| 1 | Recessed wiring to light point/ fan point/Exhaust fan point/Call bell point with 1.5sqmm FRLS PVC Insulated single core multistarand copperConductor of ISI marked with 20mm dia non metalic PVC conduit with 6A 250V MODULAR type switch ISI marked and ceiling rose marked mounted on Modular GI Box having front modular base plate of suitable size, with 1.5sqmm FR PVC Single core multistrand copper conductor as earth wire includingall accessories and connection as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) (PVC Conduit Make: AKG, Sudhakar, Precision) (switch /socket/modular GI Board (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) light point Group-A |
| 2 | -do- light point Group-B |
| 3 | -do- light point Group-C |
| 4 | -do- Fan point Group-B |
| 5 | -do- Fan point Group-C |
| 6 | Recessed wiring to 6 AMP Modular socket out let with 2x1.5sq mm for FRLS PVC insulated single core multistrand copper conductor of ISI marked in reccess 20mm dia non metalic PVC conduit Modular GI Box and earthing point with 1x1.5sqmm FR PVC insulated single core multistarnd copper conductor for loop earthing etc,as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) switch /socket/modular GI Board Separate Point (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 7 | On Existing board- |
| 8 | Supplying,fixing of 2X 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 9 | Supplying,fixing of 3X 6A Plug on the separate board with complete fitting by 03 no of 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 03 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 10 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 3pin, 16Amp socket outlet and 16Amp Modular switches connection as required complete in all respect as per direction of Engineer in charge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 11 | Supplying,fixing of 1x6A and 1x16A Plug on the separate board with complete fitting by 01 No of 6 A & 1 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 12 | Supplying,fixing of 2X 16A Plug on the separate board with complete fitting by 02 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))(For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 13 | Recessed Extra lead Sub-main wiring for light and fan point in 2x1.5mm2 FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty conduit 1.6 sqmm thick along with 1x1.5 sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge(Make of wire Finolex / Havells /Polycab) 2x1.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 14 | Recessed wiring to Sub-main in 2x2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x2.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 15 | Recessed wiring to Sub-main in 2x4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x4 sq mm+1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 16 | Recessed wiring to Sub-main in 2x6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x2.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x6 sq mm+1x2.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 17 | Recessed wiring to Sub-main in 4x4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 32mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 2x1.5 sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 4x4 sq mm+2x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 18 | Recessed wiring to Sub-main in 4x10 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 32mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 2x4 sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 4x10 sq mm+2x4 sqmm 1100 Volts confirming to IS 694/1990 |
| 19 | Supply of 16 sq. mm 4 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 20 | Supply of 25mmsq. mm 3.5 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 21 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm on surface as required. |
| 22 | Supply and laying of 2 inch HDPE PVC PIPE ISI Marked complete in all respect as per direction of Engineer in charge (Make:- AKG/ Sudhakar) |
| 23 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm direct in ground in the existing RCC/ HDPE/ STONEWARE/ METAL pipe as required. |
| 24 | S/F of 8 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 25 | S/F of 12 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 26 | S/F of 4 way TPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)) |
| 27 | Supply and fixing of SP 6-32 A, 10 KA rating 240 V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 28 | Supply and fixing of DP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 29 | Supply and fixing of DP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 30 | Supply and fixing of FP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 31 | S/F of 09 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha- S. PH Turbo/Crompton - Trans Air/Khaitan,/ Havells) |
| 32 | S/F of 400 MM Wall Mounted fan all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha/Crompton /Khaitan,/ Havells) |
| 33 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 34 | S/F of step type 2 Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 35 | Supply and fixing of 20watt,CW/WW 5700K,1800 Lumen led Aluminium Housing batten on wall ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) |
| 36 | S/F of A.C. point consisting of 32 amp industrial male female socket &top with 20-32 amp single phase starter with all connection complete in all respect as per direction of engineer incharge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta)) |
| 37 | Supply and fixing of 18 watt Recess Light ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Panasonic/ Great white/ Orient/ wipro/ Havells/Phillips)(2Years Warranty) |
| 38 | S/F of Street light-ENDURA 60 W CITYLINER NEO new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) |
| 39 | Fixing of Street light with G.I bracket and pipe |
| 40 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating ( O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 41 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16) |
| 42 | S/F of copper cooling pipe with insulation packing and flexible copper cable |
| 43 | S/F of Nylon Netted Drain Pipe with C clamp |
| 44 | S/F. Of Powder coated Wall Stand with Anchor Fastener (For 1.5 Ton/ 2 Ton ) |
| 45 | S/F 4 kva voltage stabiliser 130-280V (make : V guard) |
| 46 | S/F 5 kva voltage stabiliser 130-300V (make : V guard) |
| 47 | S/F of Earthing with medium class 40mm 3Mtr. Long ISI marked GI Earth pipe including accessories such as funnel GI nut, Bolt, washer , hinged cover plate with looking arrangement, 40mm to 20GI rediusor 5nos 20mm dia holes on GI pipe required charpol salt, Excavation of earth brick work in cement mortar complete in all respect as per specification of SR 2011 and as per Direction of Engineer-in -Chage |
| 48 | Supply and fixing copper plate earthing 600 mm X 600 mm X 3.15 mm thick ISI marked including accessories and providing masonary with charcoal and salt with all connection complete in all respect as per direction of engineer incharge |
| 49 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for loop earthing along with existing surface / recessed conduit with all connection complete in all respect as per direction of engineer incharge |
| 50 | Supplying and laying 6 SWG G.I wire on surface or in recess for connection etc as required. |
| 51 | Supply and Fixing of 150-185 Sq mm Jointing Kit for 1.1 KV XLPE/ PVC Cables ISI Marked complete in all respect as per direction of Engineer in charge (Make:-3M) |
| 52 | Supply and fixing of Surface mounting With Industrial sockets & Straight plugs ( 380/415 VA, 32 A 3P+N+E) IP 54 making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens/ Hager (VYB8 32C)) |
| 53 | S/F of 63 - 100 A copper busbar panel of size 28*16*8 inch of 63 AMP 4 Pole MCCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator. |
| 54 | S/F of 63 - 100 A copper busbar panel of size 28*16*8 inch of 63 AMP 4 Pole MCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator. |
| 55 | S/F of 63 - 100 A copper busbar panel of size 32*36*10 inch of 63 AMP16 KA MCCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator, with 7 nos 63 Amp 2 Pole MCB, 2 Nos 32 Amp 4Pole MCB etc, |
| 56 | S/F of 63 - 100 A copper busbar panel of size 36*36*10 inch of 63 AMP MCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator, with 2 nos 63 Amp 2 Pole MCB, 2 nos 32 Amp 2 Pole MCB, 2 Nos 32 Amp 4Pole MCB, 63 Amp Changeover etc, |
| 57 | S/F of 200 A cubical panel board made of 16 SWG C.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 72\\"x40\\"x12\\" with copper double busbar of 200A, 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing etc, complete with supply & fixing of following switch gears. RYB Indicator, 1. 200A 25ka 4p Mccb -1no, 2. 100A 25ka 4p Mccb -1no, 3. 200 A C/o-1No, 4.63A 16 KA MCCB-2 Nos, 5. 100A 16 KA MCCB-1 No, 6. 63 Amp DP MCB-2 Nos, 7. 63 Amp FP MCB-1 Nos, 8. SPD separete busbar for both dg and main ,earthing connector, Cable alley. |
| 58 | Supply and fixing of 4 pole (3P+N) ( T1+T2 - Iimp 8 kA/pole T2 - 60 kA) 40 KA SPD in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 59 | Supply and fixing of 4 pole MCCB 200A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 60 | Supply and fixing of 4 pole MCCB 16-100A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 61 | Supply and fixing of 4 pole MCCB 100A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 62 | Supply and fixing of Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 63 | Supply and fixing of 4 pole 63 AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Havells/ C&S /L&K ) |
| 64 | Supply and fixing of 4 pole 200 AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Havells/ C&S /L&K ) |
| 65 | Supply and fixing of DP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 66 | Supply and fixing of DP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) |
| 67 | Supply and fixing of FP 63A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 68 | Supply and fixing of FP 32A, 10 KA rating 415V \\"C\\" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager ) |
| 69 | FIRE DETECTION AND ALARM SYSTEM-:Supply, installation, testing and commissioning of Main Fire Alarm Control Panel (FACP), the panel shall be fire detection and alarm type with capacity of 4 Zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display. Make-System Sensor by Honeywell/GST/Ravel |
| 70 | Supply, installation, testing and commissioning of smoke criteria detector with standard base and other accessories as required. Make-System Sensor by Honeywell/GST/Ravel |
| 71 | Supplying, installing, testing and commissioning of Conventional Manual call point with built in Monitor Module with all accessories complete. Make-System Sensor by Honeywell/GST/Ravel |
| 72 | Supplying, installing, testing and commissioning of Conventional Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The devise shall be UL/EN/FM approved. .Make-System Sensor by Honeywell/GST/Ravel Please Enable Macros to View BoQ information |
| 73 | Supplying, installing, testing and commissioning of Conventional Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The devise shall be UL/EN/FM approved. .Make-System Sensor by Honeywell/GST/Ravel Please Enable Macros to View BoQ information |