Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and directed. |
| 2 | M&L for Rendering 10mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 finished fair and even without using extra cement complete all as specified and directed. |
| 3 | M&L for Rendering 15mm thick on fair faces of brick work or concrete exterior surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing of water proofing compound as per manufacture instruction complete all as specified and directed. |
| 4 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of ceiling, chajja in CM 1:3 surface finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for preparation of new surfaces of plastered of walls and applying two coat of distemper oil emulsion incl priming the surface and incl 3mm thick wall putty complete all as specified and directed. |
| 6 | M&L for preparing new surfaces of walls and applying two coat of cement based paint complete all as specified and directed. (Note : Rate shall be included for necessary scaffolding and safety measures where required at site) |
| 7 | M&L for preparation of newly plastered surface and applying three coats of white wash on ceiling complete all as specified and directed. |
| 8 | M&L for preparation of old plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed. |
| 9 | M&L for preparation of old painted surface & applying two coat of synthetic enamel paint on old wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed. |
| 10 | M&L for preparation of old painted surface & applying two coat of synthetic enamel paint on old steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including complete all as specified and directed. |
| 11 | M&L for Complete removal of existing treatment and preparation of surfaces and applying two coat with distemper oil emulsion with 3mm thick putty including primer on old treated surfaces of wall etc complete all as specified and directed. Contractor shall furnish the four year gaurantee against service rendered. (painting upto any height). (Note:- Rate shall be included for necessary scaffolding and safety measures where required at site). |
| 12 | M&L for complete removal of existing treament and preparation of surfaces and applying two coat synthetic enamel oil paint over applying minimum 2mm thick wall care putty over prepared surface including primimg the surface to achive the surface even and smooth for painting complete all as specified and directed (Note:- Rate shall be included for necessary scaffolding and safety measures where required at site). |
| 13 | M&L for preparation of old surface of wall, washing, scrubbing down and stopping old treatment and painted surface of plastered/ decorated surface and applying two coat of Premium Acrylic smooth exterior paint with 2mm thick putty including primer complete all as specified and directed. (Note : painting will be done by brush/ spray/ roller of building upto any height complete all as specified and directed) (Note : Rate shall be included for necessary scaffolding and safety measures where required at site). |
| 14 | Taking down chowkats or frame of any description n.exc. 1.5 Sqm each (without taking off shutters from the frames) & remove from the premises complete all as specified and directed. |
| 15 | Solid PVC door frame of size 50mm 47mm made out of 5mm plain colour PVC sheet rinforced with MS Square tube suppling and fixing in opening as per specification and drawing. complete all as specified and directed. |
| 16 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip if 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bootom rail on either side & as gap insert for top rail and bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 17 | Taking down chowkats or frame of any description exc 1.5 Sqm each and n.exc 4Sqm (without taking off shutters from the frames) complete all as specified and directed. |
| 18 | S&F Pressed steel door frame for single door, size 105 x 60 x 1mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfast (size 25mm x 3mm) of length 30 cm) etc., including Cutting holes in brick walls built in cement mortor for inserting holdfasts and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B-1, depth of embedded portion of holdfasts exc. Half brick but not exc. One brick from the face of the jamb intl the wall complete all as specified and as directed. |
| 19 | M&L for PCC 1:2:4 type B0 (12.5mm graded) aggregate for filling in pressed steel door framed complete all as specified and directed. |
| 20 | S&F 30mm thick second class hardwood rail and style, Plain, framed, panelled shutters Plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 21 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and directed. |
| 22 | M&L for brick work with modular size kiln well burnt bricks sub-class 'B', straight or curved on plan not exc 6m mean radius, built in CM 1:6, complete all as specified and directed. |
| 23 | S&F 150mm size aluminium, anodised barrel tower bolt of extruded section. complete all as specified and directed. |
| 24 | S&F 125mm size aluminium, anodised barrel tower bolt of extruded section. complete all as specified and directed. |
| 25 | S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. complete all as specified and directed. |
| 26 | S&F 100mm size, butt hinges, medium weight, cold rolled mild steel. complete all as specified and directed. |
| 27 | S&F 150mm size extruded aluminium alloy handles, fabricated type complete all as specified and directed. |
| 28 | Taking down existing waterproofing treatment of tar felt of any description from roof surfaces and removing rubbilsh to a distance not exc 100mtres complete all as specified and directed. |
| 29 | M&L for 10mm thick screed bed on concrete surfaces in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for PCC 25mm thick (1:2:4) type Bo using 12mm graded stone aggregates mixed with integral waterproofing chemical mixed in proportion of 200ML/50Kg cement as in padding on roof surfaces for correcting/ making proper slope on roof/ chhaja and roof kerbs/ benching complete all as specified and directed. |
| 31 | Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, having 10 years gurantee for water tightness complete all as specified and described as under:-(a) Preparation of RCC roof surface and cleaning surface all as per manufaturer's specification complete all as specified and directed.(b) Supply & providing water proofing with 3mm thick APP polymeric proofing membran of 3Kg/Sqm HYPERPLAS STANDARD/ MULTIPLAS STANDARD consisting of 100micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed. (c) Aluminium bituminous paint @1.10 Kg/Sqm shall be applied over the APP membrane surface. Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. |
| 32 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all as specified and directed. |
| 33 | S&F in repair 15mm size PVC connections internally threaded with PVC washer, PTMT nuts of length 450mm complete all as specified and directed. |
| 34 | S&F CP Grating 100mm dia with or without hole complete all as specified and directed. |
| 35 | S&F in repair 15mm dia bib tap long body cast copper alloy (fancy type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 36 | S&F in repairs 15mm dia bore fancy type chromium plated swan neck pillar tap, cast copper alloy, with capstan heads, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed. |
| 37 | S&F in repairs plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinge device complete all as specified and directed. |
| 38 | S&F in repair jet spray for pedestal pattern water closet complete all as specified and directed. |
| 39 | S & Fixed in repair Vitreous china, wash down water closet pan (pedestal pattern), white, including plastic water closet seat cover, closed pattern with flat bottom, connection to drain (or outgoing pipe) and to flushing pipe, antisiphonage pipe etc, complete all as specified and directed. |
| 40 | S&F in repair vitreous china squatting pan (orissa pattern) size 580mm x 440mm, white with integral foot rest, any pattern including provision of cement concrete bedding (excluding fulshing cistern and flush pipe) with S or P trap, Fixed in repairs, complete all as specified and directed. |
| 41 | S&F in repairs low level Flushing cistern 10 ltr capacity, PVC valve less syphonic action type, white with inlet, ball valve, float valve and handle, flush pipe, incl brackets and flushing pipe fixed in repairs complete all as specified and directed. |
| 42 | S&F in repairs vitreous china, white, wash hand basin, flat back size 550 x 400mm 'including MS brackets including cutting for and pinning in, including waste pipe complete all as specified and directed. |
| 43 | S&F in repair 110mm dia Cast iron Floor/ nahani trap with CP grating including including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 44 | S&F in repairs Health Faucet ABS with Rubbit Cleaning System, 1.25 m Long PVC Flexible Tube & ABS Wall Hook complete all as specified and directed. |
| 45 | S&F in repairs Stop/angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and directed. |
| 46 | S&F in repairs two way Stop/ angle cock 15mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and directed. |
| 47 | S&F in reparis Flexible waste pipe for wash hand basin fittled to Wash Hand Basin incl all necessary brackets etc complete all as specified and directed. |
| 48 | M&L for welding in repairs not exc 2.5 cm each with thickness of metal to be welded not exc 6mm, complete all as specified and directed. |
| 49 | Dismantling of Plain or corrugated steel/ AC sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 50 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 51 | S&F Plain, galvanised, mild steel sheeting thickness 0.63mm, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 52 | S&F Steel work in tubular trusses, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc. complete all as specified and directed. |
| 53 | M&L for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. |
| 54 | Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete removal of debris outside MD land complete all as specified and directed. |
| 55 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 56 | M&L for 16 to 20mm thick Granite (of any type) work (table rubbed and polished and exposed visible edge moulding/ rounding) in steps, jambs, pillars, window cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 57 | S&F in repair Stainless steel curtain rod/ rail 25mm dia medium weight with premium quality incl SS brackets with decorative caps as approved by Engr-in-Charge complete all as specified and directed. |
| 58 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls with clamps complete all as specified and directed. (Note : Rate of necessary scaffolding upto any height will be included in quated rate) |
| 59 | S&F in repair 110mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls with clamps complete all as specified and directed. (Note : Rate of necessary scaffolding upto any height will be included in quated rate) |
| 60 | S&F 75mm dia PVC (SWR) bends with access doors any radius complete all as specified and directed. |
| 61 | S&F 110mm dia PVC (SWR) bends with access doors any radius complete all as specified and directed. |
| 62 | S&F in repair 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including removing the existing water tank all as specified in SSR Part-I, complete all as specified and directed.. |
| 63 | S&F in repair 500 ltr capacity rotational moulded polythyiene water storages tanks (cylindrical vartical with closed top) hoisted and fixed in position including removing the existing water tank all as specified in SSR Part-I (complete all as specified and directed). |
| 64 | S&F, in repair PVC ball valves high pressure with epoxy coated aluminium rod & high density polyethylene ball screwed for 15mm bore pipes, complete all as specified and directed. |
| 65 | S&F in repair PVC ball valves high pressure with epoxy coated aluminium rod & high density polyethylene ball screwed for 20mm bore pipes, complete all as specified and directed. |
| 66 | S&F in repair PVC water tank covers premium quality fitted to tank. Water tanks of Cap. 500 ltrs to 1000 ltr complete all as specified and directed. |
| 67 | S&F in repair brass spindles, heavy duty, for pillar cock, CP stop cock, CP bib cock, concealed stop cock, wall mixer, sink mixer in any size etc. complete all as specified and directed. |
| 68 | S&F in repair 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 69 | S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 70 | M&L in repair 12mm thick plywood, commercial quality, BWR grade, type BB, 7 ply, fixed with screws to timber frame work complete all as specified and directed. |
| 71 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed. |
| 72 | M&L for Vitrified Ceramic tiles 10mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured epoxy grout filling to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 73 | All as per Srl item No.72.00 above but on vertical surfaces such as skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 74 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured grout filling to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 75 | M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/ shade) of 300 x 450 x 7mm/ 300 x 250 x 7mm thick in vertical surfaces, as in dado/ skirting etc set & jointed in neat cement slurry & pointed in coloured grout filling to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 76 | M&L for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors or coloured grout filling to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 77 | Taking up or down 15mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed |
| 78 | S&F of 15mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specified and directed. |
| 79 | Taking up or down 20mm bore steel tubing and connections, including cleaning for re fixing complete all as specified and directed. |
| 80 | S&F of 20mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specified and directed. |
| 81 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 82 | M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 83 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame incl punching or drilling out old glazing pins/ spring clips and providing and fixing new ones, complete all as specified and directed. |
| 84 | M&L for 4mm thick sheet glass, ordinary quality and glazing with oil putty and fitted in wooden/ steel window in square n exc 0.5 Sqm in each pane, complete all as specified and directed. |
| 85 | M&L for 4mm thick sheet figured glass, pin headed type and glazing with oil putty in square n exc 0.5 Sqm in each pane, complete all as specified and directed. |
| 86 | M&L for Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 87 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 40mm thick bed of crushed stone, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 88 | M&L for providing cement concrete Type B1 1:2:4 (20mm graded aggregate) as in coping. |
| 89 | Cleaning RCC tank and removing all scale and dirt, etc, from tanks. The complete tank be scrub to remove dirt, sediments, fungus & stains. The vacuumed tank is disinfected with anti-bacterial spray or liquid bleach. Tank is filled with water that is made to run through the taps to disinfect the water pipes, etc. and hoisting if required, reconnecting and re-fixing in the same position, date of cleaning should be write by erasing the previous date of cleaning with paint and further writing the current date of cleaning. Note:- (i) cleaning shall be the responsibility of the contractor for the entire period of contract. |
| 90 | Disconnecting existing tanks PVC (500 ltrs to 1000 ltrs capacity), setting aside (or lowering if required) for Cleaning and removing all scale and dirt, etc, from tanks. The complete tank be scrub to remove dirt, sediments, fungus & stains. The vacuumed tank is disinfected with anti-bacterial spray or liquid bleach. Tank is filled with water that is made to run through the taps to disinfect the water pipes, etc. and hoisting if required, reconnecting and re-fixing in the same position, date of cleaning should be write by erasing the previous date of cleaning with paint and further writing the current date of cleaning. Note:- (i) Cleaning shall be the responsibility of the contractor for the entire period of contract. |
| 91 | M&L for cleaning of man holes not exc 1.5 mtr deep and removing slaudge/ waste material to distance n.exc 50 mtr and burying in pits complete all as specified and directed. |
| 92 | Cleaning of underground drain pipe of 100mm bore including manholes by rodding from manhole to manhole, manhole to septic tank, flushing with water taking out sludge and other materials blocking the drain pipes, carrying/ removing the same outside the defence land complete all as specified and directed. |
| 93 | Supply and fix in repair switch piano flush type, 5 Amps, 230V AC, single pole, one way complete all as specified and directed. |
| 94 | Supply and fix in repair switch piano flush type 15 Amps, 230V AC single pole one way complete all as specified and directed. |
| 95 | Supply and fix in repair socket out let multipurpose suitable for 2/3 pin 5 Amp flush type complete all as specified and directed. |
| 96 | Supply and fix in repair socket out let 2 IN 1, multipurpose suitable for 3 pin 5/15 amp flush type complete all as specified and directed. |
| 97 | Supply and fix in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal as per site requirement complete all as specified and directed. |
| 98 | Supply and fix in repairs, angle/ batton type holder insulated body in white colour complete all as specified and directed. |
| 99 | Supply and fix in repairs ceiling rose, 240V polycorbonate isolated body for surface type, three terminals complete all as specified and directed. |
| 100 | Supply and fix in repairs bell push, flush type 5 Amp, 220 V, single pole complete all as specified and directed. |
| 101 | Supply and fix in repairs, electric bell, ding dong, AC, 220 V, single pole complete all as specified and directed. |
| 102 | S & F in repairs for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including taking down old u/s complete all as specified and directed. |
| 103 | S & F for Energy saving new generation environmental friendly long life versatile LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary mounting arrangements and provision of 2.5 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting and necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts including taking down old unsv street light complete all as specified and directed. |
| 104 | Supply and fixing led street light 90 Watt with Epoxy Polyster powder coated pressure die-cast aluminium housing, LEDs are provided with non-yellowing decorative IP lens optic,Silicon gaskets provided for LEDs and control gear compartments, The driver used is specially designed to have built-in surge voltage, open/ short circuit protections, External surge protection provided for additional safety, Side entry mounting for 55 to 65mm OD pipe bracket. ressure die-cast aluminium housing for aiming adjustment of 90 watt led street light with high power led lumnious efficacy 130 lm/watt,correlated color temperature 5665K±355K, luminous flux 11700 lm, CRI >70, Die cast aluminum body with pennut lens, Impact resistence 08, Ingress protection 66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minimum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips or authorisedonly, Power factor will be >0.95 not less than .95 Warranty certificate of LED fitting should be atleast 3 years and same should be produced to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable incl taking down old unsv street light complete all as specified and directed. |
| 105 | All as per Srl item No. 104.00 above but capacity 60 Watts, complete all as specified and directed. |
| 106 | Supply and fixing of 120 watt led flood light Graphite grey powder coated; matt finished pressure diecast aluminium housing designed to act as heat sink for efficient dissipation of heat, Heat resistant toughened glass provided with silicon gasket for efficient Ingress protection, LEDs are provided with secondary polycarbonate lens optics to get optimum optical performance, Constant current LED driver used is specially designed to have built-in surge voltage, open/short circuit protections. Luminaire is provided with a MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment of 200 watt led flood light with high power led lumnious efficacy 120 lm/watt,correlated color temperature 5665K±355K, luminous flux 24000 lm, CRI >70, Die cast aluminum body with toughned glass along with pennut lens, Impact resistence 08, Ingress protection >66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips only, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 5 years and same should be prodused to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable incl taking down old unsv complete all as specified and directed. |
| 107 | Supply & fixing in repairs PVC rectangular blocks, of size 100mm x 100mm x 50mm deep. Modular/ Normal for mounting, switch, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with closed recessed, designed and cutting module for fixing switches/ sockets of any rating complete all as specified and directed. |
| 108 | All as per Srl item No. 107.00 but size 175mm x 100mm x 50mm deep. |
| 109 | S&F in replacement hylum sheet cover 2.6mm thick of size 10 x 10 cm (4\\" x 4\\") white in colour Incl cuttings module suitable for fixing switches/ sockets/ fan regulators etc. of any rating complete all as specified and directed. |
| 110 | All as per Srl item No. 109.00 but size 10 x 15 cm (4\\" x 6\\") |
| 111 | All as per Srl item No. 109.00 but size 15 x 20 cm (6\\" x 8\\") |
| 112 | All as per Srl item No. 109.00 but size 20 x 25 cm (8\\" x 10\\") |
| 113 | All as per Srl item No. 109.00 but size 25 x 30 cm (10\\" x 12\\") |
| 114 | Taking down carefully point wiring of any type complete for light, fan, bell, socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories including making good disturbed surface to match the existing surface complete all as specified and directed. |
| 115 | M&L for Point wiring for one light/ fan/ bell point controlled by one switch with PVC insulated FRLSH, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into with and including PVC casing-capping/ existing not less than 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed steel concealed terminal boxes of reqd size made out of 1.2mm thick sheet and covered with 2.8mm thick plastic laminated bakalite (hylam) ISI marked sheet suitable for switches/ sockets/ regulators complete all as specified and directed. |
| 116 | All as per Srl item No. 115.00 here in before but one point for socket outlet 5 Amp on independent board. |
| 117 | All as per Srl item No. 115.00 here in before but one point for socket outlet 5 Amp SAME BOARD. |
| 118 | All as per Srl Item No.115.00 above, but with FRLSH cable 2.5 Sqmm stranded copper conductor FRLSH with 2.5 Sqmm copper conductor earth wire for switch/ socket outlet 5 pin,15 Amps multipurpose on independend board complete all as specified and directed. |
| 119 | Supply & fix in repair Recessed mounted LED panel slim, compact, aluminium die castedge lite panel of 15 W round/ square shape with premium diffuser to ensure glare free & even distribution of light ceiling cut out size (180 x 180)mm, complete with electric connection incl taking down old unsv complete all as specified and directed by Engr-in-Charge. |
| 120 | S & F of TPN DB with provision for MCB TPN as incomer and SP MCBs as outgoing made of steel sheet phosphatised powder coated with bus bar, neutral link earth bar and DIN Rail having IP 42-IK 09 with metal door capacity 4-ways 415 V, connection with aluminium/copper lugs including civil/ plastering work for make up good the disturbed surface matching with existing surface including taking down old u/s complete all as specified and directed. |
| 121 | S&F (in replacement) MCCB 4 pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 100 to125 Amps rating, 16 KA breaking capacity including taking down old u/s complete all as specified and directed. |
| 122 | Supply and fix in repair double door SPN DBs 8 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete all as specified and directed. |
| 123 | Supply and fix in repair double door SPN DBs 12 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete all as specified and directed. |
| 124 | S & F in repair MCB SPN 6 to 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed. |
| 125 | S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed. |
| 126 | S&F in repair MCB SP 240 volts 40 to 63 Amps, 10 KA breaking capacity, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed. |
| 127 | S&F in repair MCB triple pole & neutral 63 Amp, 415 volts, 'C' series' 10 KA breaking capacity & connection complete all as specified and directed. |
| 128 | S&F in repair for energy saving recess mounted luminaire 36 W, Slim type (Edge-lite type) incl LED Driver, high efficiency, Ultra modern designed LED Luminaire which provides soft- glare free light and symmetrical illumination, suitable for Armstrong/ Grid ceiling of 600 x 600mm incl required suitable size of ceiling cut out, incl Provn of three core cable of copper conductor of size 1.5 Sqmm, making necessary electric connetion from ceiling rose to fitting terminal, fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all fixing arrangement incl taking down old unsv complete all as specified and directed. |
| 129 | S&F in replacement 3 pin plug-top, 15A, 240, beckelite, heavy duty suitable for 16 Amp socket outlet complete all as specified and directed. |
| 130 | S&F in replacement 3 pin plug-top, 5A, 240, beckelite, heavy duty suitable for 5 Amp socket outlet complete all as specified and directed. |
| 131 | S&F in repair PVC insulated cable three core Copper conductor of size 1.50 Sqmm, covered with round insulation complete all as specified and directed. |
| 132 | Supply in repair flexible PVC conduit pipe suitable & used for cover/ laying electrical wiring etc. of size 25mm dia complete all as specified and directed. |
| 133 | M&L for Overhauling/ servicing of defective/rusted ceiling/ Exhuast fan of any sweep by removing U/S parts by unscrewing bolts and nuts including winding of the fan, change of PVC exhaust fan motor and blades, repair/ replacement of defective parts, painting of the complete fan with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter and providing three core flexible copper cable for connection from ceiling rose/ connector complete all as specified and directed. |
| 134 | S&F in repair Decorative Post top for 360 degree indirect light 40 watts (Gate Light) with IP 65 Protection gate light (Prismatic), made up of high grade Resistant to Impact and corrosion, and Glare free and better Uniformity with all necessary fixing arrangement including connection complete all as specified and directed. |
| 135 | M&L for Sub main wiring with two runs of single core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia including one run of PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall including taking down old sub main wiring, complete all as specified and directed.Note:- Two runs of 4.00 Sqmm cable, one run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit. |
| 136 | M&L for scubbing out old paint, rust etc from 9/11 mtr steel tubular pole of any size including cross arms, brackets and anti climbing divices and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of pole structure and writing pole number with white paint on black base complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail