| Sl. No. | Item Description |
| 1 | Bill of Quantity for Electrical |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in recessed medium class PVC conduit as required. |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in recessed medium class PVC conduit as required. |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 6 sq. mm + 1 X 6sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with 4 X 4 sq. mm + 2 X 4 sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in recessed medium class PVC conduit as required. |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with 4 X 16 sq. mm + 2 X 6 sq. mm wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in recessed medium class PVC conduit as required. |
| 11 | Supply and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fire tinned copper braid and protected with PVC sheath in the existing surface recessed steel/PVC conduit as required. |
| 12 | Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | Supplying and fixing TV Antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | Supplying and fixing 1 or 2 Module (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 19 | Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board including making connections etc. complete in all respect. |
| 20 | Numbering of ceilling fan/ exhaust fan/ light fitting as required |
| 21 | Installation of exhaust fan Upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 22 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 23 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 24 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 25 | Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 26 | Supplying and fixing of 4 ways (4+12) surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. |
| 27 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for 8 way TPN , sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 28 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel,Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 29 | Supplying and fixing single pole 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 31 | Supplying and fixing 40 Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 32 | Supplying and fixing 63 Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying and fixing 100 Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Supplying and fixing 40 Amp rating, four pole, (three phase and neutral) TPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Supplying and fixing 63 Amp rating, four pole, (three phase and neutral) TPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 36 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 37 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 38 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 39 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 40 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 41 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 42 | SITC of LED Down lighter (SMD Type) (System lumen efficacy ≥135 lm/Watt). (Round/ square/ Rectangular) SMD Type of 12-15 watt body material and construction as per IS : 10322 with driver Operating voltage AC 140-270 Volt, frequency 50/60 hz, internal surge protection of 2.5 KV, THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours, Complete in all respect i/c external connections with Minimum 5 year OEM warranty. All specifications as per DSR (E&M)- 2025 item 8.3.3 |
| 43 | SITC of LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt). (Round/ square/ Rectangular) COB Type of 12-15 watt body material and construction as per IS : 10322 with driver Operating voltage AC 140-270 Volt, frequency 50/60 hz, internal surge protection of 2.5 KV, THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours, Complete in all respect i/c external connections with Minimum 5 year OEM warranty. All specifications as per DSR (E&M)- 2025 item 8.5.3 |
| 44 | SITC of LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt). Type of 15 watt body material and construction as per IS : 10322 with driver Operating voltage AC 140-270 Volt, frequency 50/60 hz, internal surge protection of 2.5 KV, THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours, Complete in all respect i/c external connections with Minimum 5 year OEM warranty. All specifications as per DSR (E&M)- 2025 item 8.8.1 |
| 45 | SITC of LED surface mounted Batten light (System lumen efficacy >135 lm/Watt) 22-24 watt body material and construction as per IS : 10322 with driver Operating voltage AC 140-270 Volt, frequency 50/60 hz, internal surge protection of 2.5 KV, THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours, Complete in all respect i/c external connections with Minimum 5 year OEM warranty. Powder coated die cast /Extruded aluminium Body. All specifications as per DSR (E&M)- 2025 item 8.11.1 |
| 46 | SITC LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy >135 lm/Watt). 90 watt with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz,, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, with Minimum 5 year OEM warranty. Smart inbuilt controller shall have following features. 1.Control and monitor LED luminaries with bi directional control( Status, Fault, Alarm, dimming level, wattage, energy) 2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours 3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR). 4. Wi-Fi LoRA/ Zigbee/ Powerline with ethernet network based IOT feature as per site requirement or engineer in charge. 5. should be controlled through auto/ manual 6. Programmable level of not less than 48 different light intensity settings, 7. inbuilt repeater & relay signals function to other controllers. All specifications as per DSR (E&M)- 2025 item 8.20.4 |
| 47 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole/wall including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 48 | Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/ RGBNW/ RGBA/ RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of 50 Watt Luminaire should have efficacy of minimum 35 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options..All specifications as per DSR (E&M)- 2025 item 19.1.1 |
| 49 | SITC of single LED decorative light with wall bracket including 3 to 6 Watt LED lamp including coneections etc. complete in all respect. |
| 50 | Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. |
| 51 | Supply of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 52 | Supply of 300mm sweep ventilating (Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. |
| 53 | Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. |
| 54 | Supply and fixing of crimping, solderless, copper tin electroplated lugs of Dowells/Ismai lmake suitable for 1.5 sq.mm to 2.5 sq.mm cables, including tapping with insulating tape, complete in all respect. Sl No 1129 |
| 55 | SITC of 1200mm ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM, THD less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections. |
| 56 | SITC of 1400mm ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM, THD less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections. |
| 57 | Supplying and laying of 50 sq mm 3-1/2 core aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade on surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 58 | Supplying and laying of 120 sq mm 3-1/2 core aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top suitable size or as directed by the Engineer-In-charge, complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 59 | Supplying and making 3½ X 50 sq. mmsize cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. |
| 60 | Supplying and making 3½ X 120 sq. mmsize cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. |
| 61 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 62 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 63 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 64 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 65 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 66 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. Incoming 200 Amp Outgoing 100 Amp-02 Nos |
| 67 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules.Sl No. 1136 |
| 68 | SITC of 24 port Layer 2 indoor Network non PoE Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack,on all Gigabit Ethernet ports and on all GE RJ-45 access ports. All Specification as per CPWD DSR (E&M)-2025 item 39.3.2 |
| 69 | SITC of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client. complete as required. All Specification as per CPWD DSR (E&M)-2025 item 39.8 |
| 70 | Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 71 | SITC of Copper Patch Cords of length 1m (3ft) CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 72 | SITC of Copper Patch Cords of length 3m (10ft) CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 73 | SITC of CAT6 copper Information Outlet (IO) with face plate as per site requirment. Complete as required |
| 74 | SITC of RJ45 connector for CAT6 cables. RJ45 modular plug supports 4 twisted pairs, 8 position 8 connectors. Housing PC etc. Complete as required |
| 75 | SITC of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D Standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of Cable |
| 76 | SITC of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D Standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 2 Run of Cable |
| 77 | Supplying and fixing of 6U size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 78 | Supply & Fixing of medium class 25 mm PVC conduit along with accessories in suface/recess including cutting the wall and good finish the same complete. |
| 79 | Supplying and fixing 1 or 2 modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 80 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 81 | Supplying, installation, Testing & Commissioning of 3KVA capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. All specifications as per DSR (E&M)- 2025 item 26.1.2 |
| 82 | SITC of 3CO, 12 Extensions EPABX system having features of call forward call pickup, CLI transferable/ internal CLI, DTMF/FSK junctions line operating on 220 Volts single phase AC. Comlete in all respect. |
| 83 | Supplying, Installation, Testing & Commissioning of Analog phones having advanced feautres like 16 digit LCD display, 2 way speaker, caller ID, cordless, redial, and number storage facility etc. complete as required. |
| 84 | Supplying, Installation, Testing & Commissioning of Analog phones having standard feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required. |
| 85 | Supplying and drawing 01 pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 86 | Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 87 | Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 88 | Supplying and fixing 1 or 2 modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 89 | Supplying and fixing of 6U size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 90 | SITC of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 91 | SITC of manual call boxes of MS construction in surface /recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 92 | SITC of response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 93 | SITC of fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc.complete as required. |
| 94 | SITC of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, inter connections etc complete as required. Each 52258.00 6 zone panel for fire alarm system |
| 95 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 96 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 97 | SITC of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection 450 lpm at 35 m Head All specification as per CPWD DSR(E&M)-2025 serial 27.4.2 |
| 98 | Providing, laying, testing & commissioning of 'C'class heavy duty 80 mm dia MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 99 | Providing, laying, testing & commissioning of 'C'class heavy duty 100 mm dia MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 100 | Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel |
| 101 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia |
| 102 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :100 mm dia |
| 103 | Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 104 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 105 | Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 106 | Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) |
| 107 | Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 Mtr |
| 108 | Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) |
| 109 | Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe |
| 110 | Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 111 | Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. |
| 112 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 113 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 114 | Supplying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. size 25 sq mm x 3-1/2core size |
| 115 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 25 sq. mm (28mm) |
| 116 | SITC of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 117 | SITC of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 118 | Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. |
| 119 | S/L of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules |
| 120 | SITC of Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2. |
| 121 | SITC of 1.6 mm thick M.SHose Box with glass fronted door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor) .750x600x250 mm |
| 122 | Providing and placing on terrace (at all floor levels) polyethylene 10000 Ltr water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 10000 Ltr Tank |
| 123 | Providing and fixing 50 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall |
| 124 | Supplying, Installation, Testing and Commissioning of fixing of 50mm dia. Gun metal gate valve (Screwed type) on the existing pipeline, including testing & Commissioning etc. complete as required.. |
| 125 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal Horizontal Non Return valve ( screwed type ) on the existing pipeline, including testing & Commissioning etc. complete as required. |
| 126 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.3 Core 2.5 Sq mm Flat Cable |
| 127 | SITC of Subemersible Pump 3HP, 415V, 50Hz, min. 15 STG, 4-inch diameter submersible pump with a 50mm (2\\") discharge outlet and a water-filled motor. Complete in all respect. |
| 128 | SITC of Starter Panel, for capable of Operation of Submercible Pump or capable of start up to 5 HP pump motor shall include necessary lamps indications, ammeters and, voltmeter, controlling push button with overload protection, single phase preventor and shall be wall mounted type, suitable for operation on 415V, 3 phase, 50Hz Ac Supply.Complete in all recpect. |
| 129 | SITC of Starter Panel, Fabricated out of 1.6mm/2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process for capable of Operation of 450 LPM Terrace Pump or capable of start up to 10 HP Terrace Pump and having provision for automatic starting by pressure switches, control mounting shall include necessary lamps indications, ammeters for motor full load current with CTs and selector switch, auto/manual selector switch, voltmeter with selector switch, controlling push button fully automatic Star/Delta starter with overload protection, current sensing type, single phase preventor. The panel shall be duly painted with protective anticorrosive and shall be foot mounted/wall mounted type including all accessories. suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required . Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail