Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and laying (IPS Flooring) cement concrete flooring 1:2:4, using crushed sand 50 mm thick finished smooth to the required level, finishing with a floating coat of neat cement including cement slurry, providing and fixing 25 X 3 mm aluminium strip, curing, cleaning the surface neatly at the time of handing over the area complete as per specifications and drawings as directed by the Engineer in charge |
| 2 | 50 mm thick cement concrete flooring with concrete hardener topping, under layer 38 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 3 | Providing and fixing Glazed VITRIFIED floor/wall/skirting tiles of approved make in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge Using Tiles of size 600 X 600 mm |
| 4 | Providing and fixing 15 mm thick flooring with acid and alkali resistant tiles of approved make and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineer-in-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 200 X 200 X 15 mm of approved colour including providing required slopes and levels ( this work to be carried out through approved specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 5 | Providing and fixing 10 mm thick skirting / Dadooing / wall with acid and alkali resistant tiles of approved make and colour as per IS 4457 using acid and / or alkali resistant mortar bedding and joints filled with acid and / or alkali resisting Epoxy for 5 to 8 mm depth over a bed of Bitumastic compound 8 to 10 mm layer and bitumastic primer complete as per the direction of the Engineer-in-charge In flooring over a bed of minimum 10 mm thick acid proof mortar with acid and / or alkali resistant tiles of size 300 X 300 X 10 mm of approved colour including providing required slopes and levels (this work to be carried out through approved specialized agency) complete as per specifications and as directed by the Engineer-in-charge |
| 6 | Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 of approved make in all colours and shades as approved by Engineer-in-charge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge |
| 7 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of approved make of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. |
| 8 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting, window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge |
| 9 | Extra for nosing in steps of treads Using Kotah stone |
| 10 | Providing and fixing Minimum 16 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Jet Black colour for kitchen platforms, vanity counters, wash basin counters, door frames, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete at all levels |
| 11 | 30 mm thick Fiberglass Reinforced Plastic (F. R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam {PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge |
| 12 | Providing and fixing white vitreous china European type Water Closet with'P'or'S'Trap with solid seat and lid of approved make, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend, fixing EWC with C.P brass screws, 15 mm PVC heavy quality inlet connection of 450 mm long, including testing, commissioning & cleaning etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge E.W.C. pan in White colour with ISI marked white solid plastic seat and lid |
| 13 | Providing and fixing Indian water closet (Orissa pan) of approved make with 100 mm China ware P or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe & bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15 mm Inletconnection with all fittings and fixtures complete including all connection, embedding in position commissioning, cleaning etc. all as per drawings and specifications and as directed by the Engineer-in-charge White Vitreous china Orissa pattern W.C. pan of size 580x440 mm |
| 14 | Providing and fixing vitreous China wash basin of approved make and colour with C.I. brackets,15 m C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings andbrackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge White vitreous China wash basin size 630 x450 mm and equivalent sizes with single 15 mm C.P. brass pillar tap White vitreous China counter top / counter below wash basin size 560 x 410 mm / 560 x 450 mm with single 15 mm C.P. brass pillar tap (OVAL / ROUND Models) |
| 15 | Providing and fixing C.P brass Angle cock of heavy quality of specified / approved make, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge 15 mm n.b CP brass Angle cock of approved make |
| 16 | Providing and fixing Heavy quality flexible PVC waste pipe of following dia. (semi rigid or flexible) of approved make for sink or wash basin including PVC waste fittings etc. complete all as per specifications and as directed by the Engineer-in-charge 32 mm dia flexible PVC (semi-rigid) waste pipe |
| 17 | Providing and fixing white vitreous china flat back half stall urinal size 580x380x350 mm / 610 mm of approved make Aquaseal model with Push cock of approved make, with CP brass flush pipe unions, heavy quality C.P. brass spreaders, C.P waste coupling with dome grating, clamps complete all as per specifications drawings and as directed by the Engineer-in-charge. Single half stall urinal with C.P brass Flush valve.Note : For fixing flush valve 32 mm G.I water line provision to be made which will be paid under relevant Item . |
| 18 | Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C. P brass grating , complete all as specifications and drawings and as directed by the Engineer-in-charge |
| 19 | Providing and fixing heavy quality health faucet with 1.50 metres long flexible hose (hand shower) of approved make with wall brackets and type as per specifications and as directed by the Engineer-in-charge |
| 20 | Providing and fixing C.P brass bib cock of heavy quality of specified / approved make as per specifications and as directed by the Engineer-in-charge 15 mm dia bib cock of approved type and make |
| 21 | Providing and fixing C.P brass bib cock of heavy quality of specified / approved make as per specifications and as directed by the Engineer-in-charge 15 mm Dia LONG BODY bib cock of approved type and make |
| 22 | Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combinat ion of Heavy Quality of approved make as per specifications and as directe d by the Engineer-in-charge |
| 23 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 24 | Providing and fixing 6 mm thick mirrors of size 600 x 450 mm of approved make with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls withC.P.brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-charge |
| 25 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 15 mm dia G.I pipe |
| 26 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 20 mm dia G.I pipe |
| 27 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 25 mm dia G.I pipe |
| 28 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 32 mm dia G.I pipe |
| 29 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 40 mm dia G.I pipe |
| 30 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 50 mm dia G.I pipe |
| 31 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydraulic pressure witha minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' - Class heavy quality pipes of approved make 80 mm dia G.I pipe |
| 32 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.3989 of approved make including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site 75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint |
| 33 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.3989 of approved make including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site 100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / join |
| 34 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by theEngineer-in-charge 20 mm n.b |
| 35 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by theEngineer-in-charge 32 mm n.b |
| 36 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by theEngineer-in-charge 40 mm n.b |
| 37 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by theEngineer-in-charge 50 mm n.b |
| 38 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 39 | Providing and Laying cement concrete 1:2:4 in super structure (1 cement, 2 crushed sand, 4 brick aggregates 20 mm to 40 mm) for filling sunken floors of toilet bath & kitchen admixed with proprietary water proofing compound as per manufacturer's specifications and approved by Engineer-in-charge including scaffolding, consolidation, finishing curing etc |
| 40 | Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge |
| 41 | Providing and constructioning Inspection chambers of Internal size clear dimension of 900 x 600 mm in 230 thick brick masonry with cement mortar 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed surfaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450 mm, embedding the frame and cover with CC 1:2:4 concrete, and fixing cast iron steps if necessary at 300mm intervals complete . Depth of chamber not exceeding 900 mm. |
| 42 | Designing, supplying and installing proprietary horizontal floor to floor expansion / separation / seismic joint cover assembly system of approved manufacturer WIth Stainless Steel Cover Plate : shall be made out of not less than 5 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished. for upto 300 mm wide joints |
| 43 | Designing, supplying and installing vertical wall to wall expansion / separation / seismic joint cover assembly system of approved manufacturer With Stainless Steel Cover Plate : shall be made out of 1.6 mm thick stainless steel plate conforming to SS 304 Grade. The plate shall be secured to base members by approved self centering arrangement. The exposed surface shall be mill finished. for upto 300 mm wide joints |
| 44 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 300 mm wide |
| 45 | Supply and erection of GI enclosure fabricated out of 1.6mm thick pre galvanised GI sheet steel with required cutting, welding, bending, stiffners as per drawings and embed in concrete or brick wall, cutting brick wall to suit size, etc as required under the instruction of Engineer-In-Charge. |
| 46 | Supply of enclosure |
| 47 | Installation of enclosure |
| 48 | Supply and embedment of heavy duty hot dipped GI conduit pipe as per IS 9537 along with all accessories such as inspection bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Surfacr mounted Junction box of suitable size as required suit at site shall be provided. |
| 49 | Supply of 25mm GI conduit |
| 50 | Installation of 25mm GI conduit |
| 51 | Supply and embedment of 16 SWG black enameled heavy duty rigid mild steel (MS) ERW conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut etc. including making threads, removing burrs, making chasis in wall, connection of accessories, drawing of fish wire, laying in RCC slab, beam, wall, cutting & laying in brick wall etc. as required under the instruction of engineer- in charge. Deep junction box of min. 75mm deep shall be provided. |
| 52 | 25mm MS conduit |
| 53 | 40 mm MS conduit |
| 54 | Supply of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 55 | Supply of flexible GI conduit pipe of size 26 MM |
| 56 | Installation of following size flexible GI conduit pipe including cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structure, etc. as required under the instruction of Engineer-in-charge and as per tender specification. |
| 57 | Installation of flexible GI conduit pipe of size 26 MM |
| 58 | Supply and Laying of 14 SWG Cu-ETP grade bare solid tinned copper conductor. |
| 59 | Supply of 14 SWG conductor |
| 60 | Installation of 14 SWG conductor |
| 61 | Supply and Installation of Heavy Duty Class-C GI pipe of following size to be laid in brick wall for laying cables. |
| 62 | 100NB |
| 63 | Supply of required material and making of exothermic braze joints of copper conductor with other conductor or copper earthing pad including removal of burrs and debris as per technical specification and instruction of engineer in charge. |
| 64 | Supply of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 65 | Supply of 12 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 36 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 66 | Supply of 4 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 67 | Supply of 6 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 68 | Supply of 8 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 24 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 69 | Supply of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 70 | Supply of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 71 | Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door,with R Y B Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, etc as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 72 | Installation, Testing and Commissioning of 12 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 36 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 73 | Installation, Testing and Commissioning of 4 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 74 | Installation, Testing and Commissioning of 6 way MCB DB with Incomer of 25A, Isc=10kA, Type C, TPN MCB with 2-Pole, 25A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 75 | Installation, Testing and Commissioning of 8 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 24 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 76 | Installation, Testing and Commissioning of 6 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 18 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 77 | Installation, Testing and Commissioning of 4 way MCB DB with Incomer of 16A, Isc=10kA, Type C, TPN MCB with 2-Pole, 16A, Isc=10kA, (100mA) RCBO for each phase and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 78 | Supply of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 79 | Supply of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 80 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 81 | Supply of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 82 | Supply of MCB DB with Incomer of 50A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 83 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 84 | Supply of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 85 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 86 | Supply of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 87 | Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, double door,with Phase indication and mcb position indication through glass front, IP-54, Prewired with HFFR/ FRLS copper wires, horizontal type, metallic Double Door, MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade , pre-galvanised G.I. sheet steel, suitable for surface mounting/ installation in existing enclosure complete with appropriate rating of tinned copper bus bar/ Cu wire, neutral bus bar, earth bar, din bar,brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes , neoprene gasket, check nuts etc as required as as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge. |
| 88 | Installation, Testing and Commissioning of MCB DB with Incomer of 40A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Outgoing MCB feeder as per SLD and technical specification. |
| 89 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, DP Outgoing MCB feeder as per SLD and technical specification. |
| 90 | Installation, Testing and Commissioning of MCB DB with Incomer of 63A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 91 | Installation, Testing and Commissioning of MCB DB with Incomer of 50A, Isc=10kA, Type C, DP MCB and 8 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 92 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 6 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 93 | Installation, Testing and Commissioning of MCB DB with Incomer of 25A, Isc=10kA, Type C, DP MCB and 4 nos. of 16A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 94 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 12 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 95 | Installation, Testing and Commissioning of MCB DB with Incomer of 16A, Isc=10kA, Type C, DP MCB and 8 nos. of 6A, Isc=10kA, Type C, SPN Ougoing MCB feeder as per SLD and technical specification. |
| 96 | Supply of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specification. |
| 97 | Supply of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 98 | Supply of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 99 | Supply of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 100 | Supply of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 101 | Supply of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 102 | Supply of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 103 | Installation, Testing and Commissioning of following LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, PVC conduit bushes, Cu cable lugs as per tender specifiction. |
| 104 | Installation, Testing and Commissioning of LED Bulkhead fitting (for exit lights & lift shaft) with a nominal system lumen output of 700 lumens and a minimum system efficacy of 105 lm/W. The luminaire should have a colour temperature of 6500K, CRI>80 and SDCM<5. The luminaire shall meet IP65 rating and IK08 rating with THD<20% and PF>0.9. The luminaire housing should made of Pressure Die Cast Aluminium with high quality PC diffuser. The power consumption should not exceed 6.5W (including driver). The driver shall have 2.5KV Surge protection. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. BIS certified. |
| 105 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 8400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 70W (including driver). |
| 106 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with one no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 18W (including driver). |
| 107 | Installation, Testing and Commissioning of LED 4ft Slim LED Tube light fixture with 2 no. of LED Tube having a nominal system lumen output of minimum 2340 lumens and a minimum system efficacy of 130 lm/W per tube. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<15%, PF>0.9, SDCM< 7 and RoHS compliant. The luminaire housing should made of Extruded Aluminium with extruded PC diffuser & should have anodised finish. The total power consumption should not exceed 36W (including driver). |
| 108 | Installation, Testing and Commissioning of LED integral driver Flood light with a nominal system lumen output of 4200 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire should have a CCT of 6500K and a CRI>70. The luminaire shall meet IP65 rating with THD<10% and PF>0.95. The luminaire housing should be made of pressure die cast aluminium and front toughened glass cover. The total power consumption should not exceed 35W (including driver). |
| 109 | Installation, Testing and Commissioning of 4ft Functional Batten (approx dim.140mm x 105mm x 1219mm)with 40W LED Tubelight (acid & corrossion proof) with a nominal system lumen output of 4800 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 40W(including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications. |
| 110 | Supply of the following Modular surface mounted type switch as per Technical specifications. |
| 111 | Supply of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 112 | Supply of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 113 | Supply of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 114 | Supply of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 115 | Installation of the following Modular surface mounted type switch as per Technical specifications. |
| 116 | Installation, Testing and Commissioning of switch box set consisting of 1 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 117 | Installation, Testing and Commissioning of switch box set consisting of 2 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 118 | Installation, Testing and Commissioning of switch box set consisting of 3 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 119 | Installation, Testing and Commissioning of switch box set consisting of 4 nos. of 6A, Piano type Modular Switch with heavy duty polycarbonate box and face plate and suitable mounting arrangements as per technical specification. |
| 120 | Supply of the following modular switches and plug sockets as per technical specification. |
| 121 | Supply of 2 nos. of 6/16A (compatible with both 6A and 16A with shutter), Single phase Modular Decorative Type Socket with Polycarbonate box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 122 | Supply of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 123 | Installation of the following modular switches and plug sockets as per technical specification. |
| 124 | Installation, Testing and Commissioning of 2 nos. of 6/16A (compatible with both 6A and 16A), Single phase Modular Decorative Type Socket with Polycarbonate/GI box as required, 16A Switch and heavy duty polycarbonate Face Plate, 2 nos. of 16A plug tops and suitable mounting arrangements as per technical specification |
| 125 | Installation, Testing and Commissioning of 1 nos. of 6A Single phase Modular Decorative Type Socket with polycarbonate box , Switch and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification. The whole set shall be mounted inside a IP66 enclsoure. |
| 126 | Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130/1984 as per technical specification |
| 127 | Supply of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 128 | Supply of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 129 | Installation/drawing through concealed/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100V as per the IS 17048: 2018 as per conductor class 2 of IS:8130/1984 as per technical specification. |
| 130 | Installation/drawing of Single Core HFFR wires (Copper) of size 1.5 Sq.mm |
| 131 | Installation/drawing of Single Core HFFR wires (Copper) of size 2.5 Sq.mm |
| 132 | Supply, Fabrication and Installation of Standard steel sections as per IS 2062 Grade BR for light frame, base frame, wall frames, brackets for supporting equipments etc. including all accessories, SS screw, bolts etc. Fabrication shall include drilling, entiling, welding by qualified welder, wire brush cleaning, testing DPT etc., supply of all consumables like gas, approved welding rods as per EIC and tender tech spec. After fabrication two coats of epoxy based primer and two coats of finish epoxy paints shall be applied. |
| 133 | Supply and laying of 95 sq. mm Class-2 stranded bare tinned copper conductor underground upto depth of 1 meter, including excavation, connection with earth pit at one end and connection with test link box at other end, including clamping, connection through brazing/ bolting , refilling the trench etc. as per instructions by Engineer-In-Charge. |
| 134 | Supply of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 135 | Installation of 95 sq. mm Class-2 stranded tinned copper conductor underground upto depth of 1 meter |
| 136 | Supply and surface/concealed laying including making chasing on wall of 10 sq. mm stranded tinned coper conductor, connection with earth pad at one end and DBs/ sockets/ motor at other end including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 137 | Supply of 10 sq. mm stranded tinned coper conductor |
| 138 | Installation of 10 sq. mm stranded tinned coper conductor |
| 139 | Supply and surface/concealed laying of 2 x 10 sq. mm Cu PVC insulated earthing conductor in 25 mm HDPE pipe including clamping/ cleating on surface/ floor/ ceiling/ wall/ tray, making chase, repairing the same, connection through brazing/ bolting etc. as per instructions by Engineer-In-Charge. |
| 140 | Supply |
| 141 | Installation |
| 142 | Supply and installation of 40mm HDPE pipe as per tender specifications. |
| 143 | Supply and installation of tinned Cu Lugs and Brass bolt suitable to following sizes of earthing conductors as per attached technical specification |
| 144 | Copper lug suitable for 10 Sq.mm stranded tinned copper conductor |
| 145 | Supply and installation of M10 brass nut bolt, 3/4\\" long suitable for 10mm threaded hole for making connection to earth pad. |
| 146 | Copper lug suitable for 95 Sq.mm stranded tinned copper conductor |
| 147 | Supply of Busbar Insulator of size M8 x 40mm, MOC: Epoxy as per tender specification. |
| 148 | Installation of Busbar Insulator of size M8 x 40mm for fixing of downcomer conductor from lightening arrestor as per tender specification. |
| 149 | Supply and Installation of 25 mm X 3 mm thick tinned copper strip including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 150 | Supply of 25 mm X 3 mm thick copper strip |
| 151 | Installation & Testing of 25 mm X 3 mm thick copper strip |
| 152 | Supply, Installation, Testing and Commissioning of Ceiling mounted dual type occupancy sensor with inbuilt or external power pack and auxiliary relay having min 15 mtr sensing range in 180 deg orientation and time delay ranges from 30sec to 30min and should have output relay capacity of 1000W (for LED lighting fixtures). |
| 153 | Supply of Ceiling mounted dual type occupency sensor |
| 154 | Installation, Testing and Commissioning of Ceiling mounted dual type occupency sensor |
| 155 | Supply, Installation, Testing and Commissioning of Occupancy sensor bypass switch box having 3pole rotary switch fixed on GI enclosure with cover. |
| 156 | Supply of Occupancy sensor bypass switch box |
| 157 | Installation, Testing and Commissioning of Occupancy sensor bypass switch box |
| 158 | Supply and Installation of GI Anchor Fastner of size M8x80 MM by drilling through concrete block as per site requirement for fixing plate Eps or other structures as per the tender specification. |
| 159 | Supply of GI Anchor Fastner of size M8x80 MM |
| 160 | Installation of GI Anchor Fastner of size M8x80 MM |
| 161 | Supply and Installation of 1.2 mm thick pre-galvanized GI sheet cover plates including marking, cutting (as per site requirement) and fixing on top of JB openings in wall and slab bottom/ ceiling at approx height of 5mtrs as per tender specifications. |
| 162 | Supply, Fabrication and Installation of Pre-Galvanized Powder Coated dome shaped cover of 1.6mm sheet thickness, 1220mm long for LED Tube light fittings as per specifications and instructions of Engineer-in-charge. |
| 163 | Supply of 2-way Face plate with 2 RJ11 Socket as per technical specification |
| 164 | Installation of 2-way Face plate with 2 RJ11 Socket as per technical specification |
| 165 | Supply of 4 way 4 Terminal Junction Box for PA System as per Tender specification. |
| 166 | Installation of 4 way 4 Terminal Junction Box for PA System as per Tender specification. |
| 167 | Supply of 50 Terminal Junction Box for PA System as per Tender specification. |
| 168 | Installation of 50 Terminal Junction Box for PA System as per Tender specification. |
| 169 | Supply of 20 Terminal Junction Box for PA System as per Tender specification. |
| 170 | Installation of 20 Terminal Junction Box for PA System as per Tender specification. |
| 171 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 400+400 pairs of Telephone cable as per the technical specification. |
| 172 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 400+400 pairs of Telephone cable as per the technical specification. |
| 173 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 100+100 pairs of Telephone cable as per the technical specification. |
| 174 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 100+100 pairs of Telephone cable as per the technical specification. |
| 175 | Supply of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 50+50 pairs of Telephone cable as per the technical specification. |
| 176 | Installation, Testing and Commissioning of 14 SWG Indoor type double enclosure (M.O.C: Pre-Galvanized G.I sheet steel) powder coated MDF box with krone connector suitable for 50+50 pairs of Telephone cable as per the technical specification. |
| 177 | Supply of 1 Pair x 1.5 Sq.mm twisted pair unarmoured PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 178 | Laying of 1 Pair x 1.5 Sq.mm twisted pair unarmoured PVC insulated, FRLS PVC outer sheath, stranded copper conductor, flexible cable in existing laid concealed or surface conduit. |
| 179 | Supply of 2 Pair 0.6mm copper conductor Telephone cable as per tender specifications. |
| 180 | Installation of 2 Pair 0.6mm copper conductor Telephone cable as per tender specifications. |
| 181 | Supply of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor, armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 182 | Laying of 20 Pair x 1.5 Sq.mm twisted pair PVC insulated, FRLS PVC outer sheath, stranded copper conductor,armoured cable on cable tray in trench or overhead or cleating on wall / ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 183 | Supply of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 184 | Laying of 100 Pair x 0.5 sq.mm jelly filled armoured telephone cable on cable tray in trench or overhead or cleating on wall/ceiling, including tying, clamping, putting cable tag, marking, glands, termination and other accessories etc as required. |
| 185 | Assistance to perform various cleaning activities by unskilled manpower Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail