| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in: |
| 2 | All kinds of soil : 70% |
| 3 | Hard Rock (Blasting Prohibited) : 30% |
| 4 | Extra for every additional lift of 1.5 M or part therefore in all kinds of soil. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level. |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.All works above plinth level upto floor V level. |
| 9 | Providing M-30 grade concrete instead of M-25 grade BMC/RMC. For water tank and spetic tank |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. |
| 12 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.(Thermo-Mechanically Treated bars of grade Fe-500D or more.) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form work for :- |
| 14 | Foundations, footings, bases of columns etc. for mass concrete. |
| 15 | Columns, pillars, piers, abutments, posts and struts. |
| 16 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 17 | Suspended floors, roofs, landings, balconies and access platforms. |
| 18 | Edges of slabs and breaks in floors and walls upto 20cm wide. |
| 19 | Weather shades, chajjas, corbels etc. including edges. |
| 20 | Wall (any thickness) including attached pilasters, buttresses, plinth and string courses fillets etc |
| 21 | Stairs (excluding landings) except spiral stair cases. |
| 22 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 mtr. of part thereof (Plan area to be measured). Suspended floors, roofs landing, beams and balconies (Plan area to be measured). |
| 23 | Providing and laying DPC 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and curing complete. |
| 24 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 fine sand).(Below Plinth) |
| 25 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand). |
| 26 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 27 | Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 28 | Extra for half brick work in super structure above plinth level upto floor V-level. |
| 29 | Extra for providing and placing in position 2 Nos 6mm dia M.S Bars at every third course of half brick masonary . |
| 30 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 31 | 12mm cement plaster of mix 1:6 (1 cement : 6 fine sand). |
| 32 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand). |
| 33 | Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) including curing upto Plinth Level and above plinth level upto floor V level. |
| 34 | Making of grove 12mm x 10mm between brick and RCC. |
| 35 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 36 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete. |
| 37 | Add or deduct for plaster drip coarse / groove in plastered surface of moulding to RCC projections. |
| 38 | Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed. |
| 39 | Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 40 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc. consisting of following: (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining was upto 300mm height including rounding of junction of walls and slaps.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20mm thick joint less cement mortar of mix 1: 4 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm / sq 3mm deep. (e) The whole terrace so finished shall be flooded with water far a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurras as 65mm |
| 41 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 42 | Providing and laying water proofing treatment to vertical and horizontal surface of depressed portions of W.C., kitchen and the consisting of (i) Ist course of applying cement slurry @ 4.4 kg /sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions including rounding of junctions of vertical and horizontal surface. (iii) III course of applying blown or / residual bitumen applied hot at 1.7 kg per sqm of area. (iv) Ivth course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm. |
| 43 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size below flooring, retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing. |
| 44 | Providing and laying vitrified floor tiles in Size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. (Double Charged) |
| 45 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 46 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per direction of Engineer-in-charge |
| 47 | In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 48 | In dado/skirting on 12mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 49 | Providing and fixing 1st quality ceramic glazed floor heavy duty tiles conforming to IS : 15622 300x300 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(Ramp area Tile ) |
| 50 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6mm for diagonal braces |
| 51 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. |
| 52 | Providing and laying 18mm thick Granite of any colour and shape (area of slab over 0.5 Sqm) gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 53 | Extra for providing edge moulding to 18/16 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. |
| 54 | Extra for providing opening of required size and shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble / stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 55 | Providing and laying Ceramic glazed floor tiles ( Mat finish ) (Non-Skid) 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown. |
| 56 | Providing and fixing Ist quality ceramic glazed wall tiles 300X600mm conforming to IS : 13753 of minimum thickness 5mm of approved make like or equivalent make in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer in charge over 12mm thick bed of cement mortar 1:3 (1cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 57 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) : Sal wood |
| 58 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately)Second class deodar wood.35mm thick |
| 59 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes.5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 60 | Providing and fixing of block door shutters in pine wood filling and finished with 1mm thick laminated on both sides. Door held with 4 No.S.S but hinges with necessary S.S screws as per directions of Engineer-in-charge with deodar wood beading of 4mm x 37mm section all around door. |
| 61 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.With stainless steel grade 304 wire gauge with wire of dia 0.50 mm With 2nd class teak wood beading 62x19 mm. |
| 62 | Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges with Stainless Steel screws etc. Complete 100x58x1.90 mm. |
| 63 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 64 | Providing and fixing aluminium tower bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. |
| 65 | 100x10mm. |
| 66 | 150x10mm. |
| 67 | 200x10mm. |
| 68 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 69 | 125mm |
| 70 | 100mm. |
| 71 | Providing and fixing aluminium sliding door bolts ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 250x16 mm. |
| 72 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete |
| 73 | Providing and fixing aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper. |
| 74 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 75 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter. |
| 76 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :- |
| 77 | Coupler 110mm. |
| 78 | Single tee with door 110 x 110 x 110mm. |
| 79 | Bend 87.5* 110mm. |
| 80 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 81 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 82 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube |
| 83 | Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (Wood work). |
| 84 | Providing and fixing wooden moulded beading to door and window frames with S.S screws, plugs and on unexposed surface etc. complete:2nd class teak wood 50 x 20 mm |
| 85 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) |
| 86 | For fixed portion.Powder coated aluminum (minimum thickness of powder coated 50 microns). |
| 87 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 88 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.Pre-laminated particle board with decorative lamination on both sides. |
| 89 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm) |
| 90 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheetouter box with slide plate etc. complete as per the direction of Engineerin-plate etc. complete as per the direction of Engineer-in-charge.With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 91 | Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5mm width |
| 92 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 93 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge.Powder coated minimum thickness 50 micron aluminum tabular handle bar |
| 94 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 95 | 125 mm |
| 96 | 100 mm |
| 97 | 75 mm |
| 98 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 99 | 300x16 mm |
| 100 | 250x16 mm |
| 101 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self centering arrangement that freely rotates / moves in all directions. The Self –centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer-in-Charge. (Material shall confirm to ASTM 6063.)Floor joint of 100 mm gap |
| 102 | Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi-cellular to facilitate movement. (Material shall confirm to ASTM 6063.)Wall joint of 100 mm gap |
| 103 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates/ moves in all directions. The self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint system shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint system to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063.Roof joint of 100 mm gap. |
| 104 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 105 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 106 | Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (Steel work). |
| 107 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately).12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fiber conforming to IS: 2095 part-I, of size 595x595 mm, having perforation of9.7x9.7 mm at 19.4 mm c/c with center borders of 48mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 108 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 109 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete |
| 110 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 111 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 112 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 113 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 114 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.) (In rows 15 cm apart in either direction) . |
| 115 | Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment). |
| 116 | Mixing earth and sludge or manure in proportion specified or directed by officer in charge.Spreading of sludge, dump manure or/and good earth in required thickness as per directions of officer in-charge (cost of sludge, dump manure or/and good earth to be paid separately). |
| 117 | Mixing earth and sludge or manure in proportion specified or directed by officer in charge. |
| 118 | Supplying and stacking at site Graded crushed stone aggregate of size 90 mm to 45 mm . |
| 119 | Supplying and stacking at site 13.2 mm nominal size (Type A) |
| 120 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 121 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge |
| 122 | Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity |
| 123 | Providing and applying tack coat using hot straight run bitumen of grade – VG-30, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On W.B.M. @ 0.75 Kg/sqm |
| 124 | 2.5 cm premix carpet surfacing with 2.25cum and 1.12 cum of stone chippings of 13.2 mm and 11.2mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively including a tack coat with hot straight run bitumen including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). With paving Asphalt grade VG-10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. |
| 125 | Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-30 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete . |
| 126 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipesn with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete 900 mm dia. R.C.C. pipe |
| 127 | Carriage of Building Rubbish/Material at an average lead of 2KM by Mechanical Transport including loading, unloading and stacking. |
| 128 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete |
| 129 | Sand for an average lead of 15 Kms. |
| 130 | Stone aggregate below 40mm size for an average lead of 10 Kms. |
| 131 | Stone aggregate 40mm and above 40mm size for an average lead of 10 Kms. |
| 132 | Bricks for an average lead of 10 Kms |
| 133 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall: |
| 134 | 15 mm dia. nominal bore |
| 135 | 20 mm dia. nominal bore |
| 136 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Internal work-Exposed on wall.Medium |
| 137 | 25 mm dia. nominal bore |
| 138 | 32 mm dia. nominal bore |
| 139 | 40 mm dia. nominal bore |
| 140 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. ( External work / Terrace Work ) Medium Class |
| 141 | 50 mm dia. nominal bore |
| 142 | Painting G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. |
| 143 | 15 mm dia. nominal bore |
| 144 | 20 mm dia. nominal bore |
| 145 | 25 mm dia. nominal bore (Medium) |
| 146 | 32 mm dia. nominal bore (Medium) |
| 147 | 40 mm dia. nominal bore (Medium) |
| 148 | 50 mm dia. nominal bore (Medium) |
| 149 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 150 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture |
| 151 | Providing and fixing PVC pipe confirming to IS:12818 for Drainage & Sewerage system including all necessary fittings.This Includes jointing of pipes and fittings with PVC Solvent and testing of joints complete. Under Floors and Internal Works Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) around the pipe.as per the direction of Engineer Incharge. |
| 152 | 100mm |
| 153 | Providing and fixing PVC pipe confirming to IS:12818 for Drainage & Sewerage system including all necessary fittings.This Includes jointing of pipes and fittings with PVC Solvent and testing of joints complete as per the direction of Engineer Incharge. External work including trenching, refilling and Cement Concrete around the Pipe 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) etc. |
| 154 | 150mm |
| 155 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line. |
| 156 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 500x700 mm and 45 cm deep for single pipe line with one or two inlets |
| 157 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 600x850 mm and 45 cm deep for single pipe line with three or more inlets. |
| 158 | Extra for depth beyond 45 cm of brick masonry chamber with common burnt clay(non modular) bricks of class designation 7.5 |
| 159 | For 455x610 mm size |
| 160 | For 500x700 mm size |
| 161 | For 600x850 mm size |
| 162 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 163 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.100 x 100 mm size P type.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 164 | Providing and fixing PTMT grating of approved quality and colour. |
| 165 | 100 mm nominal dia. |
| 166 | 125 mm nominal dia with 25mm waste hole |
| 167 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 168 | Supply, assembly, erection, testing and commissioning of pumping system comprising the following : Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (wilo,ebara and mather platt etc.) Pump Capacity 180 lpm, at 30 m head (1 working + 1 standby) (Domestic water relift pump). |
| 169 | Providing and fixing white vitreous china pedestal type water closet (European type) + Flush Tank with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 170 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 171 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 172 | Providing and fixing complete set of sanitary fixtures for handicapped toilets, comprising of European WC - P , Cistern, Seat Cover, Twin Flush Fittings, Wash Basin 450x300, Half pedestal, 1 faucet with spatula lever, 1 hinged rail and 2 grab bars, including cutting and making good the walls and floors wherever required complete as per directions of Engineer in charge. |
| 173 | Providing and fixing white vitreous china flat back lipped front urinal basin of 430 x260x350 mm respectively. |
| 174 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with ½” BSP thread and shapes, weighing not less than 60 gms. |
| 175 | Providing and fixing PTMT urinal cock of approved quality and colour : 15 mm nominal bore, 80 mm long, 42mm high and 30 mm wide with BSP female threads weighing not less than 48 gms |
| 176 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth.16mm Granite Stone of approved shade. |
| 177 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings.Flat back wash basin of size 630x450 mm. |
| 178 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 179 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 180 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. |
| 181 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 182 | Providing and fixing toilet paper holder.C.P. brass. |
| 183 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required : Size 600x450x200 mm. |
| 184 | Providing and fixing, testing and commissioning of C.P brass Sink mixer with regular swinging spout (wall mounted model) with connecting legs and wall flanges complete as required and making good as per direction of Engineer-in-charge |
| 185 | Providing & fixing of white vitreous china under counter oval wash basin/circular basin with CP brass waste assembly, CP cast brass bottle trap with extension piece , 450mm long CP copper connections pipes, wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge. |
| 186 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 187 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 32 mm dia. |
| 188 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 189 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. Complete |
| 190 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 191 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 192 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. |
| 193 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 194 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with open able circular lid.150 mm nominal size square 100 mm diameter of the inner hinged round grating. |
| 195 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 196 | Providing and fixing heavy class SS grating plane floor trap and setting in floor with cement mortar to matach the floor finish as per direction of Engineer-in-charge (size 100mm dia) ISI marked. |
| 197 | Providing & fixing storage type water cooler with plain & cold water facility of the following capacity, I.S.I marked, stainless steel front panel, C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to F.D complete as required (Blue Star or equivalent).Cooling capacity 20 Ltrs./hr (Model No. Bluestar PC240). Storage capacity 40 Ltrs. |
| 198 | Providing & fixing commercial 10 LPH water purifier of required capacity. Including all components as per manufacture specifications, including connection from water supply line, and final connection to water cooler Electric wiring & plug top etc. with all accessories. |
| 199 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 200 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, .25 mm nominal bore |
| 201 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). |
| 202 | 32 mm nominal bore |
| 203 | 40 mm nominal bore |
| 204 | 50 mm nominal bore |
| 205 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 206 | Group C |
| 207 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 208 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. |
| 209 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 210 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 211 | 4 X 4 sq. mm + 2 X 6 sq. mm earth wire |
| 212 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 213 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 214 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 215 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 216 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 217 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 218 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 219 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 220 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 221 | 4 way (4 + 12), Double door |
| 222 | 6 way (4 + 18), Double door |
| 223 | 8way (4 +24), Double door |
| 224 | 12way (4 +36), Double door |
| 225 | Supplying and Fixing of Following Ratings of D.P MCB 240 Volts \\"C\\" Series in the Existing MCB D.B complete with connections,Testing and Commissioning Etc. as Required. |
| 226 | 32 A D.P MCB 10 Ka \\"C\\" Curve |
| 227 | Supplying and Fixing of Following Ratings of RCCB Conforms to IS 12640 (Part 1) / IEC 61008-1 in the Existing MCB D.B complete with connections,Testing and Commissioning Etc. as Required. |
| 228 | 63 A D.P 30 mA |
| 229 | 40A D.P 30 mA |
| 230 | 25 A D.P 30 mA |
| 231 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 232 | 25 A F.P MCB 10 Ka \\"C\\" Curve |
| 233 | 40 A F.P MCB 10 Ka \\"C\\" Curve |
| 234 | 63 A F.P MCB 10 Ka \\"C\\" Curve |
| 235 | Supplying and fixing 5 amps. To 32 amps. Rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 236 | Single Pole |
| 237 | Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required. |
| 238 | Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Earth pit chamber (300mm x 300mm) with CI cover for the above. |
| 239 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 240 | Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 241 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 242 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt, Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 243 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required . |
| 244 | 300 mm |
| 245 | Supply installation testing and commissioning of IP20 led downlighter 12 W +/- 15 W LED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 246 | Supply installation testing and commissioning of 90W, Pole mounted IP66 Street Light with System efficacy of 100 lm/W, PC lense with Toughened Glass Cover with IK rating IK08. LED Street Light shall be made up of Die cast Aluminium Housing for better heat decapitation. L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.The Price is inclusive of Bracket made out of Pipe of Suitable Size for Fixing the Light Fitting along the Parapet Wall. |
| 247 | Supply & Fixing of 36W , 2x2 LED reccesse type Luminaire suitable for operating Voltage range of 150V-270V with inbuilt surge protection of 2KV and Color temprature 5700K ANSI BIN . Minimum system lumens 4320 and system efficacy >120 Lm/watt (Supported by in house NABL approved report of LM79 provided by OEM and duly signed by company manager not below rank of RM) . Luminaire should be suitable for armstrong /grid ceiling mounting with help of 4 Nos clips for suspension. Body made up of CRCA powder coated with Diffused Optics. Luminaire size should not be less than 595x595x60mm and power factor >=0.95, CRI>=80, THD<10%, Max system wattage should be 36 Watt, IP-20 ingress protection. NABL certification and BIS (both luminaire and driver) requried to be provided at the time of sample approval. |
| 248 | Supply installation testing and commissioning of IP:20 Aluminium Batten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 249 | Supply installation testing and commissioning of IP:20 Aluminium Batten 40 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 250 | Supplying,Installation,Testing and Commissioning of Cubical Type Main L.T outdoor Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars,Interlocking , etc. as required to match the SLD as per the Following Description.(IP:42).Refer SLD for DetailsINCOMERAdj. TMR Based MCCB 400 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (02 Nos)Contactor 400 A F.P 415 Volts,AC-3 Duty(02 Nos)Automatic Transfer Controller Equivalent to LK AUX-C 2000 ControllerDigital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar( 500 Amps ) and MCB Strip of suitable size as Required.OUTGOINGSAdj. TMR Based MCCB 320 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (02 Nos)Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (04 Nos)Load Bearing Members to be made out of 2.0 mm CRCA Sheet.Partitions to be made out of 1.6 mm CRCA SheetGland Plates to be 3.0 mm Thick. |
| 251 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD (Appx Size:- x x mt).INCOMERTMR Based MCCB 320 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (01 Nos)Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar( 400 Amps ) and MCB Strip of suitable size . As Required to be Part of the BOM to be Furnished by the Panel Supplier.Note:- The Panel Builder shall not start the Fabrication of Panel unless the G.A Drawings are approved by the Engineer Incharge or Consultant.(Refer SLD)Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar( 400 Amps ) and MCB Strip of suitable size . As Required to be Part of the BOM to be Furnished by the Panel Supplier.Note:- The Panel Builder shall not start the Fabrication of Panel unless the G.A Drawings are approved by the Engineer Incharge or Consultant.(Refer SLD)OUTGOINGSMCB 63 A F.P \\"C\\" Curve 10 Ka(12 Nos)MCB 40 A F.P \\"C\\" Curve 10 Ka(08 Nos)MCB 25 A F.P \\"C\\" Curve 10 Ka(02 Nos)Load Bearing Members to be made out of 2.0 mm CRCA Sheet.Partitions to be made out of 1.6 mm CRCA SheetGland Plates to be 3.0 mm Thick. |
| 252 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD (Appx Size:- x x mt).INCOMERTMR Based MCCB 200 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH (01 Nos)TMR Based MCCB 160 Amps FP Icu=Ics=100% Breaking Capacity 16 KA with Extendable ROH (01 Nos)Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(500 Amps ) and 400 AMP respectively MCB Strip of suitable size as Required,PLC,HMI,Contactor Etc. As Required to be Part of the BOM to be Furnished by the Panel Supplier.Note:- The Panel Builder shall not start the Fabrication of Panel unless the G.A Drawings are approved by the Engineer Incharge or Consultant.(Refer SLD)OUTGOINGSMCB 63 A F.P \\"C\\" Curve 10 Ka(06 Nos)MCB 40 A F.P \\"C\\" Curve 10 Ka(05 Nos)MCB 25 A F.P \\"C\\" Curve 10 Ka(02 Nos)Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet. Gland Plates to be 3.0 mm Thick. |
| 253 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 254 | 160 mm dia (OD-200 mm & ID-135 mm nominal) |
| 255 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 256 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 257 | 3.5 C X 300 Sq.mm A2XFY |
| 258 | 4.0 C X 16 Sq.mm Aluminium Armoured |
| 259 | 3.5 C X 120 Sq.mm A2XFY |
| 260 | 3.5 C X 70 Sq.mm A2XFY |
| 261 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) |
| 262 | 3½ X 300 sq. mm (70mm) |
| 263 | 4.0 X 16 sq. mm (28mm) |
| 264 | Supply, transportation,Unloading , installation,testing & Commissioning of 10KVA/ 10 KW (3Ø IN: 3Ø OUT).The UPS contains power electronics, controller, input/output switches, static switch, display and any other ancillary equipment required for operation.The UPS should be as Per 1. IEC 62040-1 - Uninterruptible Power Systems (UPS) Part 1: General and safety requirements, IEC 62040-2 - Static uninterruptible power systems (UPS) Part 2: Electromagnetic compatibility (EMC) requirements, EN 62040-3 - Static uninterruptible power systems (UPS) - Methods of specifying the performance and test requirements, IEC 62040-4 - Uninterruptible power systems (UPS) - Environmental aspects - Requirements and reporting, EN 60529-2 - Protection levels of enclosures (IP rating).The UPS shall be designed to operate in a minimum of 4 units in parallel with ring communication cable architecture. The whole UPS system shall be designed for Power Factor 1 ambient temperature, The UPS battery shall be designed for 15 minutes back up considering 0.9 Power factor, Aging factor 1.25,Design margin 1.1 a lead acid batteries/ VRLA SMF batteries .Input voltage and range AC Input Nominal Voltage:• 380 - 400 - 415 V, 3ph + N + PE,• Dual / Single input., AC Input Voltage Range: (-15/+20 % 400 V) 340 to 480 V at full load .The UPS must be able to provide Power Factor = 1 (kW=kVA) up to 40 °C according to EN62040-3 without derating and this performance rating must be tested and verified by an independent, accredited body.The UPS shall be able work in hot standby configuration. |
| 265 | Supply installation testing and commissioning of 40 W Post Lantern Lamp Pressure die-cast aluminium housing with specially designed optics, provide uniform light distribution to redefine outdoors and enhance architectural design with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab..Mayfair Lighting. |
| 266 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 267 | Supply,Installation of 3 Mtr Decorative Pole made of Galvanised Mild Steel Pipe in two Pieces with H1(139.7mm @ 1 Mtr),H2(76.1mm @2 mtr) with Base Plate not less than 300 x 300 x12 mm Duly Painted with Polyurethane Paint all over. |
| 268 | SITC of IP: 66/IP:67 PVC Junction Box having the Facility to house 4 way Bakellite strip for connection to the spike light.(Make:- Hensel) |
| 269 | Supplying and Laying of Sheathed 3 C x 2.5 Sq.mm Copper Conductor Multistrand Wire IS:694. |
| 270 | SITC of Cubical Out Door Type Feeder Pillar Fabricated with 2.0 mm CRCA Sheet with 100 A Aluminium Bus Bar Cable alley Provision for Cable Entry Locking Arrangement and Internal Wiring,Connection Painting with 1 coat of red Oxide and 2 Coat of Synthetic Enameled Paint I/C Supplying and Fixing of Following Accessories as required Incomer MCCB 63 A F.P 36 Ka with Adj. T.M.R with Extendable ROH Icu=Ics=100%(01 Nos) Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(100 Amps) and MCB Strip of suitable size as Required.Outgoings F.P MCB 32 A ,10 KA,\\"C\\" Curve (04 Nos.) Size of wiring for CTS=2.5 sqmm Size of wiring for voltage sensing Metering:- 4.0 Sq. mmTypes of wires:- PVC insulated 1100V grade ,Multostrand copper Conductor Flexible FR-LSH Hinged Door Earthing :- Device mounted hinged Doors connected to cubicles body by means of 2.5 sqmm green copper flexible wire .The Complete panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. Gland Plates to be 3.0 mm Thick. |
| 271 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 272 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 273 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 274 | Supplying,Installation,Testing and Commissioning of Ceiling Mounted Automated Modular Fire Suppression System (ABC MAP90 Powder Based ) - 10KG suitable for Class A, B, C and Electrically started fires. |
| 275 | SITC of Dry Type Co2 Type Fire Extinguisher 4.5 Kg |
| 276 | SITC of ABC Type Fire Extinguisher IS 15683 4.0 Kg Having Deep drawn and CO2 MIG welded can construction ,Epoxy polyester powder external coating,Epoxy powder internal coating,Body Thickness 1.6 mm(Cease fire) |
| 277 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 278 | Telephone socket outlet |
| 279 | TV antenna socket outlet |
| 280 | Computer Socket RJ45 Modular type |
| 281 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 282 | 1 or 2 Module (75mmX75mm) |
| 283 | Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required. |
| 284 | 20 mm PVC Conduit |
| 285 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit as required. |
| 286 | 2 Pair |
| 287 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 288 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 289 | 1 run of cable |
| 290 | Supply & Erection of lockable 12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC. |
| 291 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome Camera, 1/2.7\\" CMOS or better, 5MP (2880 x 1620) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 30m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/2-1/100000S,Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:50°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T Compliant, CE, FCC, EN, RoHS & NDAA Section 889 compliant. |
| 292 | Supplying and Laying of 20 Mtr HDMI Optical Fiber Cable AOC 2.0, 4K with Bandwidth 18Gbps |
| 293 | Supplying and Fixing of S.D Card 256 G.B in the Existing Camera |
| 294 | Supply & Erection of CAT 6, 16 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable. |
| 295 | Supply & Erection of CAT 6, 24 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable. |
| 296 | Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC. |
| 297 | Supply & Erection of Cat-6, 3 Mtr Patch Cords complete as per specification and as desired by EIC. |
| 298 | Supplying,Installation,Testing and Commissioning of 55 Inches Ultra HD 4K LED Display Monitor with 3840 x 2160 pixels (Min.) |
| 299 | Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Vedio Recorder) Embadded Linux based for recording upto 16CH @ D1 with 02 nos. SATA HDDs minimum 20TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Control Pannel with LEDs Indication, 2 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidance Clip Export to USB, 16 Channel Syncronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Softawre, iPhone; iPad; Android based Mobile clients, 01HDMI & 01VGA Output, 02 On Board HDDS each up to 10TB, Alarm Input (1 nos.), Alarm Output (01 nos.), NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA, CE, FCC, EN, NDAA & RoHS compliant.including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. |
| 300 | SITC of 10TB 7200 rpm SATA 6 Gb/s 3.5\\" Internal Enterprise Hard Drive |
| 301 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 302 | Supply, Installation, Testing and Commissioning of 10/100/1000 Mbps Unmanaged Switches with Provision of 16 10/100/1000 Mbps ports as per specification and as desired by the Engineer Incharge. |
| 303 | Supply, Installation, Testing and Commissioning of 10/100/1000 Mbps Unmanaged Switches with Provision of 24 10/100/1000 Mbps ports as per specification and as desired by the Engineer Incharge. |
| 304 | Supply,Installation,Testing and Commissioning of Media Converter. |
| 305 | Supply & Erection of Termination Box complete as per specification and as desired by EIC. |
| 306 | Supplying,Installation,Testing of 12 Core Optical Fibre Cable Single Mode. |
| 307 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated inapproved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 zone panel for fire alarm system250 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) pushbutton for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visualindication etc., complete as required- 1 set Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and ACvoltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 308 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 309 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. |
| 310 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 311 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 312 | 2 x 1.5 sq. mm |
| 313 | Supply,installation with foundation as per approved Drawing 9 Mtr. Long Pole,ST-410 SP33) |
| 314 | Supply,installation of Structural Steel as per Standard Approved Drawing |
| 315 | Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps). |
| 316 | Supply,Installation of 11 KV L.A 10 ka (Station Class). |
| 317 | Supply,Installation of 11 KV HG Fuse Unit . |
| 318 | Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC. |
| 319 | Supply and Installation of 100 Sq.mm AAAC Triple AAAC. |
| 320 | Supply,Installation of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 321 | Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection. |
| 322 | Supply and Installation of Anti Climbing Device |
| 323 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 324 | Supply, Installation Testing and commissioning of 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 325 | 250 Kva |
| 326 | Supply, Installation testing and commissioning of indoor type termination kit for 3 C x 50 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).(Raychem make) |
| 327 | Supply, Installation testing and commissioning of outdoor type termination kit for 3 C x 50 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).(Raychem make) |
| 328 | Supplying and Laying of XLPE Insulated and PVC Sheathed Power Cable of 11KV/ 1.1 KV Grade of the following size direct in Ground including excavation,sand Cushioning,Protective Covering and Refilling the Trench as Required. |
| 329 | 3 C x50 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable). |
| 330 | Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 331 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 332 | Supplying,Installation,Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 333 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 334 | Provision for Tap Off Point for Electricl Substation |
| 335 | Design, Supply, installation, testing and commissioning of a 200KVA Servo Controlled Automatic Voltage Stabilizer, 3 phase, oil cooled (transformer oil to be the cooling medium conforming to IS-335 with latest amendments) conforming to IS-8447-1989, IS-9815 I & II of 1994 amended up to date. The voltage stabilizer should be suitable to operate on unbalanced input voltage of 250-460 volts and delivering output voltage of 415 + 1% volts, 3 phase, 50 + 3% cycles/second frequency of A.C power supply. The stabilizer shall be copper wound Out door Type. I) The voltage stabilizer shall be suitable for the following configurations:- a) Input Voltage: 160-460 Volts b) Output Voltage: 415 + 1% c) Frequency: 50 Hz + 3% A.C supply d) Output current: 180.00 amps per phase e) Duty: continuous 24x7 f)Temp. Rise in Oil:-50 degree C g) Temp. Rise in Winding:-55 degree C h)Overload Capacity:100% for 1 minute i)Regulator: Rolling Contact Type j) Type: Unbalanced Type –Suitable for unbalanced input voltage and unbalanced load, Outdoor g) Design and Testing Standards:IS:9815/IS 2026 k) The no-load current shall not be more than 5% of the rated output current. II) Instrument Accessories: The voltage stabilizer shall be provided with as under:-a) Mains ON indicating lamps for each phase.b) Indicating lamps in each phase with lights up/ audio alarm when the input voltage exceeds beyond limit or overload or phase failure/phase reversal. c) Voltmeter at input & output with voltage selector switch to read input/output voltage in each phase. d) Switch to change over from automatic to manual operation .e) Auto/manual switch raise/lower push button in each phase. f) Ampere meter with selector switch. g) Control circuit separate in each phase. h) Protection against high & low voltage, single phasing, cut off alarm, its cancellation, short circuiting, overload protection and earth fault relay. i) By Pass Arrangements:- By pass switch shall be provided to by pass the stabilizer in case of any fault. j) Heavy terminal blocks and solid state controlled circuit for input, output and earth connections, which should be clearly marked. k) Protections: Suitable capacity MCCB for tripping the stabilizer in case of under voltage, over voltage, short circuit, overload, single phasing conditions . l) Efficiency at full load more than 95%. The stabilizer should be conforming to IS 9815/1981. m) Purity of copper shall be minimum 99.97% (Certificate from manufacturer shall be attached along with the Invoice). n) The stabilizer should have aesthetic outlook with screen printed panel.Make of Instrument Accessories: G.E./ L&T / Siemens / Schneider / Havells/other reputed make conforming to relevant ISI code). III) Characteristic features:- The three phase Servo Controlled Automatic Voltage Stabilizer shall have the following characteristic features:- a) Continuous duty performance at ambient temperature 2 °C to 55° C. b) Stable and effective system power factor and frequency fluctuation as well as overload up to 15% and under load up to 50% of the connected load. c) Low internal impedance. d) Negligible wave form distortion during starting, under operation and stopping conditions. e) Accommodate the effect of higher starting current and should be able to recover from the shock. f) No overshooting or hunting. g) Negligible phase shift ensuring no change in system power factor. h) Should ensure fast correction of voltage according to voltage variation specified. i) The stabilizer shall have a suitable breather with leak-proof desludging and drain cock for transformer oil, lifting hook for mechanical handling, guage for oil level etc. j) The three phase unbalanced automatic servo controlled voltage stabilizer should take care of the unbalanced supply with A.C step synchronous motor.IV) Markings:- The stabilizer shall be marked with manufacture’s name and trade mark on the plate fitted on the stabilizer and indicate KVA rating, range of input and output voltage, rated output current, frequency, number of phases, type of load viz unbalanced input and balanced load, quantity of transformer oil and also reference to I.S. standard. In addition, the information relevant to Servo-Motor viz Rated KW, Rated Voltage, Type of Supply and No. of Phases etc. shall also be given on the rating plate. V) Testing & Inspection:- The equipment shall be inspected and tested before dispatch to the consignee by the third party. The firm shall have adequate testing facilities available at their work site. The scope of inspection shall include testing of stabilizer as per type of test prescribed in IS-9815 of 1994 and 8447 of 1989 as relevant to Servo Controlled Voltage Stabilizers. It shall also include testing of voltage stabilizer for all protections. The testing of the stabilizer shall comprise of the following tests:- a) Insulation resistance test. b) High Voltage test. c) Under voltage test. d) Provision of earthling. e) Leakage current test. f) No load current test. g) Measurement of no load losses. h) Load loss test and efficiency. i) Induced voltage test. j) Test for continuous operation. k) Temperature rise test at lowest voltage of 260 volts. l) Test for rate of correction. m) Locked rotor test for servo motor. n) Full load test. VI) Layout of Components/Drawings:- Layout of Components and control wiring shall conform to established engineering practice from the consideration of case for maintenance.VII) The job involves shifting of stabilizer to site by way of lifting, carriage and unloading manually or with mechanical crane and installation of the stabilizer, providing and laying of insulation mats etc. Complete job in all respects. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail