| 1 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Grandlay, Skytone, Gloster, KEI Havell's, Diatron make) |
| 2 | 1) 95 Sq.mm. 3.5 Core (PS No. 501) |
| 3 | 2) 25 Sq.mm. 3.5Core (PS No. 501) |
| 4 | 3) 16 Sq.mm. 4 Core (PS No. 501) |
| 5 | 4) 16 Sq.mm. 2 Core (PS No. 501) |
| 6 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of E/I. P.S No. 504. |
| 7 | a) 95 Sq.mm. |
| 8 | b) 25 Sq.mm. |
| 9 | c) 16 Sq.mm. |
| 10 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725A) |
| 11 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects.( Trenchless if required) Rex/Duraline/Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 12 | S/Laying of 63 mm dia (OD 63 mm & ID 51 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench or Trenchless method if required but excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.1 page no. 49 |
| 13 | Underground/overground laying of HDPE pipe OFC/Power/Data/coaxil cable complete with all accessories as required |
| 14 | Supply and fixing of 100 Amp 4 pole MCCB ( 25KA) thermal magnetic release PS No. 1021© Cat-A |
| 15 | Supply of Labour i.e. Electrician/Lineman 8 hrs per day for 1 months |
| 16 | Supply of Labour i.e. Helper 8 hrs per day for 1 months |
| 17 | Supply and erection of overhead line with ACSR Conductor (Dog & Raccoon) poles / service bracket including binding etc. complete in all respects. P.S. No. 627 |
| 18 | Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46) |
| 19 | Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 pg.45) |
| 20 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC cost data book 2019/P-48) |
| 21 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I. |
| 22 | Repair of 63 KVA Transformer incl. changing of HV & LV Coil, Bushing, Gasket & fresh transformer oil without returning of old & unsearciable material. Complete in all respects as per direction of E/I.(AOR) |
| 23 | Dis./Re-errection of 25/63/100/250 KVA Al. wound outdoor type Transformer as per ISS including fees as per direction of E/I.(AOR) |
| 24 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories ncludingferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (240 sq. mm) as per DSR 18/item no. 10.6.3 pg no. 38 |
| 25 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 26 | Location and pin pointing of 11 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 27 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by making experts technical staff. Complete in all respects as per direction of Engineer in charge (AOR) |
| 28 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in graiting, frames guard bar, ladder , railings, brackets, gates and similar work (AOR) |
| 29 | Supply of sheet module odd compound and thermoplastic LT Distribution box of size 400x350x200mm for 3 polthnase out door connection to LT line consumers through overhead ABC line, Shock inporoof, rust proof, termite proof, vermin proof, self extinguished. Complete with provision of 33% phase aluminium bus bars of EC grade of size 26x6x300 mm long and netural bus bar coolf size 40x6x300 mm. it will be with coloured sleefes on each busbar, the same will be writti facility of cable termination having 1 incoming and 4 outgoing with 4 polymeric grade of 20.65mm dia and 6 no. rubber gurmuts on each (AOR) |
| 30 | Repairing of 11KV fuse wire /Jumper i.c. supply & fixing of required size conductor, fuse wire of 11KV line /DP Structure of transformer by taking shutdown from UPPCL department with all safety instruments, Life safety belt, gloves, shoes & other ncecessary items. complete including all taxes. Please Enable Macros to View BoQ information |