| Sl. No. | Item Description |
| 1 | Rewiring for light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Rewiring for fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 3 | Rewiring for exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Rewiring for call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 5 | Supplying and drawing 3 x 1.5 sq. mm sq. mmsizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | Supplying and drawing 3 x 2.5 sq. mmsizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | Supplying and drawing 3 x 4 sq. mm sq. mmsizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | Supplying and drawing 3 x 6 sq. mm sq. mmsizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | Supplying and fixing 5/6 A switch modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | Supplying and fixing 2Way 5/6 A switch modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing 15/16 A switch modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | Supplying and fixing 3 pin 5/6 A socket outlet modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | Supplying and fixing 6 pin 15/16 A socket outlet modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing Bell push modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 17 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 22 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 23 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 24 | Supplying and fixing PVC batten/ angle holder including connections etc. as required |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS /HFFR PVC insulated copper conductor single core cable etc. as required. |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 2.5 Sq. mm. + 1 x 2.5 Sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 4 Sq. mm + 1 x 4 Sq. mm. earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 6 Sq. mm + 1 x 6 Sq. mm. earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 29 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 10 Sq. mm + 1 x 6 Sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 x 16 Sq. mm + 1 x 6 Sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 31 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 x 10 Sq. mm + 1 x 6 Sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 32 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 x 16 Sq. mm + 1 x 6 Sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. |
| 33 | Rewinding of 1200 mm. sweep ceiling fan New model including cost of winding wire and material labour, less cost of burnt wire. |
| 34 | Rewinding for 300 mm sweep LD exhaust fan including cost of required materials and less cost of old material. |
| 35 | Oiling greasing of 1200 mm sweep ceiling fan including taking and refitting the same. |
| 36 | Supply of fresh air Fan 300 mm. Make-Crompton and equivalent. |
| 37 | Supply of 400 mm sweep AC 230/250 volts, 50 HZ wall mounting revolving fan with brackets etc. complete |
| 38 | Installation, Testing and Commissioning of Upto 450 mm sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 39 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 40 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 M/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. steel/Al body Power Factor not less than 0.9, Service Value |
| 41 | Supplying and installaton 600 mm width X 62.5 mm depth X 2.0 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 42 | LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of 18 watt LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. |
| 43 | Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 44 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of 18-22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protectionof 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life nds, CCT 3000°K / 4000°K / 5700°K /6500°K |
| 45 | (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS /HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 46 | Supply and Fixing of water tight oblong 10 Watt LED bulkhead luminaire having pressure die cast housing with driver set confirming to IP-65 and above protection IK08, high purity transitivity UV stabilized Non yellowish diffuser for unform light distribution, detachable driver set open and short circuit protection suitable for 24 Hr continuous operation complete in all respect. CAT-AAA 1200 System Lumens > 120Lm/W, PF>0.95, CRI > 70,>300V over voltage protection, 4 KV internal surge protection metal housing with 5 year warrantee. |
| 47 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 48 | Supply and fixing of 7 mtr. G.I. octagonal pole of approved make (top dia 70mm, bottom dia 130 mm & base plae 12mm thick) having 3mm, thickness with double arm baracket length of 1 mtr. Lengrg id 1 mtr. Length in 1:2:4 RCC foundation bolt including the cost of foundation , excavation & back filling and required T & P complete in all respect. |
| 49 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilized PC cover and lenses suitable for 75 to 90 Watt and Confirming to IP 66 and IK07 and above Protection complete in all respect |
| 50 | Supply and fixing of factory wired integral LED flood light luminaries with die cast aluminium housing with tougtened glass/UV stablised PC cover and lenses built with mandatory driver set suitable for 170 to 200 watt confirming to IP 66 Ik 07 and above protection complete in all respect including labour . 16800-18000 system lumens , high power LED with lenses>120 LM/watt , PF >0.95 THD <10% at full load CRI >70, potted driver set in metal housing (not circuitory) phase to phase protection at 440 volt and > 300 volt autocut and restrart feature 4 Kv interanl surge protection with 5 year warratny CAT -AAA |
| 51 | Supply and Fixing of 5A To 32A rating Single Pole 240/415V, 10ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 52 | Supply and Fixing of 5A To 32A rating triple Pole and neutral 240/415V, 10ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 53 | Supplying and fixing 5 A to 32 A rating Triple pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 54 | Supplying and fixing 40 A , double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 55 | Supplying and 40 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 56 | Supplying and 63 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 57 | Providing and fixing 125 A,36KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required |
| 58 | Providing and fixing 200 A,36KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required |
| 59 | Supplying and Fixing of 8 Way double door, single pole and neutral, sheet steel, MCB Distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator). |
| 60 | S&F of Surface /flush mounting 4 ways SPN D.B. with additional metal door without MCB complete in all respect. |
| 61 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 62 | Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 63 | Supplying and fixing of 4 way (4 + 12), Double door urface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 64 | Supplying and fixing of 8 way (4 + 24), Double door, Double door urface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 65 | REPAIRING AND ADD ON OF SWITCH GEARS/FABRICATION OF EXISTING essential distribution panel of outdoor/ indoor type fabricated out of 2 mm thick CRCA sheet steel, wall / floor mounting type. The sheet steel shall undergo minimum seven tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect as per attached general specifcations. The MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with trip setting as per load requirement. TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All MCCB's shall be thermomagnetic type. All outgoing MCB's shall be C type with 10 KA breaking capacity. The above board shall be complete with 3 nos. phase indicating lights, flush mounted Ammeter, Voltmeter, CT's, PT's, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires. Essential Panel Incomer 100 Amp 4 Pole - 36 KA MCCB- 2 nos. outgoings 40 Amp DPMCB - 20 nos. in separate compartment Bus coupler 1 no. 120 amp 4 P MCCB 1 set of indicating lamps for ON/OFF of bus bar 63 Amp -4 pole MCCB- 10 Nos. with rotary handles for operation |
| 66 | MV PANELS SITC of non essesntial distribution pannels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate status like ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc |
| 67 | and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfault protection with Current & Voltage metering & LCD display. Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) Normal Panel-1/2/3/4 INCOMING1 Nos.630 Amp MCCB 25KA R,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCB Inbuilt Zone Slelective Interlocking function Multifunction Meter BUSBARS 1 Nos. 630 Amp FP busbars of aluminium alloy as per SLD. 4 Nos. 200 Amp FP MCCB 25KA 2 nos. 32 Amp FP MCCB 25KA On, Off, Trip Status Indication with control MCB OUTGOING along with taking back of old normal sub panels. Short Circuit Breaking capacity should not less than 25 KA. |
| 68 | Pump and water treatmentRepair of Horizontal Monoblock pumping Set 3 phase having C.I. casing & CI impeller complete with all accessories, motor of required capacity Pumps shall have following duty: Repair of Filter Feed Pumps 3 phase Flow rate = 350 lp Head = 30 mtr Quantity = 01 Nos. |
| 69 | Repair of Treated Water Transfer Pumps 3 phase Flow rate = 350 lpm Head = 50 mtr Quantity = 01 Nos. |
| 70 | Repair of Submercible with minimum 12 mm solid handling capacity, pumping Set having C.I. casing & CI impellercomplete with all accessories, motor of required capacity Pumps shall have following duty:Flow Rate : 300 lpm Head =10 mtr Quantity = 01 Nos. |
| 71 | Supply, installation, testing and commissioning of motor control panels suitable for 415 volts, 3 phase, 4 wire,50 Hz totally enclosed, free standing type, moisture dust and vermin proof complete including aluminium bus bars, painting etc. as specified with the following mountings. For Water Supply Pumps One Main incoming moulded case circuit breaker 63 Amps capacity R.Y.B Phase indicating lights with control fuses - 1 Set. One fully taped aluminium bus bar of 200 amp capacity Two Nos. Suitable DP MCB for Filter Feed Pumps Two Nos. suitable MCB for Treated Water Transfer Pumps Two Nos. Suitable MCB for Drainage Pumps Six fully automatic DOL starters one each for Filter Feed Pumps / Filter Water TR. Pumps / Drainage. Pumps Six rotary manual/auto/off switch. One panel type voltmeter with rotary selector switch for reading voltage between the phases. Four panel type Ampere meters of suitable rating one for each motor, except metering pumps. Spare space in panel for two starters units with accessories upto 5 HP capacity. All internal wiring colour coded from incoming main to MCB, starters, meters, indicating light and bus bar complete in all respect. 1 No 6A SP MCB & 1 No 16A SP MCB for light & power of pump room Space for four liquid level controller within the panel Note : MCB's shall be suitable for Motor |
| 72 | Providing and fixing dust and vermin prrof motor control panel fabricated from 14 SWG MS sheet with stove enameled paintand comprising of (for tube well pumps) One feeder of 20 ampere 4 pole ELCB One fully automatic DOL starter with Push buttons and indiacting lights One panel type volt meter 96 m square with rotary selection switch for reading voltage between phase and neutral or incoming feeder Three neon phase indiacting lights on incoming main . One ampere meter 96 m square panel type of approprate range . Etched plastic indetification plates for all switch gears Space for liquid level controller All internal wiring should be colour coded from incoming main to switchgear ,starter , meters ,indicating lights |
| 73 | Solar heating systemRepairing , replacing and servicing/ Add on of existing Solar Hot Water indirect Heating System OF 3200 Litre capacity, using heating liquid medium comprising of flat plate solar collectors, including all interconnecting insulated G.I. piping, primary and secondary recirculation pumps, air release valve all mounted on galvanized MS sections complete with connection. |
| 74 | Repairing , replacing and servicing/ Add on existing Solar Hot Water indirect Heating System OF 1800 Litre capacity, using heating liquid medium comprising of flat plate solar collectors, including all interconnecting insulated G.I. piping, primary and secondary recirculation pumps, , air release valve all mounted ongalvanized MS sections complete with connection. |
| 75 | Repairing and connecting to electric grid/main LT panel of existing roof top solar energy system of 104 KW .The job includes all required supplies of solar system whatever required /repair of SS mounting structure , suitable size cables for inter connection and upto main LT panel etc. complete in all respect as per direction of engineer in charge. |
| 76 | MAIN LT PANELRepair/Add on of existing MAIN LT panel Main L.T. cum APFC PanelRepairing adding on whatever required affecting proper connections, testing and commissioning of existing 2 MM thick CRCA sheet steel fabricated cubical type Main L.T. Panel with PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels, expandable type etc. The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. With following specifications. All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with |
| 77 | all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified for all ACB's and MCCB's breakers is Ics value (service rating). The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT's & PT's, etc. Separate CT's shall be provided for protective and measuring system and for APFCR of capacitor bank with suitable VA. The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec. INCOMERS from 2 nos. 400 kVA Transformers following four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release with LCD / LED display for event history & measurement of current parameters, 35 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 INCOMING 2 no. 800 Amp FP EDO type Air Circuit Breaker. (From 2 Nos. 400 KVA Transformers) BUS COUPLER 1 No. 1000 Amp FP EDO type Air Circuit Breaker. |
| 78 | 1 Set of indicating lamps for ON & OFF of bus coupler. BUS BARS 1200 Amp TPN busbars as per SLD. (All incommer & buscoupler shall be interlocked.) OUTGOING 400 A- 4 Pole MCCB- 6 No. (36 kA) for 4 Nos. Non Essential Panel.( 2 SPARE) 320 A- 4 Pole MCCB- 2 No. (36 kA) for Capacitor Panel.250 Amp 4 Pole MCCB (Icu rating-36 KA)-2 No .( TO DG Panel) Inside building100 A - 4Pole MCCB- 36 kA for Cattle shed125 A - 4 Pole MCCB- 5 No. (36 kA) for 2 Nos. Spare63 A 4 Pole MCB- 10 KA - Main Gate63 Amp 4 Pole MCB 10 KA - 4 Nos. Spare32 Amp DP Pole MCB 10 KA - 6 Nos. Spare INSTRUMENTS 2 Nos. 0 to 500 Volt digital voltmeter with Voltmeter Selector Switch & Protective SP MCB (96mm square) (one for each Incoming Breaker). 2 No. 0 to 1500 Amp digital ammeter (96mm square) with CT's. 2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 2 Sets of 3 Phase O/V and U/V relay with time delay (O/V - 100% to 140% U/V - 80% to 95%). 2 Sets of 3 phase, Single Phasing Preventor (one set for each transformer incoming) 2 Sets of 3 phase, Phase reversal relay (one set for each transformer incoming) 2 Set of CT's one of 2000/ 5Amp ratio for APFC relay. 2 Nos. |
| 79 | Frequency meter (one for each Incoming Breaker). 2 Nos.Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI with RS 485 communication port for communication / report generation. 2 Nos. master trip relay (one for each Incoming Breaker). 2 Nos. Hooter with accept & reset PB. 2 Nos. 12 window announciator set as per the specification and site requirements 1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing. 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. CAPACITOR BANK PANEL (300 KVAR) - 1Set INCOMING Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit including manual/ automatic operation switch. BUS BARS 630 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature. |
| 80 | OUTGOINGS - 4 nos. of 125 AMPS TPN 35 KA MCCB and 150 amps AC3 duty contactor with 50 KVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 4 nos. of 63 AMPS TPN 35 KA MCCB and 80 amps AC3 duty contactor with 25 KVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 8 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches. 1 No. Toggle switch for changing automatic to manual operation of capacitor units. 1 No. Indicating lamp for each 50 / 25 KVAR capacitor unit to indicate that the unit is 'ON'. Power factor meter etc. complete as required Main L.T. Panel cum Capacitor Panel Described as above Panel should be such that it may be run by both transformer independently as well as may run by both transformer simultaneously |
| 81 | DG PanelRepairing , adding on whatever required making proper connection, testing and commissioning of existing Main LT Panel. The panel has following specifications. Each Incomming MCCB shall have microprocessor release and variable current setting from front, overcurrent & short circuit protection and Outgoing MCCB shall have thermal magnetic release front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables. All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified for all ACB's and MCCB's breakers is Ics value (service rating). The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT's & PT's, etc. Separate CT's shall be provided for protective and measuring system. All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0 with dual source Energy Meter |
| 82 | The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec. Incomer ratings 250 Amp 4 Pole MCCB (Icu rating-36KA)- 1 No. incomer from DG sets and 1 No. from Solar panels 250 Amp 4 Pole MCCB (Icu rating-36 KA)-2 No.( From Main LT Panel) BUS BARS 3 sections of 300 AMP 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. Instruments 9 window annunciator with accept / reset / test push button for DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares. for two numbers DG set each Indication for load on each DG's and anuunicator system for |
| 83 | DG load for load less than 40 % and load exceeding 75% of its load. Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop. Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps. D.G. control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out. 2 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (125 KVA) Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. The MCCB shall be electrically interlocked with the bus coupler and Transformer incomers. Protection releases / relays, Metering & Accessories for Bus Coupler (s) Trip circuit supervision relay TNC switch. Auto / manual selector switch 5 Nos. LED type indicating lamp for indicating the status of feeder - ON /OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. The bus coupler shall be electrically interlocked with all incoming MCCB's in such a way that at any one time two supply should not get mixed up. OUTGOINGS - |
| 84 | All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0 125 A - 4 Pole MCCB- 4 No. (36 kA) for 4 Nos. Essential Panel. 125 A- 4 Pole MCCB- 1 No.( 36 KA) for STP 125 A- 4 Pole MCCB-1 No. (36 kA) for UG Tank 125 A- 4 Pole MCCB-1 No. (36 kA) for Fire Fighting 100 A 4 Pole MCCB-4 Nos.(36 KA) for Spare 63 Amp-4 Pole MCB- 6 Nos.(External Light Feeder Pillars) with astronmical switching- Icu-10 KA 32 Amp- DP MCB- 6 Nos. /(External Light feeder pillars) withastronomical switching-Icu-10 KA |
| 85 | Repairing , servicing and rewiring of extranal lighting panel with supply of all required MCBs, MCCBs and wiring , T&P etc. complete in respect INCOMER : 100 AMP FP MCCB BUS BAR : 100 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / OUT GOINGS : amp.a)8 no 63 AMP FP MCB (10 KA) b)2 no 40 AMP DP MCB (10 KA) |
| 86 | Supply and laying of 10 Sq. mm. 4 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 87 | Supply and laying of 10 Sq. mm. 2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 88 | Supply and laying of 16 Sq. mm. 4 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 89 | Supply and laying of 25 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 90 | Supply and laying of 35 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 91 | Supply and laying of 50 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 92 | Supply and laying of 70 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 93 | Supply and laying of 120 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 94 | Supply and laying of 150 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 95 | Supply and laying of 240 Sq. mm. 3- 1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade in existing RCC/Hume/Metal pipe as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. |
| 96 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 97 | 2 X 10 sq. mm (19mm) |
| 98 | 4 X 10 sq. mm (25mm) |
| 99 | 4 X 16 sq. mm (28mm) |
| 100 | 3½ X 25 sq. mm (28mm) |
| 101 | 3½ X 35 sq. mm (25mm) |
| 102 | 3½ X 50 sq. mm (35mm) |
| 103 | 3½ X 70 sq. mm (38mm) |
| 104 | 3½ X 120 sq. mm (45mm) |
| 105 | 3½ X 150 sq. mm (50mm) |
| 106 | 3½ X 300 sq. mm (62mm) |
| 107 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 108 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 109 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 110 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 111 | Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
| 112 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 113 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 114 | Repairing and water proofing existing brick masonry Inspection Chamber (Cable trench) of size 900 x 900 x 1000 mm along with supply of all material, T& P complete in all respect total lenth 120 mtr for 4 nos. trenches |
| 115 | Provision for ensuring power supply 24 hour basis to the building during repair work by making alternate narrangement of power supply either through temporary DG set or temporarily installed panels /cables etc. |
| 116 | 125 KVA D.G. SET Repairing, servicing, Fixing, testing and Commissioning of 125 KVA Silent type Diesel Generating Set along with AMF panel , making existing AMF panel operational including suply all required spairs, loops etc. complete in all respect TOTAL OF DG WORKS CARRIED OVER TO SUMMARY OF ELECTRICAL WORKS |
| 117 | CAMCProviding 5 years comprehensive maintenance of complete electrical installations including 24-hour electrician availability, preventive and breakdown maintenance, fault finding, troubleshooting, repairs, replacement of defective parts due to normal wear and tear, minor consumables, tools, and compliance with safety and statutory requirements, complete as directed by Engineer-in-Charge. @ 45,000.00 per month. |
| 118 | HT WorksReparing/Replacement of existing 11 KV HT VCB four breaker panle board indoor type (1 INCOMMING + 2 OUTGOING) including supply of all spaires/material as required complet in all respect. 11 KV H.T. VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE) Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 11 KV Three Breaker Vacuum Circuit Breaker Panel 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum INCOMING PANEL - 1 NO. 1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, 3 No. Single Phase double core current transformer 300/5 Amp epoxy cast insulated class of insulation E. Core 1-15VA burden class 1.0 for metering. Core 2-15VA burden class 5P10 for protection. P.T's of 11KV/1.732, 110V/1.732, 200VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required. One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements. 1 No. |
| 119 | Anti Pumping device. 1 No. Circuit breaker control switch for electrical (T/N/C). 1 No. limit switch for test & service position. 1 No. Voltmeter (0-12KV) with selector switch. (96mm square) 1 No. Ammeter (0-300Amp) with selector switch. (96mm square). 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. 1 Set of following indicating lamps. Red, Yellow & Blue for phase indication. Amber for Trip indication. Red `ON' Green `OFF' Spring charge indication. Auto trip indication. 1 No. hooter with hooter acceptance and reset push button. 1 No. master trip relay. ( Electromechanical Type ) 1 No.Trip ckt supervision relay (Electromechanical Type ) 600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.1 Set of fuses, ferrules, wiring etc. as required. Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate 1 Set of Power Pack 110 Volt A.C. / 24 Volt D.C. complete as required. (Suitable for breaker tripping circuit) OUTGOING PANEL- 2No. (Each outgoing feeder shall have following) 1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed |
| 120 | ,air insulated metal clad housing, 2 No. Single Phase double core current transformer 75/5 Amp epoxy cast insulated class of insulation E. Core 1-15VA burden class 1.0 for metering. Core 2-15VA burden class 5P10 for protection. One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements. 1 No. Anti Pumping device. 1 No. Circuit breaker control switch for electrical (T/N/C). 1 No. limit switch for test & service position. 1 No. Ammeter (0-75Amp) with selector switch. (96mm square). 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc.1 Set of following indicating lamps. Red, Yellow & Blue for phase indication. Amber for Trip indication. Red `ON' Green `OFF' Spring charge indication. Auto trip indication. 1 No. hooter with hooter acceptance and reset push button. 1 No. master trip relay. ( Electromechanical Type) 1 No.Trip ckt supervision relay (Electromechanical Type) 1 Set of fuses, ferrules, wiring etc. as required. 3 No. VA33 auxiliary relay for transformer fault, alarm and trip. 12 Annunciator window for all electrical and transformer fault. Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate 1 Set of Power Pack 110 Volt A.C. / 24 Volt D.C.complete as required. H.T. Panel describe as above |
| 121 | TRANSFORMERReparing, servicing, storing, inspection, handling, assembling, installing of 400 KVA X 2 transformers in correct aligned position effecting proper connections, testing, commisioning etc. complete in all respect. 11 KV/415 V 400 KVA of load tape chamber. a) Cable Termination box with disconnecting facility for 11 KV 3C-240 sq mm XLPE cable at 11 KV side b) In LT side provision for bus truncking system from LT of transformer to LT Panel.c) Off Load Tap Changer on HV side + 7.5 % to - 7.5 % @ 2.5 % in manual mode with position indicator and locking arrangements. d) Unidirectional rollers. e) Oil Conservator with filter cap, drain plug & oil level gauge f) Earthing terminals 2 nos for body earthing. g) 0.415 KV neutral seperately bought out on a bushing for neutral earthing. h) Pressure release device. Double diaphragm explosion vent. i) Radiators Detachable type with top & bottom shut off valve. j) First filling of filtered dehydrated oil as per IS : 335 including make up fill during installation. k) Silica gel breather with connecting pipe & oil seal. l) Rating, Diagram & Terminal marking plate of SS. m) Sampling Valves for filteration, drainage and filling with plugs. n) Air release plugs. o) Thermometer pocket with plug. p) Lifting Lugs. q) Buchholz relay with gas release cock, alarm & shut off valve with separate set of contacts for trip and alarm. r) 150 mm Winding temperature indicator (WTI) with alarm. s) 150 mm Oil temperature indicator (OTI) with alarmt) Marshalling Box. u) Clamping device. v) Jacking Pads. The work shall be carried out as per complete enclosed specifications and approved drawings. |
| 122 | Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 240 Sq. mm x 3 core, XLPE aluminiumconductor cable of 11 KV grade as required : |
| 123 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 300 Sq. mm x 3 core, XLPE aluminium conductor cable of 11 KV grade as required : Note - 1- Rates are inclusive of all taxes but excluding GST which shall be paid extra as applicable 2- Labour cess @ 1% will be deducted from contractor's bill at the time of payment Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |