Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL PORTION OF WORK:-Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).(i) Ground Floor |
| 2 | Earth work in excavation of foundation in hard soil within 50 m initial lead and 1.5 mt intial lift including shoring, shuttering, propping bullahs, piling, dewatering from foundation, supplying & working pumps & stacking the excavated materials away from the working area including rough dressing and breaking clods to maximum 5cm to 7 cm and laying in layers not exceeding 0.3 m in depth including cost, conveyance,taxes, cess, royalities of all materials, cost of all labour, T&P required for the work etc complete as per specifiction & direction of Engineer -in -charge.(i) Ground Floor |
| 3 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not Exceeding 23 cm .in depth with all lead and lift including cost, Conveyance, Loading, unloading, Royalties and taxes of all materials, cost of all labour. labour cess, sundries, T&P required for work etc .complete in all respect as per direction by the Engineer in charge.(i) Ground Floor |
| 4 | Cement Concrete of prop.(1:3:6) in foundation up to lowest bed level using crusher broken hard black granite metal of size 4cm down graded of approved quality from approved quarry as per approved design including hosting, lowering, laying compacting concrete in layers not exceeding 6\\"thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty & taxes of all materials, with labour T&P required for the work etc. complete in all respects including dewatering if required as per direction of engineer-in -charge.(i) Ground Floor |
| 5 | Cement concrete of proportion (1:2:4) using 12mm (1/2 \\") size hard granite crusher broken chips of approved quality from approved quarry and including lowering laying concrete watering and curing etc. complete to the required levels laid in layers not exceeding 15cm. thick including cost and conveyance, royalities and taxes of all materials and cost of all labour with T&P required for the work complete.(i) Ground Floor |
| 6 | Providing lifting, hoisting and laying R.C.C. of M-20 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.(A) Column base footing(i) Ground Floor |
| 7 | (B) Column in Super Structure(i) Ground Floor |
| 8 | (C) Plinth Band(i) Ground Floor |
| 9 | (D) Split Lintel over opening(i) Ground Floor |
| 10 | (F) Floor Beam(i) Ground Floor |
| 11 | (G) Chajja(i) Ground Floor |
| 12 | (H) Roof slab(i) Ground Floor |
| 13 | Supplying, cutting, straightening of steel HYSD (Fe- 415) conforming to (IS- 1786) with bending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering & laying steels including cost conveyance, taxes & royalties of all materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. Complete in all respect as per the direction of Engineer in charges (payment will be made on weight of MS rod or tor steel only basing on the co- efficient of MS rod or tor steel bars approved by SAIL / TATA / competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.).(i) Ground Floor |
| 14 | First class Fly ash Brick masonry using bricks of size 25 cm. x 12 cm. x 8 cm. (with dimensional tolerance of +85%) having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge..(i) Ground Floor |
| 15 | Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.(i) Ground Floor |
| 16 | Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.(i) Ground Floor |
| 17 | Providing 12 mm thick cement plaster (1:6) (1 cement : 6 sand) to outside plastered surface / plumped surface of masonar, racking out joints, cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalities, scaffolding, watering, curring, sundries, tools and plans etc complete as per direction of E.I.C.(i) Ground Floor |
| 18 | Providing 16 mm thick cement plaster (1:6) (1 cement : 6 sand) to rough surface of masonary, racking out joints, cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalities, scaffolding, watering, curring, sundries, tools and plans etc complete as per direction of E.I.C.(i) Ground Floor |
| 19 | Providing 6mm thick cement plaster (1:4) (1 cement : 4 sand) to R.C.C surface including close & deep chipping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalities, scaffolding, watering, curring, sundries, tools and plans etc complete as per direction of E.I.C.(i) Ground Floor |
| 20 | Supplying, fitting and fixing Vitrified tile in floors of approved make confirmating to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. |
| 21 | Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete. |
| 22 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge |
| 23 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge.(i) Ground Floor |
| 24 | Primering one coat with any approved shade of primer of approved make over the plastered surface of walls including cost, conveyance and taxes of all labour with T&P required for the work etc. complete as directed by the Engineer-in-charge. |
| 25 | Wall painting two coats with plastic emulsion paints of approved shade on new work by means of brush including watering and curing etc. complete including cost of paint with taxes and cost of all labour with T & P required for the work etc. complete. |
| 26 | Wall painting 2 coats with weather coat cement paint of approved shade on outer wall surface over a coat of water bound wall cement primer to give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding including all costs of labour etc. complete as per direction of E.I.C.(i) Ground Floor |
| 27 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. |
| 28 | Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete |
| 29 | Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows & ventilabours |
| 30 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 31 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primmer & labour to give an even shade excluding cost of primer. (As per A.R. 93/1) |
| 32 | Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. |
| 33 | Providing 25 mm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips using 2% water proofing cement compound (Make -sika/fosroc/Equivalent) on new work |
| 34 | P.H. PORTION OF WORK:-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.(A) 20mm dia C - PVC pipe |
| 35 | (B) 25mm dia C - PVC pipe |
| 36 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 37 | (ii) Elbow |
| 38 | (iii) 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 39 | (iv) 15mm dia CP Bib cock(Jaquar-Medi series)FLR-CHR-5043N |
| 40 | (v) 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 41 | (vi) 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 42 | (vii) 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 43 | (viii) 25mm dia brass full way valve (Shakti make) |
| 44 | (ix) 32mm dia brass full way valve (Shakti make) |
| 45 | (x) 15mm CP Extension piece |
| 46 | (xi) 125mm CP grating |
| 47 | (xii) 15mm size C.P. flange |
| 48 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) 110mm U-PVC SWR Pipe (Supreme / ahirvad) |
| 49 | (ii) 110mm U-PVC ‘P’ Trap (Ori Plast / Finolex / Supreme Make) |
| 50 | (iii) 110mm U-PVC door bend (Ori Plast / Finolex / Supreme Make) |
| 51 | (iv) 110mm U-PVC Plain bend (Ori Plast / Finolex / Supreme Make) |
| 52 | (v) 110mm U-PVC offset without ear (Ori Plast / Finolex / Supreme Make) |
| 53 | (vi) 110mm U-PVC Cowl (Ori Plast / Finolex / Supreme Make) |
| 54 | (vii) 110mm U-PVC S/Jn door (Ori Plast / Finolex / Supreme Make) |
| 55 | (viii) 110mm U-PVC Plain tee (Ori Plast / Finolex / Supreme Make) |
| 56 | (ix) 110mm U-PVC Door tee (Ori Plast / Finolex / Supreme Make) |
| 57 | (x) 110mm U-PVC Socket (Ori Plast / Finolex / Supreme Make) |
| 58 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 59 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 60 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge |
| 61 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend (Slimline - white - Parryware make) |
| 62 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan)with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) European water closet with P trap plain (Hindware / Parryware / Neycer make) |
| 63 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(i) 550mm x 400mm W.H.basin (Hindware / Parryware / Neycer make) with 15mm dia C.P.pillar cock (Plaza make) with pedestal |
| 64 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.(i) 25mm x 600mm long CP towel rail |
| 65 | (ii) Towel ring |
| 66 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.(i) 600mm x 125mm plate glass shelf with CP/NP guard rails. |
| 67 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.(i) 600mm x 450mm size B.E mirror (swivelled type) |
| 68 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.(i) CP soap holder |
| 69 | Providing fitting, fixing of Aluminium door with anodized AL. door section of 9202 as vertical member, 9201 as top and 9200 as middle bottom member with frame section No. 9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1855 Including all Cost of Labour. T&P hire charges of drilling machine. labour charges etc. complete. Ref : OBI10 |
| 70 | Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. length x 0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60m X 1.60m and 0.10m thick, RCC beam of 0.25m x 0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering, watering, curing, cost of all materials, conveyance of all materials to worksite, payment of royalty, all taxes etc.all complete as per approved drawing, P.H. specification and direction of Engineer-in-charge.(i) 2000 liters capacity PVC water storage tank |
| 71 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size crusher broken hard black granite chips including watering, curing, cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 72 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site, payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. (ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria / Somany / Johnson tile 30cm x 30cm special printed series to be pre-approved by the Engineer-in-charge).(i) Kajaria / Somany / Johnson tile 30cm x 30cm Ground Floor |
| 73 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 74 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing, cost of all materials, conveyance of all materials to work site, payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. (ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria / Somany / Johnson tile 45cm x 30cm special plain / printed series to be pre-approved by the Engineer-in-charge).(i) Kajaria / Somany / Johnson tile 45cm x 30cm Ground Floor |
| 75 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg / CM2 in CM (1:6) for the remaining 0.4572mm height of wall at top CC(1:3) inside and outside inside fill with dry brick khoa size 38mm, CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mm thick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 76 | Supplying all materials, labour, T&P and constructing Inspection Chamber of inside size 760mm x 760mm x 460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed, KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, cost of all materials, conveyance of all materials to worksite, payment of royalty, all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge.(i) Inside size 76cm x 76cm x 46cm with 18 inch dia RCC MH cover |
| 77 | 1 No. 30 Users Septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 78 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earth work in general. |
| 79 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 80 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 81 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 82 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 / Fe-500 grade for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, cost of steel, conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per PWD specification and direction of the Engineer-in-charge. |
| 83 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge.(i) RCC floor, roof slab chhaja up to 4.430 m height |
| 84 | Supplying all materials, labour, T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance + 8% in cement mortar (1:3) including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 85 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) on brick work including watering, curing, cost of all materials, conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per PWD specification and direction of the Engineer-in-charge. |
| 86 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 87 | Supplying all materials labour T&P and fitting and fixing12mm dia MS/CI step iron including supply of necessary CC (1:2:4) for fixing etc. complete as per PH specification. |
| 88 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering, curing, conveyance of all materials to work site, payment of royalty, all complete as per specification and direction of Engineer in charge. |
| 89 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc. all complete as per direction of Engineer-in-charge. |
| 90 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories.Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm / 150mm dia G.I / P.V.C / M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I / P.V.C / M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only.(A) Drilling of 200mm dia bore(i) 00 mtr to 30mtr |
| 91 | (ii) 30 mtr to 45mtr |
| 92 | (B) Drilling of 150mm dia bore(i) 45 mtr to 215.00mtr |
| 93 | Lowering the following size of G.I / P.V.C / M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.(A) Lowering of 200mm dia P.V.C casing pipes(i) 00 mtr to 30 mtrs |
| 94 | (ii) 30 mtr to 60mtr |
| 95 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1 / DIN - 42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC / Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.(i) 200mm dia PVC (sch-80) pipe |
| 96 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI / PVC / MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department). |
| 97 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge.(i) By DTH Rig |
| 98 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:(i) Rocky terrain with boulder formation for 300m depth |
| 99 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI / PVC / HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. (Texmo / Crompton Greaves / Kirloskar make).(i) 1 H.P. Single phase / three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 100 | (ii) DOL Control panel |
| 101 | (iii) 40mm dia steel short piece |
| 102 | (iv) Well cap |
| 103 | (v) 50mm size CI bracket |
| 104 | (vi) 2.50sqmm flat cable |
| 105 | (vii) 20mm dia rigid UPVC pipes |
| 106 | (viii) Steel rope with cover |
| 107 | (ix) Labour charges for lowering including transportation |
| 108 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984 / 2000 (10kgf / sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(i) 32mm HDPE pipes (Finolex / Supreme make) |
| 109 | EI PORTION OF WORK:-(A) Sub-Head I (modular Wiring Items)Recessed wirring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make - Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI / Gloster with 20 mm dia HMS FRLS PVC conduit ISI marked Make - AKG / BEC / Precision / Norpak / Anchor / Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make - Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision) of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer - in - Charge. (i) GROUP-A |
| 110 | (ii) GROUP-B |
| 111 | (iii) GROUP-C |
| 112 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (flame retradant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make - Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision). |
| 113 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) (flame retradant type) with suitable size modular box & metallic cover plate (both side) (flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg - in - charge. Make - Schneider (Zencelo) / legrand (Myrius ) / Panasonic (vision) (For equipement power) (Maximum 02 nos point in one circuit). |
| 114 | Supplying, fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (flame retradant type) with suitable size modular box & cover (flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg-in-charge. Make - Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision) |
| 115 | Supplying and installation of 25A AC starter Modular type, Schneider / Siemens / Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge . |
| 116 | Supply and fixing CALL bell (Ding dong type) / Buzzer on the existing switch box/cover. Make - Schneider (Zencelo) / legrand (Myrius) / Panasonic (vision) as required as per direction of Engg.-in-Charge. |
| 117 | Supply of computer board with 3 nos 5 amp switch & socket of approved ISI Make. |
| 118 | (B) Sub Main WiringRecessed wiring for circuit / submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make - Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI / Gloster in recessed HMS FRLS PVC conduit of mentioned size Make - AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB / LIGHT CKT) (2X1.5+1X1.5) |
| 119 | Recessed wiring for circuit / submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make - Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI / Gloster in recessed HMS FRLS PVC conduit of mentioned size Make - AKG / BEC / Precision / Norpak / Anchor /Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (BDB to LSB / LIGHT CKT / 5A PLUG / UPS POINT) (2X2.5+1X1.5) |
| 120 | Recessed wiring for circuit / submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make - Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI / Gloster in recessed HMS FRLS PVC conduit of mentioned size Make - AKG / BEC / Precision / Norpak / Anchor /Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (PDB to PSB / POWER POINT / AC POINT) (2X4+1X1.5) |
| 121 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 122 | S/F of Bakelite angle holder / batten holder (make-Anchor / Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge. All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 123 | S/F of 9 watt LED Bulb of approved ISI Make (Crompton / Bajaj / Havells) |
| 124 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision) |
| 125 | (C) Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, testing and commssioning of 1200 mm sweep white / milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥ 215m3/min Make - Crompton Energion Groove / Havells Efficiencia Neo / Usha Technix) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge, Replacement Warranty will be 4 years. |
| 126 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic / LT / Havells / Philips / Wipro / Crompton / Bajaj). |
| 127 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing, High optically efficient diffuser, above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic / LT / Havells / Philips / Wipro / Crompton / Bajaj). The luminaire should be Replacement Warranty will be 2 years |
| 128 | Supplying, installation, of Exhaust fan of heavy duty 250 mm sweep 1400 rpm with louvers (Make- Havells / Crompton / Usha / Orient / Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. |
| 129 | Supply and fixing of 10 Watt LED BH Fitting (panasonic / havells / LT / Bajaj / Phillips / Crompton / Wipro). The luminaire should be Replacement Warranty will be 2 years. |
| 130 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated, die-cast Alluminium housing with high quality frosted diffuser for glare- free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, CRI not less than 80,CCT of 6000 degree K, THD less than 10%, with electronic driver, internal surge protection of 3 KV, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make : Panasonic / LT / Havells / Philips / Wipro / Crompton / Bajaj). The luminaire should be Replacement Warranty will be 2 years |
| 131 | POWER BACKUP:-S/F of 150 AH tubular Inverter Battery 2 No. with 2250 watt sine wave UPS (EXIDE / LUMINOUS / Microtek) with trolly arrangement. |
| 132 | (D) BDBS, DB, AC DB, FLOOR PANELS, MCBSSupplying and fixing of following mentioned way, three pole / single pole and neutral, sheet steel, double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3, integrated door earthing system offering additional safety to the user, High quality polyurethane Gasket, the box and cover shall be fabricated to withstand IK09, the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks, with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make - LEGRAND - Ekinox3 DB / Siemens-Betaguard / Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.(a) S/F of 12 way SP MCB DB DD type of an approved ISI Make (Anchor / L&T / Havells / Schneider) |
| 133 | (b) Supplying and fixing 20 - 32 amps rating, 240 volts, C series, 10KA breaking capacity, Double poles MCB of Make - LEGRAND-DX3 / Siemens - Betaguard / Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 year. |
| 134 | (c) Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, 10KA breaking capacity, single poles MCB of Make - LEGRAND - DX3 / Siemens - Betaguard / Schneider - Acti 9 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 135 | (E) Earthing InstallationSupplying, installation, testing & commissioning of materials and installation of Copper earth plate 600mm x 600mm x 3.15mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 136 | Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 137 | (F) Main PanelS/F of 100A. ICTPN main switch |
| 138 | S/F of Street light- 60W, 120 lm/w efficiancy, IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover (Make: Bajaj / polycab / crompton/Eq.) |
| 139 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property Aluminium conductor power cable of 1.1 KV grade Make - Finolex / Polycab / HAVELLS / RR KABLE / KEI / Gloster of following size cables as per direction of Engg.-in-Charge. (a) 4 core x 16 sq mm |
| 140 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable as per direction of Engg.-in-Charge. (a) 4 core x 16 sq mm |
| 141 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex / Fireshield / Ceasefire |
| 142 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make - Safex / Fireshield / Ceasefire |
| 143 | Supply & laying of 1x 2.5 mm2 sub main for Inverter wiring Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail