| 1 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.50 sqm of any description complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.00 sqm of any description complete all as specified and directed. |
| 3 | Taking down shutters of any description exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and directed |
| 4 | Supply & Fixing for 35mm thick flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply & Fixing for 35 mm thick second class hard wood factory made glazed and skeleton shutters (two or three panel as directed by EIC), open rebated and prepared to receive glass, gauze etc (without sash bars), edge of framing plain chamfered of rounded, fitted with cut and mitred beads for securing glass etc. size of members of shutters shall be as specified in SSR Part I, section 8.20 (a) complete all as specified and directed. |
| 6 | Supply & Fixing 35mm thick factory made moulded PVC door shutter with 2, 4 or 6 raised panel design consisting of solid core single leaf flush shutter of 30mm thickness, lipped with 15mm (5mmx3) thick on one stiles and top rails & 10mm (5mm x 2) thick on other rail stiles and bottom rails, front face laminated with 2mm thick prelam or walnut colour PVC sheet in moulded design with 2, 4 or 6 raised panel and 2mm thick prelam or walnut colour PVC sheet on other side. PVC sheet having density 600kg/Cbm and should be termite proof, water proof & fire proof and fixing with the frame at site as per manufacturer specification and complete all as specified and directed. |
| 7 | Supply & Fixing PVC door frame of size 100mm x 45mm with a wall thickness of 5mm, made out of extruded 5mm prelam PVC sheet of density 600kg/Cbm, meter cut at two corners and jointed with 4 Nos of 150mm long brackets of 15x15mm MS square tube. The two vertical door frame to be reinforced with 40x20mm MS tube of 19 gauge through out the frame and fixing in opening as per manufacturer instruction and complete all as specified and directed. |
| 8 | Supply & Fixing in repair CP towel rail 600 mm long fixed with chromium plated brass screws and wooden /plastic cleats fixed complete all as specified and directed. |
| 9 | Supply & Fixing for aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples to alu door, wooden beadings to wooden doors complete all as specified and directed. |
| 10 | Supply & Fixing for extruded aluminium alloy handles 125mm size, fabricated type, anodised complete all as specified and directed. |
| 11 | Supply & Fixing for Aluminium, anodised, barrel tower bolts 150mm size of extruded section and fixed complete all as specified and directed. |
| 12 | Supply & Fixing for Aluminium alloy, anodised, sliding door bolt 300mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 13 | Supply & Fixing for floor door stopper of Aluminium alloy body two leg of 75mm and overall length of 90 mm complete all as specified and directed. |
| 14 | Supply & Fixing in repair 100mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed. |
| 15 | Supply & Fixing for 100mm MS single action spring hinge with steel wire spring, stove enamelled black complete all as specified and directed. |
| 16 | Supply & Fixing in repair extruded aluminium alloy handles 125mm size, fabricated type, anodised complete all as specified and directed. |
| 17 | Supply & Fixing in repair Aluminium, anodised, barrel tower bolts 150mm size of extruded section and fixed complete all as specified and directed. |
| 18 | Supply & Fixing in repair Aluminium alloy, anodised, sliding door bolt 300mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 19 | Supply & Fixing in repair floor door stopper of Aluminium alloy body two leg of 75mm and overall length of 90 mm complete all as specified and directed. |
| 20 | Supply & Fixing in repair aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, wooden beadings to wooden doorscomplete all as specified and directed. |
| 21 | Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & Fixing for Pressed steel frames size 125 x 25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed. |
| 23 | Supply & Fixing for Pressed steel frames size 105 x 25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Supply & Fixing for powder coated anodised aluminium frame / track or shutters for windows, ventilators etc. with one or more rebates including joining cleat for fixing etc. fixed or sliding type / louvered window or ventilator without sash bar, including necessary joining & fixing, cleats, glazing clips, rubber packing, soundproof window sealing strips, anodised aluminium snap beading, screws and locking arrangement etc complete all as specified and directed. |
| 25 | Material & Labour for aluminium anodised powder coated grill manufactured by M/S Deco grill pattern DG-102 (7.5mm dia and aperture 80x66mm) with suitable aluminium anodised frame F section complete all as specified and directed. |
| 26 | Supply and fixing for in repair 20mm dia stainless steel curtain rod thickness not less than 1.5mm are made of SS-304 with a perfect glossy mirror finish as approved complete all as specified and directed. |
| 27 | Supply and fixing for in repair stainless steel fancy types domes cum brackets suitable for 20 mm dia curtain rod as approved fixed over 1st class hard wood rounded wooden blocks of 65mm dia and 20mm thick fixed to stone wall/Brick wall using screws including necessary drilling & finished with polishing and fixed to both ends with the curtain rod etc complete all as specified and directed. |
| 28 | Taking down gutter and rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 30 | Material & Labour for Non-skid coloured ceramic tiles 7 to 8 mm thick matt finish (square/ rectangular) area of each tile exceeding 0.60 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including screed bed 15 mm thick in CM (1:6) complete all as specified and directed. |
| 31 | Material & Labour for Glazed coloured Ceramic tiles of size 300mmX600mm thickness 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match as in skirting/dado over 10 mm thick rendering in Cement Mortor 1:4 finished complete all as specified and directed. |
| 32 | Taking down / chipping off carefully Loose concrete / plaster by low impact hammer without damaging the structure of any description including cleaning and disposal of debris out side the premises complete all as specified and directed. |
| 33 | Material & Labour for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc complete and applying two coats of alkaline rust converting primer on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and directed. Rust converting primer shall be procured from one of manufacturer given below.(Make :- Krishna Conchem/Dr Fixit/STP Ltd.) |
| 34 | Material & Labour for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minimum solid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction complete all as specified and directed. Anti-rust protective shall be procured from one of manufacturer given below. (Make :- Fosroc/Sika/BASF/Krishna Conchem/UltraTech) |
| 35 | Material & Labour for building up the profile of structural members by using latex B2 modified air cured mortar system (polymer-modified mortars) in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement- 0.5 w/c ratio) upto 20 mm to 40 mm thickness including levelling profiling and removing and cleaning existing vegetation growth in structural and Non- structural items complete all as specified and directed.(Make :- Fosroc/Sika/BASF/Krishna Conchem/UltraTech) |
| 36 | Taking down cement plaster from brick or stone including raking out joints, hacking for key, scrubbing down with water, etc. walls of any description including cleaning and disposal of debris out side the premises complete all as specified and directed. |
| 37 | Material & Labour for 8mm thick in ready mix plaster over masonry or concrete surfaces of wall and ceiling finished fair and even complete all as specified and directed. |
| 38 | Material & Labour for 15mm thick in ready mix plaster in two coat as 10 mm backing coat and 5 mm thick setting coat addition and including WPC of UltraTech WP+ 200 or other equivalent @ 200ml per bag of mortar over masonry or concrete surfaces finished fair and even complete all as specified and directed. |
| 39 | Material & Labour for preparing the new plastered surfaces of wall and applying a coat of primer & two coat of oil bound distemper over 2mm thick wall care putty in two layer complete all as specified and directed. |
| 40 | Material & Labour for preparing the new plastered surfaces of ceiling and applying a coat of primer & two coat of oil bound distemper over 2mm thick wall care putty in two layer complete all as specified and directed. |
| 41 | Material & Labour for complete removal of existing treatment from wall surface and applying a coat of primer & two coat of oil bound distemper over 2mm thick wall care putty in two layer complete all as specified and directed. |
| 42 | Material & Labour for complete removal of existing treatment from ceiling and applying a coat of primer & two coat of oil bound distemper over 2mm thick wall care putty in two layer complete all as specified and directed. |
| 43 | Material & Labour old painted surfaces of wall and applying one coat of oil bound distempering including preparation of surfaces complete all as specified and directed. |
| 44 | Material & Labour old painted surfaces of ceiling and applying one coat of oil bound distempering on walls including preparation of surfaces complete all as specified and directed. |
| 45 | Material & Labour for preparation of new plastered surface and applying one coat of primer (604 raincoat of Pidilite or equivalent) & two coats of Acrylic Elastomeric Exterior Coating (601 raincoat of Pidilite or equivalent) on wall, Chajja, terrace & Parapet wall as per manufactures Instructions, complete all as specified and directed. |
| 46 | Material & Labour for preparation of old plastered surface and applying one coat of primer (604 raincoat of Pidilite or equivalent) & two coats of Acrylic Elastomeric Exterior Coating (601 raincoat of Pidilite or equivalent) on wall, Chajja, terrace & Parapet wall as per manufactures Instructions, complete all as specified and directed. |
| 47 | 1. Taking down and clear the sunken / lowered portion of RCC slab surface for full depth of sunken floor by wire brush chisel out any mortar sticking the surface.2. Apply FOSROC Nitoproof 600PF (minimum 0.8mm dft) over a priming coat of Nitoproof WB Primer or equivalent product of Asian Paints / M/s MC Bauchemie / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP as per manufacturer’s instructions to bottom and full vertical sides of sunken floors complete all as specified.3. Fill it with water and check for dampness and seepage. In case the slightest indication of seepage / leakage is noticed, then apply additional coat of water proofing material complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixing for 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n exc. 0.5 sqm in each pane complete all as specified and directed. |
| 49 | Material & Labour for Preparation of new or previously untreated surfaces of steel or steel-based materials of any description not otherwise described, over 10cm width or girth and applying one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified and directed. |
| 50 | Material & Labour for Preparation of new or previously untreated surfaces of wood or wood-based materials of any description not otherwise described, over 10cm width or girth and applying one coat of pink primer and two coat of synthetic enamel paint, complete all as specified and directed. |
| 51 | Material & Labour for preparation of old painted surfaces of wood or wood-based materials of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 52 | Material & Labour for preparation of old painted surfaces of steel or steel-based materials of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed . |
| 53 | Material & Labour in repair vitreous China wash down water closet pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) with 'P' or 'S' trap complete all as specified and directed. |
| 54 | Supply & Fixing of Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinges devices complete all as specified and directed. |
| 55 | Supply & Fixing in repair chromium plated telephonic health faucet shower with flexible tube of stainless steel, 1.25 Mtr long & hook, multi flow 15mm dia for iron pipe or for brass ferrule complete all as specified and directed. |
| 56 | Supply & Fixing in repair SS toilet paper holder of approved quality complete all as specified and directed. |
| 57 | Supply & Fixing in repairs 15 mm dia two-way bib taps, cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & Fixing in repairs vitreous China squatting pan 'Orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of lime concrete complete all as specified & directed by Engineer-in-charge. |
| 59 | Supply & Fixing in repair PVC valveless, syphonic action type, flushing cistern, low level, white, 10 ltr capacity with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed. |
| 60 | Supply & Fixing of oval shape WHB size 560 x 400 x 205 of \\"Cera\\" or equivalent, fixed in platform including CP brass waste fittings, complete all as specified and directed. |
| 61 | Supply & Fixing in repair vitreous China ware wash hand basin white, angle back, size 400 x 400 mm with CP waste coupling including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed. |
| 62 | Supply & Fixing in repair swan neck pillar cock 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 63 | Supply & Fixing in repair CP Brass 2-in-1 wall Mixer hot and cold water screwed down for iron pipe and fixed for 15 mm dia complete all as specified and directed. |
| 64 | Supply & Fixing in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 65 | Supply & Fixing for 32/40mm waste pipe of length not less than 600mm complete all as specified and directed. |
| 66 | Supply & Fixing in repairs vitreous China urinal, half stall type with all necessary fittings complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply & Fixing in repair Brass chromium plated bottle traps 32 mm for wash basins and urinal with inlet and outlet screwed for pipe or connections including necessary packing, union and cap fixed complete all as specified and directed. |
| 68 | Supply & Fixing for HDPE PVC pipes of pressure rating 6 kgf/Sq.cm of 40 mm bore fixed complete to walls, ceiling or in floors including bend and sockets, Tee etc. any type of pipe complete all as specified and directed. |
| 69 | Supply & Fixing in repair for 15mm bore Stop valves / angle cock, cast copper alloy chromium plated fancy type, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 70 | Supply & Fixing in repair Brass chromium plated shower rose 125mm with swivel joints including fixing to steel pipe or union of 15mm bore complete all as specified and directed. |
| 71 | Supply & Fixing in repair CP Towel ring fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 72 | Supply & Fixing in repair Stainless steel Soap dish as approved by EIC fixed with chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed. |
| 73 | Supply & Fixing for Corner glass shelf of size 300x300mm with assembly of CP as approved by EIC and fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 74 | Supply & Fixing in repair bib taps 15mm dia chromium plated fancy type long body with capstan head screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 75 | Supply & Fixing for 6mm thick and size 850mm x 550mm bevelled edge mirror of selected quality glass, fixed with Mounting round clips / stud of selected quality complete all as specified and directed. |
| 76 | Supply & Fixing for 6mm thick and size 1800mm x 600mm bevelled edge mirror of selected quality glass, fixed with Mounting round clips / stud of selected quality complete all as specified and directed. |
| 77 | Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 78 | Taking up or down 25 or 32mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 79 | Supply & Fixing for 20mm dia of CPVC pipes SDR 11 including all CPVC SDR 11 fitting such as elbow/brass elbow, Tee, Socket, reducer/adopter plain/Brass fittings, clamps etc and necessary cutting grooves or chases and making good after laying as on wall / ceiling or in floors complete all as specified and directed. |
| 80 | Supply & Fixing for 25mm dia of CPVC pipes SDR 11 including all CPVC SDR 11 fitting such as elbow/brass elbow, Tee, Socket, reducer/adopter plain/Brass fittings, clamps etc and necessary cutting grooves or chases and making good after laying as on wall / ceiling or in floors complete all as specified and directed. |
| 81 | Supply & Fixing in repair 25 mm bore gun metal globe or gate valve complete all as specified and directed. |
| 82 | Material & Labour for 15-17mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs pillar window cills, cooking plot forms and including 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary bull nosing / moulding and polishing to edges of granite slab complete all as specified and directed. |
| 83 | Supply & Fixing for 100mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed. |
| 84 | Supply & Fixing for 75mm dia PVC (SWR) floor trap, plain with and including CP grating jointing with solvent cement complete all as specified and directed . |
| 85 | Supply and fixing for PVC (SWR) 110mm bore pipes in any length with rubber ring joints fixed to wall with clamps suitable for 110mm pipe as approved by EIC complete all as specified and directed. |
| 86 | Supply and fixing for PVC (SWR) 110mm bore pipes in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 87 | Supply & Fixing for PVC (SWR) bends (any radius) for rain water pipes 110 mm bore diminishing pieces or tapers on walls complete all as specified and directed. |
| 88 | Supply & Fixing for PVC (SWR) PVC (SWR) branch piece, single (single T or Y) equal or unequal for 110 mm bore pipe diminishing pieces or tapers on walls complete all as specified and directed. |
| 89 | Supply and fixing for PVC (SWR) 75mm bore pipes in any length with rubber ring joints fixed to wall with clamps suitable for 75mm pipe as approved by EIC complete all as specified and directed. |
| 90 | Supply and fixing for PVC (SWR) 75mm bore pipes in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 91 | Supply & Fixing for PVC (SWR) bends (any radius) for rain water pipes 75mm bore diminishing pieces or tapers on walls complete all as specified and directed. |
| 92 | Supply & Fixing for PVC (SWR) PVC (SWR) branch piece, single (single Y or T) equal or unequal for 75mm bore pipe diminishing pieces or tapers on walls complete all as specified and directed. |
| 93 | Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking into credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed |
| 94 | Material & Labour for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One light / Bell point controlled by one, one way switch, complete all as specified and directed. |
| 95 | Material & Labour for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One Ceiling / Exhaust Fan point controlled by one, one way switch, complete all as specified and directed. |
| 96 | Material & Labour for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for one 05 Amps socket outlet point on same board , complete all as specified and directed. |
| 97 | Material & Labour for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for one Switch socket outlet point 5 Amps on independent board , complete all as specified and directed. |
| 98 | Material & Labour for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 4.00 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 2.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for one three pin socket out let, 15 Amps and including 4.00 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board , complete all as specified and directed. |
| 99 | Supply & Fixing for Switch Modular 6A single pole, one way, 1 module complete all as specified and directed. |
| 100 | Supply & Fixing for Switch Modular 16A single pole, one way, 1 module complete all as specified and directed. |
| 101 | Supply & Fixing for Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 102 | Supply & Fixing for socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and directed. |
| 103 | Supply & Fixing for Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified, complete all as specified and directed |
| 104 | Supply & Fixing for ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. |
| 105 | M&L for replacement of old unserviceacble light fitting with LED batten light fitting 25 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
| 106 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 107 | M&L for replacement of old unserviceacble light fitting with LED batten light fitting9 Watts 2 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
| 108 | M&L for replacement of old unserviceacble light fitting with LED security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed by engineer-in-charge.complete in all respect complete all as specified and directed. |
| 109 | M&L for replacement of old unserviceacble light fitting with downlight circular/square 10 W, efficacy not less than 100 lm/w, rated life 25000 burning hours including LED light driver holder connecting up with three core flexible copper conductor cable IP 65 out door type metal body of suitable size complete all as specified and directed.. |
| 110 | Supply and fix MCB DB, TPN, 4 ways, double door, 415 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed. |
| 111 | Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve complete all as specified and directed. |
| 112 | Supply and fixing TPN 63 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete all as specified and directed. |
| 113 | Supply & Fixing for Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and directed. |
| 114 | Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces complete all as specified and directed. |
| 115 | Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces complete all as specified and directed. |