| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level. |
| 4 | 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | 1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 6 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size). |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level |
| 8 | 1:1½:3 (1 cement : 1½ coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in walls (any thickness). Including attached pillasters, buttresses, plinth and string courses fillets columns, pillers, piers, abutments, posts and struts etc. upto floor 5 level exclusing cost of centring shuttering, finishing and reinforcement. |
| 10 | 1:1.5:3 (I cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form for |
| 12 | Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Edges of slabs and breaks in floors and walls. |
| 15 | Under 20 cm wide |
| 16 | Columns, pillars, piers, Abutments, posts and struts |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (at all levels) in all shapes and sizes in: |
| 19 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 20 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 (at all levels) |
| 21 | Cement mortar 1: 4 (1 cement: 4 coarse sand) |
| 22 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 23 | Cold twisted/TMT bars |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Hot finished welded type tubes |
| 26 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 27 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
| 28 | 4.0mm thick glass panes |
| 29 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. |
| 30 | Galvanized M.S wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 31 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. |
| 32 | 40mm thick with 20 mm nominal size stone aggregate. |
| 33 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 34 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 35 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. |
| 36 | Ridges plain (500-600 mm) |
| 37 | 12 mm cement plaster of mix : |
| 38 | 1:6 (1 cement: 6 coarse sand) |
| 39 | 15mm Cement plaster on the rough side of single or half brick wall of mix: |
| 40 | 1:6 (1 cement: 6 coarse sand) |
| 41 | 6 mm cement plaster of mix:- |
| 42 | 1 : 3 (1 cement : 3 fine sand) |
| 43 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable priming coat with cement primer. |
| 44 | Finishing walls with Acrylic exterior paint of required shade: |
| 45 | New work (Two or more coats applied over and includign priming coat of exterior primer applied @2.20 kg/10 sqm) |
| 46 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 47 | Two or more coats on new work |
| 48 | Providing & laying River Bed Material (RBM) including loading, carrying, unloading, spreading, compacting and watering complete item. |
| 49 | Providing and fixing welded wire Mesh fabric fencing of required width in mesh size 25x25 mm made of M.S. wire of dia 2 mm including strengthening with nuts, bolts and washers as required over and including priming coat complete as per the direction of Engineer-incharge. |
| 50 | Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B) |
| 51 | Single Pole |
| 52 | Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required |
| 53 | 40 amps SPN |
| 54 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection. |
| 55 | Providing and fixing 25 mm x 5mm GI strip from earth electrode as required |
| 56 | Supply and fixing of Aluminium flexible cable 2 C x 16 sqmm including connection testing etc as reqd. |
| 57 | Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required. |
| 58 | 12 way SPN |
| 59 | Supply and fixing 1x20 watt fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. |
| 60 | Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) |
| 61 | Supply and fixing of 45 watt LED street light with G.I. pipe bracket with all accessories including connection testing etc as reqd. |
| 62 | Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with modular switch, modulr plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 63 | Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp modular switch socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire. |
| 64 | Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 1.5 mm copper wire for loop earthing required |
| 65 | Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x5.0 Sq mm copper wire for loop earthing as required |
| 66 | Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring ) |
| 67 | Supplying and fixing of suitable G.I. box with modular plate and cover in the front on surface or in recessed, including providing & fixing 6 pin 15/16 Amp and 5/6 Ampere modular socket outlet and 15/16 Ampere modular swtich including connection testing etc as reqd. |
| 68 | Supplying and fixing of exhaust fan 300 mm sweep heavy duty trans air with double ball bearing including connection, testing etc. as required. |
| 69 | Supply and fixing of 1200 mm sweep ceiling fan with double ball bearing inlcuding connection testing etc as reqd. |
| 70 | Supply and fixing of batton holder with 9 watt LED bulb including connection, testing etc. as reqd. Please Enable Macros to View BoQ information |