| 1 | Civil Works |
| 2 | Electrical Works |
| 3 | Breaking Flooring / Water Proofing |
| 4 | Breaking flooring/waterproofing/ cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.Nominal concrete 1:3:6 or richer mix (including equivalent design mix). |
| 5 | Plaster Breaking with Dado |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | Dismantling 15 to 40 mm dia G.I. pipe |
| 8 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. |
| 9 | Demolishing Brick work |
| 10 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 11 | Removing Door ,Windows & VentilatorDismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead |
| 12 | Windows with mesh grill & grill |
| 13 | Providing and applying Plaster |
| 14 | Providing and laying internal plaster in C.M.(1:4) 12mm thick minimum, to brick masonry and/ or concrete surfaces in any location and at all levels including cleaning and watering the surfaces, filling out hollows or out of plumb surfaces with mortar and finishing to correct line and plumb etc. complete. as per direction of Engineer-in-Charge.” |
| 15 | Ceiling /Wall/Column Repair |
| 16 | Providing and applying rust inhabitation coal/system to exposed reinforcement bars and also new reinforcement bars after removing scales and rust complete as per specification. Providing and applying bond coat to all exposed concrete surface and reinforcement bars prior to any treatment as per specification. Providing and applying single component, fiber reinforced, thixotropic repair mortar of average thickness 50mm and above of \\"'BASF\\" (MASTER EMACO 348 S) as manufacturer's specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc.including carting away debris out of AIESL/Airport premises. Including scaffolding required for it complete . |
| 17 | Providing and laying PCC |
| 18 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:5:10 (1 cement: 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 19 | Providing & Laying Micro concrete |
| 20 | Providing and laying/ pouring in position/ location SMC (Self leveling micro concrete)RENDRC RGL or equivalent as directed or as approved by EIC, mixing with specified quantity of water as recommended by the manufacturer including cutting the existing concrete floor to shape with cutting machine only, dismantling the existing concrete floor, cleaning the surface with water, taking rubbish out of AIESL premises, applying bond coat of RBR or equivalent and cement in proportion 1:1 including necessary approved centering and formwork, finishing top as directed including labour , tools plants etc. complete. as per direction of Engineer-in-Charge.” |
| 21 | Providing & Laying Brick wall |
| 22 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): With Modular bricks. Including scaffolding required for it complete. as per direction of Engineer-in-Charge.” . |
| 23 | Providing & Laying Waterproofing |
| 24 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be |
| 25 | Providing & Laying Waterproofing on Vertical portion |
| 26 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen@ 1.7 kg/sqm). |
| 27 | Providing & Fixing Kota Flooring |
| 28 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand) : 25 mm thick. |
| 29 | Providing & Fixing Kota Flooring |
| 30 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.complete. as per direction of Engineer-in-Charge.”Size of tiles: 300mm x 450mm/ 300mm x 600mm/300mm x900mm/ 600mmx 1200mmNote: Tiles samples shall be approved by the EIC or user department before installation. |
| 31 | Providing & Fixing Granite for Frame-work, Billing counter,Shelf etc |
| 32 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.complete. as per direction of Engineer-inCharge.” Granite stone slab of colour black, Cherry/Ruby red |
| 33 | Floor Polishing |
| 34 | Carrying-out Mirror Polishing on Marble work/ Granite work /Stone work /kota work ,etc, where ever required to give high gloss finish.complete. as per direction of Engineer-in-Charge.” |
| 35 | Providing & Fixing Aluminum for Sliding & Casement Windows ,Ventilators |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) |
| 37 | Providing and fixing zinc alloyed (powder coated) touch lock for sliding window with necessary screws etc. complete. |
| 38 | Providing and fixing aluminium casement ventilator fastener of required length for aluminium ventiltor with necessary screws etc. complete. Anodized (AC 15) aluminium |
| 39 | Providing & Fixing Glass For Window / Ventilator |
| 40 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not lesst than 12.50 kg/sqm) |
| 41 | Providing & Fixing Mosquito mesh |
| 42 | Providing & fixing fly proof wire gauze to windows, clerestory windows ,ventilators & doors with M.S. Flat 15x3 mm and nuts & bolts.complete. as per direction of Engineer-in-Charge.”Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 43 | Providing & Applying Paint O.B.D |
| 44 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour. Old work (one or more coats) |
| 45 | Providing & Applying SEP Paint |
| 46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 47 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 48 | Providing and applying plaster of paris putty of 5-8 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 49 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wal |
| 51 | 15 mm nominal dia Pipes |
| 52 | 20 mm nominal dia Pipes |
| 53 | 25 mm nominal dia Pipes |
| 54 | 32 mm nominal dia Pipes |
| 55 | 40 mm nominal dia Pipes |
| 56 | 50 mm nominal dia Pipes |
| 57 | Providing & Fixing CPVC Plumbing line:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 58 | 15 mm nominal dia Pipes |
| 59 | 20 mm nominal dia Pipes |
| 60 | 25 mm nominal dia Pipes |
| 61 | 32 mm nominal dia Pipes |
| 62 | Providing & Fixing PVC pipe:Providing and fixing PVC rain / Waste water pipe of ‘’Prince’’ or equivalent approved make conforming to IS 13592 of SWR quality 4 kg/cm2 pressure rated, at any locations and at all levels, scaffolding etc. including all PVC fittings like bends, shoes, clamps, supports etc. jointing with rubber ring/ solvent cement, leak proof adhesive etc. cutting and making good the walls and floors etc. complete. As per instruction of EIC.40 mm dia with GI clamps & GI brackets (Vertical pipes should be fitted 50 mm away from the wall) |
| 63 | 110mm |
| 64 | Providing & Fixing Stop cock |
| 65 | Providing & Fixing Nahani trap jali |
| 66 | Providing & Fixing Stainless steel sink for washing utensil |
| 67 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perIS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : complete. as per direction of Engineer-in Charge.”Kitchen sink without drain board - 610x510 mm bowl depth 200 mm |
| 68 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore. |
| 69 | New Wash-basin |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:complete. as per direction of Engineer-in-Charge.”White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 71 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931: 15 mm nominal bore. |
| 72 | Providing and fixing P.V.C. waste pipe for sink or wash basin including. P.V.C. waste fittings complete. |
| 73 | Flexible pipe - 40 mm dia |
| 74 | Providing and fixing PTMT Waste Coupling for wash basin and sink of approved quality and colour.( jaquar) |
| 75 | Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
| 76 | Providing & fixing Door Frames |
| 77 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 50 x 100 mm. |
| 78 | Providing & fixing Doors Shutters |
| 79 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 80 | Butt Hinges |
| 81 | Providing and fixing ISI marked aluminium butt hinges anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete. 125 x 75 x 4mm |
| 82 | Door Closer |
| 83 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 84 | Providing Aldrop |
| 85 | Providing and fixing aluminium sliding door bolts , ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868 ) ,transparent or dyed to required colour or shade , with nuts and screws etc. complete. 300x16 mm |
| 86 | Handel for Door |
| 87 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. Anodized (AC 15) aluminium |
| 88 | Concrete for lintel |
| 89 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 90 | For Lintel & Frame work support for Water-tank |
| 91 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 92 | MS Chequer plate, Grating etc. |
| 93 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.complete.as per direction of Engineer-in-Charge.”In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 94 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 95 | Providing & Fixing Sintex Water Tank a UV-stabilized, multi layered Sintex brand PVC water storage tank of a specified capacity (e.g., 1,000 litres) and make, complete with a threaded lid and proper ventilation.complete as per direction of Engineer-in-charge. |
| 96 | Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS : 710 of approved brand boxes, shelves,racks, almirah, cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in- charge. |
| 97 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 98 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type) |
| 99 | Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer-in-charge. |
| 100 | Carting away debirs |
| 101 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 102 | Providing & Fixing decorative high pressure laminated sheet of plain/ wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality and removing of exisiting laminate/ door skin. 1.00 mm thick |
| 103 | For incomer from Main panel to VTPN DB -SITC of 4C × 150 sqmm Aluminium armored Cable 1100 volts grade. Job includes installation of cable on and through the wall with all required hardware, support, saddle, end termination. All compelet as directed by EIC. Approved make - Polycab, finolex. |
| 104 | For 3 phase power supply to various 3 phase apparatus - SITC of 4C X 4 sqmm copper armoured cable on wall. Job involved laying of cable on and through the wall with end termination with all required hardware and consumable. All complete as directed by EIC.Approved make - Polycab, finolex. |
| 105 | For 1 phase power supply to various 1 phase apparatus- SITC of 3C X 4 sqmm copper armoured cable on wall. Job involved laying of cable on and through the wall with end termination with all required hardware and consumable. All complete as directed by EIC. Approved make - Polycab, finolex. |
| 106 | Supply cable for Fan Switch board - Supply and laying 2.5 sqmm pvc flexible wire. Job includes laying and pulling wire through 20 mm MS conduit pipe with connection to both end. All complete as directed by EIC. Approved make - Polycab, finolex. |
| 107 | For Fan & misc. use - SITC of 6 Moduler type combine 2switch 2socket box. Job includes fixing of box/board of 10A switch and 6A socket with plate on the wall with power supply connection from source to switch socket board/box. using wire & casing capping with all required hardware ,tools, manpower, material. all complete as directed by EIC. Apporoved make - ROMA, Anchor, GM. |
| 108 | For Main DB - Supply and Installation of 12 WAY VTPN D.B. Incomer- 250A MCCB Outgoing- 63A MCB (12 qty) with mounting bracket, in/out cable connection with required harwdare with Removal of old D.B. All complete, as directed by EIC. Approved make - L & T, Siemens, Snider. |
| 109 | For Main DB - Supply and Installation of 8 WAY VTPN D.B. Incomer- 150A MCCB Outgoing- 63A MCB (12 qty) with mounting bracket, in/out cable connection with required harwdare with Removal of old D.B. All complete, as directed by EIC. Approved make - L & T, Siemens, Snider. |
| 110 | For switch to VTPN DB - SITC of 630A fn type switch with encloser. Job includes installation with bracket, all connection and desire sizze of cable to connect from fn switch to incomer for 2 Nos of VTPN DB. All complete as directed by EIC. |
| 111 | For 3 phase point - Supply and installation of 32A powder coated MS industrial type 5 pin socket with MCB power supply box with all required hardware material. All compelet as directed by EIC. Approved make - L & T, Siemens, Snider. |
| 112 | For 1 phase point - Supply and installation of 32A powder coated MS industrial type 3 pin socket with MCB power supply box with all required hardware material. All compelet as directed by EIC. Approved make - L & T, Siemens, Snider |
| 113 | Supply and installation of LED tubelight fitting batten type with all required hardware material. All compelet as directed by EIC. Approved make - Philip, Surya, Wipro. |
| 114 | Supply and installation of 12\\" Exhuast fan with all required hardware material. All compelet as directed by EIC. Approved make - Almonard, Crompton, Bajaj. |
| 115 | Supply, installation of MS conduit pipe 25 mm, black color with all required hardware like saddle, screw etc. |
| 116 | Ducting/ chemney for canteen aprox 10 to 30 meter in length Please Enable Macros to View BoQ information |