| 1 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified and directed. |
| 2 | M & L for hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. |
| 3 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering complete all as specified and directed. |
| 4 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundations, filling and mass-concrete complete all as specified and directed. |
| 5 | M&L for RCC M-25 cement concrete using 20 mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed |
| 6 | M&L for RCC M25 cement concrete using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 7 | M&L for RCC type M25 Cement concrete using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 8 | M&L for RCC M 25 Cement Concrete using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, chajja, deck slabs and in shelves and the like complete all as specified and directed. |
| 9 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 10 | M&L Mild steel TMT bars 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 11 | M&L Mild steel TMT bars 8mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed. |
| 12 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Fair finished surfaces of concrete flat complete all as specified and directed. |
| 13 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed. |
| 14 | Use and waste formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. rough finished surfaces of concrete flat complete all as specified and directed. |
| 15 | Use and waste formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed. |
| 16 | M&L for brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 17 | M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built in CM (1:6) complete all as specified and directed. |
| 18 | Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 19 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed. |
| 20 | M&L for 40mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate complete all as specified and directed. |
| 21 | S&F Steel ventilators with top hung shutter including hinges,steel peg stay, complete all as specified and directed. |
| 22 | S&F figured glass 3.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed. |
| 23 | M&L 75mm thick (1:4:8) PCC type D-2, using 40mm graded stone aggregate as in sub base complete complete all as specified and directed. |
| 24 | M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with water proofing compound as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 25 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces (without using extra cement) in CM (1:6) on external surface complete all as specified and directed. |
| 26 | M&L rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed. |
| 27 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening as per specification & drawing complete all as specified and directed. |
| 28 | S&F Factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 29 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site as per specification & drawing complete all as specified and directed. |
| 30 | S&F Aluminium, anodised, 150mm long barrel tower bolts of extruded section complete all as specified and directed. |
| 31 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 32 | S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed. |
| 33 | S&F Butt hinges 100mm size, medium weight, cold rolled mild steel complete all as specified and directed. |
| 34 | S&F coloured non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed in CM(1:6) complete all as specified and directed. |
| 35 | S&F coloured Glazed ceramic tiles in vertical surfaces 350x250mmx7mm /450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM(1:4) as backing coat complete all as specified and directed. |
| 36 | M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection complete all as specified and directed. |
| 37 | Supplying & Laying of 20 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 38 | Supplying & Laying of 25 mm Outer Diameter, CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 39 | S&F 1000 Ltrs Capacity rotational moulded polyethylene water storage tank (minimum triple layer) (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 40 | S&F Ball brass valves 20mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 41 | S&F CP Bib taps 15 mm bore, cast copper alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 42 | S&F Stop valves 15 mm bore, cast copper alloy screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 43 | S&F Stop valves 20 mm bore, cast copper alloy screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 44 | S&F CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 45 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) complete all as specified and directed. |
| 46 | S&F Plastic water closet seat, black, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed. |
| 47 | S&F PVC valveless, syphonic action type, flushing cistern 10 litr capacity, low level, white, with inlet, ball valve, float & handle including brackets complete all as specified and directed. |
| 48 | S&F Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain & plug & porcelain stopper including brackets complete all as specified and directed. |
| 49 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (min.), with grating & union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) complete all as specified and directed. |
| 50 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers complete all as specified and directed. |
| 51 | S&F towel rail 600mm long of PTMT fixed with & including CP brass screws & wooden/plastic cleats (min. weight 190gms) complete all as specified and directed. |
| 52 | S&F PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed. |
| 53 | S&F Soap dish, CP, approximate size 160x160x90mm complete all as specified and directed. |
| 54 | S&F Grating doom 100 mm dia of PTMT (min. weight 25 gms) complete all as specified and directed. |
| 55 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 56 | S&F PVC (SWR) 'S' trap of 110mm bore complete all as specified and directed. |
| 57 | S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 58 | M&L PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and directed. |
| 59 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 60 | S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed. |
| 61 | S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed. |
| 62 | M&L for preparation of untreated or new plastered surface of wall and applying three coats of white wash on new wall surface complete all as specified and directed. |
| 63 | M&L for preparation of untreated or new plastered surface of wall and applying two coats of cement base paint, white or tinted over a coat of primer on new wall complete all as specified and directed. |
| 64 | M&L for preparation of untreated or new plastered surface of wall and applying three coats of white wash on new ceiling surface complete all as specified and directed. |
| 65 | M&L for preparation of untreated or new plastered surface of wall and applying two coats of synthetic enamel paint over one coat of red oxide, zinc chrome on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed. |
| 66 | M&L PCC type B1 (1:2:4) using 20 mm graded aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. |
| 67 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even & smooth (without using extra lime or cement) complete all as specified and directed. |
| 68 | Supplying only Integral waterproofing compound |
| 69 | S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed. |
| 70 | M&L for water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer, properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 71 | M&L for 10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 complete all as specified and directed. |
| 72 | M&L for applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm complete all as specified and directed. |
| 73 | M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm including cleaning surfaces complete all as specified and directed. |
| 74 | M&L for laying 3 mm thick APP membrane unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction. |
| 75 | M&L for applying two coats of bituminous base aluminium paint including preparation complete all as specified and directed. |
| 76 | S&F UPVC Tubes, with all fitting & fixed complete to walls / ceilings or laid in floors of 15mm bore complete all as specified and directed. |
| 77 | S&F UPVC Tubes, with all fitting & fixed complete to walls / ceilings or laid in floors of 20mm bore complete all as specified and directed. |
| 78 | M&L PCC (1:4:8) typ D2 concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; complete all as specified and directed. |
| 79 | M&L Salt-glazed stoneware drain pipes laid in trenches & jointed as specfified of 150mm dia complete all as specified and directed. |
| 80 | M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 81 | Excavation in post holes (or similar holes) each not exceeding 0.50 cum in hard/dense soil, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering & removing surplus soil to a distance not exceeding 50 m & making good surface complete all as specified & directed. |
| 82 | M&L for cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 83 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and directed. |
| 84 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 85 | S&F of Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 86 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 87 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 88 | Excavating over areas, not exc. 1.50 m deep & getting out in soft/loose soil complete all as specified and directed. |
| 89 | Removing surplus excavated material (Soil) to a distance exceeding 250 m but not exc. 500 m & depositing where directed at a level not exceeding 1.5 metre above the starting point, including spreading complete all as specified & directed. |
| 90 | M&L rendering 15mm thick on fair faces of brick work or concrete surfaces (without using extra cement) in CM (1:6) on external surface complete all as specified and directed. |
| 91 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness with grey cement and no pigment complete all specified and directed. |
| 92 | M&L for sand filing as in cushioning layer below interlocking paver tiles well compacted to a true surface complete all as specified and directed. |
| 93 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be drawn through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 94 | One light point controlled by one way switch 5/6 amps. |
| 95 | One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 96 | One socket out let 5/6 amps point on the same board |
| 97 | One socket out let 5/6 amps point on the independent board |
| 98 | All as per item No 93.00 here-in-before but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 99 | S&F switch piano flush type 5/6 amps white/ivory single pole one way complete all as specified and directed. |
| 100 | S&F socket 3 Pin, 5/6 amps, white/ivory finish flash type complete all as specified and directed. |
| 101 | S&F of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 102 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 103 | S&F for modular Switch , single pole, one way and 5/6 Amp, single modular complete all as specified and directed. |
| 104 | S&F for modular Socket outlet 6 A 2/3 pin Amp, single modular complete all as specified and directed. |
| 105 | S&F ceiling rose, bakelite, surface type, 65x20mm, three terminals complete all as specified and directed. |
| 106 | S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed |
| 107 | S&F 9 W LED bulb complete all as specified & directed. |
| 108 | S & F deluxe fan electronic regulator 120/180 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed. |
| 109 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and provision of 3 core flexible multistranded copper conductorof size 0.75 Sqmm from ceiling rose to fan all as specified and directed. |
| 110 | Supply and fix of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) |
| 111 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 112 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral,240 Volt with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete all as specified and directed by Engr-in-Charge. Note : MCBs will be measured and paid separately |
| 113 | Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed. |
| 114 | Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SPN, 32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed. |
| 115 | Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed. |
| 116 | S&F, IP 20, class I, LED tube light fittings 20W (or nearest next higher wattage) (4feet), wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up to ceiling rose with including twin core twisted flexible copper conductor cable of suitable size complete all as specified. |
| 117 | S & F new 1 X 10 W, 2 feet,LED light fittings wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and integrated electric driver including 1 x10W LED Tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. |
| 118 | Supply & fix LED Security Light 35 watt with 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base,pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint complete all as specified and as directed. |
| 119 | Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete.Note:- If earth resistance of earthing is not found satisfactory, it will be redone by the contractor without any extra cost to Govt. |
| 120 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 121 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 122 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil complete all as specified and directed. |
| 123 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness shall be considered for payment as per para 19.75 of SSR Part-I) |
| 124 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common Fly Ash building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge. |
| 125 | M & L for boring of horizontally holes by manual method under road below 1 meter from the road surface and dia of hole not exe 40mm without damaging the existing road getting out and disposal of excavated soil,etc to a distance not exc 50meter from the site of work complete all as directed by Engr in Charge. |
| 126 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed. |
| 127 | M& L for cutting existing GI pipe alteration or addition of 25/32 mm dia bore for inerstion of reducer Tee complete with all accessories all as specified and directed by Engineer-in-charge. |
| 128 | M/L GI tubing medium grade laid in trenches/wall bore of pipe of 20 mm dia bore with all fittings such as bend,elbow,tees,short pipe connector, caps, plug and union etc completed all as specified and directed. |
| 129 | Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 20 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge. |
| 130 | M & L brick masonry valve pits of size 45X45X45 cm (internal dimension) with brick work in cement mortar (1:4) with angle iron frame, MS handle bent to shape and riveted to MS sheet including excavation and earth work, concrete work, 3.15 mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and applying one coat of lime wash complete all as specified and directed. |
| 131 | S&F single pointed air termination Aluminium rod, 12mm dia, 300mm long complete all as specified and directed |
| 132 | S&F aluminium strips size 25 mm x 3.15mm complete with saddles and screws for fitting the strip complete all as specified and directed. |
| 133 | S&F test point for aluminium strip and GI strips complete with not bolts washer etc (size 75X75X25 mm Gun metal) complete all as specified and directed. |
| 134 | Supply and install GI strip 32 mm x 6 mm buried In ground complete all as specified and directed. |
| 135 | M&L Earthing complete with galvanized steel earth plate electrode 600mmx60 0mmx 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connected to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as per Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on complition completed all as specified and directed. |
| 136 | S & F Fire alarm control panel complying with BS EN 54 but of 2 loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules( Per each loop) complete all as specified and directed. |
| 137 | S & F Detectors Complying with and type certified to EN - 45 but Addressable type multisensor detector with heat and smoke combination complete all as specified and directed. |
| 138 | Supply and install Addressable Manual call point having an integrally mounted addressable module that monitors and reports contact status. (PULL TYPE).The Junction box and other accessories as required and Call units shall be shall be made of or enclosed inside the Exp Proof enclosures complete all as specified and directed. |
| 139 | Supply lay connect and fix 2 C x 1.5 Sq mm, multistranded Copper conductor,Type A ST1 PVC insulated,Armoured Mica Insulated fire Survival as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete all as specified and directed. |
| 140 | Supply and erect Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) with foundation and coping complete all as specified and directed. |
| 141 | M&L for ACSR conductor with insulators to fix on poles complete all as psecified and directed. |
| 142 | M & L for Stay assembly with stay rod of 16mm dia complete with all accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed. |
| 143 | M & L for loop type insulator vitrous porcelain white, brown or green large size with dimensions 90mmx140mm, clearance of hole 25.5mm etc complete all as specified and directed. |
| 144 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 145 | M & L for Brass Copper Lightning Arrester 9.2 mm diameter and 915 mm in length And Epoxy electrical Insulator For Lightning Arrester complete all as specified and directed. |
| 146 | S & F 6 Watt ceiling Speaker on suitable place as directed by engineer in charge |
| 147 | Supply and Install, testing and Commissioing of Heavy duty Industrial air cooler, Single phase, 230 Volt, power capacity 490 W with 3 variable speeds on movable stand, , comprising of the following :- (a) Cooler shall be fabricated with plastic material. The depth of the tank shall not be less than 35 cm . (b) Axial fan size shall not be less than 24 inch single phase 230 volts heavy duty . fan speed 950 RPM of air flow not less than 10500 CFM with effective cooling area approx 2500 sqft and coling pad size not less than 1100x100x1150 mm.(c) Copper wiring, switches, copper cable not less than 3 core of size 2.5 sqmm not less than 2.5 RM complete with three pin top 15 Amps and fan regulator with 3 variable speeds to control fan speed and fixed on front facia of cooler.(d) Heavy duty moveable trolly with 4 Nos of wheels, revolving type, suitable for moving to any direction. |
| 148 | Schedule of credit amount of Rs 0.00 to be deducted during AOC. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail