| 1 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m (One point five metre) in width or 10 sqm (Ten square metre) on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m (One point five metre), including getting out the excavated soil and disposal of surplus excavated soils as directed, within any lead complete as per drawing and HP.PWD technical specifications and as directed by Engineer-Incharge including carriage of material within all leads, lifts and other incidentals. |
| 2 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level 1:4:8 (One Cement : Four coarse sand) : Eight graded stone aggregate 40 mm (Forty millimetres) nominal siz as directed by the Engineer-Incharge including carriage of materials within all leads, lifts and other incidentals. |
| 3 | Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in Foundation footings, bases of columns and mass concrete within all leads, lifts of materials and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge. |
| 4 | Providing form work with steel plates of 3.15mm (Three decimal one five millimetres) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimetres), so as to give a fair finish including centring, shuttering strutting and propping etcetera, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in columns, pillar, piers, abutments, post and struts including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design, specifications and as directed by the Engineer-in-charge. |
| 5 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) complete as per Architectural drawing, design and specifications and the like floor etcetera including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 6 | PProviding and laying cement concrete in retaining walls, return walls, walls (any thickness) including attachedpilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: with cement concrete 1:2:4 (One cement : Two sand : Four graded stone aggregate 20mm (Twenty millimeters) nominal size including carriae of material within all leads, lifts and other incidentals as per specifications, approved drawing, design, specifications and as directed by the Engineer-in-charge. |
| 7 | PProviding and laying cement concrete in retaining walls, return walls, walls (any thickness) including attachedpilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: with cement concrete 1:1.5:3 (One cement : one nad half : Three graded stone aggregate 20mm (Twenty millimeters) nominal size including carriae of material within all leads, lifts and other incidentals as per specifications, approved drawing, design, specifications and as directed by the Engineer-in-charge. |
| 8 | Providing Tor steel reinforcement of TATA/Sail/Tisco for reinforced cement concrete work including bending, binding, cutting, straightening and placing in position complete including cost of binding wires complete upto all floor levels as per specifications, approved drawing, design, as per entire satsfaction of the Engineer-in-charge including carriage of material within all leads, lifts and other incidentals. |
| 9 | Steel work welded in built up tubular (Round, square or rectangular hollow tubes etc; including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete and as per approved drawing, design including carriage of materials within all leads, lifts and other incidentals and as directed by the Engineer-in-Charge. |
| 10 | Providing and fixing 4mm (Four millimetre) thick ACP sheet cladding with necessary aluminium frame, cleats and shall be fixed to the masonary / RCC walls with necessary clamps, galvanised M.S. brackets and anchor fasteners and all joints of ACP shett must be sealed with approved sealent of approved colour complete as per the instruction of Engineer-Incharge (Base members of steel work shall be measured and paid separately) including fixing complete including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 11 | Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (One cement : Three coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade Granite stone of any colour and shade as per specifications, approved drawing, design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge including incidents. |
| 12 | Providing and fixing 300x16mm (Three hundred into Sixteen millimetres) nominal size aluminium sliding door bolts ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with nuts and screws etcetera complete, including carriage of material within all leads, lifts and other incidentals and as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 13 | Providing and fixing 250x16mm (Two hundred fifty into Sixteen millimetres) nominal size aluminium sliding door bolts ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with nuts and screws etcetera complete, including carriage of material within all leads, lifts and other incidentals and as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 14 | Providing and fixing 125mm (One hundred twenty five millimetres) nominal size aluminium Handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etcetera; complete including carriage of material within all leads, lifts and other incidentals and as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 15 | 15mm (Fifteen milimetres) thick cement plaster in single coat on fair/rough side of brick/concrete/stone walls for interior plastering upto all floor levels including arises internal rounded angles, chamfers and or rounded angles not exceeding 80mm (Eighty milimetres) in girth and finished even and smooth with cement mortar 1:6 (One cement: Six sand) including entire carriage of materials within all leads, lifts and other incidentals |
| 16 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre (Fifty grams per litre) and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives New work (Two or more coats applied @ 1.43 litre/ 10 sqm (One point four three litre per ten square metre) Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm (Zero point Nine zero litre per ten square metre) complete including carriage of material within all leads, lifts and other incidentals and further as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 17 | Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture including carriage of material within all leads, lifts and other incidentals and further as per HPPWD specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 18 | Providing and laying 60mm (Sixty millimetres) thick cement concrete paver block of M-40 (M-Forty) grade with approved color design and pattern factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge as directed by the Engineer-Incharge including carriage of materials within all leads, lifts and other incidentals. |
| 19 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering .Plain cement concrete 1:3:6 (One Cement : Three coarse sand : Ten graded stone aggregate 20 mm (Twenty millimetres) nominal size complete and as per HP.PWD specifications including entire carriage of materials within all leads and lifts and other incidentals. Please Enable Macros to View BoQ information |