Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 2 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 2 | Excavation for foundation in hard murum including removing the excavated materials upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. By Manual Means (Lift from 1.5 metre to 3.0 metre)Item / Page No : 7 / 154Specification No : Bd.A.2Spec. Page No : 259 |
| 3 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.Item / Page No : 36 / 157Specification No : Bd.A.10Spec. Page No : 262-263 |
| 4 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : Bd.A.11Spec. Page No : 263-264 |
| 5 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 6 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3, B-7Spec. Page No : 298, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 7 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : Bd.F.5, B-7Spec. Page No : 300, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 8 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : Bd.F.6, B-7Spec. Page No : 300-301, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 9 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : Bd.F.8, B-7Spec. Page No : 302-303, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 10 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 11 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 12 / 198Specification No : Bd.G.3, Bd.G.5Spec. Page No : 314, 315Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 12 | Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 13 / 198Specification No : Bd.G.3, Bd.G.5Spec. Page No : 314, 315Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 13 | Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire, excetra complete. (For Ground Floor)Item / Page No : 26 / 210Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 14 | Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 15 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : Bd.L.7Spec. Page No : 369Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 16 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For Ground Floor)Item / Page No : 15 / 210Specification No : Bd.L.10Spec. Page No : 370 |
| 17 | Providing waterproofing in water closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortar 1:3 on vergin concrete slab with waterproofing compound at the rate of 1 kilogram per bag of cement laying brick bat coba of required thickness in cement mortar 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in centimetre mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing, excetra complete. (For Ground Floor)Item / Page No : 26 / 208Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 18 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 205Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in charge. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 19 | Providing water proofing treatment as per Indian Standard : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kilogram per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 centimetre overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kilogram per 10 square metre and finally spreading over it grit at the rate of 14.50 kilogram per 10 square metre including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper excetra complete. (For Ground Floor)Item / Page No : 17 / 207Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 20 | Providing and laying machine cut machine polished Kotah stone slabs 20 milimetre to 25 milimetre thick for treads and risers of steps and staircases with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 18 / 215Specification No : Bd.M.22Spec. Page No : 390Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 21 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 22 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 40 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 23 | Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 41 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 24 | Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 24 / 215Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 25 | Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 25 / 215Specification No : Bd.M.13Spec. Page No : 386Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 26 | Providing and fixing Manalore tiled roofing with class \\"AA\\" tiles including securing the last course of tiles near the eaves with steel flat 40 milimetre X 3 milimetre and 1.22 milimetre wire, fixing country teak wood sloping battens of 25 milimetre X 12 milimetre teak wood horizontal battens of 50 milimetre X 25 milimetre over the slopping battens, all iron work and coal tarring the battens, excetra complete. (excluding ridge and hip tiles) (For Ground Floor)Item / Page No : 2 / 233Specification No : Bd.R.2Spec. Page No : 450 |
| 27 | Providing and fixing Mangalore tile ridge and hip tiles of class \\"AA\\" including scaffolding if necessary, pointing with coloured cement mortar and curing, excetra complete. (For Ground Floor)Item / Page No : 3 / 233Specification No : Bd.R.3Spec. Page No : 450 |
| 28 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor)Item / Page No : 40 / 252Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 29 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor)Item / Page No : 68 / 259Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 30 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)Item / Page No : 9 / 246Specification No : Bd.T.34Spec. Page No : 499 |
| 31 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor)Item / Page No : 1 / 245Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 32 | Providing and applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scrapping, applying french polishing, scaffolding, if required, excetra complete. (For Ground Floor)Item / Page No : 9 / 222Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 33 | Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 34 | Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For Ground Floor)Item / Page No : 23 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 35 | Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor)Item / Page No : 34 / 212Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 36 | Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other materials as required, excetra complete. (For Ground Floor)Item / Page No : 24 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 37 | Design, supply, fabrication and fixing of stainless steel non glare multilingual Braille (raised dots) entrance signage (1 feet X 1 feet) as per the approved design and make, indicating the name of the building. Having 1.2 milimetre thick stainless steel non glare blue coloured base plate with the universal accessibility symbol and upper case Sans Serif words of height 15 milimetre engraved on it along with the equivalent word/s written in Hindi using Devnagri script of height 15 milimetre in white colour. Grade 2 / Grade 1 Braille to be etched / engraved and be raised 0.5 milimetre above base plate. The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 milimetre from the finished ground / floor level, using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the Engineer in-charge.Item / Page No : 84 / 372Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 38 | Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including \\"S\\" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For Ground Floor)Item / Page No : 30 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 39 | Providing and fixing coloured glazed earthenware wash hand basin of 45 centimetre X 30 centimetre size including cold water piller tap / cold and hot water piller tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including poly vinyl chloride waste pipe and tap upto the outside face of the wall.Making good the damaged surface, testing excetra complete. (For Ground Floor)Item / Page No : 67 / 272Specification No : Bd.V.30Spec. Page No : 565 |
| 40 | Providing and fixing cromium plated 2 way bib cock with wall flange of approved make including necessary sockets / union nut, excetra complete as directed by Engineer in charge. (For Ground Floor)Item / Page No : 27 / 314Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge. |
| 41 | Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor)Item / Page No : 80 / 273Specification No : Bd.V.32Spec. Page No : 567 |
| 42 | Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and farme fixed in cement concrete Cover medium duty 140 kilogram with frame excetra complete. (using ARTIFICIAL SAND).Item / Page No : 12 / 275Specification No : Bd.V.43Spec. Page No : 574Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 43 | Providing and fixing poly vinyl chloride rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 milimetre to 2.7 milimetre confirming to Indian Standard : 13592-1992 including proper rain water receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall affixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete. (For Ground Floor)Item / Page No : 85 / 283Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 44 | Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor)Item / Page No : 54 / 280Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 45 | Providing and fixing on walls / celling / floor, 25 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)Item / Page No : 57 / 280Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 46 | Providing and fixing on walls / celling / floor, 50 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete. (For Ground Floor)Item / Page No : 60 / 280Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 47 | Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)Item / Page No : 52 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 48 | Providing and fixing 15 centimetre X 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.Item / Page No : 2 / 274Specification No : Bd.V.38Spec. Page No : 572 |
| 49 | Providing second class fly ash Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 14 / 198Specification No : Bd.G.7Spec. Page No : 316Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 50 | Providing and fixing mild steel grill railing weighing 15 kilogram per square metre with teak wood hand rail of size 75 milimetre X 60 milimetre and sill 75 milimetre X 25 milimetre and posts for verandah including fabricating, fixtures, erecting and painting the grill work with one coat of anticorrosive paint and two coats of oil paint and polishing the hand rail with French polish. (For Ground Floor)Item / Page No : 9 / 265Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 51 | Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete.Item / Page No : 12 / 294Specification No : Bd.W.7Spec. Page No : 586-587 |
| 52 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Liquid Limit and Plastic Limit for Earth Work using earth from Departmental Land1 Test per 1000.00 |
| 53 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail