| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nanital patterns roof covering. complete all as specified and directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 4 | M&L for 100 mm thick cement concrete type D-2 1:4:8 (40mm graded aggregate) as in sub base to floor or for laying of floor finishes or similar works complete all as specified and directed. |
| 5 | M&L coloured chequered cement concrete tiles of size 300mm x 300mm x 20 mm, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors thick laid over and including 20 mm thick screed bed in CM 1:4 bedded and jointed in neat cement slurry complete all as specified and directed. |
| 6 | Racking out of sealing compound from existing joints of dimensions forming contraction/dummy/construction joints 15 to 25 mm wide including cleaning of edges and joint with brush and finally fanning with compressed air to make joints free from all loose material complete all as specified. The deteriorated edges of concrete joints shall be made good to true line with provisions of polymer concrete.Top 10 mm (minimum above back up rod), filled with polysulphide or polyurethane sealant and priming the sides with primer provision of closed cell polyethelene back up rod of suitable dia and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surface and to give a neat finishing to the sealant and removing the masking tape after sealant is applied complete all as specified and as directed by Engineer-in-charge. Make M/s Choksey Chemicals Pvt Ltd/FOSROC INDIA/ M/s Bostic India Pvt Ltd. |
| 7 | M&L for surface cleaning by mopping scrubbing, surface abrasion, removal of dust by vaccum cleaner complete all as specified and directed by Engineer-in-charge |
| 8 | M&L for priming a coat of mix of resin & handner (in 2:1 ratio by volume) of thickness not less than 200 micron @ 5 Sqm/Ltr (below Screeding for epoxy Coating) which penetrate into concrete to form a adhesive bond using stiff crush or roller complete all as per manufacturers instructions and directed by engineer -in-charge |
| 9 | M&L for 4 mm thick screeding by milled trowelled system with mortar of material specially treated aggregate in resin matrix For maximum strength protection complete all as per manufacturer's instructions and directed by Engineer-in-charge |
| 10 | M&L for 0.8 mm thick chemical resistant coloured pure epoxy self levelling topping low viscous, free flowing composition applied by trowel or sqeege,decorated by spike roller to dislodge air bubbles complete all as per manufacturer's instructions and directed by Engineer-in-charge |
| 11 | M&L for applying 500 micron thick self levelling top coat as mix of Resi, Hardner, Filler and Pigment in ratio of 1.0:0.6:1.85:0.1 by weightile 4.79 kg Resin base 2.83 kg Hardner: 8.88 kg Filler: 0.5 kg Pigment). The mixing to be done correctly homogeneous with an electric variable speed mixer. The layer to be de aerated by spike roller to dislodge air pockets as in desired shade complete all as per manufacturer's instructions and directed by Engineer-in-Charge |
| 12 | M&L for floor patch repair by floorcreteja mis of 20 kg content resin hardner and aggregates) complete all as manufacturer's instructions and directed by Engineer-in-charge. (A mix of 20 kg floorcrere will cover 1 sqm arra having 10 mm Thickness) |
| 13 | M&L for surface preparation and polyurethane based two component yellow/white marking for demarkation over &including a coat of epoxy resin based primer complete all as specified & directed by Engineer-in-charge. |
| 14 | Dismantling structural steel work including doors, gates but excluding framedtruss etc. complete all as specified and directed |
| 15 | Supply and fabrication, Erection and commissioning at site. Eraction of iron frame for second rail and commissioning , Sliding Hanger door with clear span of 18.0 mtr (Tolerance+-05%) consisting of total 8 Nos leaves size of each leaf (2.10 mtr x 4.30 mtr ht), four sliding on left side and four sliding right side of the hangar door opening on two rails (Tolerance+-5%) and fixed in existing hangar located at site without damaging the existing structure. Total opening to be divided in equal panels in 08 Nos in longitudinally and panels set to be opening on either side of the bay.SPECIFICATIONS:-(a) Hangar door frame structure including tracks/rails, top tracks, will be used as per designed and structural steel with suitable UB/ISMB/ISMC, RHS and CHS member conforming to relevant IS Code and design as per IS-800-2007 with standard worst combination of different type of load as per IS code applicable to site. The design shall include the coln end supports of suitable steel member on both side of the opening to support the top tracks/rails. The gate shall have cladding of puff material of 40mm thickness with 0.50mm thick PPGI sheet (one side Green colour) with micro ribs (make -JSW) (RAL-9002) both sides with PUFF Density 44Kg/m3+-10% in metalic tongue. complete all specified and directed.(b) Gurante - Door structure 10 Years.(c) The contractor shall stand guarantee to the government for a period of 10 years from the certified date of completion of work. The contractor shall furnish a written statement for the effectiveness of Hangar door structure for a period of ten years in favour of GE. The amount of security deposit against the guarantee of Hangar door structure calculated as per scale laid down for calculation individual security deposit on the amount of Hangar door structure at contract rates, rounded off to next rupees or Rs 50,000.00, whichever is more. |
| 16 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in foundation etc, complete all as specified & directed |
| 17 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc. |
| 18 | Taking down DBs along with MCBs and connected accessories of any size and make. |
| 19 | Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm incl 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earth wire ( green in clour) and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with CI/MS/PVC sunken boxes of size as required at site along with plastic laminated hylom sheet cover 3 mm thick for fixing swiches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - |
| 20 | One light point/ one fan point/ Bell Point controlled by one switch |
| 21 | One 3 pin socket outlet, 5 Amp independent |
| 22 | One 3 in socket outlet 5 Amps on same board |
| 23 | Supply and fix switch piano flush type 5 Amps all as specified and directed . |
| 24 | Supply and fix socket 5 amp flush type complete all as specified and directed . |
| 25 | S & Fix Ceiling rose 3 terminal flush type 6 Amps,250 volts AC ISI marked |
| 26 | S&F batten holder 230 volt all as specified and directed . |
| 27 | M&L for LED bulb 15 watts complete all as specified and directed. |
| 28 | All as per item No 28 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith along with CI/MS/PVC sunken boxes of size as required at site along with plastic laminated hylom sheet cover 3 mm thick for fixing swiches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc along with one run of 2.5 sqmm cable as earth wire ( green in colour ) and connected to common earth all as specified. |
| 29 | S & F socket 5 pin 16 /6 Amp flush type complete all as specified and directed. |
| 30 | S & F switch 15/16 Amps complete all as specified and directed. |
| 31 | S&F decorative ultra slim polycarbonate LED 4 feet long 20/22 watts with THD less than 15% very high efficiency suited for T-8 tube luminare with system efficacy 110 lumen per watts , high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. . |
| 32 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 33 | S&F in replace warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed. |
| 34 | Taking down old u/s submain wiring of any sizes complete incl conduits/PVC casing n caping all as specified & directed. |
| 35 | M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.Note :1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .2. Proper colour coding shall be maintained as per IS code. |
| 36 | M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 1.5 Sqmm drawn through in and including Non metalic PVC heavy duty PVC conduit of suitable size as required at site with all accessories with one run of 1.5 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.( for building lights and aviation obstruction lights)Note :1. Two run of main copper conductor 1.5 sqmm size , one run of 1.5 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .2. Proper colour coding shall be maintained as per IS code. |
| 37 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. (for inside and outer side) |
| 38 | S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 06 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 415 volts, flush to wall / fixed on surface complete incl making good all as specified and directed. |
| 39 | S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 08 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete incl making good all as specified and directed. |
| 40 | S&F MCB TPN 40 To 100 AMP Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one |
| 41 | S&F MCB SPN 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one |
| 42 | S&F MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capaity complete all as specified and directed incl taking down old one |
| 43 | Supply and fix single pointed aluminium rod 12 mm dia and 300 mm long fixed on the roof with all fittings, fixtures complete all as specified and directed. |
| 44 | Supply and fix aluminium strip 25 X 3 mm with saddles and fixing screws etc for roof and down conductors above ground level all as specified. |
| 45 | M/L for GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit. |
| 46 | M&L Earth Test point terminal block made of gun metal or phosphorus bronze size 75X75X25 mm of 6 mm thickness or copper stip of 32X6 mm, 100 mm long, drilled and secured including 4 Nos 8mm dia, 25mm long hexagonal head brass screws including box of size 90X90X90 mm made of 1.6 mm plain steel sheet painted with two coats of synthetic enamel paint over a coat of red oxide primer and secured to wall for protection of test point complete as specified. |
| 47 | M&L GI Pipe light Grade of size 25 mm dia incl fittings and fixtures complete to wal ceiling/roof complete incl incl base plate for fixing on Galvalume sheet with proper fixing arrangements , nut , bolt washers incl necessary welding work all as specified and directed. |
| 48 | M&L Earthing complete with galvanised steel earth plate electrode size 600x600x6.00mm thick burried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by GI protection pipe light grade 40mm bore with all fittings from upper edge of earth plate to body of equipments fixed with and including 25x4mm FI clamps and also including provision of GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix)cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.3 of SSR Part-I(2009), connecting to earthing test point all as specified & as directed including testing on completion. ( for DB earthing and LA earthing) |
| 49 | Deduct Credit for Demolished/Dismantled material Rs (-) 2,58,572.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |