|
| 1 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as reqd (Gr.- B). |
| 2 | Supplying and fixing metal box of size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 180mm x 100mm x 60mm deep |
| 3 | Supplying and fixing metal box of size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep |
| 4 | Supplying & fixing of 3 pin 5/6 amps piano type socket outlet on the existing switch box / cover including connection etc. as reqd. |
| 5 | Supplying & fixing of 5/6 amps piano type switch on the existing switch box / cover including connection etc. as reqd. |
| 6 | Supplying & fixing of 6 pin 15/16 amps piano type socket outlet on the existing switch box / cover including connection etc. as reqd. |
| 7 | Supplying & fixing of 15/16 amps piano type switch on the existing switch box / cover including connection etc. as reqd. |
| 8 | Wiring for circuit / sub-main wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as reqd. 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 9 | Wiring for circuit / sub-main wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as reqd. 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 10 | Wiring for circuit / sub-main wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as reqd. 2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire |
| 11 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 12 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, 25A residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Supplying and fixing of 8-way, Double Door SPN, 240 V, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 14 | Providing of sheet steel DP MCB enclosure. |
| 15 | Supplying and fixing of 4-way (4 + 12), TPN, 415V, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required: Single pole and Neutral |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required: Triple pole and neutral |
| 18 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 19 | Earthing with G.I. earth plate 600mm. x 600 mm. x 6 mm. thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr. long with charcoal / coke and salt as reqd. |
| 20 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing as required. |
| 21 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 22 | Supplying, installing on wall, testing and commissioning of 200 A rising mains made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TEC 439). |
| 23 | Installation of exhaust fan in the existing opening, including making good The Damage connection and commissioning etc. as required (up to 450mm sweep). |
| 24 | Providing of wall mounted LED batten Tube Light 22 W with polycarbonate housing & integrated electronic driver. |
| 25 | Providing of Surface mounted Downlight with Aluminium (99% Purity) Sink, available in Round shape. PC diffuser in white powder coated finish with built in electronic low THD (<10%) LED driver, 24W LED. Fixture size: Ø 210 mm, Height 65 mm. |
| 26 | Providing of Exhaust fans, Heavy Duty, 900 rpm, 300 mm dia. |
| 27 | Providing of 4 x 25 sq. mm. 1.1KV grade, XLPE insulated armoured Aluminium Cable. |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 29 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N |
| 30 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100A TP&N |
| 31 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC Please Enable Macros to View BoQ information |