| 1 | Supply & erection of wiring 6Amp. Plug control comprising wall socket point |
| 2 | Wiring 16/20Amp. power plug control point Surface PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES |
| 3 | Supply & erection Medium Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 4 | Supply and erection of TP&N Horizontal Double Door Distribution Board 6 way each |
| 5 | Supply and erection of MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 6 | Supply & erection of MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 7 | Supply & erection of Pvc Insulated FR Copper Conductor Cables Overall size 1.5sq.mm (Un-sheathed) |
| 8 | Supply and erection of Pvc Insulated FR Copper Conductor Cables Overall size 4sq.mm (Un-sheathed) |
| 9 | Supply and erection of Pvc Insulated FR Copper Conductor Cables Overall size 10sq.mm (Un-sheathed) |
| 10 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips RC380B LED36S-6500 G4 L60 W60 PSU OD WH OC, Crompton LCTLRNE-36-FO-CDL (2X2), Wipro CRCO10R038HP57GL1, Bajaj BZRSQL 36W GZi WH |
| 11 | Supply and Erection of Celling Fan 1200mm (48\\") with double ball bearing including flexible wire & Petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-Charge at site. Makes: Crompton High Speed Opel White, Havell's Velocity HS, Bajaj Orient |
| 12 | Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaquar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. (BFUHS/UWD/2019/10622 Dt 27/5/2019) |
| 13 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil s directed within lead of 30 metres 6.6 (A)Trench of damage electrical cable (600x2x5 Cft) = 6000 cft or 169.92 cum) |
| 14 | S/E of LT Straight Through Joint Kit Cast Resin type for 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:- Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 50 sq. mm. |
| 15 | Straight Through Joint Kit Resin Cast type for Cable Size 3½ Core 25 sq. mm - 35 sq. mm 34.34 B (xi) ( 733.00 + 30% = 952.9 +5.35% = 1003.88 ) |
| 16 | Straight Through Joint Kit Resin Cast type for Cable Size 3½/4 Core 240 sq. mm 34.34 B (xvii) (2196.00 + 30% = 2854.8 + 5.35%= 3007.53 ) |
| 17 | Supply and erection of sheet metal IronClad Changeover Switch on existing surface with G.I. bolts & nuts/rag boltsand nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existingearth as per PWD General Specifications:- Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- On Load Change Over Switch Four Pole 63amp., 415volts (With Sheet Enclosure) |
| 18 | Supply and erection of LED flood light 100 watt with high pressure die cast housing lumens 110-120,AC220-240V, 50/60Hz(IP 65 Protected) of Make Havells / Crompton/Phillips. The fitting will be mounting with the help of necessary arrangement for installation on the top parapet of the building including connection,testing & commissioning etc. complete in all respects as per satisfaction and desired by the engineer-incharge at site. |
| 19 | Supply and erection of 12\\" Heavy Duty Exhaust fan (HDEF) (300mm-900RPM) Single Phase of make Crompton Model EXHD 300-6-1 or Its equialant Make Havell's Turbo Force SP / GE / Halonix ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and louver shutter complete in all respects as appd. and desired by the Engineer in-charge at site |
| 20 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overal1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mmdia (ISI Marked) installed on surface etc.,complete with PVC boxes (Plastic on surfaceboxes) required for suitable number of modules (Modular accessories)nd covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- Wiring light point |
| 21 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars,earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuitbreakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- Supply and erection of SP&N Double Door Distribution Board 12 way each |
| 22 | Supply and erection of MCB Double Pole 50, 63amp. (10kA, Curve- C)34.16 A ( viii) ( 654.00 + 50% = 981.00 + 5.35% = 1033.48) Please Enable Macros to View BoQ information |