| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 2 | Dismantling of timber scantling under 40sqcm in section, as in any position, complete all as specified and directed. |
| 3 | Taking down chowkhats or frames exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified and directed. |
| 4 | Taking down chowkhats or frames n.exc 1.5 Sqm (without taking off shutters from frame) complete all as specified and directed. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 7 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 8 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 9 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 10 | Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 11 | Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed. |
| 12 | Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. |
| 13 | 15mm thick rendering in CM 1:6 on stone masonry surfaces or other than fair face of brickwork or on one side of lathing finishing the surface even and smooth without using extra cement, complete all as specified and directed. |
| 14 | Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 ltr/10 sqm over new surfaces in painting on walls in camouflage pattern with combination of minimum five colours as approved by GE complete all as specified and as directed. |
| 15 | Complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 ltr/10 sqm over old surfaces in painting on walls in camouflage pattern with combination of minimum five colours as approved by GE complete all as specified and as directed. |
| 16 | Preparation of new plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 17 | Complete removal of existing treatment and preparing the surfaces of walls and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 18 | 75mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 19 | 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and directed |
| 20 | Vitrified ceramic light shade tiles 8-10 mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 21 | Vitrified ceramic light shade tiles 8-10 mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36sqm on vertical surfaces as in dado/skirting and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,laid over and including 10mm thick screed bed in CM 1:3 complete all as specified and directed. |
| 22 | Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 23 | Glazed ceramic coloured tiles 350x250x7mm /450mmx350mm x7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick back coat layer in cement mortar 1:3, complete all as specified and directed by Engr-In-Charge. |
| 24 | 20mm thick granite (of approved type /colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking plateform,steps, laid over and including 20mm thick cementmortar 1:4 and jointed with grey cement slurry and pointed with white cement 1:2 with admixture of pigment to match the colour of granite stone including cutting and moulding the edges, complete all as specified. |
| 25 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring to receive floor finishes, complete all as specified and directed. |
| 26 | Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed in white or coloured cement mixed with pigments to match with the colour of tiles, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed |
| 27 | 15mm brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe fixed in repair, complete all as specified and directed. |
| 28 | Soap dish of matt chrome finish fixed with chromium plated brass screws and wooden/plastic plugs etc fixed in repairs,complete all as specified and directed. |
| 29 | Supply & fixing in repairs Toilet paper holder of stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed |
| 30 | Supply and fixing in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 31 | Bib taps 15mm bore of cast copper alloy chromium plated ,fancy type, screwed down, high presure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule, fixed in repairs, complete all as specified and directed. |
| 32 | S&F in repairs 15mm bore Stop valve/angle cock, cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified. |
| 33 | Vitreous china Wash hand basin, white, flat back of size 550x400mm excluding waste chain, porcelain stopper but including brackets, brass chromium plated waste coupling, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc fixed in repair, complete all as specified. |
| 34 | PVC connection 15mm size with CP nuts on both ends of length 600mm fixed in repairs, complete all as specified and directed. |
| 35 | PVC connection 15mm size with PTMT nuts on both ends of length 600mm fixed in repairs, complete all as specified and directed. |
| 36 | Grating doom 100 mm dia with waste hole of PTMT. (Minimum weight 40gms), fixed in repairs, compelte all as specified and directed. |
| 37 | Supply and fixed in repairs vitreous china premium/1st quality wash down water closet wall hung type, EWC white/ivory/off white ,closed pattern incl all necessary accessories like rag bolts/gel gasket etc. incl 10 litres vitreous china valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including pipe & brackets complete in all respect, including jointing to existing pipe of floor of size 100mm, complete all as specified and directed. |
| 38 | 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 40 | Supply and fixing in repairs, Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flushpipe and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified. |
| 41 | 20mm dia Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed for urinal complete all as specified and directed. |
| 42 | Rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top), ISI marked hoisted and fixed in position all as spd in SSR Pt-I, of capacity 500 Ltrs including making necessary connection and fittings, dismantling existing tank and removing from site, complete all as specified and as directed. |
| 43 | Rotational moulded polyethylene water storage tanks triple layer (Cylindrical vertical with closed top), ISI marked hoisted and fixed in position all as spd in SSR Pt-I, of capacity 1000 Ltrs including making necessary connection and fittings, dismantling existing tank and removing from site, complete all as specified and as directed. |
| 44 | 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed complete all as specified and directed. |
| 45 | Steel water tubing 15mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, incl taking down old unsv tubing and removal to store complete all as specified and directed. |
| 46 | Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, incl taking down old unsv tubing and removal to store complete all as specified and directed. |
| 47 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar if required any dia complete all as specified and directed. |
| 48 | PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified and directed. |
| 49 | PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint, laid in floor, fixed in repair, complete all as specified and directed. |
| 50 | PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint, laid in floors, fixed in repair, complete all as specified and directed. |
| 51 | PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint, fixed to walls, fixed in repair, complete all as specified and directed. |
| 52 | PVC (SWR) bends any radius 75mm bore fixed, complete all as specified and directed. |
| 53 | PVC (SWR) bends any radius 110mm bore fixed, complete all as specified and directed. |
| 54 | PVC (SWR) vent cowl 75mm dia fixed in repair, complete all as specified and directed. |
| 55 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 56 | Walling of random rubble stone masonry, brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed. |
| 57 | Walling of random rubble stone masonry, brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6),but except stone complete all as specified and directed. |
| 58 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and directed |
| 59 | Anodised aluminium frame powder coated of any colour (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed. |
| 60 | Anodised aluminium powder coating of any colour (thickness or powder coating not less than 50 micron) , door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised alumnium snap beading screws etc complete all as specified and directed. |
| 61 | Anodised aluminium powder coating of any colour ( minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 62 | Anodised aluminium powder coating of any colour ( minimum thickness of powder coating 50 micron) work for partitions (fixed portions), aluminium sections weighing 0.55 kg/m with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make fixing with dash fasteners of required dia and size , including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling, CP brass/stainless steel screws, including 5.50mm thick sheet glass and 6mm thick PVC sheet as per site requirement complete all as specified and directed by E-in-C. |
| 63 | Anodised aluminium powder coating of any colour ( minimum thickness of powder coating 50 micron) grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel complete all as specified and directed. |
| 64 | Sheet glass 5.5 mm thick ordinary quality and glazing solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers exc 0.5 sqm in each ,fixed in each door and window , complete all as specified and directed. |
| 65 | 6mm thick plain colour PVC sheet fixed to aluminium doors at site as per manufacturer instructions complete all as specified and as directed. |
| 66 | 4mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 67 | 3mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 68 | Supply and fixing in repair 4mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 69 | Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete as specified and directed. |
| 70 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete as specified and directed. |
| 71 | Preparation of new or previously untreated steel or iron surfaces exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 72 | Preparation of old or previously untreated steel or iron surfaces exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 73 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 74 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 75 | Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified and directed. |
| 76 | 100 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 77 | 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 78 | 100 mm long aluminium handles, cast type anodised and fixed complete all as specified and directed. |
| 79 | 150 mm long aluminium handles, cast type anodised and fixed complete all as specified and directed. |
| 80 | 200 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed |
| 81 | 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed |
| 82 | Dismantling wall/ceiling board (fibre, pulp, insulation, etc) or insulation board, slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed. |
| 83 | Anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and as directed. |
| 84 | Suspended false ceiling using E-grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38x24mm sheet thickness 0.4mm, cross Tee 28x24mm sheet thickness 0.3mm and wall angle 24x24x3mm using 6mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS no 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips including preparation of surfaces and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and directed. Make:- Everest Industries Ltd or equivalent |
| 85 | Hollow PVC wall lining consisting of 5mm thick but wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 86 | Exposed metal frame ceiling grid made of galvanised iron as per specification and drawing with hollow PVC ceiling consisting of 5-6mm thick but wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site complete all as specified and directed. |
| 87 | 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on walls to make PVC frame as per specification and drawing complete all as specified and directed. |
| 88 | Demolition of existing soakage well and septic tank of any type |
| 89 | Construction of on site LLDPE septic tank designed to carry sewage and sullage water, exc in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connections etc complete for 10 users complete all as specified and directed. |
| 90 | Construction of soakage well 1.80 mtr dia and 3.00 effective depth type D-2 (using 40mm graded crushed stone aggregate) in foundation, wall in honey combed brick work in CM 1:4 , cover slab of M-25 (Design mix), filling with brick bed, earth cushion on brick lining top and inlet pipe 150mm dia, complete all as shown on drawing no. CE/TD-1202/2003 sheet 1/2 and 2/2 amended up to date as directed. |
| 91 | Excavation in trenches for sewer lines and manholes not exc 10 sqm on plan and not exc 1.5m deep in any type of soil including demolition of exisiting sewer line complete all as specified and directed. |
| 92 | Excavation in trenches not exc 10 sqm on plan and not exc 1.5m deep for laying of cables in any type of soil complete all as specified and directed. |
| 93 | Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each,complete all as specified and directed at site. |
| 94 | Removing excavated material/surplus soil to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed. |
| 95 | Concrete bed to drain pipes 150mm dia laid in trenches including packing under and haunching against the side of pipes, after they are laid and tested in PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate), complete all as specified and directed complete. |
| 96 | Reinforced concrete pipes, 150 mm dia class NP2 , laid and jointed complete with collars all as specified. |
| 97 | PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 98 | Rendering 15mm thick in cement mortar 1:4 on stone masonary or other than fair face of brick masonary surface finished even and smooth without using extra cement including mixing of water proofing compund as per manufacturer's instruction ( water prooofing compound shall be measured and paid seperately), complete all as specified and directed. |
| 99 | Supply only liquid water proofing compound @ 0.20 ltr per 50 kg of cement or as per manufacturer's instructions, complete all as specified and directed. |
| 100 | PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, bed plates benching etc slightly rounded or chamferred angles and throating, complete all as specified and directed. |
| 101 | TMT bars, 6 to 8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified. |
| 102 | Precast reinforced cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in manhole cover slab, complete all as specified and directed. Note:- Reinforcement shall be measured and paid seperately |
| 103 | Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 104 | Machine cut Kota stone slab 18-20mm thick as in riser of steps, skirting, dado and pillar laid over & including screed bed 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the kota stone including rubbing and polishing, complete all as specified and directed. |
| 105 | 20mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and directed |
| 106 | Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore complete all as specified and directed. |
| 107 | S&F fixing in repairs squatting pan of size 580 x 440 mm white, with integral foot rests including connection to trap, flushing cistern and flushing pipe, anti-syphonage pipe, etc. complete including 110 mm dia PVC (SWR) 'S' trap including lime concrete bedding and jointing to existing pipe of floor of size 100mm complete all as specified and as directed. |
| 108 | Supply & fixed in repair, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle (incl brackets & flush pipe PVC 32 mm dia) capacity of 10 Litres complete all as specified. |
| 109 | Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed. |
| 110 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 (Gde-E-165), complete all as specified and directed. |
| 111 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed. |
| 112 | 35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed. |
| 113 | 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR PART I section 8, clause 8.24 (a), kiln seasoned and chemically pressure treated , supplied & fitted to chowkats complete all as specified and directed. |
| 114 | Preparation of wood and wood based surfaces of over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 115 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 116 | Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 117 | Box type steel windows/ventilaotrs irrespective of whatever is shown on drgs,steel window/ventilators shall be box type conforming to IS-1038 and shall be IS marked manufactured by any ISI approved maufacturer whose list can be seen on website www.bis.org.in pertaining to IS-1038. Alongwith the paid voucher, contractor will submit attested copy of valid license, certificate of manufacturer to authenticate that ISI marked windows are supplies by ISI approved manufacturer. Rolled steel sections used shall also be ISI marked. Makes given in appx of makes attached here-in-after for steel windows/ventilators, shall be applicable only if they fulfill the criteria mentioned here-in-before. |
| 118 | E/M PORTION:- Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose, celing fan etc and making good to disturbed surfaces of wall, floor etc to match with existing finishes complete all as specified and directed. |
| 119 | Point wiring with 2x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and 1x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of approporiate size and all requisite accessories such as PVC elbow, Tee, collars, bends etc with PVC terminals box & cover for mounting switches, sockets, fan regulator etc complete all as specified and as directed for the following:- |
| 120 | One light/fan point controlled by one switch |
| 121 | One 5 Pin, 6 amp socket outlet on same board |
| 122 | One 5 Pin, 6 amp socket outlet on independent board |
| 123 | All as per item No. 119 above but with two 2.5 sqmm size cable as phase and neutral and one 2.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board |
| 124 | Ceiling rose, 3 phase,bakelite 65x50mm two or three therminals complete all as specified and directed. |
| 125 | Piano Type switch , 1 way, 6 amp, flush type complete all as specified and directed. |
| 126 | Socket outlet 2 in 1, 5 pin 6 Amps, flush type complete all as specified and directed. |
| 127 | Switch socket combination 2 in 1 , 5 pin 6 Amp, flush type complete all as specified and directed. |
| 128 | Switch socket combination 2 in 1 , 3 pin 6 and 16 Amp, flush type universal complete all as specified and directed. |
| 129 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 130 | Invert Led Lamp , CDL 12 Watt , B22 base all as specified and as directed. |
| 131 | Supply and fix in repairs Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed. |
| 132 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 133 | Supply and fixing in replacement LED lights fitting 1x 20W, 230V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 134 | S&F in repair ceiling mounted LED light fittings luminaire 600mmx600mm,35/36 watt, 220 v, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and directed. |
| 135 | Supply and fixing in repair building security light fittings, 35 watt LED,230v, AC out door type pre-wired, IP-65/66 protection, with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket complete all as specified and directed. |
| 136 | M&L in repair incl taking out old unsv ceiling fan from site of capacity 1200/1400 mm sweep and replacement with and incl new BLDC ceiling fan of 1200 mm sweep, 230 V, 50 hz incl all connecting accessories complete all as directed by engineer-in-charge. |
| 137 | S&F in repair vertical TPN DB sheet metal enclosure double door (IP-43) , 4 ways, built in bus bars complete suitable for 415 volts, AC, 50 HZ complete and as directed. Make : L&T/Legrand/Standard/havells. |
| 138 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 139 | Supply and Fixing in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 20 Amps MCB SP complete as specified and directed |
| 140 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm incl all connecting accessories and taking down old unsv exhaust fan from site and keeping it in store complete all as specified and directed. |
| 141 | Supply and fixing in repairs MCBs, TPN, 415 volts, breaking capacity 10 KA, rating 20-100 amps, complete all as specified and directed. |
| 142 | Supply and Fixing in repair MCBs, SPN, 240 volts, breaking capacity 10 KA, 'C' series, rating 40-63 amps, complete all as specified and as directed. |
| 143 | Supply and Fixing in repair MCB, SP,240 volts, breaking capacity 10 KA, 'C' series, rating 6 to 32 amps, complete all as specified and as directed. |
| 144 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed. |
| 145 | Sub main wiring with single core cable 2 x 6 sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade drawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling, alongwith 1x4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of 6sqmm cable alongwith one run of 4sqmm PVC insulated copper conductor as earh wire incl casing caping shall be measured as one unit. |
| 146 | Supply laying jointing in trenches/ floors/pole or under road/culvert and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed. |
| 147 | Supply and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 40 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed. |
| 148 | 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed inservice connections suspended by insulating hangers notmore than 1 metre apartincluding4mm suspension wire, one twin core cable flat or circular of area 16 sqmm 2 core incl taking down old u/s cable ,complete all as specified and directed. |
| 149 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 12 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail