| 1 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 2 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 3 | Demolishing mud phaska in terracing and disposal of material within 50 meters lead |
| 4 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead of area of 3 sqm. and below |
| 6 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 9 | Extra for brick work with common burnt clay bricks /cement concrete bricks in superstructure above plinth level upto floor five level |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Centring and Shuttering including strutting, propping etc and removal of form work for Weather shades, chajjas, corbels etc. including edges. |
| 13 | 12mm cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand) |
| 14 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 coarse sand) |
| 15 | 20mm Cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand) |
| 16 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 17 | Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 Coarse sand) |
| 18 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm thick Second class Kail wood |
| 19 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm |
| 20 | Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm |
| 21 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 23 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer |
| 25 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 26 | Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work |
| 27 | Finishing walls with Acrylic smooth exterior paint of required shade: Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface) |
| 28 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work. |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 31 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Single socketed pipes 110 mm diameter. |
| 32 | Supply and Fixing of Internal and External Electricfication incl from Service Main To The Meter Point And Then To The Main Circuit Board, Switches, Socket , Switch Board, MCB etc Ready To Use with Instruction of Site Engineer Incharge all complete including Battens wherever required |
| 33 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. |
| 34 | Sand for an average lead of 80 kms. |
| 35 | Stone aggregate below 40mm size for an average lead of 20 kms. |
| 36 | Bricks for an average lead of 20 kms. Please Enable Macros to View BoQ information |