Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-04-2026 | Corrigendum No.1 | BOQ | 23-04-2026 |
| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR NAME OF WORK: ADDN/ALTN TO BLDG NO P-6 UNDER PARA 35 OF DWP AT HQ NORTHERN COMMAND UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-11 /2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 5 | Preparing of concrete surfaces on slabs, chajjs by Chipping away loose, spalled, or carbonated concrete until sound concrete is reached, expose corroded reinforcement fully; remove rust using a wire brush or mechanical means.Clean the substrate with a high-pressure water jet to remove dust and oil. Apply a rust remover followed by an anti-corrosive primer (Dr. Fixit Epoxy Zinc Primer). Install watertight, rigid shuttering to prevent leakage and ensure the desired profile. Laying micro concrete up to the required thickness on the designated area with proper shear connector and bonding agent while the surface is \\"SSD\\" (Saturated Surface Dry). Make : Dr. Fixit 208 Micro Concrete/Ultratech microkrete. The concrete thickness varies from 15mm to 35mm |
| 6 | Excavating over area, not exceeding 1.5 m depth; for foundation, etc. and getting out in any type of soil, complete all as specified and as directed. |
| 7 | Excavation in trenches in any type of soil not exceeding 1.50 m wide and not exceeding 1.50 mtr in depth and getting out for pipe, cable pole, stay etc, all as specified and directed |
| 8 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed. |
| 9 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. |
| 10 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed |
| 11 | M&L for Reinforced cement concrete , Type B1 1:2:4(20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed |
| 12 | M&L for Reinforced cement concrete , Type B1 1:2:4(20 mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as directed |
| 13 | M&L for Reinforced cement concrete , Type B1 1:2:4(20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 14 | M&L for Reinforced cement concrete , Type B1 1:2:4(20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed |
| 15 | TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed. |
| 16 | TMT mild steel bars, 5mm dia and over upto and incl 10mm dia , as in stirupps cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , all as specified and as directed. |
| 17 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including rough finished flat surfaces of concrete, complete all as specified and as directed. |
| 18 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished surface of flat concrete complete all as specified and as directed. |
| 19 | Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed. |
| 20 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed. |
| 21 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C.Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. The finished surface will be treated with 2 coats of aluminium paint. |
| 22 | Anti Termite treatment in the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. |
| 23 | Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed. |
| 24 | Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed. |
| 25 | M & L Rendering 15 mm thick on brick or concrete surfaces of walls in CM (1:4) mixed with water proofing compound including finishing the surfaces fair and even without using extra cement all as directed |
| 26 | Supply only Integral water proofing compound, complete all as specified and as directed. |
| 27 | M&L for preparation surfaces on walls/ceiling by mechanical scraping, Intense sanding, filling the cracks with smart care crack seal and applying 2 coats of SmartCare Damp Proof paint over a coat of self priming coat complete all as specified and as directed. |
| 28 | Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 29 | M&L for PCC 1:2:4, type B-2 by using 40 mm graded stone aggregate as in sub base floor complete mixed with polyester triangular fibres all as specified and as directed. (Polyester triangular fibres shall be measured and paid separately) |
| 30 | Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars complete all as specified and as directed. |
| 31 | Polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50kg per sq. m complete all as specified and as directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 33 | Providing and injecting Antitermite Treatment of soil under existing floors using emulsion @ 1 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand to match the existing floors complete all as specified and as directed by Engr-in-Charge.Note : The treatment work shall be carried through authorised agency only, and certificate for the same for waranty shall have to be furnished before submitting payment) |
| 34 | Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: 450 mm Finished Floor Height (FFH). (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100 mm x 100 mm x 3 mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16 mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as specified and as directed by the Engineer-in-charge. |
| 35 | Cont.. srl item No. 33(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1 mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 kgs applied on area 25 mm x 25 mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. Colour and pattern of the flooring will be approved by GE. |
| 36 | M & L Glazed Vitrified tiles any Shade 7-8mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exc 1.00 Sqm, in floors, walls etc. laid over 8-10 mm thick polymer modified tile adhesive complying to Type 2 as per IS 15477:2019 with Joints of tiles made with spacer of 3 to 5mm shall be grouted with solid epoxy grout TileFixoStyle of Ultratech/SP-100 Duo of Myk Laticate/Gresbond KE-100 of Kajaria of desired shade. |
| 37 | M & L for 7-8mm thick Non skid maxgrip vitrified tiles, coloured, (square/rectangular) area of tiles exceeding 0.18 sqm but not exceeding 0.36 sqm of first quality, of shade as decided by GE, shall be laid over 8-10 mm thick polymer modified tile adhesive complying to Type 2 as per IS 15477:2019 with Joints of tiles made with spacer of 3 to 5mm shall be grouted with solid epoxy grout TileFixoStyle of Ultratech/SP-100 Duo of Myk Laticate/Gresbond KE-100 of Kajaria of desired shade. |
| 38 | M&L for Glazed ceramic tiles (Digital/HD polished) as in skirting /dado conforming to IS-13712 of 1993 of size 300x600mm, or as directed by GE, thickness not less than 6 to 7mm, of grade B-IIa, laid over and including 6-8 mm thick polymer modified tile adhesive complying with Type 2 as per IS 15477: 2010 and with Joints of tiles made with spacer of 3 to 5mm shall be grouted with solid epoxy grout TileFixoStyle of Ultratech/SP-100 Duo of Myk Laticate/Gresbond KE-100 of Kajaria of desired shade matching with the floor complete all as directed. |
| 39 | 25mm thick cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in floor and finished even and rough to receive tiles without using extra cement complete all as specified and directed. |
| 40 | M&L for 400x400x11mm thick heavy duty designer vitrified parking tiles laid over 8-10mm thick polymer modified adhesive (Type III), joints grouted with solid epoxy grout polymer complete all as specified and directed |
| 41 | S&F granite stone 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick layer of cement mortar 1:3 after roughening of existing concrete surface and applying a layer of neat cement slurry @ 3Kg/Sqm including pointing in white cement 1:2 using marble dust with admixture of pigments to match with shade of stone. laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 42 | Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed |
| 43 | M&L providing and fixing wall panelling of Premium UniAcoustic 12mm Uni-vicstrip in size: 600mm*2400mm,Shade as per direction of GE as in wall panelling complete all as directed. |
| 44 | M&L providing and fixing wall panelling of metallic acoustic designer including necessary fixing arrangements,Shade as per direction of GE. It comprises of :1) Factory made removable type Modular Metal Panelling system. The front sheet shall be constructed from preformed textured hot-dip galvanized metal with a rigid polyvinyl-chloride (PVC) film on one side and a rust-resistant coating on the other side. The sheet thickness shall be no less than 0.6mm. The overall system thickness shall range between 80-90mm.The metal panelling / partition shall be Greenguard Gold Certified from (UL / Intertek).2) The structural framework shall include vertical tubular galvanized iron (GI) pipes securely installed between top and bottom GI frames.3) The proposed non perforated wall panelling tiles shall be Class A certified as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. |
| 45 | Cont.. srl item No. 434) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the Control room it is necessary that the wall panelling shall have micro-perforations (less than 1.6mm diameter each) atleast 25% of the panelling area with a density of 5000 holes per square feet. UL audit certified design feature on modular wall panelling tile having clean perforations and providing smooth finish on front fascia of tiles. The tile shall have 5000 holes per square feet on front side of the tile. 5) The wall panelling shall be robust & strong enough to sustain the routine loads/minor impacts of typical Control room environment. The wall panelling/partition structure shall have UL audit certified feature of Load bearing capacity of 300 Kgs to hold any display unit on clamp having minimum length of 750mm. 6) The modular metal wall partition shall meet the fire resistance rating criteria of 60 minutes with respect to Thermal Insulation (I), Integrity (E), and Stability (R). The fire resistance test must be conducted by UL/Intertek/ an authorized Fire Research Laboratory under the Government of India. . |
| 46 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and as directed. |
| 47 | M&L providing and fixing Decor Slim Stone, natural Stone Veneer (Slate/Quartzite) with Metallic Pigments, Glass Fiber Reinforced Polyester (GRP), water proof and fire resistant minimum thickness 1.5mm to 3mm , Textured/Grit finish with reflective metallic shine, fixed with Kerakoll super flex eco silicon adhesive and backing with minimum 10 mm thick heavy duty Fibre Cement (made with Hatchek process/HPSC technology) complete all as specified and directed |
| 48 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. |
| 49 | Cont.. srl item No. 47GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm(both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber fleece. |
| 50 | Factory made acoustic modular metal false ceiling of powder coated panels. Make shall comprise of perforated and nonperforated metal panels made through CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of approved powder coating finish. Panels shall be designed to achieve shape and design as per the design consultant with the combination of acrylic panels with lights, designed to enhance visual feel, with provision for easy installation and maintenance, integrated lighting and scope for integration of building services like HVAC and fire detection/ fighting system. The designer metal ceiling shall be greenguard gold tested/certified (from UL/Intertek). Metal modular false ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90. The metal ceiling shall sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations or better. The test shall be carried out by authorized government agency. Structure shall be made from heavy duty powder coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm). |
| 51 | 10-12mm thick perforated gypsum boards as in ceiling as approved, moisture resistant, including intermediate, perimeter channel wall channel, along with nuts and bolts connecting plates for gypsum boards, dry wall screws soffits cleats, panelling section, rowel plugs fixtures and screws and applying two coats of emulsion paint over a coat primer on exposed surface, complete all as specified and as directed by Engr - in - Charge. Note: (a) Design of paneling board as approved by Engr - in - Charge(b) GI grid/hanging system shall be of same make as of false ceiling manufacturer. |
| 52 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , all as specified and directed. |
| 53 | Description all as per item No. 100 above but area exceeding 1.50 square metre and not exceeding 4 square metre each. |
| 54 | Providing and fixing factory made uPVC colored Sliding window of area not exceeding 2 sqm, Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : Touch Lock of zinc alloyed ( powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock. |
| 55 | Supply and fixing factory made uPVC coloured fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.)comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality and complete all as specified and as directed. |
| 56 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 57 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge |
| 58 | 12 mm thick toughened glass door with and including heavy duty floor spring top hinge including pivot clamps, side locking arrangement , stainless steel 300 to 400 mm long handles, complete all as specified and as directed. |
| 59 | M&L for Sheet glass, 4.8mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 60 | M&L for Sheet glass, 4.8mm thick, ground or obscured or frosted, on one side and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 61 | M&L for first class hard wood plain solid straight chowkats and frames and Design main doors Pannel shutter with wrought frmed on the solid rounded or chanbered put together with glue and pinned at joints including preservative treatment complete all as specified and as directed. |
| 62 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 63 | Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed |
| 64 | M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed. |
| 65 | M&L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with particle board core, with 2, 4, or 6 raised panel design with but 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification. |
| 66 | Extra over flush shutters, any thickness, for vision panels or peepholes, square or rectangular including lipping(supplying and fixing of glass measured separately) complete all as specified and as directed. |
| 67 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed. |
| 68 | 18/19mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading near PVC bending tape of same shade all around complete all as specified and as directed. |
| 69 | 12mm thick Plywood, grade BWP, type BB, fixed with screws to timber frame work, complete all as specified and as directed. |
| 70 | 1.5 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and as directed. |
| 71 | 100mm Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and as directed. |
| 72 | 150 mm length Brass handles, cast type, polished bright Extruded brass handles, fabricated type polished, complete all as specified and as directed. |
| 73 | 150mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed. |
| 74 | S&F 3D adjustable concealed hinges of premium quality Kg as approved by Engr in Charge complete all as specified and as directed. |
| 75 | S&F recessed/integated handle (flush handle or groove handle) of premium quality as approved by Engr in Charge complete all as specified and as directed. |
| 76 | S&F 18 inch SS, Titanium Gold Round Barn Door Handles Heavy Duty |
| 77 | S&F conealed door closure of premium quality as approved by Engr in Charge complete all as specified and as directed. |
| 78 | S&F magnetic lock & controller of premium quality as approved by Engr in Charge complete all as specified and as directedm. |
| 79 | S&F acoustic and fire seal to reduce noise as approved by Engr in Charge complete all as specified and as directed. |
| 80 | Supply and Fixing brass mortice lock four levers vertical type size 100mm or above complete all as specified and as directed. |
| 81 | S&F Venetian blinds of approved make, Horizontal or vertical or type using 100mm wide fabric blinds of approved colour/ shade and pattern including operating arrangement such as chord/ thread, rolling arrangement/roller, counter weight, connecting chain etc., and necessary fittings complete all as specified and directed. |
| 82 | 5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 83 | Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 84 | Vitreous china wash basin, pedestal type, white flat back size 500 x 435x185mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and incl PVC waste pipe 32mm dia & CP grating with holes fixed in repairs complete, all as specified and as directed |
| 85 | S&F Floor-mounted or wall-mounted vanity assemble including a wash basin, cabinet, and framed mirror complete, all as specified and as directed. |
| 86 | S&F 5 mm thick looking mirror of required size, fixed on walls with dash fasteners and chromium plated screws purposefully made to fix the glass by drilling hole in the glass complete all as directed. |
| 87 | Vitreous China wall mounted water closet size 380x670x765mm, coloured (Colour as approved by Engineer-in-Charge), including S-Trap, cistern, 300mm, seat cover and internal fittings-dual flush, fixing in repair complete all as specified and as directed |
| 88 | 15mm bore centre hole basin mixer without Popup waste system with 450mm long braided PVC hoses, fixed in repairs, complete all as specified and as directed |
| 89 | Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed. |
| 90 | Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed. |
| 91 | Vitreous China urinals, half stall (back or corner wall type) white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repairs, complete all as specified and directed. |
| 92 | S&F concussive push button taps auto closing concealed urinal flush valve with wall flange PRS-CHR-073 of chromium plated , screwed for iron pipe and fixed complete all as specified and as directed. |
| 93 | Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed. |
| 94 | Health faucet ABS body with wall hook and 1 mtr chrome plated PVC hose pipe, fixed in repairs, complete all as specified and as directed |
| 95 | S&F chromium plated toilet paper holder complete all as specified and directed. |
| 96 | Fancy towel rail 600mm long,brass chromium plated, complete all as specified and as directed. |
| 97 | Soap dish holder, fixed in repairs, complete all as specified and as directed. |
| 98 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed. |
| 99 | PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified. |
| 100 | 15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed. |
| 101 | 20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed. |
| 102 | 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 103 | 110mm PVC (SWR) bends any radius fixed in repairs, complete all as specified and directed. |
| 104 | 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with excess door fixed in repairs, complete all as specified and directed. |
| 105 | S&F PVC (SWR) Floor trap, 75 mm dia of outlet, plain with grating including jointing with solvent cement and making good all as directed |
| 106 | M&L for preparation of newly steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 107 | M&L for prepartion of old steel surfaces by complete removal of existing treatment if any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed. |
| 108 | M & L for applying 1 mm thick layer of wall putty on walls to give uniform surface, surface scrubbed with emery paper and make surface good and clean complete all as specified and directed. |
| 109 | M&L for two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed. |
| 110 | Material & Labour for preparation of surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 111 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed. |
| 112 | Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls complete all as specified and directed |
| 113 | Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified and directed. |
| 114 | Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistranded) PVC insulated and unsheathed in and including PVC concealed conduit pipe as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall /ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white /colour wash complete all as directed. NOTE: Continuous earth wire of Green colour should be provided at each point with 1.5 sqmm FRLSH copper conductor cable of 1100 V grade up to ceiling rose/light fitting etc all as Specified & Directed by Engr- In-Charge.. |
| 115 | All as per items No 113 above but cable 2.5 Sqm FRLSH for one 3/5 pin 6Amp socket outlete point on an independent board. |
| 116 | All as per items No 113 above but cable 2.5 Sqm FRLSH for one 3/5 pin 6Amp socket outlete point on the same board with other switch. |
| 117 | All as per items No 113 above but one ball/buzzer point controlled by one ball push single pole one way. |
| 118 | All as per items No 113 above but for one 3/6 pin 16 Amps socket outlete point on an independent board with cables of size 2.50 sqm. |
| 119 | All as per items No 113 above but an independent board with cables of size 4.0 sqm. |
| 120 | S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer cover complete all as specified and directed. |
| 121 | S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed. |
| 122 | S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer cover complete all as specified and directed. |
| 123 | Material and labour for supply and fix floor mounted metal socket outlet box of size 400MmX400MmX65-90mm, made of die-cast aluminium / stainless steel body with hinged flap type cover, , complete with modular type switch socket outlets etc and all necessary accessories, complete in all respects.Note :- (a) The item shall include:Heavy duty floor box with hinged cover and locking arrangement 4 Nos. 16 Amp, 250V, 3-pin modular socket outlets with control switches 4Nos of 16 Amp, 250V, 3-pin modular switch, 4 Nos telephone socket fix in floor by cutting/recessing in PCC/finished flooring all as specified and directed by Engr-In-Charge. |
| 124 | S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed. |
| 125 | Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and as directed. |
| 126 | S&F in replacement electronic step type fan regulator 100 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and directed. |
| 127 | S&F in replacement telephone socket double suitable for RJ-11 fixed with modular box along with frame complete all as specified and directed. Make: Havells Crabtree/ Legrand/ Indoasian.Note:- Modular box, Modular plate cover is included in the quoted rate. |
| 128 | S&F in replacement TV Co- axial socket complete all as specified and directed. |
| 129 | S&F in replacement Sheet metal enclosure double door type for MCCB VTPN DB upto 8 way vertical type 415 volts with suitable busbar and neutral link,chases wall for fixing DB and making good distributed wall surfaces to match with existing specification for provn of 160 amps Amp 4 Pole MCCB complete all as specified and directed. |
| 130 | S&F in replacement Sheet metal enclosure double door type for MCCB VTPN DB upto 4 way vertical type 415 volts with suitable busbar and neutral link,chases wall for fixing DB and making good distributed wall surfaces to match with existing specification for provn of 160 amps Amp 4 Pole MCCB complete all as specified and directed. |
| 131 | S&F in replacement Sheet metal enclosure double door type TPN 4 way vertical type 415 volts with suitable busbar and neutral link,chases wall for fixing DB and making good distributed wall surfaces to match with existing specification for provn of 160 amps Amp 4 Pole MCCB complete all as specified and directed. |
| 132 | MCCB 160 Amps, 4 pole 25KA , 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed. |
| 133 | MCCB 125Amps, 4 pole 25KA , 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and directed. |
| 134 | Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.(Note: MCBs will be measurd separately). |
| 135 | S & F in replacement MCB Single pole and neutral 240 volt any rating 40amps\\"C\\" series, with rupturing capacity 10 KA complete all as specified and directed. |
| 136 | S & F in replacement MCB single pole 240 volt any rating from 6 to 32 amps \\"C\\" series, with rupturing capacity 10 KA ,complete all as specified and directed. |
| 137 | S & F in replacement MCB TPN 240 volt any rating 100 Amps \\"C\\" series, with rupturing capacity 10 KA ,complete all as specified and directed. |
| 138 | S & F in replacement MCB TP 240 volt any rating 100 Amps \\"C\\" series, with rupturing capacity 10 KA ,complete all as specified and directed. |
| 139 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete with all accessories as specified below :- Rated Wattage: 36 Watts SizeSize: 600mm x 600mmInput Voltage: 220–240 Volts AC, 50 HzType: Edge-lit / Back-lit LED panel, slim designLuminous Efficacy: Minimum 100 lumens per wattColour Temperature (CCT): Cool White (6500K) / Neutral White (4000K) as specifiedPower Factor: ≥ 0.95THD: ≤ 10%Driver: Inbuilt constant current LED driver, BIS approvedBody: Powder coated CRCA sheet / Aluminium housingDiffuser: High transmission opal acrylic / polycarbonate diffuserProtection: IP20 or betterLife Span: Minimum 50,000 burning hoursWarranty: Minimum 2 yearsNote:- Quoated rate includes cutting of false ceiling if required, making good damages, connection with existing wiring, earthing, testing and commissioning complete in all respects. |
| 140 | Supply, installation, testing and commissioning of 10 Watt LED bulkhead light fitting, suitable for wall/ceiling mounting complete with all accessories as specified below :Rated Wattage: 10 WattsType: LED bulkhead, round/oval shapeInput Voltage: 220–240 Volts AC, 50 HzLuminous Efficacy: Minimum 100 lumens per wattColour Temperature (CCT): Cool White (6500K) / Neutral White (4000K) as specifiedPower Factor: ≥ 0.95THD: ≤ 10%Driver: Inbuilt constant current electronic LED driver, BIS approvedBody: High grade polycarbonate / die-cast aluminium housingDiffuser: Opal / frosted polycarbonate diffuserProtection: IP54 or better (suitable for damp areas)Mounting: Surface wall/ceiling mountingLife Span: Minimum 30,000–50,000 burning hoursWarranty: Minimum 2 years |
| 141 | S& F in replacement LED tube light fittings of 20 wattage including rawl/plug ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr fixed to wall firmly , complete all as specified and directed.Rated Wattage: 20 WattsType: Integrated LED Tube Light fitting (4 feet)Input Voltage: 220–240 Volts AC, 50 HzLuminous Efficacy: Minimum 100 lumens per wattColour Temperature (CCT): Cool White (6500K) / Neutral White (4000K) as specifiedPower Factor: ≥ 0.95THD: ≤ 10%Driver: Inbuilt constant current electronic driver, BIS approvedHousing: Aluminium extruded body with opal diffuserMounting: Surface / Batten typeProtection: IP20 or betterLife Span: Minimum 50,000 burning hoursWarranty: Minimum 2 years Note:- Quoated rate includes cutting of false ceiling if required, making good damages, connection with existing wiring, earthing, testing and commissioning complete in all respects. |
| 142 | Supply and fixing LED luminaire 12 watt, 220 V AC recess/surface mounted downlighter type with high efficiency PC diffuser soft light and symmentrical illumination complete with driver, holders & LED lamp warm white suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 143 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed |
| 144 | S&F of decorative wall mounting 1X9W fixture with frosted glass along with 9W warm white bulb GLS lamp luminaire complete all as specified and directed by Engineer-in-Charge. |
| 145 | Supply, installation, testing and commissioning of 200mm sweep exhaust fan, BLDC motor operated, suitable for wall mounting in toilet, complete with all accessories as specified below:Sweep Size:200 mm ,Motor Type: BLDC motor, Power Consumption: Approx 6–8 WattsSpeed: Approx 2000 RPM Input Supply: 220–240 Volts AC, 50 HzNoise Level: Low noise type Body: High grade ABS / Polycarbonate body, glossy finishBlades: Aerodynamically designed plastic bladesMounting: Suitable for wall mounting with round cut-out approx. 200-220mmSafety: Inbuilt thermal overload protectionProtection: IPX4 Warranty: Minimum 2 years Including cutting of wall, making good damages, fixing with screws, connection with existing wiring, providing PVC flexible pipe if required, testing and commissioning complete in all respects all as specified and direceted by Engr-in-charge. |
| 146 | Supply, installation, testing and commissioning of ceiling mounted PIR dual tech 360 digree sensor occupancy sensor, suitable for corridor ,hallway ,stairecases for controlling LED light fittings, complete as specified below...Type: Ceiling recessed / surface mounted PIR sensorOperating Voltage: 220–240V AC, 50 HzLoad Capacity: Min 1000 Watts (LED compatible)Detection Range:8-12 metresDetection Angle: 360° Time Delay: Adjustable (30 sec to 5 min or more)Lux Control: Adjustable daylight sensitivityMounting: Recess / surface type as specifiedProtection: IP41 or betterWarranty: Minimum 2 yearsNotes:-Quoted rates shall be Including connection, setting, testing and commissioning complete in all respects all as specified and directed by Engr-In-Charge. |
| 147 | Sub main wiring with copper conductor cable (2 runs of cable) multistranded 2.5 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealled conduit not less than 25 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories for round ceiling light/round ceiling light recessed type/ foot lamp/focus light/ 2x2 panel light such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 1x2.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, including taking down old sub main wire, complete all as specified and directed.Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit. |
| 148 | All as per item No. 146 above but 2X4 Sqmm and 1X 4 Sqmm for Earth wire |
| 149 | All as per item No. 146 above but 2X 6 Sqmm and 1X 6 Sqmm for Earth wire |
| 150 | All as per item No.146 above but 4X16 Sqmm and 2X 16 Sqmm for Earth wire |
| 151 | Supplying, installing, testing and commissioning of 1200 mm sweep, 230V, 50Hz, IoT enabled BLDC ceiling fan complete , power consumption not exceeding 35W at full speed, minimum , 5-star rated as per Bureau of Energy Efficiency, including down rod, canopy, shackle, mounting accessories, connection with existing wiring, testing and commissioning complete as required Power factor >0.95 downrod type suitable for ceiling installation ,Speed min 300 RPM complete all as specified and Directed by Engr-In-Charge. Note- (i) Warranty 3 years overall on fan & 5 years on BLDC Motors (ii) Rates shall includes all leads & mounting hardware testing,commisioning integration with existing Wifi |
| 152 | Supply, installation, testing and commissioning of water Storage Type Electric Water Heater (Geyser) 10 Litre capacity, suitable for bathroom use, complete with all accessories as specified below:Capacity: 10 LitresType: Instantaneous / Mini storage typePower Rating: 2 kW (approx.) Input Supply: 230 Volts AC, 50 Hz, Single PhaseHeating Element: Heavy duty copper / glass coated heating elementTank: Pressure type inner tank with anti-corrosion coatingBody: ABS / Rust proof outer body Working Pressure: min 6–8 barSafety Features:Inbuilt thermostat,Thermal cut-out,Multi-function safety valve,Pressure relief valve,IP Protection: IPX4 or better,Mounting: Wall mounted type,Warranty: Minimum 2 years on product and on tankNote:- Quoted rate Includes providing and fixing necessary inlet and outlet connections PVC Pipes , CP brass nipples, connection to existing water supply line, connection to electrical point, testing and commissioning complete all as specified and directed by Engr-In-Charge. |
| 153 | Supplying and install Heavy Duty cable tray (SRFL100G) ,hot-dip galvanised mild steel , with size 100MMX50MM and 0.9mm thick ness. , complete with bends, tees, reducers, cross members, couplers, and all necessary accessories.The tray shall be hot dip galvanized after fabrication with zinc coating not less than 120 microns (or as specified), fixed on walls/ceiling with M.S. angle iron supports, threaded rods, clamps, anchor fasteners, including painting of supports with one coat of red oxide primer and two coats of synthetic enamel paint of approved shade complete all as specified and directed. Note :- (a) Drilling, cutting and welding as required Fixing with dash fasteners / anchor bolts Earthing of cable tray with 25x3 mm GI strip along with cable tray is included in the quoted rate of the items. (b) Cost is included for L supports for wall with all accessories such as nut ,bolt ,washers etc.(c) All major and minor spares are required in laying of cables and fixing of cable trays which are not mention above are included in the quoted rates.d) All meterial such as cement ,concerete,tiles etc to make wall/roof /ground in its original shape after fixing of cable trays shall include in the quoted rates of the items. |
| 154 | GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed. |
| 155 | M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 40mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed. Note:- All the joints shall be made with welding to get proper conductivity. |
| 156 | M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed. Note:- All the joints shall be made with welding to get proper conductivity. |
| 157 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :-(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. |
| 158 | Note itenm no-155 to 156:-Contractor Shall provide earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Eart pit No, Location, Earthing test Value and date complete all as directed. |
| 159 | Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above round complete all as specified and directed. |
| 160 | GI strip 32 x 6mm buried in ground alongwith saddle and fixing screws etc. for roof conductors and down conductors above ground complete all as specifed and directed. |
| 161 | Supply, installation, testing and commissioning of 150mm sweep inline duct exhaust fan, BLDC motor operated, suitable for wall mounting ,complete with all accessories as specified below:Sweep Size:150 mm ,Motor Type: BLDC motor, Power Consumption : Approx 70 WattsSpeed: Approx 5400 RPM Input Supply: 220–240 Volts AC, 50 HzNoise Level: Low noise type Body: High grade ABS / Polycarbonate body, glossy finishBlades: Aerodynamically designed plastic bladesMounting: Suitable for wall mounting with round cut-out approx. 150 mmSafety: Inbuilt thermal overload protectionProtection: IPX4 Warranty: Minimum 2 years including required, testing and commissioning complete in all respects all as specified and direceted by Engr-in-charge. |
| 162 | Material and labour for supply and fix rigid non-metallic PVC conduit 25 MM bore exclusive of boxes (junction/terminal) but inclusiveof all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts complete all as specified and directed. |
| 163 | Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS CRC 18 gauge square rforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening of size 70'' x 78'' as complete all as specified and as directed. |
| 164 | Supply, install, 2 way LED wall surface mounted light fitting 15W warm white colour complete all as specified and directed. |
| 165 | Supply and fix LED Flaxi strip Neon AC LED warm white Colour Strip Light with PVC outer cover ,IP 65 input voltage 220-240 VAC input frequency 50 Hzs power factor ss protection -IP -65 working temp range -20 degree celcius to + 45 degree celcius working humidity range 10-90 RH and complete all as specified & directed by Engr-in-Charge. |
| 166 | Bell push, flush type 6 Amps 240 volts complete all as specified and as directed. |
| 167 | Bell (ding dong type), AC electronic type, 230 volts, single pole, 50 Hz complete all as specified and as directed. |
| 168 | Material and labour for engagement light 5 watt LED based with decorative globe comple with holder and to connect ceiling rose complete all is specified and directed. |
| 169 | Note:-The subject work shall be caried out in time bound manner being urgent work. The contractor shall make his own arrangement to complete the work within the completion date as ginven by GE in WO No 1 in extention shall be granted under the subject work. The contractor are advised to visit the site of work and quote their rate accordingly. No claim whatsoever on the this account shall be entertained at later stage. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy