| Sl. No. | Item Description |
| 1 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Hard rock (requiring blasting) |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] M-20. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR SUNSHADE] M-20. |
| 8 | Same as above item but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 9 | Same as above item but for slabs (Using 1:1.5:3 Mix concrete) |
| 10 | Same as above item but for R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 11 | Same as above item but for R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 12 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand). Ground Floor |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand). Ground Floor |
| 17 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick Double leaf |
| 18 | Same as above item but for Single leaf |
| 19 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 21 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 22 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 23 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 24 | Fixing of steel or wooden chaukhats in position. Door chaukhats |
| 25 | Fixing of steel or wooden chaukhats in position. Window chaukhats |
| 26 | Fixing of steel or wooden chaukhats in position. Ventilator chaukhats |
| 27 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 28 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand). |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand). |
| 30 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 31 | 25 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 32 | 40mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING] |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete |
| 36 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : [IN FLOORING] |
| 37 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING] |
| 38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 39 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 40 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 41 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 42 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . |
| 43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 44 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). |
| 45 | Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm |
| 46 | P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 250 mm x 10mm |
| 47 | P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. 150x10mm |
| 48 | Providing & fixing stainless steel door handles with screws and 150mm long.SI marked |
| 49 | S/F of glass strips for flooring.35mm wide & 4 mm thick |
| 50 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 51 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 52 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 53 | Providing and fixing bright/ matt finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 54 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 55 | Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wire aperture |
| 56 | Providing and fixing wire gauge shutters using With ISI marked stainless steel butt hinges required sizeof aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :32mm thick shutters With ISI marked stainless steel butt hinges of required size. Second class teak wood |
| 57 | Expension joint teatment with 1.02 mm thick aluminium sheet and 4 cm thick bitumastic sheet with hot bitumen of approved aulity. (As per Rate analysis & specification attached) HORIZONTAL EXPANSION JOINT |
| 58 | Providing & fixing aluminium sheet ,1.02 mm thick for Vertical expansion joint work including labour and all materials etc . Powder coated aluminium (minimum thickness of powder coating 50 micron) VERTICAL EXPANSION JOINT |
| 59 | Providing & laying cement concrete in 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggreagate 20mm nominal size) including supply of all materials,labour and T & P etc. required for completion of work and curing complete including cost of form work in foundation and floors |
| 60 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 61 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 62 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 63 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 64 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 65 | Chequerred precast cement concrete tiles 20 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 66 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood |
| 67 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 68 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 69 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edgesto give high gloss finish etc. complete at all levels. |
| 70 | Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete On steel work |
| 71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 72 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 73 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 74 | Providing and fixing anodised aluminium doors,having 2 mm thick Aluminium section excluding coating & an average coating of 20 micron fully glazed made of Aluminium door tube size 83.5x44.65 mm as Vertical member and 11.40x44.45mm size tube in bottom & horizontal members Door chaukhat ahould be ofAluminium tubler vertical with two openable shutter. The rate will include cost of material fixture 5mm glass handles,locks,screw necessary beeding & excluding cost of floor spring if requred for proper complection of work as per direction of Engineer-in-charge. With 5 mm thick glass |
| 75 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 76 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 77 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 78 | Supply and fixing M.S. Work in gate 'including all necessary for proper 'completion of the work. |
| 79 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 80 | Providing and fixing Alumunium sliding door bolts ISI marked to required colour or shade with nuts and screws etc. complete :300x16 mm |
| 81 | Providing and fixing Alumunium tower bolts with necessary screws etc. complete. 300 mm x 10mm |
| 82 | Providing and fixing Alumunium tower bolts with necessary screws etc. complete. 250 mm x 10mm |
| 83 | Providing and fixing Alumunium handles with screws etc. complete (a) 125 mm |
| 84 | Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work. |
| 85 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. |
| 86 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 87 | Aluminium sheet 26 gauge |
| 88 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 89 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 90 | Painting two coat synthetic enamel paint over priming coat on new wood surface up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area after and including preparation of surface by throughly cleaning oil, grease, dirt and foreign matters andscored by wire brushes fan steel wood rapers and preparing and knotting including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 91 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-roll |
| 92 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in require |
| 93 | First class brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc.AR |
| 94 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). |
| 95 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound |
| 96 | Supply of 110mm dia plain PVC.(6kg/sqcm) pressure. |
| 97 | Supply of P.V.C. soket 125mm dia. |
| 98 | Supply of end cap 110 mm dia. |
| 99 | Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete item. 30 metre B.G.L. |
| 100 | Beyond 30 metre. |
| 101 | Supply & fixing of nylon jalli around the slotted pipe complete as required. |
| 102 | Lowering of 110mm dia Rogid P.v.c. pipe in bore hole including cutting jointing etc. complete. |
| 103 | Providing & packing of coarse sand around the P.v.c.pipe. |
| 104 | Supply of 32mm dia G.i.pipe B class with required fitting. |
| 105 | Supply of India marka - II hand pump ISI marked with cylinder & connecting rods |
| 106 | Installation of India marka - II hand pump over the bore hole as per direction of E/I |
| 107 | Development of bore by manual labour till discharge of free from turbity complete item. |
| 108 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 109 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
| 110 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 111 | Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling. 16.6.1 With road roller/ hand roller |
| 112 | Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge 40/50 mm compacted thickness with bitumen of grade CRMB-60 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity |
| 113 | Distribbuting of Rubber & Sand in Artificial Turf |
| 114 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. |
| 115 | Electrical WorkWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 116 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 117 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 118 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 119 | Same as above item but for 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 120 | Same as above item but for 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 121 | Same as above item but for 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire |
| 122 | Same as above item but for 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 123 | Same as above item but for 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 124 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 125 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 126 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 127 | Same as above item but for 2 Way 5/6 amps switch |
| 128 | Same as above item but for Telephone socket outlet |
| 129 | Same as above item but for DATA outlet |
| 130 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 131 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 132 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module |
| 133 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 134 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 135 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 136 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 137 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 138 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 139 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 140 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 141 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 142 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 143 | Same as above item but for 6 way (4 + 18), Double door |
| 144 | Same as above item but for 8 way (4 + 24), Double door |
| 145 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.). 4 way Double door (4 + 12) |
| 146 | Same as above item but for 8 way (4 + 24), Double door |
| 147 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB |
| 148 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 149 | Same as above item but for Double pole |
| 150 | Same as above item but for Triple pole and neutral |
| 151 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 way, Double door TPN MCBDB |
| 152 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 153 | Supplying and fixing 40 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole |
| 154 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 155 | Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. |
| 156 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 157 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 158 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 159 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 160 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 161 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 162 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 163 | Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 164 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 165 | Supply of 26W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED26S 865 W7L120 PSU WH or equivalent. |
| 166 | Supply of 40W Smart Bright Linear provides an extremely durable and high efficacy yet cost effective linear solution surface mounted and suspended applications like offices, retail stores, metro stations, etc. similar to Philips SP095V LED40S 865 W7L120 PSU WH or equivalent. |
| 167 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 168 | Supply of Pressure die cast housing LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent. |
| 169 | Supply of Power Cables,Solid Aluminum conductor up to 10 sqmm balance stranded conductor,XLPE Insulated,cores laid up, PVC tape innersheathed, unarmoured/Armour (Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x16 sqmm, 3x10 sqmm & balance all galvanised steel strip),extruded PVC Type ST2 sheathed,650/1100V grade as per IS 7098(Part 1) 1988. 4CX6Sq.mm Cable |
| 170 | Same as above item but for 4CX16Sq.mm Cable |
| 171 | Same as above item but for 3.5CX35Sq.mm Cable |
| 172 | Same as above item but for 3.5CX50Sq.mm Cable |
| 173 | Same as above item but for 3.5CX95Sq.mm Cable |
| 174 | Same as above item but for 3.5CX150Sq.mm Cable |
| 175 | Same as above item but for 3.5CX240Sq.mm Cable |
| 176 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 177 | Same as above item but for 3½ X 35 sq. mm (32mm) |
| 178 | Same as above item but for 3½ X 95 sq. mm (45mm) |
| 179 | Same as above item but for 3½ X 240 sq. mm (62mm) |
| 180 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm |
| 181 | Same as above item but for 185 sq. mm and upto 400 sq. mm |
| 182 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 183 | Same as above item but for 185 sq. mm and upto 400 sq. mm |
| 184 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 185 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 186 | 3 Phase Input & 3 Phase Output 10KVA UPSSupply, installation, testing, and commissioning of UPS system with following features 1. High freq. PWM inverter using IGBT 2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack |
| 187 | Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) |
| 188 | Supplying installation testing and commissioning Recess Mount Downlighter Mollis Recess Downlighter 15W LED complete in all respect. |
| 189 | Supplying installation testing and commissioning of 450mm sweep 1500 RPM heavy Duty Exhaust Fan |
| 190 | Plumbing workProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 191 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid |
| 192 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 630x 450 mm with single 15 mm C.P. brass pillar tap. |
| 193 | Same as above item but for White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 194 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board of size 510x1040x200mm |
| 195 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 450x300x150 mm |
| 196 | Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 197 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 198 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 199 | Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
| 200 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe. 32mm dia |
| 201 | Same as above item but for 40mm dia |
| 202 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 203 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 204 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 205 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 206 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 207 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C /C.I. Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground). 110/75 mm diameter |
| 208 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall20mm dia nominal outer dia pipes |
| 209 | Same as above item but for 25mm dia nominal outer dia pipes |
| 210 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15mm dia nominal outer dia pipes |
| 211 | Same as above item but for 20mm dia nominal outer dia pipes |
| 212 | Same as above item but for 25mm dia nominal outer dia pipes |
| 213 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 .15mm nominal bore |
| 214 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 215 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931. 15mm nominal bore |
| 216 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 217 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 218 | Same as above item but for. 20 mm dia nominal bore |
| 219 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 75 mm O.D. |
| 220 | Same as above item but for 110 mm O.D. |
| 221 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 222 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 75 mm |
| 223 | Same as above item but for Size 110 mm |
| 224 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 75/90 mm |
| 225 | Same as above item but for Size 110 mm |
| 226 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 75x75x75 mm |
| 227 | Same as above item but for Size 110x110x110 mm |
| 228 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 75 mm |
| 229 | Same as above item but for Size 110 mm |
| 230 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm |
| 231 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler. 110 mm |
| 232 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree. 110 mm Bend |
| 233 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain). 110 mm Shoe |
| 234 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 235 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 236 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 237 | Fire SystemSITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex) |
| 238 | SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree /CRC) |
| 239 | SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex) |
| 240 | SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle |
| 241 | Providing and fixing MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) 100mm dia |
| 242 | Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories. |
| 243 | Supply of Fire Man Axe. |
| 244 | Providing and fixing weather proof standard Fire Duct Door complete in all respect for internal. |
| 245 | SITC of Air cushion Tank (2000x1000)mm. |
| 246 | SITC of Air Release Valve. |
| 247 | Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. 150 mm |
| 248 | SITC of Butterfly Valve complete with all respect. 150 mm |
| 249 | Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock |
| 250 | Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 2 way |
| 251 | Supply and fixing of ABC type (4 kg.) ISI Marked 1131 |
| 252 | Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked 1132 |
| 253 | Supply and fixing of self glow type exit signage |
| 254 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Per liters capcity. |
| 255 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m depth. Pipes 80 mm to 300 mm diameter |
| 256 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered). Depth not exceeding 1.5 meter |
| 257 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 258 | Same as above item but for 250 mm. dia. RCC Pipes |
| 259 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. |
| 260 | Same as above item but for 250 mm. dia. |
| 261 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line |
| 262 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 150 |
| 263 | Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 150. (i) For Sewer Line |
| 264 | Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 150 |
| 265 | Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 266 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: |
| 267 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 268 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 80 mm nominal dia Pipes |
| 269 | Same as above item but for 50 mm nominal dia Pipes |
| 270 | Same as above item but for 32 mm nominal dia Pipes |
| 271 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32mm nominal bore. |
| 272 | Same as above item but for 50 mm nominal dia Pipes |
| 273 | Same as above item but for 80mm nominal bore. |
| 274 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 275 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth. Pipes 80 mm to 300 mm diameter |
| 276 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 277 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design. 150 mm. dia. |
| 278 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 150 (i) For Sewer Line |
| 279 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 280 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: |
| 281 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 282 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 283 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size) |
| 284 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 285 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 286 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 287 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 288 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 289 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 290 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 291 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge. |
| 292 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 293 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 294 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) |
| 295 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 296 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 297 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil. 350 mm dia |
| 298 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders . 350 mm dia |
| 299 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 300 | `Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. |
| 301 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in- charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm. |
| 302 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia |
| 303 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 304 | Supplying & Installation of suitable Hp submersible pump B.S or K.S.B or equivalent make with finolex cable 1x3x2.5 squmm(upto 75mtr) withflexible conduit25mm dia, electrical out door pannel with required electrical fitting such as MCB of 0-25Amp (Havell or Indocopp or MDS make), Volt & Ampere meter (AE make), single phase preventer (Minilac or VSP -1 make) starter (L&T or BCH make) etc of approved make, 40mm HDPE Pipe (25 mtr) and all accessories complete as per requirement of site. NOTES- a) Contractor shall include the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual. b) Contractor to select suitable HP of pumps . c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level in overhead domestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps. |
| 305 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 306 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 307 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 308 | The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.interlocking, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification.Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases or mention as mention in BOQ. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMING- 1 Nos. 400 Amp FP MCCB , 1 Nos. 125 Amp ACB BUSBARS- 1 Nos. 500 Amp TPN busbars of aluminium alloy as per SLD. AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's. Load Management through PLC Contactor for Load Management System Buscoupler switching. Interlocking. OUTGOING- 4 Nos. 125 Amp TP MCCB, 4 Nos. 63 Amp TP MCB & 3 Nos. 40Amp TP MCB INSTRUMENTS- 3 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers. 3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 3 Sets auto trip indicating lamp . Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. |
| 309 | Supply installing testing & commissioning of out door type street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below. Incoming : 63 Amp. 10 KA FP MCCB 1 No.Suitable contractor and timer for down & dusk 100 Amp. TPN Alu. Bus barOutgoing : 25 Amp. 10KA DP MCB 6 No. |
| 310 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. |
| 311 | Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.(Ed e Plus LED Streetli ht) |
| 312 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 313 | Supply installing testing & commissioning of LED Bollard offers a high level of durability with high impact resistance. It is easy to install, comes with ingress protection and provides comfortable soft lighting BGBOL 605 9W LED LED BOLLARDS |
| 314 | Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 2 X 6 sq. mm |
| 315 | Same as above item but for 4 X 10 sq. mm |
| 316 | Same as above item but for 3½ X 50 sq. mm |
| 317 | Same as above item but for 3½ X 120 sq. mm |
| 318 | Same as above item but for 3½ X 150 sq. mm |
| 319 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 sq. mm |
| 320 | Same as above item but for 95 sq. mm and upto 185 sq. mm |
| 321 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 322 | Same as above item but for 95 sq. mm and upto 185 sq. mm |
| 323 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 324 | Same as above item but for 95 sq. mm and upto 185 sq. mm |
| 325 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 326 | Same as above item but for 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 327 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 Core 6 sq.mm |
| 328 | Same as above item but for 3½ X 50 sq. mm |
| 329 | Same as above item but for 3½ X 120 sq. mm |
| 330 | Same as above item but for 3½ X 150 sq. mm |
| 331 | D.G. SET Supplying fixing and commissioning of SILENT (Canopy design) water cooled DG Set with electronic governer with one Diesel Engine with rated capacity (mentioned below) at 0.8 P.F. 1500 RPM, 4 stroke multi-cylinder coupled to brush less type 415 volts 50 cycle/ second self exited alternator completed with cushy pads. Domestic silencer exhaust pipe complete with Alternator auxiliaries, Radiator, 24 volts chargeable battery including initial charging of batteries. suitable for synchronizing complete as per specification. 200 KVA |
| 332 | TransfermerProviding, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and Off Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards OFF load tap changing range steps -10% to 5% on H.V in steps of 2.50% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2. 1. Coservator with plain oil level gauge and oil drain plug 1nos. 2. Top filter valve 1 Nos. 3. Bottom filter-Cum-drain valave 1Nos.. 4. Rating and diagram plate 1nos. 5. Earthing Terminals 2Nos. 6. Thermometer pockets 1Nos. 7. Lifting Lugs 2/4 Nos. 8.Air release plug 2/4 Nos. 9. Bi-directional rollers 4Nos. 10.Jacking pads 1Nos. 11.Presure relese valve 1Nos. 12. Separate Bare LV neutral 433V 13. Detachable/Fixed type radiators 1Nos. 14. Magnet Oil level gauge 15. Oil temperature indicator 1Nos. 16. Winding temperature indicator 1Nos. 17. Marshlig Box single window 1No. 18. Double flot buchholz's relaywith alarm and trip contact. COPPER WOUND 200KVA 11/.433V Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail