| Sl. No. | Item Description |
| 1 | Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width AsWell As 10 Sqm On Plan) Including Getting Out And Disposal Of ExcavatedEarth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge.All Kinds Of Soil |
| 2 | Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. |
| 3 | Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materials |
| 4 | Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M Including Getting Out The Excavated Soil And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil |
| 5 | Cartage Of Material By Mannual Labour Inculding Loading ,Unloading & Stacking Up To 2Km |
| 6 | Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. |
| 7 | Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. |
| 8 | Supplying And Filling In Plinth With Gola Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. |
| 9 | Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: |
| 10 | Providing And Laying In Cement Concrte 1:4:8(1Cement :4Fine Sand:08Graded Brick Aggregated 40Mm .Nominal Size.) And Curing Complete Including Cost Of Form Work In Foundation And Floors. |
| 11 | Making Plinth Protection 50 Mm Thick Of Cement Concrete 1:3:6 (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Finishing The Top Smooth. |
| 12 | Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). |
| 13 | Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.All Works Upto Plinth Level |
| 14 | Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.As Per Design Mix Provided By Department. All Works From Plinth To 5Th Floor. |
| 15 | Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :) 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) |
| 16 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Ofform For : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete |
| 17 | Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. |
| 18 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Ofform For : Suspended Floors, Roofs, Landings, Balconies And Access Platform |
| 19 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Ofform For : Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers |
| 20 | Centering And Shuttering Including Strutting, Propping Etc. And Removal Ofform For : Columns, Pillars, Piers, Abutments, Posts And Struts |
| 21 | Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | Brick Work With Ist Class Bricks Of Class Designation 75 In Foundation And Plinth In: Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) In foundation and plinth. |
| 23 | Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) |
| 24 | Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) |
| 25 | Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry. |
| 26 | Brick Work With Common Burnt Clay Selected F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) |
| 27 | 6 Mm Cement Plaster Of Mix : 1:3 (1 Cement : 3 Fine Sand) |
| 28 | 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix :1:4 (1 Cement: 4 Fine Sand) |
| 29 | 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) |
| 30 | 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 (1 Cement: 6 Fine Sand) |
| 31 | 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix : 1:3 (1 Cement: 3 Fine Sand) |
| 32 | Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate |
| 33 | Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement: 4 Coarse Sand): 25 Mm Thick |
| 34 | Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 20 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm |
| 35 | Marble Stone Flooring With 18 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Grey Cement Slurry, Including Rubbing And Polishing Complete With :Udaipur Green Marble |
| 36 | Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7D,F4B, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10X10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) |
| 37 | Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works |
| 38 | Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete. Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1.4 Mm Aperture On Both Sides |
| 39 | Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 4.0 Mm Thick Glass Panes |
| 40 | Providing And Fixing Pressed Steel Door Frames Conforming To Is: 4351, Manufactured From Commercial Mild Steel Sheet Of 1.60 Mm Thickness, Including Hinges, Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25 Mm, Or Base Ties Of 1.60 Mm, Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Including M.S. Pressed Butt Hinges 2.5 Mm Thick With Mortar Guards, Lock Strikeplate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface As Directed By Engineerin- Charge: Profile B Fixing With Adjustable Lugs With Split End Tail To Each Jamb |
| 41 | Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws |
| 42 | Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : |
| 43 | Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Single Rubber Stopper |
| 44 | Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :300X16 Mm |
| 45 | Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 250X16 Mm |
| 46 | Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyedto Required Colour Or Shade, With Necessary Screws Etc. Complete :250X10 Mm |
| 47 | Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyedto Required Colour Or Shade, With Necessary Screws Etc. Complete : 150X10 Mm |
| 48 | Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Tinnable Priming Coat With Cement Primer |
| 49 | Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: New Work (Two Or More Coats Applied @ 1.43 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) |
| 50 | Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture |
| 51 | Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture |
| 52 | Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. |
| 53 | Finishing Walls With Water Proofing Cement Paint Of Required Shade New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) |
| 54 | Providing And Laying Integral Cement Based Treatment For Water Proofing On The Vertical Surface By Fixing Specified Stone Slab 22 Mm To 25 Mm Thick With Cement Slurry Mixed With Water Proofing Compound Conforming To Is:2645 In Recommended Proportions With A Gap Of 20 Mm (Minimum) Between Stone Slabs And The Receiving Surfaces And Filling The Gaps With Neat Cement Slurry Mixed With Water Proofing Compound And Finishing The Exterior Of Stone Slab With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 20 Mm Thick With Neat Cement Punning Mixed With Water Proofing Compound In Recommended Proportion Complete At All Levels And As Directed By Engineer-In-Charge : Using Rough Kota Stone |
| 55 | Grading Roof For Water Proofing Treatment With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) |
| 56 | Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1Mx1Mx400Micron, Finished With 12Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement Rounding The Edge Sand Making And Finishing The Outlet Complete. |
| 57 | Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes.110 Mm Diameter |
| 58 | Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5 Degree 110 Mm Bend |
| 59 | Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion.Shoe (Plain) 110 Mm Shoe |
| 60 | Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes. 110 Mm Diamete |
| 61 | Constructing Masonry Chamber 90X90X100 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep (Inside) With Chained Lid And Rcc Top Slab 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Including Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5 |
| 62 | Providing M.S. Foot Rests Including Fixing In Manholes With 20X20X10 Cm Cement Concrete Blocks 1:3:6 (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) As Per Standard Design : With 20X20 Mm Square Bar |
| 63 | Boring/Drilling Bore Well Of Required Dia For Casing/ Strainer Pipe, By Suitable Method Prescribed In Is: 2800 (Part I), Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart/ Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Charge, Beyond 90 Metre & Upto 150 Metre Depth Below Ground Level.300 Mm Dia |
| 64 | Supplying, Filling, Spreading & Leveling Stone Boulders Of Size Range 5 Cm To 20 Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. |
| 65 | Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Pvc Medium Well Casing (Cm) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire And Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer -In-Charge. 200Mm |
| 66 | Supplying, Filling, Spreading & Leveling Coarse Sand Of Size Range 1.5 Mm To 2 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. |
| 67 | Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Co Mplete As Per Standard Design With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Classdesignation 7.5 |
| 68 | Providing & Fixing Of Foot Rest In Tank |
| 69 | Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality 19.19.1 L D- 2.5 Rectangular Shape 600X450 Mm Internal Dimensions |
| 70 | Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality Cover To Be Not Less Than 108 Kg Each L D-2.5 Rectangular Shape 600X450 Mm InternalDimensions |
| 71 | Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Sfrc Cover And Frame (Heavy Duty Hd20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : |
| 72 | Providing And Laying Non-Pressure Np2 Class (Light Duty) R.C.C. Pipes With Collars 250 Mm Dia. R.C.C. Pipe 250 Mm Dia Rcc Pipes. |
| 73 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) |
| 74 | Providing and fixing panelling or panelling and glazing in panelled orpanelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.30 mm thick Fly proof stainless steel grade 304 wire gauge with 0.5 mmdia. wire and 1.4 mm wide aperture with matching woodbeading |
| 75 | Cement Plum masonry with 40% Plum & 60%1:3:6 Cement Concreteincluding Supply Of All Material, Labour, T&P Etc. Required For Proper completion Of Thework. Asperdrawingsandtechnicalspecificationsclause802, 803, 1202 & 1203 Of Mord Specifiction 803, 1202 & 1203 Of Mordspecifiction |
| 76 | Random Rubble Stone Masonry Laid In 1:6 Cement And Sand Mortar, In Breast Walls, Retaining Walls, Parapets, Scuppers, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction |
| 77 | Concrete With Cement, Coarse Sand And 40 Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 |
| 78 | Clearing Grass And Removal Of Rubbish -Clearing Grass And Removal Of Rubbish Up To A Distance Of 50 Metres Outside The Periphery Of The Area . |
| 79 | Excavation In Ordinary Rock Using Hydraulic Excavator And Tippers With Disposal Upto 1000 Metres. (Excavation For Roadwork In Soil With Hydraulic Excavator Including Cutting And Loading In Tippers, Trimming Bottom And Side Slopes, In Accordance With Requirements Of Lines, Grades And Cross Sections, And Transporting To The Embankment Location Within All Lifts And Lead Upto 1000M.) |
| 80 | Cast In Situ Cement Concrete M20 Kerb (Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Pcc On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Laid Manually, All Complete As Per Clause 408)Pcc M20 For Kerb (Cast In Situ) |
| 81 | Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. '15 Mm Dia. Nominal Bore |
| 82 | Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. 20 Mm Dia. Nominal Bore |
| 83 | Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.50 Mm Nominal Outer Dia Pipes |
| 84 | Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 |
| 85 | Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore. |
| 86 | Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 15 Mm Nominal Bore |
| 87 | Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 25 Mm Nominal Bore (Horizontal) |
| 88 | Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. |
| 89 | Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore |
| 90 | Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: |
| 91 | Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.L. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required : |
| 92 | Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Tap |
| 93 | Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required :Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm |
| 94 | Providing And Fixing Soil, Waste And Vent Pipes :100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 |
| 95 | Providing And Fixing Soil, Waste And Vent Pipes : 75 Mm Diameter : |
| 96 | Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron/Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10X10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Cost Of Cutting Holes And Making Good The Walls Etc. :For 110 Mm Dia Pipe |
| 97 | Providing And Fixing M.S. Holder-Bat Clamps Of Approved Design To Sand Cast Iron/Cast Iron (Spun) Pipe Embedded In And Including Cement Concrete Blocks 10X10X10 Cm Of 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Cost Of Cutting Holes And Making Good The Walls Etc. : For 75 Mm Dia Pipe |
| 98 | Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : |
| 99 | Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 A) 15 Mm Nominal Bore 15Mm Nominal Bore |
| 100 | Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing :Circular Shape 450 Mm Dia |
| 101 | Providing And Fixing 600X120X5 Mm Glass Shelf With Edges Round Off, Supported On Anodised Aluminium Angle Frame With C.P. Brass Brackets And Guard Rail Complete Fixed With 40 Mm Long Screws, Rawl Plugs Etc., Complete. |
| 102 | Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. |
| 103 | Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements, Weighing Not Less Than 106 Gms. |
| 104 | Providing And Fixing Double Equal Plain Junction Of Required Degree. 100X100X100Mm |
| 105 | Providing And Fixing Double Equal Plain Junction Of Required Degree. 75X75X75X75 Mm |
| 106 | Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 100 Mm Diameter Pipe |
| 107 | Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete 75 Mm Diameter Pipe |
| 108 | Providing Laying, Testing & Commissioning Of 'C' Class Heavy Duty Ms Pipe Conforming To Is 1239/3589 I/C Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. In Ground Including Welding, Excavation & Providing Cement Concrete Blocks As Supports, Anticorrosive Treatment With Coaltar/Asphalt Tape As Per Is 10221, Refilling The Trench Etc. Of Following Sizes Complete As Required.150 Mm. Dia |
| 109 | Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red, Conforming To Is 884 Complete With The Following As Required. 20 Mm Nominal Internal Dia Water Hose Thermoplastic (Textile Reinforced) Type -2 As Per Is: 12585. 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle. Drum And Brackets For Fixing The Equipmets On Wall. Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket.40 M |
| 110 | Supplying And Fixing Single Headed Internal Hydrant Valve With Instantaneous Unmetal/Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 (Type -A) With Blank Gunmetal/Stainless Steel Cap And Chain As Required :Single Headed Stainless Steel |
| 111 | Providing, Installation, Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required :150Mm Dia |
| 112 | Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire, Rivets Etc. Conforming To Is 636 (Type-A) As Required :Gun Metal |
| 113 | Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. |
| 114 | Providing & Fixing Flow Switch In Following Sizes M.S. Pipe Including Connection Etc As Required. |
| 115 | Supplying, Installation, Testing And Commissioning Of Electric Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : (A) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520. (B) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronous Speed 1500 Rpm, Suitable For OperationOn 415 Volts, 3 Phase 50 Hz, Ac Supply With Ip 55 Protection For Enclosure, Horizontal Foot Mounted Type With Class-'F' Insulation, Conforming To Is-325.(C) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.(D) Suitable Cement Concrete Foundation Duly Plastered With Anti Vibration Pads. 1620 Lpm At 56 M Head |
| 116 | Intelligent Fire Alarm System Supplying, Installation, Testing And Commissioning Of Micro Processor Based Intelligent Addressable Main Fire Alarm Panel, Central Processing Unit With The Following Loop Modules And Capable Of Supporting Not Less Than 240 Devices (Including Detectors) And Minimum 120 Detectors Per Loop And Loop Length Up To 2 Km, Network Communication Card, Minimum 320 Character Graphics/ Lcd Display With Touch Screen Or Other Keypad And Minimum 4000 Events History Log In The Non Volatile Memory (Eprom), Power Supply Unit (230 ± 5% V, 50 Hz), 48 Hrs Back-Up With 24 Volt Sealed Maintenance Free Batteries With Automatic Charger. The Panel Shall Have Facility To Connect Printer To Printout Log And Facility To Have Seamless Integration With Analog/Digital Voice Evacuation System (Which Is Part Of The Schedule Of Work Under Sh: Pa System) And Shall Be Complete With All Accessories . The Panel Shall Be Compatible For Ibms System With Open Protocol Bacnet/ Modbus Over Ip Complete As Per Specifications. |
| 117 | Supplying & Fixing Sand Bucket |
| 118 | Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C |
| 119 | Wgstlmidtc Twin Control Point Wiring In Pvc Conduit, With Modular Type Switch: Wiring For Twin Control Light Point With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required. |
| 120 | Wgstlpp2 Power Plug Wiring In Pvc Conduit (2X4 Sq. Mm) Wiring For Light/Power Plug With 2X4 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit Alongwith 1 No 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. |
| 121 | Wgstlsb Circuit/ Submain Wiring In Pvc Conduit: Wiring Fir Curcuit/ Submain Wiring Alongwith Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire |
| 122 | Wgstlsb Circuit/ Submain Wiring In Pvc Conduit: Wiring Fir Curcuit/ Submain Wiring Alongwith Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire |
| 123 | Wgstlsb Circuit/ Submain Wiring In Pvc Conduit: Wiring Fir Curcuit/ Submain Wiring Alongwith Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire |
| 124 | Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 2 Pair |
| 125 | Supplying And Fixing Of Following Sizes Of Pvc Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cuttting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25 Mm |
| 126 | Mb S/F Metal Boxes: Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. 75 Mm X 75 Mm X 60 Mm Deep |
| 127 | Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 Amps Switch |
| 128 | Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet |
| 129 | Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Telephone Socket Outlet |
| 130 | Modfreb S/F Modular Type Electronic Fan Regulator: Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. |
| 131 | Lpaccpt S/F Light Plug Point Modular Type Accessories: Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). |
| 132 | Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required. |
| 133 | Creb S/F Ceilling Rose: Supplying And Fixing 3 Pin, 5 Amp. Ceilling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc. As Required |
| 134 | Brhold S/F Brass Holder: Supplying And Flxing Brass Batten/Angle Holder Including Connection Etc. As Required. |
| 135 | Itcffsur Itc Fluorescent Fitting Directly On Surface: Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting/ Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. |
| 136 | Itccffc Itc Ceiling Fan With Cover On Fan Box: Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq, Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. |
| 137 | Itcef450 Itc Exhaust Fan Upto 450 Mm Sweep: Installation Of Exhaust Fan Upto 450 Mm Sweep In The Existingopening, Including Making The Hole To Suit The Size Of The Above Fan, Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. |
| 138 | Loushef Fixing Louvers/Shutters For Exhaust Fan: Extra For Fixing Louvers/Shutters Complete With Frame For A Exhaust Fan Of All Sizes. |
| 139 | Board & Db'S Pwtpmcbdb S/F Tp Mcb Db: Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 8 Way (4 + 24), Double Door |
| 140 | Mcbtpis S/F Tp Mcb Isolator: Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissoning Etc. As Required. 63 Amps |
| 141 | Mcbc S/F 'C' Curve, Sp Mcb Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole |
| 142 | Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc.With Charcoal/ Coke And Salt As Required.. |
| 143 | Earg125X6 S/L 25 Mm X 5 Mm G.I. Earth Strip In Ground: Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) |
| 144 | Supply Of Ac 230/250 Volts, 50 Hz Energy Efficient Ceiling Fan With Standard Down Rod, Blades, 3 Nos. Caps Model-Es 50 (1200 Mm Sweep) Etc. Complete In All Aspects As Per Direction Of Engineer In Charge 1200 Mm Sweep |
| 145 | Supply Of Ac 230/250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Etc. Complete . Model- Ventil Air - Ds (Make : Havells) 300 Mm Sweep 900 Rpm ,Complete In All 300 Mm Sweep 900 Rpm |
| 146 | Supply Of Led Glass Bulb B22, 15 W ,6000K /4000K/3000K ,230/250 Volt,50 Hz Etc, Complete In All Aspects As Per Direction Of Engineer In Charge. |
| 147 | Supply And Fixing Of Led Tube Light 1200Mm 20W 865 T8 Ip20 ,Lumen Output-1600 , 3000, 4000, 6500K Ceiling Mounted Led Batten (E-Lite Led Triyca) , Extruded Aluminium Heat Sink Provided For Efficient Heat Deissipation 7& Integrated Electronic Driver. ( 1X20 W Led Double 6500K) Complet In All Aspects As Per Direction Of Engineer In Charge. |
| 148 | Providing & Fixing Of Power Control Panel With All Its Accessories & Connections All Complete In All Respects As Per Direction Given By Engineer Incharge. |
| 149 | Supply, Installation, Testing And Commissioning Of Ongrid Solar Photovoltaic Power Plant Conforming To Mnre Specifications As Amended, Consisting Of Mono/Poly Crystalline Silicon Solar Cells, Net Metering Facility, Necessary Protections, Earthing, Mounted On Aluminium/Gi Structure Of Suitable Strength With Following Components Complete As Required:- A) Solar Photovoltaic Module Of Capacity 330 Wp Or Above, Manufactured In India, Conforming To Is 14286/Iec 61215, Is/Iec 61730-Part-1, Is/Iec 61730-Part-2. Solar Photovoltaic Module Conversion Efficiency Shall Not Be Less Than 16.5%. Pv Modules Used In Solar Power Plants/ Systems Must Be Warranted For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. B) Power Conditioning Unit (Pcu) Of 350-800 V Dc Input Voltage Range And 400 V Ac, Three Phase, 4 Wire, 50Hz +/- 2.5 Hz, Output Voltage Suitable To Generate Ac Power With Efficiency Not Less Than 97%, Total Harmonic Distortion Less Than 3% And Suitable For Ambient Temperature From 0 To 50 Degree C. The Pcu Shall Adjust The Voltage And Frequency Level To Suit The Grid Voltage Frequency. C) Data Monitoring System Complete With Accessories. D) Fixing Of Array Junction Box & Main Junction Box With Ip 65 Protection And Termination Arrangement For Incoming And Outgoing Cable Along With Glands, Lugs And Other Accessories Etc. As Required. E) Lightning And Surge Voltage Protection. F) Connections & Interconnections By Supplying & Fixing Required Size Xlpe Insulated Copper Conductor 1.1 Kv Grade Armoured Power And Control Cables Between Solar Modules, Main Power Cable To Grid Supply Pcu Unit Along With Supplying & Fixing Of Necessary Channel/Conduit Lugs And Other Accessories Etc. As Required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail