| 1 | CABLE,4CX1.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 4C X 1.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 2 | CABLE,14CX1.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 14C X 1.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 3 | CABLE,27CX1.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 27C X 1.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 4 | CABLE,4CX2.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 4C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 5 | CABLE,24CX2.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 24C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 6 | CABLE,4CX95MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 4C X 95 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 7 | CABLE,5CX1.5MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 5C X 1.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 8 | CABLE,12CX1.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 12C X 1.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 9 | CABLE,14CX2.5MM2,CU,UNARMD,EPR-CSP,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 14C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION EPR (OIL RESISTANT & FLAME RETARDANT TYPE IE4 AS PER IS 6380/84.), MELINEX TAPE TO BE APPLIED OVER THE CONDUCTOR, SHEATH CSP (HEAT & OIL RESISTANT AND FLAME RETARDANT TYPE SE 4 AS PER IS 6380/84). OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 10 | CABLE,1CX120MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 1C X 120 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 11 | CABLE,10CX1.5MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 10C X 1.5 SQ.MM., CABLETYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PERIS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.),SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASSBRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLESHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 12 | CABLE,1CX150MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 1C X 150 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 13 | CABLE,4CX2.5MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 4C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 14 | CABLE,18CX2.5MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 18C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 15 | CABLE,3CX2.5MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 3C X 2.5 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |
| 16 | CABLE,4CX16MM2,CU,UNARMD,SI.RBR.,1.1KV | UNARMOURED CABLE, RATED VOLTAGE 1.1KV, SIZE 4C X 16 SQ.MM., CABLE TYPE TRAILING DUTY, CONDUCTOR MATERIAL ATC FLEXIBLE (CLASS-5 AS PER IS 8130/84), INSULATION SILICON RUBBER (TYPE IE 5 AS PER IS 6380/84.), SHEATH SILICON RUBBER (TYPE SE 5 AS PER IS 6380/84). FIBRE GLASS BRAIDED AND IMPREGNATED WITH SILICON VARNISHED, CLASS-H , OVERALL CABLE SHALL BE CONFORMING TO IS 9968 (PART-1)-1988 (WITH LATEST AMENDMENT). |