| 1 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance complete all as directed by the Engr-in-Charge |
| 2 | M & L for 40 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish complete all as specified and directed. |
| 4 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 5 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 6 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/ snap grid frame etc complete all as specified and directed. |
| 7 | S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer's instructions including 4 mm thick non asbestos E-board, HSPC, designer fixed to frame complete all as specified and directed by the Engr-in-Charge. |
| 8 | S & F in repair 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 9 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 10 | Demolition of brick work or stone / boulder masonry, concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish complete as directed by the Engr-in-Charge. |
| 11 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and including setting in mortar 1:4 complete all as specified and directed. |
| 12 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of 10cm thick, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) n exc. 10 cm in width and including setting in mortar 1:4 complete all as specified and directed. |
| 13 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 14 | M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. |
| 15 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 16 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of oil emulsion distemper over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. |
| 17 | M & L for Glazed, ceramic, coloured tiles of size 450mm x 350mm x 7mm thick, on vertical surfaces such as skirting, dados etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 10 mm thick bedding in cement mortor 1:4 complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and disposal of debris and rubbish to a distance complete all as directed by the Engr-in-Charge |
| 19 | M & L for Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 20 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 21 | M & L for use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 22 | M & L green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed. |
| 23 | S & F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position and including 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and directed. |
| 24 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 25 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 26 | S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm). |
| 27 | S & F Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings such as peg stay 150mm long (01 No), hinge type B-21, 100mm long (02 Nos) and suitable size of handle complete all as specified and directed. |
| 28 | S & F 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed. |
| 29 | S & F 35 mm thick, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 30 | S & F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc Fe-290 (Gde E165) complete all as specified and directed. |
| 31 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 32 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. |
| 33 | S & F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 35 | S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. Please Enable Macros to View BoQ information |