| 1 | (1) Construction of Phy, Chem, Bio lab at UPGHIGH SCHOOL BARGHUTUA, DIST: RAMGARH, BLOCK: PATRATU (20241302601)(2) Construction of Phy, Chem, Bio lab at C.C.L. H.S., NAYANAGAR, DIST: RAMGARH, BLOCK: PATRATU (20241308307)(3) Construction of Phy, Chem, Bio lab at SHARMIK HIGH SCHOOL SIRKA, DIST: RAMGARH, BLOCK: RAMGARH (20241408405)(4) Construction of Phy, Chem, Bio lab at RAMGARH HIGH SCHOOL KOIRITOLA, DIST: RAMGARH, BLOCK: RAMGARH (20241411504)(5) Construction of Phy, Chem, Bio lab at UPG H.S CHAKRAWALI, DIST: RAMGARH, BLOCK: GOLA (20240706102)(6) Construction of Phy, Chem, Bio lab at UPG HIGH SCHOOL UDLOO, DIST: RAMGARH, BLOCK: MANDU (20241201101)(7) Construction of Phy, Chem, Bio lab at S.S. H.S. MANDU, DIST: RAMGARH, BLOCK: MANDU(20241209703) |
| 2 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification anddirection of E/I. |
| 3 | Extra for earth work in hard soil as per specification and direction of E/I. (videclassfication of soil item - B) 50% of excavated earth |
| 4 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compactedvolume). |
| 5 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compactedvolume). |
| 6 | Providing designation 75B brick work inC.M. (1:6) in foundation and plinth with approved quality of clean coarse sand ofF.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as perbuilding specification and direction of E/I. |
| 7 | Providing designation 75 B brick work inC.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per buildingspecification and direction of E/I. |
| 8 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone- III): 6 graded stone aggregate 40 mmnominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Centering and shuttering including strutting, propping etc. and removal ofform for Foundations, footings, bases of columns,etc. for mass concrete |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings,balconies and access platform |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders,bressumers and cantilevers |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Postsand Struts |
| 18 | Foundations, footings, bases of columns, etc. for mass concrete Weather shade, Chajjas, corbels etc., including edges |
| 19 | Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (TMT coil Fe 500) {Only Valid for TATA (TISCON) SAIL, JSPL, Electrosteel Steels ltd. Bokraro & Vizag(RINL)} 8 mm to 32 mm dia (TMT coil Fe 500) {Only Valid for TATA (TISCON) SAIL, JSPL,Electrosteel Steels ltd. Bokraro &Vizag(RINL)} 8# dia@ 30% |
| 20 | 10# dia@20% |
| 21 | 12#-25# dia @ 50% |
| 22 | Providing and fixing fan hooks of 16mm diaM.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building specificationand direction of E/I. |
| 23 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction ofE/I. |
| 24 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and directionof E/I. |
| 25 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 26 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per buildingspecification and direction of E/I. |
| 27 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 28 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surfaceeven and smooth complete. |
| 29 | S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Wherematerials is not supplied by the deptt.) |
| 30 | Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawingspecification and direction of E/I. |
| 31 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in buildingspecificatio). |
| 32 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 33 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawingspecification and direction of E/I. |
| 34 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in buildingspecificatio). |
| 35 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 36 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification anddirection of E/I. |
| 37 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with finesand including finishing the top smooth. |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement :4 coarse sand) : 25 mm thick |
| 39 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 40 | Providing and laying vitrified Parking / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 4457:2007, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 x 10 mm sizes. |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermalexpansion, Single socketed pipes |
| 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gapfor thermal expansion. Coupler - 110mm |
| 43 | Bend - 110mm |
| 44 | Shoe - 110 |
| 45 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making goodthe wall etc. complete 110 mm |
| 46 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. Raj Nagar Plain white marble/ Udaipurgreen marble/ Zebra black marble Area of slab upto 0.50 sqm |
| 47 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions Pre-laminated particle board withdecorative lamination on both sides.of engineer-in-charge. |
| 48 | HINGES |
| 49 | TOWER BOLT |
| 50 | HANDLE 125MM |
| 51 | SECOND CLASS DEODAR WOOD PLANKS |
| 52 | Carriage of materials Bricks Lead = 1 k+7 P(8km) |
| 53 | Sand lead = 10 km |
| 54 | Stone chips lead = 22 km |
| 55 | Stone metal lead = 22 km |
| 56 | Local Sand lead = 3km |
| 57 | Point wiring in PVC consuit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required |
| 58 | Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc asrequired. |
| 59 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit asrequired. 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 60 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 61 | 4x6 Sqmm + 2x6 sqmm earth wire (For 32 A IT Socket ) |
| 62 | S/F piano type switch/socket -Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required. 5/6 amps, one way switch |
| 63 | 3 pin 5/6 amps, socket outlet |
| 64 | S/F Modular type electronic fan regulator:- Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc asrequired. |
| 65 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc asrequired. |
| 66 | S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 67 | S/F Batten / Angle Holder:- Supplying and fixing batten / angle holderincluding connection etc as required. |
| 68 | Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, single door |
| 69 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections,testing and commossioning etc. as required. 6/32, single pole, \\"B\\" series |
| 70 | S/F DP MCB Isolator -Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amp |
| 71 | Supplying and fixing of 9/10 Watt LED Bulb |
| 72 | Supplying and fixing LED Batten (20/22W) |
| 73 | Supply of LED Street light (45/48W) |
| 74 | Supply and installation of Ceiling fan 48\\" (1200mm) |
| 75 | Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specificationand direction of E/I. |
| 76 | Providing and fixing brass/C.I. stop cock of approved quality all complete as perspecification and direction of E/I. (A) 15MM DIA BRASS STOP COCK |
| 77 | Providing and fixing Gun metal full way valve of approved quality, all complete,as per specification and direction of E/I. 32 mm and weight not less than 700gms. |
| 78 | Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and directionof E/I. (ii)250mm thick wall |
| 79 | Supplying, fitting and fixing bathroom fittings of approved make and as per ISI specification all cost complete as per direction of E/I. (all rates have beenadopted from the basic rate from SOR piller Cock (Long Neck) (for basin) |
| 80 | Providing and supplying in standard (a) 160 mm dia pipe |
| 81 | (b) 225mm dia |
| 82 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thickP.C.C. (1:3:6) in foundation and refillingall complete as per specification and direction of E/I. |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete15 mm nominal outer dia |
| 84 | 20 mm nominal outer dia |
| 85 | 25 mm nominal outer dia |
| 86 | 32 mm nominal outer dia |
| 87 | KITCHEN SINK |
| 88 | polythene water storage tank of mark with covei and suitable locking system in double layer confirming to lS: 12701- 1996 with Latest revision. |
| 89 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Singlesocketed pipes 110 mm Rain water pipe--waste pipe |
| 90 | Coupler 110 mm |
| 91 | Bend - 110mm |
| 92 | Shoe - 110 |
| 93 | TITLE Magnetic Green Dry Erase Writing board ofdimensions (in mm) 1200 x 1800 TITLER (4*6 WBCeramic Millimeter. Alkosign(ATR NBC 90180) |
| 94 | Gaatha Low-back Chair With Fixed armrest with Cushion |
| 95 | KEC Material Tabl e Furniture Asse mbly (Golden) |
| 96 | Alpha Powder coated R ectangular Classroom S toolsLoad of 75 Kg |
| 97 | Fire Extinguisher 04 kg ABC Powder, Store Pressure, ISI Mark, Portable |
| 98 | labour cess Please Enable Macros to View BoQ information |