| 1 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m (One point five metre) in width or 10 sqm (Ten square metre) on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m (One point five metre), including getting out the excavated soil and disposal of surplus excavated soils as directed, within a any lead as directed by the Engineer-in-charge, within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 2 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering .Plain cement concrete 1:4:8 (One Cement : Four coarse sand : Eight graded stone aggregate 40 mm (Forty millimetres) nominal size complete as per drawing and HP.PWD technical specifications and as directed by Engineer-Incharge including carriage of material within all leads, lifts and other incidentals. |
| 3 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth in cement mortar 1:6 (one cement isto six sand) and curing complete as per approved drawing, design and specifications and as per directions and entire satisfaction of the Engineer-in-Charge including carriage of material within all leads, lifts and other incidentals. |
| 4 | Supplying and filling in plinth with sand under floors including watering, ramming, consolidating and dressing completecomplete, ias directed by the Engineer-in-Charge including carriage of materials within all leads and lifts and other incidentals. |
| 5 | Providing Second class brick masonry using common burnt clay building bricks in super-structure upto all floor level in cement mortar 1:6 (One cement: Six sand) and curing complete including carriage of material within all leads, lifts and other incidentals as per approved specifications, drawing, design and as directed by the Engineer-in-charge. |
| 6 | Providing form work with steel plates of 3.15mm (Three decimal one five millimeters) thick, welded with angle iron in frames of 30x30x5mm (Thirty into Thirty into Five millimeters), so as to give a fair finish including centring, shuttering strutting and propping etcetera, with wooden battens and ballies for all heights/depths of propping and centring below supporting floor to ceiling and removal of the same for in-situ reinforced concrete and plain concrete work in flat surfaces such as soffits of suspended floors roofs, landings windows sills, cornices, arches, moulding, corbelling including curved surfaces where ever required as per Architectural drawing, design and specifications and the like floor etcetera including carriage of materials within all leads, lifts and other incidentals and as directed by the Engineer-Incharge. |
| 7 | Providing form work with steel plates of 3.15mm (Three decimal fifteen millimeters) thick, welded with angle iron in frames of 30x30x5mm(Thirty into Thirty into Five millimeters),so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights and removal of the same for in-situ reinforced plain concrete work in stairs cases with slopping or stepped soffits, excluding, landing, as per Architectural drawing and the like floor etc; complete ncluding carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge. |
| 8 | Providing form work with steel plates of 3.15mm (Three decimal fifteen millimeters) thick, welded with angle iron in frames of 30x30x5mm(Thirty into Thirty into Five millimeters),so as to give a fair finish including centring, shuttering strutting and propping etc, with wooden battens and ballies for all heights and removal of the same for in-situ reinforced plain concrete work in Edges of slabs and breaks in floors and walls under 20cm (Twety centimetre) wide complete including carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge. |
| 9 | Providing and laying in position machine batched and machine mixed cement concrete work of grade M-20 (M-Twenty) reinforced cement concrete work, using cement contents not less than @ 320 kg/cum (Three hundred twenty kilogram per cubic metre) or as per approved design mix for All works above plinth level to all floor level to give a smooth surfaces mechanically mixed and vibrated including curring complete and pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability complete including carriage of material within all leads, lifts and other incidentals as per approved drawing, design, specifications and as directed by the Engineer-in-charge. |
| 10 | Providing Tor steel reinforcement for reinforced cement concrete work including bending, binding, cutting, straightening and placing in position complete including cost of binding wires complete upto all floor levels as per specifications, approved drawing, design, as per entire satsfaction of the Engineer-in-charge including carriage of material within all leads, lifts and other incidentals. |
| 11 | Providing Sal wood work in frames of doors, windows, clerestory, windows and other frames wrought,framed and fixed in position complete as per specifications, approved drawing, design, as per entire satsfaction of the Engineer-in-charge including carriage of material within all leads, lifts and other incidentals. |
| 12 | Providing and fixing 40mm (Forty millimeters) thick second class Kail wood panelled, glazed or panelled and glazed shutters for doors, windows, clerestory windows etc. including black enameled/bright finished iron butt hinges with necessary screws etc complete and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to steel windows by welding complete including carriage of material within all leads, lifts and other incidentals, as per approved specifications drawing, design and as directed by the Engineer-in-charge. |
| 14 | Providing and fixing 40x3mm(Forty into Three milimetres)flat iron hold fast 40 cm(Forty centimeters) long including fixing to frame with 10mm(Ten milimetres) diameters bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm(Thirty into Ten into Fifteen milimetres) 1:3:6 (One cement: Three sand: Six graded crushed stone aggregate 20mm(Twenty milimetres) nominal size complete and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 15 | Providing and fixing 300x16mm size (Three hundred into sixteen milimetres) anodized aluminium sliding door bolts anodized transparent or dyed to required colour and shade with necessary screws etc. completed including entire carriage of materials as per directed by the Engineer-in-charge including entire carriage of materials within all leads, lifts and other incidentals. |
| 16 | Providing and fixing 200x10mm (Two hundred into Ten milimetres) nominal size aluminium Tower bolts (Barrel type) anodized transparent or dyed to required colour and shade with necessary screws etc; including entire carriage of materials as per directed by the Engineer-in-charge including entire carriage of materials within all leads, lifts and other incidentals. |
| 17 | Providing and fixing 150mm (One hundred fifty milimetres) nominal size aluminium handles anodized transparent or dyed to required colour and shade with necessary screws etc; and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 18 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc; complete and as directed by the Engineer- Incharge, including carriage of materials within all leads, lifts and other incidentals. |
| 19 | Providing and laying cement concrete flooring 40mm (Forty millimetre) thick with 20mm (Twenty millimetre) nominal size stone aggregate 1: 2:4 (One cement : Two coarse sand : Four graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 20 | Providing and fixing fan clamps of type-I or II of 16mm diameters M.S. barbent to shape with hooked ends to Reinforced Cement Concrete slab during laying including painting the exposed portion of loop all as per standard design complete as per specifications, drawing and design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 21 | 6mm (Six millimetres) thick cement plaster to ceiling in cement mortar 1:3 (One cement: Three sand) upto all floor levels complete including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 22 | 15mm (Fifteen millimetres) thick cement plasters in single coat on rough side of brick/concrete/stone walls for interior plastering upto all floor level including arrises, internal rounded angles, chamfers and rounded angles not exceeding 80mm (Eighty millimetres) in girth and finished even and smooth with cement mortar 1:6 (One cement: Six sand) above plinth level to floor all level complete including carriage of material with in all leads, lifts and other incidentals as per drawing, design and specifications, as per the direction and entire satisfaction of Engineer-in-Charge. |
| 23 | 15mm (Fifteen millimetres) thick cement plasters in single coat on fair side of brick/concrete/stone walls for interior plastering upto all floor level including arrises, internal rounded angles, chamfers and rounded angles not exceeding 80mm (Eighty millimetres) in girth and finished even and smooth with cement mortar r 1:4 (One cement : Four sand) including carriage of material within all leads, lifts and other incidentals, as per approved specifications drawing, design and as directed by the Engineer-in-charge. |
| 24 | Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works as per specifications, drawing and design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 25 | Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture as per specifications, drawing and design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 26 | Applying priming coat With ready mixed pink or grey of approved brand and manufacture on wood work as per specifications, drawing and design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 27 | Painting Wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture as per specifications, drawing and design including carriage of material within all leads, lifts and other incidentals and as directed by the Engineer-in-charge. |
| 28 | Providing and applying white cement based putty of Birla/J.K. avereage thickness 1mm (One millimetre0 of approved brand and manufacturer over the plastered wall surfaces to prepare the surface even and smooth complete and as per direction of Engineer- Incharge, including carriage of materials within all leads, lifts and other incidentals. |
| 29 | Finishing walls with 100% Premium/washable acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives complete New work (Two or more coats applied @ 1.43 litre/ 10 sqm (Zero point forty three liter / Ten square metre). Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm (Zero point ninety liter / Ten square metre) and directions of Engineer- in-charge and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (One cement : Three coarse sand (zone - III) : Six graded stone aggregate 20 mm (Twenty millimetre) nominal size over 75mm thick bed of dry brick ballast 40 mm (Forty millimetre) nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth and directions of Engineer- in-charge and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 31 | Providing and fixing 110mm (One hundred ten milimetres) nominal size on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes including necessary fitting the joints with approved adhesive complete and as directed by the Engineer-in-Charge including carriage of materials within all leads, lifts and other incidentals . |
| 32 | Providing and fixing 110mm (One hundred ten millimetres) diametre PVC Plain Bend on wall faces C.I. accessories for rain water pipes including filling the joints with approved adhesive complete including carriage of material within all leads, lifts and other incidentals and further as per specifications, approved drawing, design and as directed by the Engineer-in-charge. |
| 33 | Providing and fixing 110mm (One hundred ten millimetres) diametre P.V.C. Collar complete including carriage of material within all leads, lifts and other incidentals and further as per specifications, approved drawing, design and as directed by the Engineer-in-charge. Please Enable Macros to View BoQ information |