| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings, complete all as specified and as directed. |
| 2 | S&F Pre painted galvalume aluminum zinc coating GI based corrugulated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 3 | S&F Pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description, complete all as specified and as directed. |
| 5 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 6 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillet, complete all as specified and as directed. |
| 7 | S&F in repairs for Non asbestos fibre cement building boards of 6mm thick fixed or laid/ inserted totimber/GI/Aluminium framework with screws, complete all as specified and as directed. |
| 8 | Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work), complete all as specified and as directed. |
| 9 | S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8 all as per manufacturer's instruction, complete all as specified and as directed.(Make : Everest or equvalent as approved by GE) |
| 10 | Dismantling of boarding any description fixed in any position with nails/screws, complete all as specified and as directed. |
| 11 | S&F facia boarding of 2nd class soft wood planed one side with but joints 20mm thick and champhered one side and the boarding is matched, complete all as specified and as directed. |
| 12 | M&L for second class hard wood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed, complete all as specified and as directed. |
| 13 | All as per Item no 12 above herein before specified but fixing only. |
| 14 | M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 15 | M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 16 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing near cement slurry @3 Kg per sqm, complete all as specified and as directed. |
| 17 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 18 | M&L 350x 250x 7 mm or 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM (1:4) finished even and rough, complete all as specified and as directed. |
| 19 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 20 | M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick CM (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 21 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 22 | M&L for 75 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. |
| 23 | M&L for PCC (1:2:4) type B2 (using 20mm graded crushed stone aggregates) as in surface channels, drains including all necessary form work, complete all as specified and as directed. |
| 24 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 25 | M&L 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in CM (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 26 | M&L for 10 mm thick rendering in CM (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and fair (without using extra cement) complete complete all as specified and directed. |
| 27 | Supply only integral water proofing compond, complete all as specified and as directed. |
| 28 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed. |
| 29 | M&L preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent), complete all as specified and as directed. |
| 30 | M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 31 | M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed. |
| 32 | M&L for preparation of old plastered surfaces of wall and applying two coats of oil bound distemper, complete all as specified and as directed. |
| 33 | Dismantling of timber fillets, rails, posts raftersn fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and as directed. |
| 34 | M&L for 2nd class hard wood Plain fillets of sectional area exc. 13 and not exc. 25 sqcm.square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and as directed. |
| 35 | Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) , complete all as specified and as directed. |
| 36 | Taking down Chowkhats or frames exc 1.5 sqm but n exc 4 sqm with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 37 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints, complete all as specified and as directed. |
| 38 | S&F 35 mm thick second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers, complete all as specified and as directed.(Note:- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 39 | S&F 35 mm thick second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and as directed.(Note:- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 40 | S&F 30 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and as directed.(Note:- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 41 | S&F 30 mm thick second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and as directed.(Note:- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 42 | S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed. |
| 43 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quions, arches, pillars etc but excluding ashler facing dressed stone work and precast concrete, complete all as specified and as directed. |
| 44 | M&L for old size bricks work with subclass 'B' bricks straight or curved on plan exc 6m mean radius as in CM (1:4), complete all as specified and as directed. |
| 45 | M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified and as directed. |
| 46 | S&F in repairs 25 mm dia curtain rod (curtain rails), aluminium alloy, powder caoted with and including decorative knobs etc, complete all as specified and as directed. |
| 47 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and as directed. |
| 48 | S&F 100 mm size butt hinges, medium weight , cold rolled, mild steel, complete all as specified and as directed. |
| 49 | S&F of 125 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 50 | S&F of 200 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 51 | S&F 125 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 52 | S&F 150 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 53 | S & F in reapirs of 1mm thick stainless steel sink with drainage board kitchen or laboratory type with waste pipe, plugs, wsahers, and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting nion to pipe over all size of sink 915mm x 460mm and bowl size 410mm x 330mm x 160mm, complete all as specified and as directed. |
| 54 | S&F Brass CP Sink mixre, Swan neck swivel spout, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nut, screwed for 15mm bore iron and fixed, complete all as specified and as directed.Make: Jaquar or equivalent as approved by GE |
| 55 | M&L Reinforced cement concrete (1:2:4) (nominal mix) Type B-1 (20 mm grading crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 56 | Use and Waste of Formwork to chullah hoods, cha jjas, troughs and similar items including edges, complete all as specified and as directed. |
| 57 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed. |
| 58 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 59 | S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and as directed. |
| 60 | S&F in repairs vitreous china wash basin white of any pattern, flat back of size 450mmx300mm (excluding taps), waste, chain and plug including waste pipe ,suitable size of brackets and making good the damaged walls as per existing wall finish, complete all as specified and as directed. |
| 61 | S&F 40 mm waste coupling of CP (half or full threased) (Minimum weight 60 gms), complete all as specified and as directed. |
| 62 | S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror, complete all as specified and as directed. |
| 63 | S&F in repairs angle, stop valve 15 mm bore, chromium plated,but fancy type, chromium plated with long shank and cup with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 64 | S&F in repairs 15 mm bore, chromium plated,bib tap fancy type with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 65 | S & F Pillar tap Fancy Type cast copper alloy 15mm bore with capstan head, chromium plated, screwed down high pressure, with or with out lettered \\"Hot\\" or \\"Cold\\" with long screw shank and fly nuts, screwed for iron pipes, complete all as specified and as directed. |
| 66 | S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and as directed. |
| 67 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/100/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and as directed. |
| 68 | S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls/trenches, complete all as specified and as directed. |
| 69 | S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 70 | S&F of 110 mm bore PVC (SWR) bend any radius, complete all as specified and as directed. |
| 71 | S&F of 75 mm bore PVC (SWR) bend any radius, complete all as specified and as directed. |
| 72 | S&F of 110 mm bore PVC (SWR) juntion single T equal or unequal with access door joininting with solvent cement complete all as specified and directedbend any radius, complete all as specified and as directed. |
| 73 | S&F of 75 mm bore PVC (SWR) juntion single T equal or unequal with access door joininting with solvent cement complete all as specified and directedbend any radius, complete all as specified and as directed. |
| 74 | S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-290, Gde E-165, complete all as specified and as directed. |
| 75 | Gratings, fixed in repairs 100mm dia, complete all as specified and as directed. |
| 76 | S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 77 | S&F in repairs aluminium anodised tubular towel rail of 20mm dia D' type 60cm long between flanges, complete all as specified and as directed. |
| 78 | Taking down unserviceable copper/aluminium point wiring of any description including all fittings and fixtures (switch , socket, switch socket combination, lamp holder, ceiling rose,light fittings and regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed. |
| 79 | Dismantling and taking down unserviceable main switches, DBs etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed. |
| 80 | M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including PVC Casing and Caping (medium grade) with all fittings and accessories ISI marked fixing in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps, complete all as specified and as directed. |
| 81 | Description all as per item No 80.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board. |
| 82 | Description all as per item No 80.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board. |
| 83 | Description all as per item No 80.00 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 15/16 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 84 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 85 | Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 86 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 87 | Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 88 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. |
| 89 | Supply and fixing Modular angle holder insulated body with back plate for batten fitting, complete all as specified and as directed. |
| 90 | Supply and fixing 10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat shrink Invertor lamp, complete all as specified and as directed. |
| 91 | Supply and fixing LED batten surface /Roof/ wall mounted pride plus inverter battenwith Lithium Ion battery, 3 step dimming, upto 10 Hrs battery backup, charging time- 8 to 10 Hrs, 20w, 6500K V1, complete all as specified and as directed.Make Havells cat part No: LHEXASP71W020 or equivalent of philips or crompton. |
| 92 | Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min), complete all as specified and as directed. |
| 93 | Supply and fixing wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base, complete all as specified and as directed. |
| 94 | Supply and fixing in repairs LED 2X2 PANEL 36 W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, complete all as specified and as directed. |
| 95 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed. |
| 96 | S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting, complete all as specified and as directed. |
| 97 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall, complete all as specified and as directed. |
| 98 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 99 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 100 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 m deep bellow ground level) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC (1:3:6) type C-1, 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I. Incl taking down old u/s earthing, complete all as specified and as directed. |
| 101 | Material and labour in repairs for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing, complete all as specified and as directed. |
| 102 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and as directed. |
| 103 | Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer, complete all as specified and as directed. |
| 104 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed. |
| 105 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed. |
| 106 | M&L in repairs Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick, complete all as specified and as directed. |
| 107 | S & F in repairs Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 108 | S & F in repairs Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. Please Enable Macros to View BoQ information |