Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismentalling and removing RCC columns,beams,slab,staircase, landing, lintels including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete. |
| 2 | Dismentalling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete. |
| 3 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including rigid smooth centering, shuttering, cost, conveyance, taxes, royalities of all materials, watering, curing for 28 days cost of all mterials, labour and T&P required for the work etc complete as per the direction of Engineer-in-charge - Column in 2nd floor |
| 4 | Beam in 2nd floor |
| 5 | Lintel in 2nd floor |
| 6 | Roof slab in 2nd floor |
| 7 | Chajja in 2nd floor |
| 8 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge and cost and carriage of steel. etc. Complete as per the direction of Engineer-in-charge. |
| 9 | 2.5cm thick grading concrete of proportion (1:2:2) over roof slab using 6mm size hard black crusher broken granite chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect as per the direction of Engineer-in-charge. |
| 10 | Fly Ash Brick work with Fly Ash Bricks of 23cm.x 11cm.x 8cm. size having crushing strength not less than 75 Kg/Cm2 in cement mortar (1:6) in superstructure including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, taxes & royalties of all materials, labour with T&P etc. complete in all respect as per the direction of Engineer-in-charge. |
| 11 | 12mm thick Cement plaster in C.M.(1:6) over brick masonary to the smooth surface including watering, curing, cost, carriage, royalty and taxes of all materials, cost of all labour, T&P etc complete as per the direction of Engineer-in-charge. |
| 12 | 16mm thick Cement Plaster in C.M.(1:6) over brick masonary to the rough surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, T&P etc complete as per the direction of Engineer-in-charge. |
| 13 | 6mm thick cement plaster in cm (1:4) finished smooth to brick masonry including racking out joints including watering, curing, cost, conveyance, taxes, royalties, labour with T&P etc. complete in all respect. |
| 14 | Providing, fitting and fixing of false ceiling with aluminium anodised T section no.3215 with 2'-0\\" center to center, L section no. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C. plug and the aluminium grid 2'-0\\" x 2'-0\\" suspended from ceiling etc with cost, conveyance, taxes of all materials, labour, T&P etc. complete as per direction of Engineer in Charge. CSR2012/ Item 3 |
| 15 | Supplying of MS Grill/ Gate M.S windows and shutters to openings and collapsible gate of approved specification and approved quality with cost, conveyance, royalities and taxes of all materials, all labour and T&P required for the work etc complete in all respect and as per the direction of Engineer-in-charge. |
| 16 | Dressed seasoned sal wood work wrought & put up, framed and fixed in frames of doors, windows and beams, including cutting gruves, drilling holes, mending to size, etc. including cost of all materials & labour with T&P etc. complete in all respect. |
| 17 | 32mm thick Flush Door with all labour, iron fittings and wooden hinged cleats etc. fitted and fixed complete in all respect including cost of all fitting materials etc complete. |
| 18 | Supply and fitting, fixing of un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) sliding window with top fixed - 60 Series duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5 mm for outer frames, 75mmx60mmx2.25mm for casement Window Sash Profile and 74mmx 60mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using another fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per specification and direction of Engineer-in-Charge. |
| 19 | Supplying, fitting and Fixing of Vetrified tiles in floors, Trades of steps & Landing with with cement morter(1:4) with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect. |
| 20 | Supplying,fitting and fixing of Vitrified tiles in dados on 12mm thick cement plaster (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing ncluding cost, conveyance of all materials, labour and T&P etc. complete as per the direction of Engineer-in-charge. |
| 21 | Providing and fixing of plain 5mm thick ACP plate wall pabnelling by adjustable GI ceiling angle with spread at a distance not more than 600mm fixed to roof by rowl plug and stiff cleat, 5mm thick ACP plate held by G.I. Perimeter channel MF-3 and intermediate channel MF-7 framing, boarding, joinging and finishing etc including cost of all materials, labour and T&P etc complete. |
| 22 | Finishing wall surface with Acrylic wall putty of approved make & finished smooth & even surface to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour with T&P etc. complete in all floors. |
| 23 | Painting two coats with any approved plastic emulsion paint over a coat of putty and primer including cost of all materials, labour and T&P etc. Complete and as per the direction of Engineer-in-charge. |
| 24 | Wall painting two coats with weather coat of approved shade & approved make to give an even shade etc including cost of all materials, taxes & labour with T&P etc. complete in all floors as per the direction of Engineer-in-charge. |
| 25 | Painting two coats with any approved plastic emulsion paint over a coat of primer including cost of all materials, labour and T&P etc. Complete and as per the direction of Engineer-in-charge. |
| 26 | Mingle 46 strConference Table |
| 27 | ACE High Chair |
| 28 | Aero Mid Back Chair |
| 29 | Oxbo Visitor |
| 30 | Dustbin |
| 31 | E.I. Work: Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/ RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (Anti bacterial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, of suitable size, modular box with 1.5 sq. mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. - GROUP-B |
| 32 | GROUP-C |
| 33 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (Anti bacterial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 34 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) (Anti bacterial & flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 35 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS/MMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 36 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS/MMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 37 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS/MMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 38 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS/MMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 39 | Supply and drawing of following sizes PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in existing surface / recessed STEEL/PVC conduit as required.1X1.5 Sqmm |
| 40 | S/F of 20 amp 240 V SPN industrial type socket outlet with 2 pole and earth metal encloser plug top along with 20 amp \\"C\\" series SP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete connections, testing and commissionig etc. as required. |
| 41 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 42 | Sub-Head II (Light fitting Fixture & Fan) - Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 43 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 36W (595X595X70MM)and system lumens output not less than 4680 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . |
| 44 | BDBS,DB,AC DB,FLOOR PANELS,MCBS - Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. Supply and fixing of 16 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 45 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 46 | Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years. |
| 47 | (Earthing) INSTALLATION - Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 48 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 49 | CABLING AND END TERMINATION MAIN AREA - Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. - 4core x 16 sq mm |
| 50 | LAYING OF CABLE - Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 51 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. - 4 core x16 sq mm |
| 52 | S/F of 100AMP 25KA MCCB of Hager/Legrand/C&S Make with MS box including both side connections with all complete |
| 53 | Supply and fixing of copper bus bar with suitable sheet metal enclosure on MS angle frame with proper grouting on wall including all connections. - 100Amp TPN bus bar-300 X 32 X 3mm size |
| 54 | AIR CONDITIONER SPLIT - Supply of A,C with indoor and outdoor unit - Supply, installation , testing, commissioning of 2.0 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/Carrier) |
| 55 | REFRIGRANT PIPING - Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. - 1 TR to 3 TR high wall split A.C |
| 56 | FRAME WORK - Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. - 1 TR to 3 TR high wall split A.C |
| 57 | DRAIN PIPING - Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. - 25mm nom. Dia pipe |
| 58 | PRJOJECTOR SYSTEM - SITC of 55\\" UHD IPS Commercia Digita Display for small size discussion & Chambers:Brightness( 440 nits or higher),Dynamic contrast ratio(Dynamic MCI(Hz)):1000000:1,1000000:1,Static contrast ratio-1200:1,response time(G to G)-8msrefresh rate 60Hz,life span(Hrs)-30000,speaker sound output-10W+10W,SPEAKER SYSTEM:2.0 cH,DVB-t2/C Broad casting system,Commercial smart UX,WebOS VERSION(WEB 6.0),BIS Certification with 3 years onsite warranty.Make-sony/samsung/LG |
| 59 | Supply,installation,testing and commissioning of Sony4K Projector upto 2000 lumensof brightness,generateed by a long lastinglaser light source for vibrant images even on a large screen.all new native 4k SXRD Panel provides full 4k resolution withb 3840x2160 pixel.The powerfull video processor in the VPL-xw5000ES offers motionflow for smoth and clear motion even whwn viewing 4k content.The VPL-XW5000ES supports 4k 60 hz input with an input lag under 21ms and 2k 120 hz input with an input lag under 13 ms,.Acoustic noise 24 dB effective pixel 24,883,200(3840x2160x3) pixel.Projection lens shift-manual,vertical+/- 71%,Horizontal +/- 25%.(Make-Sony/Epson) |
| 60 | ELV Subhead- 1 (Lan System) - SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 61 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 62 | Supplying and fixing of following sizes of heavy class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak - 20 MM |
| 63 | 25 MM |
| 64 | P.H Work: Supplying all materials, labour, T&P and dismantling the old tiled flooring and removing the debris at a safe distance as per direction of the Engineer in charge.2nd floor |
| 65 | Supplying all materials, labour, T&P and dismantling old tiled cladding from walls and removing the debris at a safe distance as per direction of the Engineer in charge2nd floor |
| 66 | Supplying all materials, labour, T&P and dismantling the cement concrete flooring and removing the debris at a safe distance as per direction of the Engineer in charge |
| 67 | Supplying all materials, labour, T&P and dismantling the old lime or cement plaster from walls and removing the debris at a safe distance as per direction of the Engineer in charge.2nd floor |
| 68 | Supplying all materials, labour, T&P and dismantling the damaged European water closet or Anglo Indian water closet and removing the debris at a safe distance as per direction of the Engineer in charge - EWC, wash basin, orissa Pan, etc |
| 69 | Supplying all materials, labour, T&P and dismantling the damaged cp fittingsand removing the debris at a safe distance as per direction of the Engineer in charge - CP fittings |
| 70 | Supplying all materials, labour, T&P and dismantling the damaged B.E.glass mirrors,towel rails etc and removing the debris at a safe distance as per direction of the Engineer in charge - Mirror, Glass shelf, Towel rail, soap holder etc |
| 71 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking of the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge - Wooden Door |
| 72 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast) - 2nd Floor - 20mm Dia CPVC Pipe |
| 73 | 25mm Dia CPVC pipe |
| 74 | 32 mm dia PVC ASTM (Sch-80) pipe |
| 75 | 40mm dia PVC ASTM (Sch-80) pipe |
| 76 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm Thick Wall - 2nd Floor |
| 77 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. - in 2nd Floor |
| 78 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. - 2nd Floor |
| 79 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall |
| 80 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. |
| 81 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. - 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN |
| 82 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 83 | 15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 84 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 85 | 15mm dia CP Health faucet.ALD-CHR-579 |
| 86 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 87 | Shower Arm (SHA-CHR-477) |
| 88 | Over head shower 100mm dia round (OHS-CHR-1999) |
| 89 | 15mm dia CP Wall Mixture(Jaquar)CON-CHR-217KN |
| 90 | TOILET PAPER HOLDER-(Jaquar)-AGA-SSF-31751 |
| 91 | SOAP DISH-(Jaquar)-AGA-SAG-31731 |
| 92 | DOUBLE COAT HOOK(Jaquar)-ACN-ACR-1161 |
| 93 | CORNER GLASS SELF (WTH BRACKET)Jaquar-ACN-ACR-1173 |
| 94 | 25mm dia brass or gun metal full way valve(shakti make) |
| 95 | 32mm dia brass or gun metal full way valve(shakti make) |
| 96 | 40mm dia brass or gun metal full way valve(shakti make) |
| 97 | 15mm dia CP Flange |
| 98 | 15mm dia CP Extention Nipple |
| 99 | 125mm CP grating |
| 100 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) on the roof of 2nd floor |
| 101 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor - 110mm dia U-PVC SWR pipe (Supreme/Ashirvad/Oriplast) |
| 102 | 75 mm dia UPVC SWR Pipe (supreme/ashirvad) |
| 103 | 110mm U-PVC door tee |
| 104 | 110mm U-PVC Plain tee |
| 105 | 110mm U-PVC door bend |
| 106 | 110mm U-PVC plain bend |
| 107 | 110mm dia U-PVC 'P' trap |
| 108 | 110mm dia U-PVC Plain Shoe Bend |
| 109 | 110mm dia U-PVC offset with out ear |
| 110 | 110mm dia U-PVC cowl |
| 111 | 75 mm dia UPVC plain bend Pipe (Supreme/Ashirvad/Oriplast) |
| 112 | 76 mm dia UPVC plain Tee Pipe (supreme/ashirvad) |
| 113 | PVC clamp suitable for 75 mm to 110mm dia pipe |
| 114 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware / Nycer make) |
| 115 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 116 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hinware) |
| 117 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 118 | 15mm dia urinal spreader |
| 119 | 32mm dia C.P. dome waste |
| 120 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hinware) - Half Padestal wash hand basin(Make:JAQUAR/HINDWARE)Half pedestal basin FNS-WHT-40801 Wall Hung Basin with Fixing Accessories Size: 620x480x185 mm & FNS-WHT-40305Half pedestal with Fixing Accessoriesfor 40801 |
| 121 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 122 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N) |
| 123 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail (Jaquar) ACN-CHR-1111SM |
| 124 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 125 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make) |
| 126 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. - 2nd Floor;- |
| 127 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 2nd floor . |
| 128 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 400 x 400mm of size of Kajaria-Fogparla or equivalent make to be pre-approved In 2nd Floor |
| 129 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 450x300 of Kajaria-Durenmarfil or equivalemt make. - 2nd Floor;- |
| 130 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour brown/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. (Rajshri plastiwood/Alstone/Aramstrong or equivalent as per direction of Engineer-in-charge) |
| 131 | Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge (Rajshri plastiwood/Alstone/Aramstrong or equivalent as per direction of Engineer-in-charge) |
| 132 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 133 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 134 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 135 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 136 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 137 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. - 110mm dia U-PVC Alround Concrete |
| 138 | 160mm dia U-PVC Alround Concrete Please Enable Macros to View BoQ information |