| 1 | Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 2 | M & L for Pre - cast cement concrete 1:3:6 type C-1, (20mm graded stone aggregate) block masonary with solid blocks built in cement mortar 1:6 all as specified and as directed. |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. |
| 4 | M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified. |
| 5 | M&L for 20mm thk granite stone machine cut (table rubbed and polished) bedded and jointed with grey cement slurry nd pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing rounding to edges of granite stone etc complete all as specified. |
| 6 | M&L machine cut kota stone slab flooring 20-25mm thick over and including cement screed based 15 mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting polishing and rubbing complete. |
| 7 | Dismantling wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness incl. cover fillets and alum snip grid. |
| 8 | S & F Anodised Alu. Snap grid 605x605 mm frame wk for false ceiling and providing 9mm th Acoustical board/tiles for insulation 60x60 cm in size, fixed in celing with screws to frame work or with staples on snap grid including hangers 3 mm dia G.I. ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long all as specified |
| 9 | Dismantling floor hearth or wall tiling incl cement mortar bedding/plaster (but not backing) and removing rubbish off the premises etc complete all as directed. |
| 10 | M&L for joint free Non-skid coloured Ceramic tiles of size 300 x 300 x 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified. |
| 11 | M & L for joint free ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 12 | All as per item No 11 above but on skirtings incl 10 mm th rendering in CM (1:3) complete. |
| 13 | M&L for vitrified ceramic light coloured tiles 8 to 10mmthk (square/rectangular) polished area of each tile 0.30 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm th screed bed in CM 1:6 complete. complete all as specified and directed. |
| 14 | All as per item No 13 but on skirting over 10 mm th rendering in CM 1:3 complete. |
| 15 | M&L for glazed coloured ceramic tiles 350 mm x 250mm/450mmx300x7 to 7 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement incl backing coat 10mm thick in CM 1:3 all as direced. |
| 16 | Demolition of concrete ( unreinforced ) in ground floors and paving nexc 15 cm thk (below or above ground level) |
| 17 | M & L 75 mm thk Cement conc type C-2, 1:3:6 (40 mm gr agg) as in plinth protection finished even and fair . |
| 18 | M & L PCC type D2 1:4:8 (40 mm Gr. Agg ) 75mm thick as in sub base complete all as specified. |
| 19 | M&L for laying machine pressed precast concrete interlocking reflective coloured pavers block (glossy finish) any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming all as specified. |
| 20 | M& L Chequered Cement Concrete Tiles (glossy finish ) 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 .complete all as specified. |
| 21 | Taking down cement plaster of any description of brick or stone wall etc incl racking out joints and hacking for key, scrubbing down with water etc complete |
| 22 | M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete walls finished even and smooth w/o using extra cement. |
| 23 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or conrete surfaces finishing the surfaces even and smooth without using extra cement. |
| 24 | M&L for preparing new plastered surfaces & applying two coats of cement base paint on walls. |
| 25 | M&L for preparation of new surfaces plastered or unplastered new surfaces & applying two coats of oil emulsion distemper on walls over a coat of primer. |
| 26 | M & L preparing old decorated plastered or unplastered surfaces of walls including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of painted surfaces applying one coat of oil emulsion distemper complete all as specified and directed. |
| 27 | M & L preparing old decorated plastered or unplastered surfaces of walls including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of painted surfaces applying one coat of cement paint complete all as specified and directed. |
| 28 | M&L One coat of synthetic enamel paint on old painted steel surfaces over 10 cm width or girth incl prepration of surfaces complete |
| 29 | M & L for Preparing old decorated plastered or unplastered surfaces of ceiling including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying one coat of white wash complete all as specified. |
| 30 | M&L for prepartion of old plastered surface of wall applying one coat of weatherproof acrylic emulsion exteroir grade paint on external surfaces complete all as specified. |
| 31 | Dismantling asbestos cement (corrugated/ semi corrugated etc) sheet in roof covering complete all as specified and directed. |
| 32 | Dismantling MS works of any Desc. Not otherwise provided for |
| 33 | S&F Tubular Sections as in main cross beams , hip and jack rafters; purlins, where connected to common rafter , posts etc. conf to Fe-410-w(gdeE-250 quality-A) |
| 34 | M &L for MS work as in wind tie or any other work incl cutting, drilling holes etc. |
| 35 | S & F 0.5mm thick corrugated pre painted / coloured galvalume sheet in roofing fixing all as per manufactures instructions with all fittings and accessories etc complete. |
| 36 | S&F for 0.60 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 as directed by engr-in charge. |
| 37 | All as per item No 36 but plain sheet fix in valley gutter / ridge |
| 38 | M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer. |
| 39 | Dismantling of PVC water tank of capacity exc 500 litre and n. exc 1000 litre and complete all as specified and directed. |
| 40 | Dismantling of PVC water tank of capacity exc 250 litre and n. exc 500 litre and complete all as specified and directed. |
| 41 | S&F rotational moulded Polythene (HDPE) double layer water tanks, cylindrical & vertical type 500 Litres capacity hoisted and fixed in position including provision of 20mm/15mm dia. spouts for connecting inlet, outlet, over flow and washout pipes. |
| 42 | All as per item No 41 but 1000 litres. |
| 43 | Disconnecting existing PVC water tanks of capacity exc 250 but n.exc 500 litres, setting aside (or lowering if required) for refixing complete all as specified and as directed. |
| 44 | Fixing only water tanks of capacity 500 Ltr incl cleaning and removing all scale and dirt etc from tanks and mouth of circulating pipes. |
| 45 | Disconnecting existing PVC water tanks of capacity exc 500ltr but n.exc 1000 litres, setting aside (or lowering if required) for refixing complete all as specified and as directed. |
| 46 | Fixing only water tanks of capacity 1000 Ltr incl cleaning and removing all scale and dirt etc from tanks and mouth of circulating pipes. |
| 47 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame)exc 1.5 sqm but n.exc 4 sqm each and removing to store. |
| 48 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n'exc 1.5 Sqm each. Please Enable Macros to View BoQ information |
| 49 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n'exc 1.5 Sqm each. Please Enable Macros to View BoQ information |