 | M&L 18/19 mm thick prelaminated particle board, interior graded, prelaminated one side with decorative choice laminated and other side balancing white lamination fixed with screws to timber frame work as in Shutter of Cupboards/Kitchen cupboard with teak beading of all sides fixed in repair complete all as specified and directed. |
| 19 | Supply and fix Continuous (piano) hinges width 30 mm mild steel , bright finish or eletrogalvanised complete all as specified |
| 20 | S & F 75 mm long Aluminium handles, cast type, anodised complete all as specified and directed. |
| 21 | S & F 300 mm long (Length of bolt) mild steel sliding door bolts plate type stove enamelled blackwith bright bolt not less than 12mm dia with and including a minimum 6 bolts and nuts four on bolt plate and two on staple plate complete all specified and directed. |
| 22 | S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm Complete all as spcified and directed |
| 23 | S&F in Repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 24 | Taking down wooden chowkhat or frame area not exc 1.5 sqm each with shutter (without taking off shutter from frame) as directed. |
| 25 | Taking down wooden chowkhat or frame area exc 1.5 sqm and not exc 4 Sqm each with shutter (without taking off shutter from frame) as directed. |
| 26 | S&F Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 27 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 28 | S & F 1st class Hard Wood plain solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, And making good with existing surface as complete as specified and directed. |
| 29 | S & F 35 mm thick 1st class hard wood Glazed and skeleton door shutters, open rebated and prepared to receive gauze without sash bars, edges of framing plain fitted with cut and mitred beads for securing wire mesh or glass, size of members of shutter as specified in SSR Pt-I Sec-8 clause 8.24(a) fitted to chowkats, complete as specified and directed. |
| 30 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded |
| 31 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded |
| 32 | Taking down shutters ( per leaf ) of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified and directed. |
| 33 | S & F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 34 | S & F 30 mm thick (batten thickness ) I st class hard wood, plain framed, panelled shutter (Any numbers of pannel) of with pannel of timber flat on both sides (feather edges) or 12 mm thick veneered particle board medium density wood particle board with commercial face veneers fitted to chowkhats complete as specified and directed. |
| 35 | S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. |
| 36 | M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces. |
| 37 | M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint). |
| 38 | S & F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed and fixed tcomplete all as specified and directed. . |
| 39 | S & F butt hinges, medium weight, stainless steel and fixed, size of hinges 100mm complete all as specified and directed. |
| 40 | S & F 100mm long Aluminium handles, cast type, anodised complete all as specified and directed. |
| 41 | S&F Aluminium ( Extruded Section) body Door closer hydraulically regulated designation No. 1, universal type suitable for door shutters 700 mm in width and of wt. below 35 kg , fixed in repair complete all as specified and directed. |
| 42 | S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed. |
| 43 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:4) |
| 44 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed |
| 45 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed |
| 46 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 47 | S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 48 | Cutting chases, for water tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:4) cutting not exceeding 10cm girth in brick walls complete all as specified and directed. |
| 49 | Refixing of old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) |
| 50 | Refixing of old 20 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) |
| 51 | S & F PVC (SWR) multi floor trap 75mm with grating including jointing with solvant cement complete all as specified and directed. |
| 52 | S & F in repair Bib tap 15mm cast copper alloy, bright, crutch or butter fly handle screwed down, fancy type chromium plated for iron pipes complete all as specified and directed. |
| 53 | S & F in repair 15mm stop valve / angle valve, CP Fancy type screwed down high pressure with crutch or butter fly handle of fancy type chromium plated screwed both ends of, complete all as specified and directed. |
| 54 | S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends |
| 55 | S&F stainless steel wall mounted plate rack of size 780x760x240mm, made from the stainless steel sheet having thickness 1 mm and weight not less than 7.50 Kg, design & pattern as approved by GE, having sufficient space for placing crockeries, fixed on wall with rawl plug & screws, complete all as specified and directed |
| 56 | S&F 500 ltr capacity rotational mounded polythylene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position including dismantling unserviceable PVC/Cement water storage tank 500/1000 complete all as specified and directed. |
| 57 | Supply only 15mm Ball valves/float valve, high pressures of PTMT, with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe, Minimum wt (15mm -142gms) (Make: Prayag/Shakti) complete all as specified and directed. |
| 58 | S & F in repairs 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with fixing brackets ,stops,rollers etc. complete all as specified. |
| 59 | S& F in repair Vitreous china premium/ 1st quality wash down water closet EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 60 | S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed. |
| 61 | S&F vitreous china wash basin white flat back, size 550x400mm excluding taps , waste but including brackets as in repair, complete all as specified and directed. |
| 62 | S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 63 | S & F PVC (SWR) multi floor trap 75mm with grating including jointing with solvant cement complete all as specified and directed. |
| 64 | S&F in repair 600mmx450mm bevelled edge looking mirror and fixed to wooden plug with CP brass screws and cup washers complete all as apecified & directed |
| 65 | S&F in repair Toilet Paper Holder of brass chromium plated or stainless steel fixed to walls with chromium plated brass screws. |
| 66 | S&F in repair, Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 67 | S & F in repairs 15 mm bore pillar taps, Cast Copper alloy,fancy type with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe. complete all as specified and directed. |
| 68 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 69 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 70 | S&F in repairs Gun Metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, 20mm bore complete all as directed. |
| 71 | Dismantling laid dry or laid dry and pointed Stone slabs and tiles of any description or thickness in floors, aprons etc. |
| 72 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite |
| 73 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 74 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 75 | S&f Fe 410-W (Gde E- 250) quality A as in rolled mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 76 | Demolition of reinforced cement concrete of any description and in any position in beams shelves and similar works |
| 77 | M & L for RCC Type B1 1:2:4 (20mm graded aggregate) for Slabs supported on walls, beams and columns in Chajjascomplete all as specified and directed |
| 78 | M&L for Formwork to flat surfaces of chullah hoods, chajjas, troughs and similar items in cluding edges |
| 79 | S & F MS steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality conforming to IS 1786-1985 complete all as specified and directed |
| 80 | S & F MS steel TMT bars over 5 mm and upto 10 mm dia as in stirrups and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality conforming to IS 1786-1985 complete all as specified and directed |
| 81 | Material & labour for preparation of old decorated plastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salt and trading oil and greasy spots and applying one coat of oil bound distemper complete all as specified and directed |
| 82 | Material & Labour for complete removal of existing treatment & applying a layer of JK/ Birla putty 1 mm thick (average) on wall surfaces in patches including cornics etc for proper levelling of plaster complete all as specified and directed. |
| 83 | M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surface preparatory to distempering) complete all as specified and directed. |
| 84 | S & F for powder coated GI Everest ceiling grid system of grid size 600 X 600 mm fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the Main Tee 28x24x3mm thick, Cross Tee 28x24x3mm thick and Wall angle 24x24x3mm thick sections complete all as specified and directed:- |
| 85 | S & F 4 mm thick Everest designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 595 X 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed |
| 86 | Material & Labour for preparation of old decorated plastered or unplastered surfaces of walls including cornices etc by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salt and trading oil and greasy spots and applying one coat of cement base paint . The contractor shall make necessary arrangement of scaffolding and ensure safety of Labours complete all as specified and directed. complete all as specified and directed. |
| 87 | Material & Labour for preparation of old or previously treated steel surfaces of any description, not otherwise description- bed over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 88 | Excavation in trenches n exc 1.5m wide & n exc 1.5m in depth in hard/dense soil for foundation etc or for manholes, shafts etc n exc 10 sqm on plan and getting out complete all as specified and directed. |
| 89 | Demolition and breaking up drain pipes (SWG, AC or RCC) set in cement mortar incl cement concrete bedding hunching etc and removing from site to a distance n exc 50m as directed all as specified and directed. |
| 90 | M & L for cement conc 1:4:8 type D2 using 40mm graded crushed stone agg bed to drain pipes including packing under and hunching against the sides of pipes after they are laid and tested 150mm bore pipe complete all as specified and directed |
| 91 | M & L for 150mm bore salt glazed stoneware drain pipes grade A laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed |
| 92 | M & L Returing , filling in including spreading , levelling watering and well ramming in layers not exc 25cm as in hard/dense soil complete all as specified. |
| 93 | M & L Removing excavated material exc. 250m but n' exc 500m and depositing where directed as in soil complete all as aspecified and directed. |
| 94 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars for ashlar facings,dressed stonework, precast concrete articles and precast concret block walling etc complete all as specified and directed. |
| 95 | M&L precast cement concrete 1:3:6 type C1(using 20 mm graded stone agg) as in block masonry with solid blocks exc 10 cm in width and set in cement mortar 1:6 complete all as specified and directed. |
| 96 | M&L For 100 mm Thick Cement concrete type D-2 1:4:8 (using 40 mm graded stone aggegate ) as in sub base course complete all as specified and directed. |
| 97 | M&L for Ceramic tiles exterior grade 300 x 300 x 10mm including 15 mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match |
| 98 | M & L for PCC ( 1:3:6) type C-2, using 40mm graded stone aggregate in Cement concrete in surface channels and drains |
| 99 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 100 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 101 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FR-LSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed. (a) One light/One fan/one bell point controlled by one modular switch |
| 102 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 103 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 104 | All as per item No 2 herein before but wiring with 2.5 sqmm copper wire (FR-LSH) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 105 | Supply and fix modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 106 | Supply and fix socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 107 | Supply and fix switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 108 | Supply and fix socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 109 | S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 110 | S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 111 | Supply and fix High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 112 | Supply & Fixing of MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps . |
| 113 | Supply & Fixing of MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps. |
| 114 | Supply & Fixing of MCB DP , 240 volts,AC C curve, 10 KA 40 Amps. |
| 115 | Supply & Fixing of MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps. |
| 116 | S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps including one 15 Amp switch on existing board with wiring for switching geyser on/off complete all as specified and directed. |
| 117 | Supply & Fixing of non metallic PVC conduit 25 mm exclusive of boxes but including of all tees,bends,elbows, reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles, pipe hooks etc. concealed in wall ceiling floor etc for television/DTH/telephone/Data cable complete all as specified and directed. |
| 118 | S& F socket outlet for TV/Video/audio device modular type with inner and outer modular plate type, specially built for wall/high mounted TV and inc pressed steel/metal flush box concealed complete all as specified and directed. |
| 119 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings |
| 120 | Taking down carefully All types of DB's/ MCB DB's with MCB and making good the disturbed surfaces of walls as directed. |
| 121 | Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 122 | S&F sheet metal enclusure for DBs(double door type) Triple pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed . |
| 123 | S & F LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 124 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 125 | S& F LED Bulb of 9 watt as specified .NOTE: The contractor must submit 5 years warranty for LED fittings |
| 126 | Supply and fixing Geyser 25 Ltr Capacity with SS Tank BEE five star rating with Digital Temperature Display & heating element upto 2 KW, ISI mark, with all accessories such as safety valve, thermostate, NRV, connection piece etc, and making good as per existing surface Complete all as specified and directed. |
| 127 | S & F Exhaust fan plastic body heavy duty ISI mark, 250 mm size with louvers including all connecting accessories and cutting opening on wall and making good as per existing surface complete all as specified and directed |
| 128 | S&F Exhaust fan metallic body ISI mark, 450 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed. |
| 129 | Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 130 | S&F sub main wiring with two single core FR-LSH PVC insulated and sheathed 1100 Volts grade, 6.0 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 131 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. |
| 132 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 133 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 134 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 135 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 136 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified . |
| 137 | M & L galvanised steel water tubing 'light grade' 40 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . |
| 138 | Taking down carefully GI pipe and S & F Steel water tubing medium grade galvanised with all GI fittings (such as bend,elbows,tees, connections, short pieces, back, nuts, unions, caps & plugs etc) laid in trenches or fixed on walls or on open surfaces complete all as specified and directed of the size 20 mm(3/4\\") bore. |
| 139 | Taking down and S & F gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed of the size 20 mm (3/4\\") bore ( Nominal bore) |
| 140 | Excavation in trenches in hard/dense soil not exceeding 1.5m wideand not exc 1.5mtr depth for laying pipe line and getting outincluding trimming sides and forming bottom surface to the required level/slope etc. complete all as specified and directed |
| 141 | M&L for cutting existing steel tubing of size 40 to 50 mm for alterations or additions alongwith insertion of GI Tee of suitable size and connection material Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail