| 1 | M&L for preparation of old decorated plastered surfaces of walls and applying one coat of white wash complete all as specified and directed. |
| 2 | M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 3 | M&L for Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 4 | Preparation of old painted wooden surface of any description over 10 cms widths or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 5 | Preparation of old painted steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 6 | M&L for preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying two coat of distemper oil emulsion over one coat of wall care putty incl complete removal of existing treatment complete all as specified and directed. |
| 7 | S&F in repair plastic water closet seat cover for EWC white closed pattern with flat bottom and cover and mild steel chromium plated hinging device complete all as directed. |
| 8 | S&F in repair CP health faucetHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 9 | S&F in repair Brass CP mixer Pillar cock for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 10 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 11 | S&F for Curtain Rails, mild steel, chromium plated with fixing brackets, stops, rollers etc as in repairs complete all as specified and directed. |
| 12 | S&F in repair of angle valve(stop valve) 15 mm dia CP fancy type, with long screwed shank and cup, cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed complete all as specified and directed. |
| 13 | S&F in repair of 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building boards or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed. |
| 14 | S&F in repair cabinet mirror of minimum size of 400 mm x 550 of approved make complete all as specified and directed. |
| 15 | S&F in repair 15mm Bib tap brass chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 16 | S&F in repair grating doom 100mm dia of PTMT (Minimum weight 5gms) complete all as specified and directed. |
| 17 | S&F in repair 32 mm dia PVC waste pipe of 850mm length for Sink/WHB complete all as specified and directed. |
| 18 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed. |
| 19 | S&F in repair Chromium plated shower roses 125mm size with swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 20 | S&F in repair wall mixer swan neck, cast copper alloy with capstan head, chromium plated screwed down, high pressure with or without lettered \\"hot\\" or \\"cold\\" with long screwed shank and fly nuts screwed for iron pipe of 15mm bore complete all as specified and directed. |
| 21 | S&F in repair Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover flush pipe fixed as in repair complete jointing, connecting and making good the disturbed surfaces complete all as specified and directed. |
| 22 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 23 | M&L for 10mm thick cement plaster in cement mortar 1:6 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc complete all as specified and directed. |
| 24 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 25 | M&L for Non- skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 including takingdown existing complete all as specified and directed.Note : Item may be repaired to be done in patches also. |
| 26 | M&L in repair glazed coloured ceramic tiles in vertical surface 450x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match existing surface including 10mm thick backing coat in cement mortar 1:4 complete all as specified,including takingdown existing complete all as specified and directed.Note : Item may be repaired to be done in patches also. |
| 27 | Dismantaling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 28 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 29 | All same as per item No. 28 above but except sheeting (any thickness) complete all as specified and directed . |
| 30 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 31 | All same as per item No. 30 above but except sheeting (any thickness) complete all as specified and directed . |
| 32 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) and removing rubbish complete all as specified and directed. |
| 33 | M&L for PCC TypeD2 1:4:8 (using 20 mm graded stone aggregate) in foundations, filling or as in sub base and mass concrete complete all as specified and directed. |
| 34 | M&L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes complete all as specified and directed. |
| 35 | M&L for virified ceramic tiles dark shade 10 mm thick (square/ rectangular) polished area of each tile n.exc 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match existing flooring complete all as specified and directed. |
| 36 | M&L for 75mm thick, PCC 1:3:6, Type C-2, using 20mm graded stone aggregate as in Plinth protection etc, laid in alternate pannel, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | M&L for providing, cement concrete type B0 1:2:4 (12.5mm graded stone aggregate stone) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, Chajjas, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, neelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 38 | M&L for screed bed or bedding layer of mortar 10 mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and directed. |
| 39 | M&L for glazed ceramic coloured / printed tiles 450mm x 300mmx7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles complete all as specified and directed. |
| 40 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/ slabs/ blankets, any thickness including cover fillet complete all as specified and directed. |
| 41 | S&F for powder coated GI Snap grid system of size 605 X 605 mm for ceiling fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the following sections complete all as specified and directed:- (i) Maint Tee 28mmx24mmx0.3mm thick.(ii) Cross Tee 28mmx24mmx0.3mm thick.(iii) Wall angle 24mmx24mmx0.3mm thick. |
| 42 | S&F for 4 mm thick designer ceiling (E-board classic tiles) for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or GI sanp grid or withstaples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed. |
| 43 | Dismantling timber scantlings 40 Sqcm and over in section, in Unframed work complete all as specified and directed. |
| 44 | M&L for Timber framed and fixed second class hard wood clean swan second class hard wood in scantlings complete all as specified and directed. |
| 45 | Dismantling of wrought iron or mild steel work of any description not otherwise provided etc complete all as specified and directed. |
| 46 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe 410-W (Gde E250) quality-A including distance pieces, cleats etc complete all as specified and directed. |
| 47 | S&F in repair vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests with 'P' or 'S' trap, connection to trap, and to flushing pipe, anti-syphonage pipe etc alongwith making good to floor complete all as specified and directed. |
| 48 | S&F in repair PVC low level flushing cistern, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets, connection to pipe complete all as specified and directed. |
| 49 | M&L for sunken floor treatment as follows as per S. No. (i) to (v) :- The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.(i) Demolition of concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaned the sunken potion incl vertical wall surface complete as directed.(ii) Top of RCC salb in sunken portion including peripheral beams shall be plastered with 15 mm thick cement and sand mortar (1:3) using approved water proofing compund @3% by weight of cement finished even and smooth without using extra cement and curved adequately and allowed to dry. (iii) Two coats of epoxy resin / polymer modified cementaticious coating like brush bond of Fosroc or equivalent both on floor and walls /beams shall be applied as per manufacturer instuctions.(iv)slabs to be given 1:20 slope outward with 25 mm GI pipe spout with 300 mm projection beyond outer surface of wall complete all as specified and directed.(v) After the surface is passed by the Eng- in- charge for water tightness by flooding for 72 hrs the same shall be filled with lean concere (1:4:8) using type B-1 aggregate , up to the required depth. Surface surrounding to WC Pan shall however be of cement concrete as specified here-in-before. |
| 50 | S&F in repair 110mm bore PVC (SWR) soil, waste & vent pipe single socketed in any length with runbber ring joints & fixed to walls or in floor complete all as specified and directed. |
| 51 | S&F for 110mm bore PVC (SWR) bends of any radius with opening gate type complete all as specified and directed. |
| 52 | S&F in repair 75 mm bore PVC (SWR) soil, waste & vent pipe single socketed in any length with runbber ring joints & fixed to walls or in floor complete all as specified and directed. |
| 53 | S&F for 75mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 54 | Dismatling & Disconnecting old existing PVC water tank exc 250 Ltr and n.exc 500 Ltr and removing to store complete all as specified and directed. |
| 55 | S&F for Rotational moulded PVC water storage tanks 500 Ltrs capcity Three layer (cylindrical vertical with closed top) hoissted and including S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod of 20 mm bore & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) fixed in position complete all as specified and directed. |
| 56 | S&F for 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 57 | Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15mm bore complete all as specified and directed. |
| 58 | S&F for 15mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 59 | Taking down existing unserviceable roof treatement of any description including cement plaster, any thickness from roof surface, cleaning of roof surface and preparing it for further treatement and removing the debries/ rubbish material from site complete all as specified and directed. |
| 60 | Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) of minimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer on 15mm thick plastered sufaces layer in cement mortar 1:4 with water proofing compound (WPC )@3% by weight on concrete surface roof / parapet, over lap of minimum 75 mm on longitudinal direction and 100 mm on the transverse direction by thermo-fused torch flame application method and top surfaces to be treated with two coat of aluminium paint @0.15 Kg/Sqm all as per manufacturers instructions as complete all as specified and directed. |
| 61 | M&L for rendering 15 mm thick on fair faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement complete all as specified and directed. |
| 62 | M&L for rendering 15 mm thick on fair faces of brick work or stone masonry or concrete surfaces in cement mortar 1:6 and finished fair and even without using extra cement complete all as specified and directed. |
| 63 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished smooth and even in ceiling without using extra cement complete all as specified and directed. |
| 64 | S&F in repair 6 mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work or in roof for monkey protection complete all as specified and directed. |
| 65 | Demolition of PCC around floor trap and dismantling existing floor trap and Supply & Fix PVC floor/Nahani trap in existing pipe and embedding in cement mortar 1:1 including lowering or raising with vertical piece with PVC pipe for jointing trap and fixing gratings at true level of floor complete all as specified and directed. |
| 66 | Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) of minimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer complete all as specified and directed. |
| 67 | M&L for dismantling of PVC (SWR) Pipe any radius and any position complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |