| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description, complete all as specified and as directed. |
| 5 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 6 | S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 7 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet, complete all as specified and as directed. |
| 8 | Providing & fixing with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles for false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS-8225 : 1987, Non-combustible as per BS 476 (Part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main - T runners of size 15 x 32 mm of length 3000mm, cross - T of size 15 x 32mm of length 1200mm and secondary intermediate cross - T of size 15 32mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm, Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm centre to centre and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per direction of the Engineer-in-charge, complete all as specified and as directed. |
| 9 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, complete all as specified and as directed. |
| 10 | M & L for 25mm thick Cement concrete (1:2:4) type B-0, (12.5mm graded crushed stone aggregate) placed in any position, complete all as specified and as directed. |
| 11 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including 20 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 12 | M&L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick rendering on fair faces in CM (1:4), complete all as specified and as directed. |
| 13 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames), complete all as specified and as directed. |
| 14 | Resecuring or easing & adjusting, without taking down shutters of any description n.exc 1 sqm each etc, complete all as specified and as directed. |
| 15 | S&F Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed, complete all as specified and as directed. |
| 16 | M&L PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) for filling in bed block of hold fast etc, complete all as specified and as directed. |
| 17 | S&F 2nd class HW 35mm thick factory made panelled shutters with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Pt-I) kiln seasoned and chemically pressure treated, complete all as specified and as directed. |
| 18 | S&F 300mm long Aluminium alloy anodised Sliding bolt with hasp, staple(bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and as directed. |
| 19 | S&F 200mm long Aluminium anodised barrel tower bolts of extruded section etc, complete all as specified and as directed. |
| 20 | S&F 150mm long Aluminium handle of cast type anodised, complete all as specified and as directed. |
| 21 | Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete, complete all as specified and as directed. |
| 22 | M&L brick work with sub class `B' bricks straight or curved on plan exc 6.0m mean radius built in CM (1:6), complete all as specified and as directed. |
| 23 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 24 | Rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces etc, complete all as specified and as directed. |
| 25 | Rendering 15mm thick in CM (1:4) on other than fair faces of brick work or concrete surfaces etc, complete all as specified and as directed. |
| 26 | Cutting chases, pinning in, making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth on stone, concrete block or slab walls etc, complete all as specified and as directed. |
| 27 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and as directed. |
| 28 | Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase raillings and similar work including attached pillasters, buttresses, ect; vertical or to batter finished the surface fair, complete all as specified and as directed. |
| 29 | M&L for PCC (1:3:6) Type C-2 as in surface channels and drains, complete all as specified and as directed. |
| 30 | Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete with using extra cement incl. forms moulds, mitred / stoped ends, complete all as specified and as directed. |
| 31 | M&L for rendering 10mm thick in CM (1:4) including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 32 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, complete all as specified and as directed. |
| 33 | Providing precast RCC (1:2:4) type B-I (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM (1:4) including necessary formwork, complete all as specified and as directed.Note: Reinforcement shall me measured and paid for separately. |
| 34 | S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 35 | M&L mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups spacers and binders, complete all as specified and as directed. |
| 36 | Returning filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm in soft / loose soil, complete all as specified and as directed. |
| 37 | Removing of excavated soil not exceeding 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed. |
| 38 | M&L for 100mm thick Cement concrete (1:4:8) type D 2, (using 40 mm graded crushed stone aggregate) in sub base of flooring etc, complete all as specified and as directed. |
| 39 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/ path laid slope of 1 in 12 and finshing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. |
| 40 | S&F Chequered cement concrete tiles 30 cm x 30 x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM (1:4), complete all as specified and as directed.Note : (Glazed type tiles colour and deisgn as approved by the GE) |
| 41 | M&L Cement concrete (1:2:4) type B-0, (12.5 mm graded crushed stone aggregate) as in coping, mud stop etc, complete all as specified and as directed. |
| 42 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in positioin to the required line, level and curvature, joined with CM (1:3) (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required, complete all as specified and as directed. |
| 43 | Preparation of new or previously untreated surfaces of brick, stone, concrete, asbestos cement or plaster surfaces of any description, over 10cm in width or girth, not otherwise described and apply two coat of synthetic enamel paint over a coat of priming paints plaster coat etc, complete all as specified and as directed. |
| 44 | M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 45 | M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed. |
| 46 | Preparation of old painted surface of wood and wood based surface any description not otherwise described over 10cm width or girth including knotting and stopping and all preparation work required and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 47 | All as per item no 46 above but n.exc 10cm width or girth etc. |
| 48 | Preparation of old painted surface of steel surface any description not otherwise described over 10cm width or girth including knotting and stopping and all preparation work required and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 49 | M&L for preparation of new surface/undecorated surfaces of walls and applying three coats of white wash on plastered surfaces etc, complete all as specified and as directed. |
| 50 | M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of chalk whiting priming paint, complete all as specified and as directed. |
| 51 | M&L for complete removal of existing treatment of wall surfaces and applying two coats of white wash etc, complete all as specified and as directed. |
| 52 | M&L for complete removal of existing treatment of wall surfaces and applying two coats of Cement Base Paint of approved tint over a coat of chalk whiting priming paint, complete all as specified and as directed. |
| 53 | M&L for PCC (1:4:8) type D2 (40 mm graded crushed stone aggregate) in foundation,filling and mass concrete, complete all as specified and as directed. |
| 54 | M&L for RCC M-20 (using 20 mm graded crushed stone aggregates) in foundation,including,rafts, footing,foundation beams,plinth beams, bases for columns,etc basement slabs under reamed piles and mass concrete, complete all as specified and as directed. |
| 55 | M&L for RCC M-20 (using 20 mm graded crushed stone aggregates) in column,pillars,piers,posts and struts, complete all as specified and as directed. |
| 56 | M&L for formwork to sides of concrete footings bases of columns, complete all as specified and as directed. |
| 57 | M&L for formwork for columns, complete all as specified and as directed. |
| 58 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 59 | S & F PVC false ceiling with light weight PVC hollow section panel made of 1mm thick and over all thickness of panel 7 mm thick and 200mm vide strip of plain coloured / melamine finish , fixed in new false ceiling grid made of Aluminum / G.I / M.S / wooden, complete all as specified and as directed.Note : - New false ceiling grid of aluminium / GI / MS / wooden if provided shall be measured and paid separately. |
| 60 | S&F (Size of Grid 605x605mm) Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and as directed. |
| 61 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and as directed. |
| 62 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like iCM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granie, complete all as specified and as directed. |
| 63 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161*-1979 grade St.240, complete all as specified and as directed. |
| 64 | M&L rendering 15mm thick in CM (1:4) inculding finished even and fair on brick or concrete surface, complete all as specified and as directed. |
| 65 | Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed. |
| 66 | Dismantling and taking down unserviceable main switches, DBs etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed. |
| 67 | M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked concealed in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps, complete all as specified and as directed. |
| 68 | Description all as per item No 67.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board. |
| 69 | Description all as per item No 67.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent boad. |
| 70 | Description all as per item No 67.00 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15/16 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 71 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 72 | Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 73 | Supply and fix Modular Bell push 6A 1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 74 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 75 | Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 76 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. |
| 77 | Supply and fixing Modular angle holder insulated body with back plate for batten fitting, complete all as specified and as directed. |
| 78 | Supply and fixing 10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat shink Invertor lamp, complete all as specified and as directed. |
| 79 | Supply and fixing LED batten surface /Roof/ wall mounted pride plus inverter battenwith Lithium Ion battery, 3 step dimming, upto 10 Hrs battery backup, charging time- 8 to 10 Hrs, 20 Watt, 6500K V1, complete all as specified and as directed.Make:Havells cat part No:LHEXASP71W020 or equivalent of philips or crompton |
| 80 | Supply and fixing wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base, complete all as specified and as directed. |
| 81 | Supply and fixing in repairs LED 2X2 PANEL 36 W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, complete all as specified and as directed. |
| 82 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, including lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed. |
| 83 | S & F LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting, complete all as specified and as directed. |
| 84 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC, concealed in wall, complete all as specified and as directed. |
| 85 | Supply and fixing in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 86 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 87 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1:3:6) type C-1 , 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I, complete all as specified and as directed. |
| 88 | Material and labour in repairs cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing including taking down old u/s cable, complete all as specified and as directed. |
| 89 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, connectioon and testing, complete all as specified and as directed. |
| 90 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed. |
| 91 | M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick, complete all as specified and as directed. |
| 92 | S & F Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. |
| 93 | S & F Steel pipe glavanized light grade of 25 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. |
| 94 | M & L for junction box hot press moulded SMC of size 155 x 155 x 100 with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having TPN Bus bar 100A amps capacity including MCB SP 2 AMPS breaking capacity 10 KA 'C' Curve capacity with necessary base insulator and including necessary flat iron clamps with nuts, bolts & washers, complete all as specified and as directed. |
| 95 | Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified and as directed. |
| 96 | Supply and fix New generation, IP 65/IP 66 LED post-top Lantern designed for indirect , Decorative outdoor lightning in areas like Gardens and Pathways. It features a die-cast aluminium housing in a matte black finish, a high-performance optical grade PC Diffuser, and a spigot mounting on a pipe Including suitable length of GI pipe for mounting on post top lantern with all fitting and accessories etc. Water and dust protection, a 5700K color temp and an integrated 4KV surge arrestor for protection against electrical sutges, complete all as specified and as directed.Make- Crompton Cat Part No : CBP-610-40-57-SL-CA-NBK or equivalent of Philips, Havells. |
| 97 | M&L for sub main wiring along with earth wire of size two run of 1.5 sq mm + one run of 1.5 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm dia metalic steel pipe on surface of wall/roof, complete all as specified and as directed.(Note Three run of 1.5 Sqmm including one run of 25 mm steel pipe shall be measured as one unit length). Complete all as specified or directed. Please Enable Macros to View BoQ information |
| 98 | M&L for sub main wiring along with earth wire of size two run of 1.5 sq mm + one run of 1.5 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm dia metalic steel pipe on surface of wall/roof, complete all as specified and as directed.(Note Three run of 1.5 Sqmm including one run of 25 mm steel pipe shall be measured as one unit length). Complete all as specified or directed. Please Enable Macros to View BoQ information |