| 1 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and for all lift, as directed by Engineer-in-charge.2.6.1 All kinds of soil cum 177.50 |
| 2 | 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived fromnatural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources) cum 6812.00 |
| 3 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 7132.25 |
| 4 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 9105.95 |
| 5 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 1123.80 |
| 6 | 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressedmild steel welded or rigidly fixed together by mechanical means, includingM.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplateand shock absorbers as specified and applying a coat of approvedsteel primer after pre-treatment of the surface as directed by Engineerin-charge:10.14.3 Profile E10.14.3.1 Fixing with adjustable lugs with split end tail toeach jamb metre 640.20 |
| 7 | 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressedmild steel welded or rigidly fixed together by mechanical means, includingM.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplateand shock absorbers as specified and applying a coat of approvedsteel primer after pre-treatment of the surface as directed by Engineerin-charge:10.14.1 Profile B10.14.1.1 Fixing with adjustable lugs with split end tail toeach jamb metre 583.30 |
| 8 | 10.25 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works kg 172.60 |
| 9 | 4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominalsize derived from natural sources) cum 9895.20 |
| 10 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.2 1:6 (1 cement: 6 fine sand) sqm 383.00 |
| 11 | 13.1 12 mm cement plaster of mix :13.1.2 1:6 (1 cement: 6 fine sand) sqm 333.35 |
| 12 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 125 mm each 66.25 |
| 13 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm each 115.15 |
| 14 | 13.37 White washing with lime to give an even shade :13.37.1 New work (three or more coats) sqm 39.05 |
| 15 | 13.39 Colour washing such as green, blue or buff to give an even shade :13.39.1 New work (two or more coats) with a base coat of whitewashing with lime sqm 53.30 |
| 16 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture sqm 170.70 |
| 17 | 11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks:11.1.2 1:6 (1cement : 6 coarse sand) sqm 965.55 |
| 18 | 10.30 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes sqm 1064.65 |
| 19 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete.10.16.1 Hot finished welded type tubes kg 194.40 |
| 20 | 12.1 Providing corrugated G.S. sheet roofing including vertical / curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitchin horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape whereverrequired.12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m² sqm 1457.15 |
| 21 | 12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixedwith polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet andbitumen washers complete.12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m² metre 1083.30 |
| 22 | 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired.1.8.1 Group C Point 1245 |
| 23 | 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required.EACH 358 |
| 24 | 1.9 Wiring for twin control light point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing thepoint with 1.5 sq.mm. FRLS PVC insulated copper conductorsingle core cable etc. as required. Point 1457.00 |
| 25 | 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required. Each 488.00 |
| 26 | 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socketoutlet, with 2 pole and earth, metal enclosed plug topalongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioningetc. as required. Each 1621.00 |
| 27 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 233 |
| 28 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 275 |
| 29 | 1.58 Supplying and fixing PVC batten/ angle holder includingconnections etc. as required. Each 110 |
| 30 | 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. Set 7472 |
| 31 | 5.12 Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. Metre 287 |
| 32 | 2.4 Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door Each 4091 |
| 33 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.2.10.1 Single pole Each 256 |
| 34 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing and2.13.3 100 A Each 1227 |
| 35 | 1.45 Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. Each 339 |
| 36 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer inCharge.Internal work - Exposed on wall18.7.5 40 mm nominal dia Pipes metre 702.95 |
| 37 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer inCharge.Internal work - Exposed on wall18.7.1 15 mm nominal dia Pipes metre 286.80 |
| 38 | 18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA)conforming to IS :1536 :18.27.1 100 mm dia pipe metre 1423.10 |
| 39 | 18.49 Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :18.49.1 15 mm nominal bore each 506.80 |
| 40 | 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:893118.53.1 15 mm nominal bore each 574.30 |
| 41 | 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brasssingle hole basin mixer of approved quality and make, including paintingof fittings and brackets, cutting and making good the walls whereverrequired:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CPBrass single hole basin mixer each 3960.55 |
| 42 | 18.63 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighingnot less than 85 gms each 156.90 |
| 43 | 18.62 Providing and fixing PTMT Ball cock of approved quality, colour and makecomplete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.18.62.1 15 mm nominal bore, 105 mm long, weighing not less than138 gms each 182.10 |
| 44 | 18.58 Providing and fixing PTMT grating of approved quality and colour.18.58.1 Circular type18.58.1.1 100 mm nominal dia each 37.60 |
| 45 | 18.37 Constructing masonry Chamber 60x45x50 cm inside, in brick work incement mortar 1:4 (1 cement : 4 coarse sand) for water meter completewith C.I. double flap surface box 400x200x200 mm (inside) with lockingarrangement and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size), including necessaryexcavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 gradedstone aggregate 40 mm nominal size) and inside plastering with cementmortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floatingcoat of neat cement complete as per standard design :18.37.1 With common burnt clay F.P.S.(non modular) bricks of classdesignation 7.5 each 9698.55 |
| 46 | 17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillarcock, 32 mm PTMT waste coupling of standard pattern, including paintingof fittings and brackets, cutting and making good the walls whereverrequired. White Vitreous China Flat back wash basin size 550x400 mmwith single 15 mm PTMT pillar cock. each 1550.60 |
| 47 | 17.8 Providing and fixing white vitreous china pedestal for wash basin completelyrecessed at the back for the reception of pipes and fittings. each 1683.35 |
| 48 | 17.25 Providing and fixing white vitreous china wash basin including making allconnections but excluding the cost of fittings :17.25.5 Flat back wash basin of size 450x300 mm each 627.00 |
| 49 | 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.17.28.1 Semi rigid pipe17.28.1.1 32 mm dia each 103.90 |
| 50 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and for all lift, as directed by Engineer-in-charge.2.6.1 All kinds of soil cum 177.50 |
| 51 | 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived fromnatural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources) cum 6812.00 |
| 52 | 2.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. cum 2123.75 |
| 53 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 7132.25 |
| 54 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 8288.35 |
| 55 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 1123.80 |
| 56 | 10.14 Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressedmild steel welded or rigidly fixed together by mechanical means, includingM.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplateand shock absorbers as specified and applying a coat of approvedsteel primer after pre-treatment of the surface as directed by Engineerin-charge:10.14.3 Profile E10.14.3.1 Fixing with adjustable lugs with split end tail toeach jamb metre 640.20 |
| 57 | 10.25 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works kg 172.60 |
| 58 | 4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominalsize derived from natural sources) cum 9895.20 |
| 59 | 13.2 15 mm cement plaster on the rough side of single 13.2.2 1:6 (1 cement: 6 fine sand) sqm 383.00 |
| 60 | 13.1 12 mm cement plaster of mix :13.1.2 1:6 (1 cement: 6 fine sand) sqm 333.35 |
| 61 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 125 mm each 66.25 |
| 62 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm each 115.15 |
| 63 | 10.30 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes sqm 1064.65 |
| 64 | 9.51 Providing and fixing fly proof galvanized M.S. wire gauge to windows andclerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete.9.51.2 With 12 mm mild steel U beading sqm 939.20 |
| 65 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture sqm 170.70 |
| 66 | 13.37 White washing with lime to give an even shade :13.37.1 New work (three or more coats) sqm 39.05 |
| 67 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete.10.16.1 Hot finished welded type tubes kg 194.40 |
| 68 | 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required.1.8.3 Group C Point 1445 |
| 69 | 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing andfixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required.EACH 358 |
| 70 | 1.9 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Point 1457.00 |
| 71 | 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. Each 488.00 |
| 72 | 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. Each 1621.00 |
| 73 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 233 |
| 74 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 275 |
| 75 | 1.58 Supplying and fixing PVC batten/ angle holder includingconnections etc. as required. Each 110 |
| 76 | 2.4 Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door Each 4091 |
| 77 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.2.10.1 Single pole Each 256 |
| 78 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing and2.13.3 100 A Each 1227 |
| 79 | 1.45 Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. Each 339 |
| 80 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and for all lift, as directed by Engineer-in-charge.2.6.1 All kinds of soil cum 177.50 |
| 81 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 7132.25 |
| 82 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 9105.95 |
| 83 | 10.25 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works kg 172.60 |
| 84 | 4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominalsize derived from natural sources) cum 9895.20 |
| 85 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.2 1:6 (1 cement: 6 fine sand) sqm 383.00 |
| 86 | 13.1 12 mm cement plaster of mix :13.1.2 1:6 (1 cement: 6 fine sand) sqm 333.35 |
| 87 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. sqm 262.70 |
| 88 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 125 mm each 66.25 |
| 89 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm each 115.15 |
| 90 | 13.41 Distempering with 1st quality acrylic distemper (ready mixed) having VOCcontent less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour :13.41.1 New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC contentless than 50 gram/litre sqm 185.65 |
| 91 | 13.45 Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @2.20kg/10 sqm sqm 223.60 |
| 92 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture sqm 170.70 |
| 93 | 11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks:11.1.2 1:6 (1cement : 6 coarse sand) sqm 965.55 |
| 94 | 10.30 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :10.30.1 4.0 mm thick glass panes sqm 1064.65 |
| 95 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete.10.16.1 Hot finished welded type tubes kg 194.40 |
| 96 | 12.1 Providing corrugated G.S. sheet roofing including vertical / curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitchin horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape whereverrequired.12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m² sqm 1457.15 |
| 97 | 12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixedwith polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet andbitumen washers complete.12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m² metre 1083.30 |
| 98 | 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired.1.8.3 Group C Point 1445 |
| 99 | 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required.EACH 358 |
| 100 | 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required. Each 488.00 |
| 101 | 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socketoutlet, with 2 pole and earth, metal enclosed plug topalongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioningetc. as required. Each 1621.00 |
| 102 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 233 |
| 103 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 275 |
| 104 | 1.58 Supplying and fixing PVC batten/ angle holder includingconnections etc. as required. Each 110 |
| 105 | 2.4 Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door Each 4091 |
| 106 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.2.10.1 Single pole Each 256 |
| 107 | 2.13 Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing and2.13.3 100 A Each 1227 |
| 108 | 1.45 Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required. Each 339 Please Enable Macros to View BoQ information |