| 1 | Earthwork in excavation of foundation trenches in ordinary in soil (vide classification od soil item -A) and disposal of excavated earth as obtained to a distance upto 50M including all lift, leveling ramming the foundation trenches, removing roots of tree shurbs all complete as per approved design, building specification and direction of E/I. (5.1.1.) |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) (5.1.2.) |
| 3 | Providing coarse clean sand filling in foundation trenches and plinth including ramming and watering in layers not exceeding 150mm thick with all leads & lifts including the cost of all materials, labour, royality, & taxes all complete as per building specification and direction of E/I (5.1.10) |
| 4 | Providing designation 75A one brick flat soling joints filled with local sand including the cost of watering taxes royality all complete as per building specification and direction of E/I. (5.6.1) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) (5.3.1.5.) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1.) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (5.3.10.) |
| 8 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (5.2.3.) |
| 9 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (5.3.5.) |
| 10 | Providing designation 75A brick in C.M. (1:6) in Superstructure with approved quality of clean sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints , cost of screening materials raking out joints to 15 mm depth , curing , taxes and royality all complete as per building specification and direction of E/I (5.2.11.) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.11.) |
| 12 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.1) |
| 13 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.3.) |
| 14 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.5.) |
| 15 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.6.) |
| 16 | Centering and shuttering including strutting, propping etc. and removed pf from for Foundations, footing, bases of columns, etc. for mass concrete. (5.3.17.19.) |
| 17 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.12.) |
| 18 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (5.5.29.) |
| 19 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. (5.6.7.) |
| 20 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.14.) |
| 21 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.13.) |
| 22 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) (5.8.41.) |
| 23 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (5.8.45.) |
| 24 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.6.) |
| 25 | Providing 12 mm thick cement plaster in C.M. (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all lead and lift of water , scaffolding taxes and royality all complete as per buildig specification and direction of E/I (5.7.3 ) |
| 26 | Providing 12 mm thick cement plaster in C.M. (1:3.) with clean coarse sand of F.M 1.5 including screening, curing with all lead and lift of water , scaffolding taxes and royality all complete as per buildig specification and direction of E/I (5.6.10.) |
| 27 | Providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete. do all complete job as per direction of EI (DSR 13.80) |
| 28 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. (5.8.21.) |
| 29 | Supplying, fitting and fixing C.A.R.W.D. Pipe with necessary strips spikes, bends, shoes etc. Including cost of carriage, all complete, as per building specification and direction of E/I. 75mm dia |
| 30 | Providing Tor steel reinforcement of 8mm, 10 mm and 12 mmmm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.4) |
| 31 | Providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (a) |
| 32 | Providing Tor steel reinforcement of 8, 10 mm and 12 mm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (b) |
| 33 | Providing Tor steel reinforcement of 8, 10 mm and 16 mm dia bar as per approved design and drawing TMT Fe 500 (Only vaild for Tata (tiscon), Sail,JSPL, Electrosteel Steel Ltd. Bokaro and Viraz (RINL)all complete as per building specification and direction of E/I (5.5.5) (c) |
| 34 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (5.3.8.) |
| 35 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. (5.10.33.) |
| 36 | Point wiring in PVC conduit with Modular type switch wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5 sqmm FRPVC insulated copper conductor single core cable in surfface/ recessed PVC conduit with modular type switch modular plate suitable of GI box etc as required (1.1.1) EnergyGroup -(C) |
| 37 | Power plug widng in PVC conduit (2 x 4 sq. nun) : Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loop carthing etc as required. (1.5.)Energy |
| 38 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (1.21) Energy20 mm. P.V.C. Conduit. |
| 39 | 25 mm. P.V.C. Conduit |
| 40 | S/F Piaoo type switch/ socket : lSupptyrng and fxing of following piano type switch / socket on the existing lswitch box / cover including connections etc. as requted.1.23.5/6 amps, one way switch |
| 41 | 5/6 amps, one way switch |
| 42 | S/F PVC/G.I. boxes : Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.126 mm x277mmx 6lmm deep/ (6\\" x 12\\") |
| 43 | SIF S.P. MCB DB : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.8.2 + 8 way double door |
| 44 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required (1.7)2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire (1.7.1) |
| 45 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (1.7.2) |
| 46 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire (1.7.4) |
| 47 | Supplying and Fixing Batten holder: Supplying and fixing Batten/Angle holder including connection etc as required.(1.34) |
| 48 | S/F ceiling rose : lsupplying and fxing 2 pn 5 amp. Ceiling rose on the existing junction box/ l*oo\\"n block including connection etc. as required. (1.33.) |
| 49 | Carraige of matterials :-Cement - |
| 50 | Steel - |
| 51 | Sand- |
| 52 | Brick- |
| 53 | Stone chips - |
| 54 | Add 18% G.S.T |
| 55 | Add 1% Labour Cess Please Enable Macros to View BoQ information |