| 1 | Note:- Please refer Schedule 'A' Notes given on serial page No. 19 to 29 of tender documents. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule 'A' Part-I brought forward from serial page No.30. |
| 4 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-II brought forward from serial page No.31. |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 32, 33(R) to 35(R). |
| 6 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 36(R). |
| 7 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 37. |
| 8 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 38. |
| 9 | Lump sum price worked out by the contractor for COMPOUND WALL FENCING AND GATE WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 39 & 40. |
| 10 | Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 41 & 42. |
| 11 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 43. |
| 12 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 44 to 47. |
| 13 | Lump sum price worked out by the contractor for DG SET WORK as listed in Schedule 'A' Part-XI brought forward from serial page No. 48. |
| 14 | Lump sum price worked out by the contractor for LIFT WORK as listed in Schedule 'A' Part-XII brought forward from serial page No.49. |
| 15 | Lump sum price worked out by the contractor for FIRE FIGHTING, FIRE ALARM & DETECTION SYSTEM WORK WORKS as listed in Schedule 'A' Part-XIII brought forward from serial page No. 50 & 51. |
| 16 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORK as listed in Schedule 'A' Part-XIV brought forward from serial page No. 52. |
| 17 | Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS as listed in Schedule 'A' Part-XV brought forward from serial page No. 53 & 54(R). |
| 18 | Lump sum price worked out by the contractor for SOLAR WATER HEATER WORK as listed in Schedule 'A' Part-XVI brought forward from serial page No. 55. |
| 19 | Misc items of Works (To be quoted by Bidder) as listed in Schedule 'A' Part-XVII |
| 20 | INTERNAL WATER SUPPLY WORKS |
| 21 | Supply & fixing 15mm CP brass health faucet (hand shower), inlet length 100mm fixed to angle valve with and including decorative choice flexible pipe, wall hanger etc including all necessary fittings for fixing with pipe complete all as specified and directed. |
| 22 | Supply & fixing 15mm bore fancy type central hole single lever basin mixer with 450 mm braided connection pipe including all necessary fittings for fixing with pipe complete all as specified and directed.Make Cera Model No F2013451 / JaquarQQP‐CHR‐7167BPM / Roca T5A8497CA1 / Kohler Model no. K‐ 27484IN‐4‐CP |
| 23 | Supplying and fixing two way bib cock with single handle and wall flange 15mm dia, fancy type chromimum plated including all necessary fittings for fixing with pipe complete all as specified and directed. Make Cera Model No F2013163 / Jaquar LYRCHR‐38041 / Kohler Model no K‐16094IN‐4‐CP / Roca Model no.RT5A937ACA1 |
| 24 | Supply & fix 15 mm bore Sink Mixer with Swinging Spout (Wall Mounted) with 150mm long swivel spout Connecting Legs & Wall Flanges including all necessary fittings for fixing with pipe complete all as specified and directed. Make Cera Model No F2013501 / JAQUAR Model no ARI‐CHR‐39165 / Kohler Model no. K‐20591IN‐4‐CP / Roca Model no. RT5A8497CA1 |
| 25 | Supplying and fixing Wall Mounted Bib Cock, Chromium Plated, with wall flange & aerator (Cera Cat no. F1015151) / Jaquar‐ 16094IN‐4‐CP/ Roca RT5A937ACA1 / Kohler Model no 16093IN‐4‐CP including all necessary fittings for fixing with pipe complete all as specified and directed. |
| 26 | Supplying and fixing 32 mm UPVC Ball valve with screwed both ends pipe and fixed all as specified and directed |
| 27 | INTERNAL ELECTRIFICATION WORKS |
| 28 | Material & labour for point wiring with 1.5 sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed. Note:- Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respect items (a) Fan point/ exhaust fan point /one light point/bell/buzzer controlled by one switch/bell push. |
| 29 | (b) One modular socket outlet 5 pin 5 Amp controlled by one, one way switch on same board. |
| 30 | (c) One modular socket outet point 5 amps on the independent board. |
| 31 | (d) One light point controlled by two nos of two way switch. |
| 32 | All as Ser item 4.02 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 33 | Supply and fix modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 8 module complete all as specified and directed. |
| 34 | Supply and fix modular metal flush box made out of GI sheet, thickness not less than 1.2mm with earthing terminal, 12 module complete all as specified and directed. |
| 35 | Supply and fix modular Dummy plate complete all as specified and directed. |
| 36 | Supply and fix LED energy efficient LED bulb B22, 9 watt complete all as specified and directed. |
| 37 | Supply and fixing VTPN DB’s 4 Way, Double door, 415V, IP43, suitable size and length of CRCA steel sheet, dust protection duly powder painted including factory fitted suitable size copper bus bar, 01 No of MCCB TPN as incomer and 04 Nos TP as outgoing with neutral link, earth bar, din bar for mounting MCB and blanking plate a complete all as specified and directed. Note:- MCB shall be measured and paid for separately. |
| 38 | Supply and fixing TV socket and connector complete with all necessary fittings all as specified and directed. |
| 39 | Material & labour for wiring with 1100 volt grade one single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 1.5 sqmm (FOR INVERTER) drawn into PVC conduit with all accessories fixed concealed complete all as specified and directed. |
| 40 | Supply and fix LED tube light fitting in extruded aluminium housing for all purpose surface and wall mounted with single side connection aluminium LED batten with 125 Lum/watt system efficancy polycarbonate housing and integrated electronic driver of capacity 20 W, four feet and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. Make: Havells cat part No. ENDURALINEARPROBS20WLED865SPCSSIND or equivalent make of Bajaj/Crompton/ Philips. |
| 41 | Supply and fix wall/ceiling mounting LED 9/10 Watt tube light fitting in extruded aluminium housing and integrated electronic driver complete with all acessories 1x9 Watt LED, with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. Make: Havells cat part No. LUMILINEBS9WLED865SPCWH or equivelent make of Bajaj/ Crompton/ Philips. |
| 42 | Supply and fix bldg street fitting made up of pressure dai cast aluminum housing with high efficiency LEDs as a lighting source and lens embedded PC Cover Having TOP oppening seperate driver compartment with IP 66 protection and impact resistance of IK07, CCT 5700 K, of wattage 25 Watt including connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal all as specified and as directed. Make :- Havells/ Bajaj/ HPL/Philips |
| 43 | Supply and fix GI pipe bracket made of GI pipe light grade 32mm dia and bend to shape 1.5 mtr long MS clamp made out of MS flat iron of size 32mm x 3mm with nut and bolts washer complete including drilling of holes for nut and bolts etc complete all as specified and directed. |
| 44 | Supply and fixing decorative type LED wall lights fitting 08/09 Watt, 220V, suitable for LED lamp B22 9 watt complete all as specified and directed. Make: Havells Cat No LHFOECCE1TZ1O014 or equivalent Philips/CG |
| 45 | Supply and fix Kitchan Wall Fan 300 mm sweep, 1350 RPM, of Elegantly designed fan base in round shape for 50 cub mtr/min air delivery and minimal noise levels with pull code control for speed & oscillation upto 90 degree total flexibility, double 'z' shielded ball bearing, sturdy brazed wire guards with power coating ensures corrosion resistance conforming to IS 2997-1964 complete all as specifed and directed. |
| 46 | Supply and fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless with Air outlet 150 mm, Steel Finish Front Matte Black Glass panel with Digtal Display Touch Control Panel with 3 Speed Gesture motion, Heavy Duty Baffle Filters, minimium Air flow 1180 M3/h Energy Saving LED Light of suitable wattage, Copper winding BLDC Motor, 62dba max noise level and voltage 220-240 V/50 Hz including making hole in the wall and making good the distubed surface of wall including all accessories all as specified and directed. Make : KAFF Model No.SKU NEVISHC90 or eqvt in Hindware/ Faber. |
| 47 | Supply, installation, testing & commissioning of 3-Φ, 4 Wire, AC Static Direct connected, Smart Pre-paid Energy Meters, ISI marked of different makes as per BIS-16444, with communication technology including GPRS/RF/Hybrid (RF Mesh Network+GPRS)/any other advanced technology as per CEA/TRAI regulations) with current range 10-60 Amp, 415 V, accuracy class 1.0 UC1 category and above along with in-built load control switch, containing provision for TOD & RTC, capable to define multiple tariff slabs complete all as specified and directed.Meter should support the following data:- (i) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, daily and monthly billing survey for Cumulative Energy and Max Demand(ii) Meter should have connect / disconnect functionality operable for MDM/billing software and prepaid features would be operable for MDM / Billing end as per IS: 15959 Part-2.(iii) Meter should support communication protocol through RF/ 5G/4G/NB IOT with the existing software in stn all as required at site and directed (cost of 5G/4G/NB IOT sim with two year recharge facilities, mapping, vending portal charges etc deemed to included in rate quoted for meter). (iv) The meter should support open communication protocol DLMS with the existing software.Make: Anchor/L&T/HPL/Secure.Note:- (i) The smart meter would be compatiable with existing software/DCU in Stn.(ii) The rate of sim as well as data pack of 24 months from date of completion for connectivity is deemed to be including in the quated rates. |
| 48 | Supply & fixing of Transparent polycarbonate Meter Box of suitable size with IP-54 for 3-Φ, 4 wire, Smart Energy meter mentioned here-in-above at Sch. Item No. 4.21. The Polycarbonate meter box shall comply with IS-14772:2000 and IS-11000:1984. It shall be totally shock proof, safe weater proof, rust roof, dust proof, water proof, halogen free, silica free and having internally embeded gasket technology, transparent hinged lid and sealing provision including bakelite connector, complete all as specified and directed. Make: Anchor by Panasonic/L&T/ HPL/Secure. |
| 49 | ROAD WORKS |
| 50 | Material and labour for preparing bituminous surface of road and marking 2.5mm thick hot applied thermo plastic road marking paint of approved colour providing retroreflecting glass beads @ 250 gm per Square metre as per IRC-135 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 51 | EXTERNAL WATER SUPPLY WORKS |
| 52 | Supply and laying ductile iron pipe of 100mm bore with spigot and socket ends centrifugally cement mortar lined complete as per IS 8329/ 2000 class K-9 with including suitable for tyton joint and jointing material/ joints laid in trenches complete all as specified and directed.Note ;- DI specials and earth work shal be measured and paid seperately. |
| 53 | S&F 80mm dia GI tubing heavy grade 'C' class with all new connections and fitting such as Tee, elbows, bend, reducer, unions, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc laid in threnches complete all as specified and directed. |
| 54 | Material & labour for valve pits and constructing of brick masonary pits of internal dimensions 900mm x 900mm x 900mm (bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:3:6) 51 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The sluice valve and other fittings should be housed in center of the pit. The verticesof the pit should in right angle and champhered. The top cover of the pit will be made out of MS sheet min 2 mm thick with angle iron frame made out of MS angle 50mm x 50mm x 6mm with galvanized steel hindges two nos and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide complete all as specified and directed. |
| 55 | Material and labour for taping from existing DI 80 mm to 150 mm including cutting, jointing, inserting Tee and alll accessories complete all as specifed and directed.Note:- Tee shall be measured and paid separately under respective items. |
| 56 | EXTERNAL ELECTRIFICATION WORKS |
| 57 | Supply, install, testing and commissioning of LT Distribution Panel (CPRI type tested ) cubicle type IP-65, outdoor type confirming to IS-61439 factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories/fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- Please Enable Macros to View BoQ information |
| 58 | Supply, install, testing and commissioning of LT Distribution Panel (CPRI type tested ) cubicle type IP-65, outdoor type confirming to IS-61439 factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories/fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of plateform. The plateform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- Please Enable Macros to View BoQ information |