| 1 | Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil. |
| 2 | Excavation in post holes each n.exc 0.50 cum getting out. Returning filling in layers n.exc 25cm etc watering removing surplus soil to a distance n.exc 50 mt and making good surface in hard/ dense soil |
| 3 | M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) laid in base, mass concrete including necessary form work complete all as specified and directed by Engineer- In -charge. |
| 4 | M&L hard core of broken stone of gauge 63mm but n.exc 150 mm deposited 15cm thickness spread and leveled in layers ,water and rammed true surface in plinth protection/ hard standing complete all as directed by Engineer-in-charge. |
| 5 | M&L for 100 mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) laid in floor, sub base including necessary form work complete all as specified and directed |
| 6 | M&L for 100 mm thick PCC 1:2:4 type B-1, as in paving (20 mm graded stone aggregate) finished even and smooth with out using extra cement etc including necessary foam work complete all as specified and directed. |
| 7 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, hollow,channel or flat sections) including distance pieces, cleats etc. FE 410-W(Gde -E-250) quality A. Complete all as specified and directed by Engr-in-charge. |
| 8 | S&F Steel work as in tubular trusses/columns including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified and directed by Engr-in-Charge. |
| 9 | S&F Pre- painted galvalume aluminum zinc coating GI based trapazoidal steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 10 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 11 | M&L for two coats of synthetic enamil paint over a coat of red oxide zinc chrome on new steel surfaces of any description complete all as specified. |
| 12 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 13 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed. |
| 14 | Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor cable, 1100 V grade of size 1.5 sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earthing and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - |
| 15 | One light /fan/ Bell Point controlled by one switch |
| 16 | One 3 pin socket outlet, 5 Amp independent |
| 17 | Supply and fix switch socket combination multi purpose, 5 Amp complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F wall mounted LED light fitting 1x20 watts AC decorative box type with driver holder including LED tube light , energy efficient type 4 feet long with neccessary conection prewired and making connection with 3 core copper flexible cable of appropriate size from ceilling rose. |
| 19 | Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified |
| 20 | S & F Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked complete all as specified. |
| 21 | Supply and fix sheet metal enclosure SPN DB 02 way,single phase 240 volts double door with 200 Amp rated bus bar complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fix sheet metal enclosure SPN DB 8 way,single phase 240 volts double door with 200 Amp rated bus bar complete all as specified and directed by Engr-in-Charge.. |
| 23 | Supply and fix main Circuit breaker (MCB) single pole, 6 to 32 Amp 240 volt C curve 10 KA, IP 20 complete all as specified and directed. |
| 24 | M&L for main Circuit breaker (MCB) single pole & neutral 240 volt C curve 10 KA 32 Amps capacity IP 20 complete all as specified and directed. |
| 25 | S&F LED security light fitting 35 watts 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 26 | S&F two single core 2.5 sqmm cable for sub Main wiring with copper conductor multistranded PVC insulated and unsheathed 1100 Volts grade in and including PVC casing capping with fixing accessories including one run of 2.5 Sq mm copper conductor. (Note - Two runs of 2.5 Sq mm cable, one run of 2.5 Sq mm earth cable and one run of PVC casing Capping shall be measured as one running meter.) |
| 27 | Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified. |
| 28 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench) |
| 29 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 30 | Supplying and laying double walled corrugated HDPE Pipes of size 40 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of LT/HT cables complete all as specified and directed |
| 31 | Supply laying and testing XLPE cable insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core. |
| 32 | Material and labour for earthing complete with galvanized steel earth plate 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.5 mtr filled around with 15 cm thick alternate layers of charcoal dust and salt and connected to earth lead wire 4mm dia (8 SWG) by means of bolt, nut and check nuts and washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, pcc 1:3:6 type C-1 in chambers RCC 1:2:4 type B-1 in pit cover reinforced with 8 mm dia deformed bars 15cm center to center both ways all as directed by Engr-In-Charge, complete all as shown in electric plate No 3 of MES SSR Part I Please Enable Macros to View BoQ information |