| 1 | Earth work in excavation in foundation trenches or drains (not exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50M from edge of cutting . |
| 2 | Providing and laying Stone solling /boulders Hand packed including compacting, watering including all carriages of material complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level (1:4:8) (1Cement: 4 fine sand: 8 grade stone aggregate 40mm nominal size). |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to all levels(.1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Crushed. (All Works up to Plinth level) raft |
| 5 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering. All work up to plinth level1:3:6 (1Cement: 3 fine sand: 6 grade stone aggregate 20mm nominal size) |
| 6 | Centering and shuttering including strutting propping etc. removal of form work in Raft,foundation and plinth (All works upto Plinth level) |
| 7 | Brick work with FPS bricks of class designation 75 in super structure up to all floors. Including carraige of Bricks In cement mortar 1cement: 6 fine sand mortar. |
| 8 | Providing and fixing of wood work in frames of door/ window /arch windows /ventilator wrought frames (chowkats) imported klin Dried Wood(K.D) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to all levels.1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Crushed in suspanded floors, in lintel bands, roof bands etc (Above plinth level) |
| 10 | Supplying, cutting, bending to shape, fabricating, fixing and tying in position TMT Reinforcement Steel at all levels and location as shown in the structural drawing. The rate shall include cost of supply & tying reinforcement with GI binding wire. |
| 11 | Centering and shuttering including strutting propping etc. removal of form work in in lintel bands, roof bands etc (Above plinth level) |
| 12 | Structural steel work welded in built up sections and frame work including cutting, hoisting fixing in position all complete in angles / flats / tubes including MS sheet for chejja,soffits and eveas boarding complete job etc. |
| 13 | Providing and Fixing High Rib Colour coated C.G.I sheet roofing including cost of j-hooks, washers nails 50mm thick. Including cost of overlapped sheets complete job. |
| 14 | Providing and Fixing of ridges hips / valleys ornamental of colour G.I sheets including cost screws/washers all complete job. |
| 15 | 12 mm thickcement Plaster in 1:6 mixture including all carriages and costs. |
| 16 | Appl 2mm thick wall putty on wall surfaces including all carriages and costs. Interior only |
| 17 | Finishing walls with waterproof cement paint of approved brand and manufacture of required shade to give an even shade on new works all complete job. |
| 18 | Finishing wall with Excel emulsion for interiors and exteriors using primer as permanufacturers' specifications Two or more coats applied @ 1.25 litre1 Osqm over and including one Coat ofspecial primer applied @ 0. 751itre/10sqm |
| 19 | Providing and fixing of 35mm thick panelled glazed shutters for window including cost of MS butt hinges and screws all complete job. Imported K.D |
| 20 | Applying Priming coat with ready mixed colour primer of approved brand and manufacture on wood work. |
| 21 | Painting with synthetic enamel paint to give an even shade two or more coates of approved brand and manufacture on wood. |
| 22 | Providing and fixing of hardware items of ISI Marked of standard quality and make.Handles 125mm |
| 23 | Handles 100mm |
| 24 | T bolts 100mm |
| 25 | Concealed Locks 200mm |
| 26 | T Bolts 150mm |
| 27 | Cement Concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg) finished with a floating coat of neat cement incld. cement slurry but excld the cost of nosing of steps etc complete 50mm thick with 20mm n/s stone agg crushed |
| 28 | Ornamental Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as requiredIn gratings, frames, guard bar, ladders, railings, brackets, gates & similar works. |
| 29 | Providing Float glass panes 3.5 mm thick in doors windows and clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured) |
| 30 | Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi -strant copper wire 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work |
| 31 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work.including cost of service line as directed by engineer incharge. |
| 32 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work. Please Enable Macros to View BoQ information |