| 1 | SUPPLY OF FLANGES -STAINLESS STEEL FOR AG & UG PIPING (LOT-4) FOR MSB, PFCC, GDS, FF FOR NREP PROJECT incuding TPI charges as specified in Material Requisition. |
| 2 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 3 | WN FLG SS DUAL (NACE), 300,0, B16.5, BW END,SCH 10S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 10S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03%, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103 |
| 4 | WN FLG SS DUAL (H2 SER.), 300,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 5 | WN FLG SS DUAL, 300,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 6 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 7 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 8 | WN FLG SS DUAL, 300,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 9 | WN FLG SS DUAL, 600,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 10 | WN FLG SS, 300,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F321, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006 |
| 11 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 12 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 13 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 14 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 15 | BF SS DUAL, 600,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 16 | BF SS DUAL, 600,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 17 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 18 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 19 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 20 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 21 | SW FLG SS DUAL, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 22 | SW FLG SS DUAL (H2 SER.), 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 23 | SW FLG SS DUAL (H2 SER.), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 160, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 24 | SW FLG SS DUAL (H2 SER.), 600,0, B16.5, SW END,SCH XXS,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH XXS, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 25 | SW FLG SS DUAL, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 26 | SUPPLY OF FLANGES -STAINLESS STEEL FOR AG & UG PIPING (LOT-4) FOR MSB, PFCC, GDS, FF FOR NREP PROJECT incuding TPI charges as specified in Material Requisition. |
| 27 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 28 | WN FLG SS DUAL (NACE), 300,0, B16.5, BW END,SCH 10S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 10S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03%, FOR SOUR(NACE) SERVICE REQ. ACC. TO, NACE MR0103 |
| 29 | WN FLG SS DUAL (H2 SER.), 300,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 30 | WN FLG SS DUAL, 300,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 31 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 32 | WN FLG SS DUAL, 150,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 33 | WN FLG SS DUAL, 300,0, B16.5, BW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 34 | WN FLG SS DUAL, 600,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 35 | WN FLG SS, 300,0, B16.5, BW END,SCH 80S,RF, FLANGE A182 Gr.F321, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006 |
| 36 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 37 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 38 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 39 | BF SS DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 40 | BF SS DUAL, 600,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 41 | BF SS DUAL, 600,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 42 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 43 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 44 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 45 | SW FLG SS DUAL, 150,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 80S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 46 | SW FLG SS DUAL, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 47 | SW FLG SS DUAL (H2 SER.), 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 48 | SW FLG SS DUAL (H2 SER.), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH 160, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 49 | SW FLG SS DUAL (H2 SER.), 600,0, B16.5, SW END,SCH XXS,RF, FLANGE A182 Gr.F304/304L, MAT. DELIV. COND. SCH XXS, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% |
| 50 | SW FLG SS DUAL, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F316/316L, MAT. DELIV. COND. SCH 40S, ADD. INFORMATION, DOCUMENTS TO BE FOLLOWED, TK-1ZZZA-PI-SPE-0006, SHALL BE DUAL CERTIFIED AND THE, MAXIMUM CARBON CONTENT SHALL BE 0.03% Please Enable Macros to View BoQ information |