| 1 | Dismantling of asbestos cement (corrugated, semi-corrugated etc) sheets in roof covering complete all as specified and directed. |
| 2 | S&F in repair Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screw (Heavy duty) with in built washers and neoprene & EDPM washers, in roofs, walls etc complete all as specified and directed. |
| 3 | S&F in repair pre painted galvalume aluminium zinc coating GI based plain steel sheet .50 mm thick of an colour having tensile strength of 550 mpa as in ridges ,Eaves,hips,valley gutter,drip or straight fastening etc fixed with self tapping(Heavy duty)with in built washers and neoprene &EDPM washers screw etc complete all as specified and directed. |
| 4 | Demolation of wall and ceiling boards ( Fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets any thickness, including cover fillets complete all as specified and directed. |
| 5 | Providing and fixing false ceiling in repair of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M&L for joint free coloured ceramic tiles 7 to 8 mm thick, area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15mm thk for laying floor finishes of cement mortar 1:6 complete all as specified and directed. |
| 8 | M&L for Glazed ceramic tiles in vertical surfaces of size 300 x 200 x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surface including 15 mm thk backing coat in cement mortar 1:4 including taking down the existing complete all as specified and directed. |
| 9 | M&L for 20 mm thk granite (of any type) work (table rubbed and polished) in steps,jambs,pillars,window cills , cooking platform and like in cement mortar (1:4) incuding pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm thk screed bed in cement mortar 1:4 complete all as specified and directed. |
| 10 | S&F for powder coated aluminium sliding windows two track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directed. (A) FRAME:-(i) Top and side member for two track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS.(ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalent as specified in PS. |
| 11 | (C) Sliding shutter to be provided with 5.5 mm thick sheet glass complete all as specified and directed.(D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium 'U' channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii) Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm. (E) Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat complete all as specified and as directed. |
| 12 | M&L for aluminium ventilator frames with frame of section 100mm x 44 mm of thickness 1.6 mm shutters of section 32 mm x 15mm (with and including half portion fixed glazed shutter and rest half portion louvered with glazed shutter) including stainless steel wire mesh, rubber gasket for securing the glass, 5.5 mm thick figured glass, aluminium grill and necessary aluminium mongaries and handles including necessary locking arrangment complete all as specified and directed. |
| 13 | Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 14 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm each including removing to store complete all as specified and directed. |
| 15 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters without taking off shutters from the frame complete all as specified and directed. |
| 16 | Taking down and refixing in the same opening ,resecuring or easing &adjusting of shutters exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed. |
| 17 | Taking down chowkhats or frames n.exc 1.5 Sqm each including removal to store complete all as specified and directed. |
| 18 | Taking down shutters of any description n.exc 1 sqm each and resecuring or easing or adjusting and refixing in other opening complete all as specified and directed. |
| 19 | S&F for Fe-410-W(Gde-E-250)quality B for fabrication framed work as in door or gates of angle or other section with gusset plate .rails, braces ,etc complete drilled for fixing of steel sheeting or other covering , Doors ,etc, to be prepared for hanging or sliding with and including either fooks and hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering rumming rails and guides)hanging ,also fastening and fixing complete all as specified and directed. |
| 20 | S&F for Fe-410-W(Gde-E-250)quality B joist, channel, angle or tee sections, fixed independently, with out connecting plates etc (cut to ordinary lengths i.e with in 20 mm of length indicated) complete all as specified and directed. |
| 21 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 22 | S&F in repair Solid PVC door frame of size 50mm x 47mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 23 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed. |
| 24 | S&F for pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges including welding, lock strike plates,etc and including back filling with PCC 1:2:4 type B-0( using 12.5 mm graded aggregate) complete all as specified and directed. |
| 25 | S&F for pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges,lock strike plates,etcand including back filling with PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) complete all as specified and directed. |
| 26 | Cutting holes in brick walls of depth exc half brick but n.exc one brick, built in cement mortar or cement lime mortar and stone walls built In lime mortar for inserting holdfast and making good dismantling portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. |
| 27 | S&F in repair Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 28 | S&F in repair 35mm thick 2nd class HW factory made plain, framed, panelled shutter (two panel) with lock rail and panels of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 29 | S&F in repair 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, as in cupboard shelves /door shutters, etc complete all as specifed. Including taking down existing complete all as specified and directed. |
| 30 | S&F for 2nd Class HW glazed and skeleton shutter 35 mm thick, open rebated & prepared to receive glass, gauze, etc. (rebated sash bars) edges of framing plain, chamfered or rounded fittted with cut and mitred beads for securing glass etc size of members of shutters as specifed in SSR Part I, Section 8 clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and directed. |
| 31 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates, hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts, clamps, hold fasts, wall ties; hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 32 | M&L for plywood 18 mm thk ,veneered decorative plywood ,grade 1 (with BWR resin)with decorative face veneers on both faces fixed with screws to timber frame work complete all as specified and directed. |
| 33 | M&L for 2 coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer over 10cm width or girth including preparation of new surfaces complete all as specified and directed. |
| 34 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 35 | M&L for providing PCC 1:3:6 tupe C-1 (using 20 mm stone aggregate), in ( cement mortar 1:4 ) lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, as directed complete all as specified and directed. |
| 36 | S&F in repair Aluminium, anodised, barrel tower bolts of extruded section of 150 mm long complete all as specified and directed. |
| 37 | S & F in repair 150mm aluminum anodised cast type bow handles complete all as specified and directed. |
| 38 | S&F in repair 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 39 | S&F in repair 100mm butt hinges, medium weight, cold rolled mild steel, and fixed complete with screws/welding to pressed steel frame complete all as specified and directed. |
| 40 | S&F in repair 75mm butt hinges, medium weight, cold rolled mild steel, and fixed complete with screws/welding to pressed steel frame complete all as specified and directed. |
| 41 | Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed. |
| 42 | M&L for Painting to new steel Surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxide, not otherwise described complete all as specified and directed. |
| 43 | M&L for Taking down of cement plaster of any description and in any postion including racking out joints for key scrubing with water etc complete all as specified and directed. |
| 44 | M&L for (10+5)15mm thick rendering in cement mortar (1:4) in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed. |
| 45 | Supply only integral water proofing compound complete all as specified and directed. |
| 46 | M&L for rendering 10mm thick in cement mortar (1:6) on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 47 | M&L for 5 mm thick rendering in cement mortar (1:3) on fair faces of concrete surfaces such as soffits of slabs, ceiling etc in patches n.exc 1 Sqm each finishing the surfaces fair and even complete all as specified and directed. |
| 48 | M&L for complete removal of existing treatment of plastered surfaces of ceiling and applying three coats of white wash including preparation of old surafaces complete all as specified and directed. |
| 49 | M&L for preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying two coat of distemper oil emulsion over one coat of wall care putty incl complete removal of existing treatment complete all as specified and directed. |
| 50 | M&L for preparing new surfaces and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over chalk whitening, on plastered surfaces to internal walls complete all as specified and directed. |
| 51 | M&L for Preparing old plaster surfaces (external face) of walls and applying one coat of all weather cement based paint complete all as specified and directed. |
| 52 | M&L for Preparing newly plaster surfaces(external face) of walls and applying one coat cement based paint over a coat of alkali resistance primer complete all as specified and directed. |
| 53 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above ground level) including removal of debris from the site complete all as specified and directed. |
| 54 | M&L for 75 mm thick, PCC (1:3:6) type B-2 using 40 mm graded stone aggregates as in sub base/ Plinth protection ,surface finished fair and smooth with out usig extra cement complete all as specified and directed. |
| 55 | Taking up or down GI tubing 15mm bore including cleaning for refixing complete all as specified and directed. |
| 56 | Taking up or down GI tubing 20mm bore complete all as specified and directed. |
| 57 | S&F in repair 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 58 | S&F in repair 15 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 59 | M&L for cutting chases for concealed water tubing and making good to facing in cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed. |
| 60 | M&L for sunken floor treatment as follows as per S. No. (i) to (v) :- The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.(i) Demolition of concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaned the sunken potion incl vertical wall surface complete as directed.(ii) Top of RCC salb in sunken portion including peripheral beams shall be plastered with 15 mm thick cement and sand mortar (1:3) using approved water proofing compund @3% by weight of cement finished even and smooth without using extra cement and curved adequately and allowed to dry. (iii) Two coats of epoxy resin / polymer modified cementaticious coating like brush bond of Fosroc or equivalent both on floor and walls /beams shall be applied as per manufacturer instuctions.(iv)slabs to be given 1:20 slope outward with 25 mm GI pipe spout with 300 mm projection beyond outer surface of wall complete all as specified and directed.(v) After the surface is passed by the Eng- in- charge for water tightness by flooding for 72 hrs the same shall be filled with lean concere (1:4:8) using type B-1 aggregate , up to the required depth. Surface surrounding to WC Pan shall however be of cement concrete as specified here-in-before. |
| 61 | Taking down of existing roof treatment from roof and terrance, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following specification:- (a) Applying cement slurry over concrete surfaces @3kg/sqm. (b) Roof surface shall be plasterd with 15 mm thick cement mortar 1:4 screed bed over slab when concrete is still green.(c) Curing of slab with ponding with water shall be done all as specified. Ponding test 72 hrs shall be done.(e) Clening of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 Ltr/Sqm conforming to IS: 3384:1986.(f) A layer of APP based polymeric membrane , 3 mm thick (minimum) weight 3.0 kg/Sqm reinforced with polyester non woven fabric (weight not less than 160 gm/sqm ) shall be applies over bituminous primer as specified above . application of polymeric membrane shall by torch application. The overlabs shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction (f) One coat of aluminium paint over the APP modified membrane @ 0.11 Kg per suqare meter. |
| 62 | S&F in repair rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 ltr capacity hoisted and fixed in position with air pipe all as specified including dismantling old one complete all as specified and directed. |
| 63 | S&F in repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 64 | S&F in repair 15mm Bore bib tap cast copper alloy chromium plated fancy type with crunch or butterfly handle screw down scrwed for iron piupe or for brass funnel and fixed, in repair complete all as specified and directed. |
| 65 | S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 66 | S&F in repair Stop valves, fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed. |
| 67 | S &F in repair shower rose 125mm CP fix to iron pipe 15mm complete all as specified and directed. |
| 68 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, 60cm long between flanges complete all as specified and directed. |
| 69 | S&F in repairs PVC low level flushing cistern, white, 10 ltrs capacity with float valve and brackets complete including fixing low level flush pipe after dismantling of old unserviceable existing flushing cistern complete all as specified and directed. |
| 70 | Dismentling and breaking up drain pipes AC/ CI/ PVC Pipes set in cement mortar 100mm/ 75mm bore complete all as specified and directed. |
| 71 | M&L for 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement complete all as specified and directed. |
| 72 | S&F in repair PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 110mm bore complete all as specified and directed. |
| 73 | S&F in repair PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 75mm bore complete all as specified and directed. |
| 74 | S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 75 | S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 76 | S&F for PVC (SWR) single T equal or unequal with access door 110mm bore complete all as specified and directed. |
| 77 | S&F for PVC (SWR) single T equal or unequal with access door 75mm bore complete all as specified and directed. |
| 78 | S&F for PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 79 | S&F in repair 40mm dia waste pipe for sinks, basins, etc complete all as specified and directed. |
| 80 | S&F for grating doom 100/125 mm dia of PTMT (Minimum weight 5gms) complete all as specified and directed. |
| 81 | S&F in repair vitreous china 580x440 mm,\\"ORISSA PATTERN\\" with 'P' or 'S' trap size squatting pan (Exclusive flushing cistern and flush pipe) incl foot rest complete and provision of lime concrete bedding complete all as specified and directed. |
| 82 | M&L for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with PCC (1:1.5:3) type A0 using 12.5 mm graded aggregate) in any slab and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and weldign/binding of reinforcement (including reinforcement) if required complete as directed by engineer in charge complet complete all as specified and directed.Note : Reinforcement will be measured and paid seperately under respective items. |
| 83 | M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 84 | Demolition of Brickwork or stone/ boulder masonary, built in cement mortar or cement lime mortar complete all as specified and directed. |
| 85 | M&L for brick work built in cement mortar (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 86 | S&F in repair 20 mm bore ball brass valve, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 87 | S&F in repair Curtain rod, mild steel, chromium plated with fixing brackets,stops, rollers etc complete all as specified and directed. |
| 88 | Disconnecting existing tanks exc 500 & n.exc 1000, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in postion (cleaning repairing etc measured separately) complete all as specified and directed. |
| 89 | Cutting into existing manholes for connecting new drains, making good to pipe of dia150 mm and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reformiing benching as required complete all as specified and directed. |
| 90 | Taking down carefully copper/aluminum point wiring (light, fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, calling bells etc removing materials for taking credit and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 91 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 92 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 93 | Taking down carefully ceiling fan, sealing cable ends,dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 94 | M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FRLS (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover for mounting of switch, socket and fan regulator complete and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles complete all as specified and directed for the following :- |
| 95 | Light/Fan point controlled by one no one way switch. |
| 96 | One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size |
| 97 | All as per Ser No. 93 but for One light point controlled by two 2-way switches |
| 98 | All as per item Srl No. 93, but 5 Amp Socket on Same board |
| 99 | all as per item Srl No 93, but 5 Amp socket point on independent switch board. |
| 100 | All as per item Srl No. 93, but with 2.5 Sqmm cable for one 15 A socket point on independent board. |
| 101 | S&F for 2 way 6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 102 | S&F for switch piano flush type 1 way 5/6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 103 | S&F for switch socket combination 3 pin 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 104 | S&F for switch socket combination, multipurpose type 6 pin 5/15 A 240 Volts piano flush type complete all as specified and directed. |
| 105 | S&F for ceiling rose surface type bakelite 3 terminals 230 volts AC complete all as specified and directed. |
| 106 | S&F in repair / replacement of bell push switch, piano flush type 5 amps, 240 volts, single pole complete all as specified and directed. |
| 107 | S&F for step type electronic fan regulator piano flush type, 230 volts, 5 speed control complete all as specified and directed. |
| 108 | S&F for invertor type LED lights fitting 1 X 18/20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old one complete all as specified and directed. Make : Havells cat part No LHEXACP7F1W020. |
| 109 | Taking Down serviceable tube light from the wall/ceiling refixing its original place complete all as specified and directed. |
| 110 | S&F in repair of wall mounted endura linear, decorative ultra slim square profile LED 10 watt, 230 volts, 50 Hz lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp complete all as specified and directed. Make Crompton Cat Part No CCS-102-10-65-DP-NWH. |
| 111 | S&F in repair / replacement of lamp holder with 7 watt LED bulb PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. Make : Havells cat Part No LHLDDBEBI2R007. |
| 112 | S&F for LED Building Security Light Fitting 25 Watt, 230 Volt AC,with suitable bracket and clamp, nut bolts, Outdoor type with High Pressure Die Cast Aluminum Housing and Heat Resistant with Driver, Lamp, Surge Protection Device, and Corrosion Resistant including Thermal Management in Multipole Optics, having IP 65/66 Protection and Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size and Length complete all as specified and directed. Make Crompton Cat Part No LSTS-25-CDL-M. |
| 113 | S&F for sheet metal enclosure, MCB DB, double door, single pole & neutral, 8 way, 230 volts, 50Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 114 | S&F for MCB SPN 32 Amps, 230 volts, C - curve, 10 kA complete all as specified and directed. |
| 115 | S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed. |
| 116 | S&F for MCB TPN 40 to 100 Amps, 230 volts, C curve complete. |
| 117 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type including taking down old one complete and making good of disturbed surface complete all as specified and directed. Please Enable Macros to View BoQ information |
| 118 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type including taking down old one complete and making good of disturbed surface complete all as specified and directed. Please Enable Macros to View BoQ information |