| 1 | Comprehensive, periodical preventive maintenance, repair and servicing of 3X50 TR Central AC Plant Located at P-5 FSD ,Voltas Model No:CWCDR0500MNT (01 x 50 TR running and 01 x 50 TR standby) comprising the installed machineries and accessories mainly semi hermetically sealed reciprocating compressors (01 x 50 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. |
| 2 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-104 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. |
| 3 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC2S-026AR2 ( 02X 25 TR running and 01 X 25 TR Standby) installed at P-105 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (02 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. |
| 4 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-106 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed.Note:- For BOQ Item No:1 to 4A. Accessories such as expansion valve, solenoid valve, liquid line valve, filter dryer, sensors, Microprocessor controller, MPVD relay, µMPD(M3PD) relay, copper pipe etc as given separately shall be measured and paid separately etc. B. Labour charges for taking down defective items i.e. pansion valve, solenoid valve, filter dyer and all connected accessories to machine from the unit and making connection/jointing suction/discharge pipe complete deemed to be included in the quotated rate.C. Gas and gas charging shall be measured and paid separately. D. Carry out preventive aintenance as per the standard practice in every month. E. This item include the cost of visiting the technician from authorised service dealer of blue star to check all parameters for smooth functioning of plant and will submit inspection report every month to Engr-in-Charge. F. Checking the system for any gas leaks and rectification of leaks if found. G. Taking set of readings and evaluating to ensure satisfactory performance of the plant. H. Checking the Central chiller plant control system for operation and djusting the settings. I. Checking of condenser unit and its accessories every month and take the reading of WT and LWT in hot and cold side and set CR at prescribed value. J. Checking the ctioning of scroll/Semi hermetic reciprocating compressor every month and its accessories. K. Checking of Evoprator unit (Chiller unit) and its accessories every month and take the reading of EWT and LWT in hot and cold side and set CR at prescribed value. L. Replacement of refrigerant gas as a result of fare wear and tear.cost of refrigerant gas will be measured and paid separately as supply only. M. Periodical checking of compressor oil and changing if found necessary (rate of changing of compressor oil deemed to be included in quotated rate). N. Checking of the central chiller plant control panel for its proper functioning and replacement of unserviceable accossaries connected to the control panel like fuse,wiring and other minor items are deemed to be included in quotated rate. O. AMC should be carried out within 03 day from the date of receipt by the contractor .Any delay beyound 03 day shall be compensated through panel recovery @ 1000 per day. |
| 5 | Supply only refringent gas R-134A/R-22 for AC plant by contractors cylinder |
| 6 | Supply only refringent gas R-407C for AC plant by Contractor cylinder |
| 7 | Supply only LP/HP cutout suitable for existing AC plant . |
| 8 | Supply only safety/failure switch Suitable for existing AC plant. |
| 9 | Supply only solenoid valve Suitable for existing AC plant. |
| 10 | Supply only V belt for blower fan motor/Compressor as per sample |
| 11 | Supply only compressor oil. |
| 12 | Supply only pressure gauge for suction/discharge for refrigerant R-22/R-407C. as approved by GE. |
| 13 | Supply only hand shut off valves/angle valve of any size suitable for existing AC plant |
| 14 | Supply only power contactor of capacity 120 - 130 Amps, 415 Volts, 3 phase, 50 Hz. |
| 15 | Supply only power contactor of capacity 40-45 Amp , 415 Volts, 3 phase, 50 Hz. |
| 16 | Supply only power contactor of capacity 20-25 Amp , 415 Volts, 3 phase, 50 Hz |
| 17 | Supply only contactor of capacity 6-18 Amp , 415 Volts, 3 phase, 50 Hz, |
| 18 | Supply only star delta Timer programmable Electronic timer switch having power requirment 24 V AC/DC power consumption 5W, Electronic timer 3-60 sec with 1 NO inst & 1 No delayed complete all as specified and directed |
| 19 | Supply only over load relay for motor/pumps havimg current rating up to 22 Amps,3 Pole,415 V, |
| 20 | Supply only over load relay for motor/pumps up to 28-54 Amp,3 Pole,415 V, |
| 21 | Supply only over load relay for motor/pumps 68-125 Amp Amps,3 Pole,415 V, |
| 22 | Supply only suction reed valve for compressor 5 H 60, as approved by GE. |
| 23 | Supply only discharge reed valve for compressor 5H 60, as approved by GE. |
| 24 | Supply only lub oil filter element of compressor suitable for 5H 60 ac plant compressor Please Enable Macros to View BoQ information |
| 25 | Supply only lub oil filter element of compressor suitable for 5H 60 ac plant compressor Please Enable Macros to View BoQ information |