| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil 0.00 LVL. TO 1.50 MTR. (Including all taxes, T&P and labour cess but excluding GST) |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Including all taxes, T&P and labour cess but excluding GST) |
| 3 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) (Including all taxes, T&P and labour cess but excluding GST) |
| 4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. (Including all taxes, T&P and labour cess but excluding GST) |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shallbe as follows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters /100 sqm (5)Treatment of soil along external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apron along external perimter 5 liters/100 sqm. (Including all taxes, T&P and labour cess but excluding GST) |
| 6 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level (Including all taxes, T&P and labour cess but excluding GST) |
| 7 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :450 mm dia piles (Including all taxes, T&P and labour cess but excluding GST) |
| 8 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Initial Test (Including all taxes, T&P and labour cess but excluding GST) |
| 9 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Routine Test (Including all taxes, T&P and labour cess but excluding GST) |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank (Including all taxes, T&P and labour cess but excluding GST) |
| 11 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured. (Including all taxes, T&P and labour cess but excluding GST) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete (Including all taxes, T&P and labour cess but excluding GST) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts (Including all taxes, T&P and labour cess but excluding GST) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Beam, Plinth Beam, Girders, Bressumers and Cantilivers (Including all taxes, T&P and labour cess but excluding GST) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of from for Suspended floors roofs landings balconies and access platforms (Including all taxes, T&P and labour cess but excluding GST) |
| 16 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) For 370 kg/Cum All works above plinth level (Steel floor to Fourth Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 17 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level (For R.C.C. Lintel) For 370 kg/Cum All works above plinth level Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. (Fifth to Eight Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 18 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level (For R.C.C. Lintel) For 370 kg/Cum All works above plinth level Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. (Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 19 | First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work. (Including all taxes, T&P and labour cess but excluding GST) |
| 20 | Brick work in super-structure above plinth level up to fourth including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. 1:6 (1 cement : 6 coarse sand) (Stilt to Fourth Floor) using M-150 brick (Including all taxes, T&P and labour cess but excluding GST) |
| 21 | Brick work in super-structure including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. 1:6 (1 cement : 6 coarse sand) (Fifth to Eighth Floor) using M150 brick (Including all taxes, T&P and labour cess but excluding GST) |
| 22 | Brick work in super-structure including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. 1:6 (1 cement : 6 coarse sand) (Ninth to Terace Floor) using M-150 bricks (Including all taxes, T&P and labour cess but excluding GST) |
| 23 | Brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. Upto 4th floor using M-150 bricks (Including all taxes, T&P and labour cess but excluding GST) |
| 24 | Brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 4th to 8th floor using M-150 bricks (Including all taxes, T&P and labour cess but excluding GST) |
| 25 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 coarse sand (All Floors) (Including all taxes, T&P and labour cess but excluding GST) |
| 26 | 15 mm thick plaster in 1:6 cement & course sand on outer wall . Ground floor to third floor (Including all taxes, T&P and labour cess but excluding GST) |
| 27 | 15 mm thick plaster in 1:6 cement & course sand on outer wall 4th floor (Including all taxes, T&P and labour cess but excluding GST) Fourth floor |
| 28 | 15 mm thick plaster in 1:6 cement & course sand on outer wall 5th floor (Including all taxes, T&P and labour cess but excluding GST) Fifth floor |
| 29 | 15 mm thick plaster in 1:6 cement & course sand on outer wall 6th floor (Including all taxes, T&P and labour cess but excluding GST) Sixth floor |
| 30 | 15 mm thick plaster in 1:6 cement & course sand on outer wall 7th floor (Including all taxes, T&P and labour cess but excluding GST) 7th floor |
| 31 | 15 mm thick plaster in 1:6 cement & course sand on outer wall 8th floor (Including all taxes, T&P and labour cess but excluding GST) 8th floor |
| 32 | 15 mm thick plaster in 1:6 cement & course sand on outer wall terrace floor (Including all taxes, T&P and labour cess but excluding GST) Terrace floor |
| 33 | 12mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 4 coarse sand. (All Floors) (Including all taxes, T&P and labour cess but excluding GST) |
| 34 | Making grooves/deep course 10 to12mm wide x 8mm deep in plaster of the wall or in ceiling vertically or horizontally as required.. (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 35 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm. (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 36 | Providing and laying vitrified floor tiles (Kazaria or Equivalent) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 37 | Providing and laying Vitrified tiles (Kazaria or Equivalent) in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :20 mm thick (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 39 | Providing and laying Ceramic glazed floor tiles (Kazaria, Somany, Cera or Equivalent) of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.. (First floor to Terace Floor) (Including all taxes, T&P and labour cess but excluding GST) |
| 41 | 20 mm cement plaster in two coats, backing coat 17mm and finished coat 3 mm thick (of neat cement and marble dust in ratio 5:1) on rough side of single or half brick interior plastering upto two floor level including internal round angles. (1 cement :3 coarse sand) (Including all taxes, T&P and labour cess but excluding GST) |
| 42 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). (Including all taxes, T&P and labour cess but excluding GST) |
| 43 | Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick (Single leaf and Double Leaf) (Including all taxes, T&P and labour cess but excluding GST) |
| 44 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. (Including all taxes, T&P and labour cess but excluding GST) |
| 45 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame. (Including all taxes, T&P and labour cess but excluding GST) |
| 46 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces(Including all taxes, T&P and labour cess but excluding GST) |
| 47 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge (Including all taxes, T&P and labour cess but excluding GST) |
| 48 | Fabrication of M.S. Z-section window and ventilators (Including all taxes, T&P and labour cess but excluding GST) |
| 49 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (Including all taxes, T&P and labour cess but excluding GST) |
| 50 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding (Including all taxes, T&P and labour cess but excluding GST) |
| 51 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (Including all taxes, T&P and labour cess but excluding GST) |
| 52 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (Including all taxes, T&P and labour cess but excluding GST) |
| 53 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compund) content less than 50 grams/ litre of approved brand & manufacture, including applying addotional coats whereever required to achieve even shade & colour. Two coats, with water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre. (Including all taxes, T&P and labour cess but excluding GST) |
| 54 | Painting Steel & Wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture(Including all taxes, T&P and labour cess but excluding GST) |
| 55 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Including all taxes, T&P and labour cess but excluding GST) |
| 56 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Including all taxes, T&P and labour cess but excluding GST) |
| 57 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . (Including all taxes, T&P and labour cess but excluding GST) |
| 58 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete 250 mm x 10mm (Including all taxes, T&P and labour cess but excluding GST) |
| 59 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm (Including all taxes, T&P and labour cess but excluding GST) |
| 60 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (Including all taxes, T&P and labour cess but excluding GST) |
| 61 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (Including all taxes, T&P and labour cess but excluding GST) |
| 62 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. (Including all taxes, T&P and labour cess but excluding GST) |
| 63 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (Including all taxes, T&P and labour cess but excluding GST) |
| 64 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (Including all taxes, T&P and labour cess but excluding GST) |
| 65 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK(Including all taxes, T&P and labour cess but excluding GST) |
| 66 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(Including all taxes, T&P and labour cess but excluding GST) |
| 67 | Providing, assembling and supplying visionglass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided (Including all taxes, T&P and labour cess but excluding GST) |
| 68 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.(Including all taxes, T&P and labour cess but excluding GST) |
| 69 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to twelve story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after . The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. (Including all taxes, T&P and labour cess but excluding GST) |
| 70 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests (Including all taxes, T&P and labour cess but excluding GST) |
| 71 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (Including all taxes, T&P and labour cess but excluding GST) |
| 72 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (Including all taxes, T&P and labour cess but excluding GST) |
| 73 | P&F of White vetrious chaina flat back half stall Urinal of size 580x380x350mm (Including all taxes, T&P and labour cess but excluding GST) |
| 74 | P&F stone slab table rubbed edge rounded and polished of size 75x50cm deep and 1.8cm thick (Including all taxes, T&P and labour cess but excluding GST) |
| 75 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 76 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Including all taxes, T&P and labour cess but excluding GST) |
| 77 | Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required. Kitchen sink with drain board Size 510x1040 mm bowl depth 200mm (Including all taxes, T&P and labour cess but excluding GST) |
| 78 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. (Including all taxes, T&P and labour cess but excluding GST) |
| 79 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 80 | Providing and fixing CP Brass Single lever telephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. 15mm nominal dia (Including all taxes, T&P and labour cess but excluding GST) |
| 81 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15 mm nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 82 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 83 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (Including all taxes, T&P and labour cess but excluding GST) |
| 84 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 85 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 20mm nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 86 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (Including all taxes, T&P and labour cess but excluding GST) |
| 87 | Providing and fixing Toilet paper holder (Including all taxes, T&P and labour cess but excluding GST) |
| 88 | Providing and fixing 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (Including all taxes, T&P and labour cess but excluding GST) |
| 89 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm (Including all taxes, T&P and labour cess but excluding GST) |
| 90 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm (Including all taxes, T&P and labour cess but excluding GST) |
| 91 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend (Including all taxes, T&P and labour cess but excluding GST) |
| 92 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend110 mm Shoe (Including all taxes, T&P and labour cess but excluding GST) |
| 93 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (Including all taxes, T&P and labour cess but excluding GST) |
| 94 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. (Including all taxes, T&P and labour cess but excluding GST) |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 96 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15mm dia nominal outer dia pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 97 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..20mm dia nominal bore. Internal work expose on wall(Including all taxes, T&P and labour cess but excluding GST) |
| 98 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25mm dia nominal bore Internal work expose on wall (Including all taxes, T&P and labour cess but excluding GST) |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32mm dia nominal bore Internal work expose on wall(Including all taxes, T&P and labour cess but excluding GST) |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.40mm dia nominal bore Internal work expose on wall(Including all taxes, T&P and labour cess but excluding GST) |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.50mm dia nominal bore Internal work expose on wall(Including all taxes, T&P and labour cess but excluding GST) |
| 102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.65mm dia nominal bore Internal work expose on wall(Including all taxes, T&P and labour cess but excluding GST) |
| 103 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. 50mm nominal bore. (Including all taxes, T&P and labour cess but excluding GST) |
| 104 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. 80mm nominal bore. (Including all taxes, T&P and labour cess but excluding GST) |
| 105 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. (Including all taxes, T&P and labour cess but excluding GST)50 mm diameter pipe |
| 106 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. (Including all taxes, T&P and labour cess but excluding GST)80 mm diameter pipe |
| 107 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST |
| 108 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work.50mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 109 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work..80mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 110 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work)..32mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 111 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work)..40mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 112 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).50mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 113 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work)..80mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 114 | Providing and fixing gun metal gate valve with wheel of approved quality...32mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 115 | Providing and fixing gun metal gate valve with wheel of approved quality...40mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 116 | Providing and fixing gun metal gate valve with wheel of approved quality..50mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 117 | Providing and fixing gun metal gate valve with wheel of approved quality…80mm dia nominal bore (Including all taxes, T&P and labour cess but excluding GST) |
| 118 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. (Including all taxes, T&P and labour cess but excluding GST) |
| 119 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 120 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm. dia. RCC Pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 121 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. RCC Pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 122 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm. dia. RCC Pipes (Including all taxes, T&P and labour cess but excluding GST) |
| 123 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. (Including all taxes, T&P and labour cess but excluding GST) |
| 124 | Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. 50 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 125 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 (Including all taxes, T&P and labour cess but excluding GST) |
| 126 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line (Including all taxes, T&P and labour cess but excluding GST) |
| 127 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line Extra for depth for manholes: Size 90x80cm with FPS bricks(class I) (Including all taxes, T&P and labour cess but excluding GST) |
| 128 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar (Including all taxes, T&P and labour cess but excluding GST) |
| 129 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.a) 110mm dia P.V.C. pipe (Including all taxes, T&P and labour cess but excluding GST) |
| 130 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.b) 75mm dia P.V.C. pipe (Including all taxes, T&P and labour cess but excluding GST) |
| 131 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. 110mm (Including all taxes, T&P and labour cess but excluding GST) |
| 132 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. (Including all taxes, T&P and labour cess but excluding GST) |
| 133 | Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line (Including all taxes, T&P and labour cess but excluding GST) |
| 134 | Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 (Including all taxes, T&P and labour cess but excluding GST) |
| 135 | Providing & fixing G.I. pipes complete with G.I. fittings for internal work but expose on wall including tenching and refilling etc. (external work) 80 mm nominal bore. (Including all taxes, T&P and labour cess but excluding GST) |
| 136 | Providing & fixing G.I. pipes complete with G.I. fittings for internal work but expose on wall including tenching and refilling etc. (external work) 50 mm nominal bore. (Including all taxes, T&P and labour cess but excluding GST) |
| 137 | Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design (Including all taxes, T&P and labour cess but excluding GST) |
| 138 | Construction of Tubewell suitable for 1000 lpm yield (Having 15 HP KSB/equivalent make submercible pumpset model bpd 302/4+UAMI 150/6/22-203 S/D) and Discharge of water LPM 860 approx. including all as per TS estimate (Including all taxes, T&P and labour cess but excluding GST) |
| 139 | Construction of Under Ground Tank complete in all respect as per attached design, drawing and specifaction of E/I of the work. (Including all taxes, T&P and labour cess but excluding GST) |
| 140 | Providing laving and construction of rainwater harvesting system complete in all respect as per attached design, drawing and satisfaction of E/I of the work. (Including all taxes, T&P and labour cess but excluding GST) |
| 141 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 As per DSR No. 16.78.1direction of E/I.(Including all taxes, Labour cess but exluding GST) |
| 142 | Providing and fixing chromium plated brass curtain rod having wall thicknes of 1.25mm with two chromum plated brass brackets fixed with CP brass screws and PVC sleeves etc. wherever necessary complete 25mm dia (Including all taxes, Labour cess but exluding GST) |
| 143 | Providing gola (along parapet) 75x75mm in cement concrete 1:2:4 finishing with cement mortar 1:3 in 75x75mm deep chase (Including all taxes, Labour cess but exluding GST) |
| 144 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 100mm dia (Including all taxes, Labour cess but exluding GST) |
| 145 | Providing and fixing C.P. brass 32mm size bottal trap of approved quality and make and as per dirction of E/I (Including all taxes, Labour cess but exluding GST) |
| 146 | Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete As per DSR No. 16.91.2 and direction of E/I.(Including all taxes, Labour cess but exluding GST) |
| 147 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Including all taxes, Labour cess but exluding GST) |
| 148 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. (Including all taxes, Labour cess but exluding GST) |
| 149 | Point wiring-- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 150 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 151 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 152 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 153 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 154 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 module ( 75x75 mm) (Including all taxes, T&P and labour cess but excluding GST) |
| 155 | Supply and fixing 3 pin 5A celling rose on the existing Junction box including connection as required (Including all taxes, T&P and labour cess but excluding GST) |
| 156 | Supply and fixing Batten / angle holder including connection as required (Including all taxes, T&P and labour cess but excluding GST) |
| 157 | Supply and fixing Call bell / buzzer suitable for single phae 230V including connection as required (Including all taxes, T&P and labour cess but excluding GST) |
| 158 | Providing fixing of circular / Hexgonal cast iron or MS sheet bos for celling fan clamp of internal 140mm ,73mm height , top lid of 1.5mm thick MS sheet with its top surface for proper bonding top lid shall be screwed into cast iron / MS box by means od 3.3mm dia round headed srews one lock at corner clamp shall be made of 12mm dia MS bar bent to shape as per standard drawing (Including all taxes, T&P and labour cess but excluding GST) |
| 159 | Supply and fixing of following sizes medium class PVC conduit pipe along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required size 25mm (Including all taxes, T&P and labour cess but excluding GST) |
| 160 | Supplying and drawing of 0.5 mm dia FRLSH PVC insulated anneleaed copper conductor unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required 2 pair cable (Including all taxes, T&P and labour cess but excluding GST) |
| 161 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 162 | Supplying and fixing following socket on the existing switch box / cover plate including connection ec as required for Telephone socket out let (Including all taxes, T&P and labour cess but excluding GST) |
| 163 | Supplying and fixing following socket on the existing switch box / cover plate including connection ec as required for TV antena socet outlet (Including all taxes, T&P and labour cess but excluding GST) |
| 164 | Supplying and fixing following socket on the existing switch box / cover plate including connection ec as required for Bell push (Including all taxes, T&P and labour cess but excluding GST) |
| 165 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 166 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 167 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 168 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 169 | 2 X 6sq. mm + 1 X 6sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 170 | 2x10sq. mm + 1 X 6sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 171 | 4X16sq. mm + 2 X 6sq. mm earth wire (Including all taxes, T&P and labour cess but excluding GST) |
| 172 | Panel , Distribution board,--Supply and fixing of 4way VTPN with additional metalic door suitable for For MCCB incomer (Including all taxes, T&P and labour cess but excluding GST) |
| 173 | S/f of following ways ,horizontal type single pole and neutrl sheet (SPN DB) distribution board 240 V on surface surface/recess mounting complete with tinned copper bus bar, common neutral bus bar , earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 8way double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 174 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required .For 8 way, Double door SPN MCBDB (Including all taxes, T&P and labour cess but excluding GST) |
| 175 | Supply and fixing of cable end box (Loose wire box) suitable for following tripple pole and neutral sheet steel MCB DB (TPNDB) 415 V on srfac e/ recess comlete in all respect -For V TPN DB (Including all taxes, T&P and labour cess but excluding GST) |
| 176 | S&F of 100 Amp 4 pole MCCB(25 KA) Thermal Magnetic release (C) cat A (Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 177 | S&F of 63 Amp 4 pole MCCB(25 KA) Thermal Magnetic release (C) cat A (Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 178 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 179 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 180 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 181 | Supplying, installation on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. Rating 200Amp (25KA) (Including all taxes, T&P and labour cess but excluding GST) |
| 182 | Same as above Rising Mains but for 315 Amp(25 KA) (Including all taxes, T&P and labour cess but excluding GST) |
| 183 | Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required Rating 200Amp (25KA) (Including all taxes, T&P and labour cess but excluding GST) |
| 184 | Same as above end feed unit but for 315 Amp(25 KA) (Including all taxes, T&P and labour cess but excluding GST) |
| 185 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. Rating -- 200 A,36KA,FPMCCB (Including all taxes, T&P and labour cess but excluding GST) |
| 186 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.Rating -- 315/320 A,36KA,FPMCCB (Including all taxes, T&P and labour cess but excluding GST) |
| 187 | Supplying, installation, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. Rating 100 Amp (Including all taxes, T&P and labour cess but excluding GST) |
| 188 | Same as above tap off box but 63 Amp (Including all taxes, T&P and labour cess but excluding GST) |
| 189 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incomming - 100Amp 4 pole MCCB , Outgoing 2nos 63Amp MCCB 4 pole (Including all taxes, T&P and labour cess but excluding GST) |
| 190 | Light and fan fixtures-Supply of Fresh air fan 300 mm (Including all taxes, T&P and labour cess but excluding GST) |
| 191 | Supply and fixing of Solar Aviation Light (Including all taxes, T&P and labour cess but excluding GST) |
| 192 | Supply and fixing of mirror light 11 Watt (Including all taxes, T&P and labour cess but excluding GST) |
| 193 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Rating- 40W (Including all taxes, T&P and labour cess but excluding GST) |
| 194 | LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . Rating 22W (Including all taxes, T&P and labour cess but excluding GST) |
| 195 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Rating 120W (Including all taxes, T&P and labour cess but excluding GST) |
| 196 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (Including all taxes, T&P and labour cess but excluding GST) |
| 197 | Supply and fixing ofLED bulb 9W (Make - Havells/Philips/ Bajaj) (Including all taxes, T&P and labour cess but excluding GST) |
| 198 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450mm (Including all taxes, T&P and labour cess but excluding GST) |
| 199 | Extra for fixing of Louvers/ shutters completed with frame for ex fan (Including all taxes, T&P and labour cess but excluding GST) |
| 200 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 201 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 202 | S/F 2 No. 6 SWG GI wire (Including all taxes, T&P and labour cess but excluding GST) |
| 203 | Providing /Fixing of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all taxes, T&P and labour cess but excluding GST) |
| 204 | Providing and fixing 25 mm X 5 mm copper strip on urface or in recess for connections etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 205 | Lighting Arrester for Building -Proving and fixing of Lightining conductor finial made of 25mm dia 300mm long , GI tube , having single prong at top with 85 mm dia 6 mm thick GI base plate including holes etc complete as required (Including all taxes, T&P and labour cess but excluding GST) |
| 206 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) byriveting / nut bolting/ sweating and soldering etc as required (Including all taxes, T&P and labour cess but excluding GST) |
| 207 | Providing Fixing GI tape 20x3mm thick on parapet or surface of wall for Lightining conductor complete as required (for Horizental run ) (Including all taxes, T&P and labour cess but excluding GST) |
| 208 | Providing Fixing GI tape 20x3mm thick on parapet or surface of wall for Lightining conductor complete as required (for Vertical run ) (Including all taxes, T&P and labour cess but excluding GST) |
| 209 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 210 | Supply and burring of GI earth plate 600mm x 600mm x 6mm thick including accessoriesand providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr long etc with required material etc (Including all taxes, T&P and labour cess but excluding GST) |
| 211 | Cables-Providing Laying of GI pipe in ground complete with GI fitting including trenchining (75 mm depth ) refilling etc as required 100mm (Including all taxes, T&P and labour cess but excluding GST) |
| 212 | Providing Laying of GI pipe in ground complete with GI fitting including trenchining (75 mm depth ) refilling etc as required 150mm (Including all taxes, T&P and labour cess but excluding GST) |
| 213 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.400 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 214 | Same as above but for Size-240sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 215 | Same as above but for Size-.50 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 216 | Same as above Size-.25 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 217 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 400 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 218 | Same as above but for Size- 240 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 219 | Same as above but for Size- 50 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 220 | Same as above but for Size- 25 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 221 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-400 Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 222 | Same as above but for Size-240 Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 223 | Same as above but for Size-50Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 224 | Same as above but for Size-25Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 225 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal) (Including all taxes, T&P and labour cess but excluding GST) |
| 226 | Same as above but size 160 mm dia (OD-160 mm & ID-135 mm nominal) (Including all taxes, T&P and labour cess but excluding GST) |
| 227 | Supply & Errecetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only . Incoming ----800Amp 4 pole MCCB -1 nos C/O 320Amp - 1nos Out going--315 Amp MCCB 4 pole-2nos , 200Amp MCCB 4 pole-3nos, 125 Amp -1 nos 100 Amp-2 nos, 63 Amp--2 nos , (Including all taxes, T&P and labour cess but excluding GST) |
| 228 | Same As above but MCCB panel I/C 400 Amp - 1 nos , O/G 315Amp-1nos,100 Amp-1nos,63Amp-1nos (Including all taxes, T&P and labour cess but excluding GST) |
| 229 | Supply and fixing of 8 mtr GI octagonal pole of approved make (top dia 70mm , bottom dia 135mm and Base plate16mm thick )having 3mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC foundation bolt including the cost of foundation , excavation & back filling and required T&P complete in all respect (Including all taxes, T&P and labour cess but excluding GST) |
| 230 | S/f of following ways ,horizontal type single pole and neutrl sheet (SPN DB) distribution board 240 V on surface surface/recess mounting complete with tinned copper bus bar, common neutral bus bar , earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 8way double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 231 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, T&P and labour cess but excluding GST) |
| 232 | Supply and fixing of 63Amp TPN 415 Vswitch disconnector fues (Including all taxes, T&P and labour cess but excluding GST) |
| 233 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 2 output per phase and suitable for single phase supply (Including all taxes, T&P and labour cess but excluding GST) |
| 234 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Rating 150W (Including all taxes, T&P and labour cess but excluding GST) |
| 235 | Supply and fixing of Decorative bollard light 40 to 45watt LED post top indirect light luminarieshaving presure die cast aluminium body and UV stablized PC clear/ frosted glass cover, with driver set confirming to IPP 66 and 1k 08 protection , potted driver complet ein all respect sy 4800-5400 system lumenstem lumen ,>120 lm/ W P.F>0.95. THD<10% at full load, CRI>70, potted driver set in metal housing ( not circuilatory ) pha eto phase protection at 440V &, >300 V auto cut and restart feature with 5 year warranty (Including all taxes, T&P and labour cess but excluding GST) |
| 236 | Supplying and drawings of FRLS PVC insulated copper conductor, single core multistrand cable in the existing surface/recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm for street light (Including all taxes, T&P and labour cess but excluding GST) |
| 237 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal) (Including all taxes, T&P and labour cess but excluding GST) |
| 238 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.240 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 239 | Same as above but for Size-.150 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 240 | Same as above Size-.25 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 241 | Same as above Size-.10 sq. mm 4 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, T&P and labour cess but excluding GST) |
| 242 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 240sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 243 | Same as above but for Size- 150 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 244 | Same as above but for Size- 25 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, T&P and labour cess but excluding GST) |
| 245 | Same as above but for Size- 10 sq. mm 4 core (Make - Havells/ Anchor/Dowells)(Including all taxes, T&P and labour cess but excluding GST) |
| 246 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-240 Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 247 | Same as above but for Size-150Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 248 | Same as above but for Size-25Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 249 | Same as above but for Size-10Sqmm (Make - Dowells or equivalent) (Including all taxes, T&P and labour cess but excluding GST) |
| 250 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Including all taxes, T&P and labou |
| 251 | S/F 2 No. 6 SWG GI wire (Including all taxes, T&P and labour cess but excluding GST) |
| 252 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all taxes, T&P and labour cess but excluding GST) |
| 253 | Internal Fire fighting System --(A)-fire alarm Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 254 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 255 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 256 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 257 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 258 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 259 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DCsupply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt 30 AH each sealed maintenance free batteries -1 set. (Including all taxes, T&P and labour cess but excluding GST) |
| 260 | Supply and fixing of following size of steel conduit along with accessories in surface / recess including painting in case of surfase conduit or cutting the wall and making good the same in case of recess conduit size 20mm (Including all taxes, T&P and labour cess but excluding GST) |
| 261 | Supply and fixing of following size of steel conduit along with accessories in surface / recess including painting in case of surfase conduit or cutting the wall and making good the same in case of recess conduit size 25mm (Including all taxes, T&P and labour cess but excluding GST) |
| 262 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sqmm (Including all taxes, T&P and labour cess but excluding GST) |
| 263 | Supplying and drawing following sizes of FRLSH PVC insulated copper conductor , single core cable in the existing surface / recessed stell /PVC conduit size- 3x1.5sqmm (Including all taxes, T&P and labour cess but excluding GST) |
| 264 | (B) Fire fighting-- Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 150mm dia (wall thickness 6.3 mm) (Including all taxes, T&P and labour cess but excluding GST) |
| 265 | Same as above but for size100 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 266 | Same as above but for size 80 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 267 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 268 | Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Stainless steel (Including all taxes, T&P and labour cess but excluding GST) |
| 269 | Supplying and fixing first aid Hose Reel with MS construction spray painted n post officered,conforming to IS-884complete with the following as required.20mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520mm nominal internal dia gunmetal globe valve&nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25mm dia stop gun metal valve & M.S. Pipe and socket 30 M long (Including all taxes, T&P and labour cess but excluding GST) |
| 270 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Gun Metal (Including all taxes, T&P and labour cess but excluding GST) |
| 271 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required- Gu metal (Including all taxes, T&P and labour cess but excluding GST) |
| 272 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 273 | same as above but for size 100 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 274 | same as above but for size 150 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 275 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required size 100mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 276 | same as above but for size 150mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 277 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (Including all taxes, T&P and labour cess but excluding GST) |
| 278 | A) Supplying, installation, testing and commissioning of electric driven terrace pump 450LPM 35 mtr Head ,10HPsuitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. E) Suitable cement concrete foundation duly plastered and with anti vibration pads. (Including all taxes, T&P and labour cess but excluding GST) |
| 279 | Providing&fixing of pressures switch in M .S . pipeline including connection etc. as required (Including all taxes, T&P and labour cess but excluding GST) |
| 280 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. size 150mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 281 | SITC of Automatic starter panel suiatable for tarrace pump 10Hp complete in all respect (Including all taxes, T&P and labour cess but excluding GST) |
| 282 | Providing&fixing of hose box wall mounting type made out of 16 gauge ms sheet to accommodate 2 x15 mtr length of hose pipe , branch pipe, acrlic fronted double door, with lock two keys and break glass recess for keys painted fire red cost of materials and labour etc complete in all respect. (Including all taxes, T&P and labour cess but excluding GST) |
| 283 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. size 16 Sqmm 4 coe (Including all taxes, T&P and labour cess but excluding GST) |
| 284 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction Size 16 Sqmm 4 core (Including all taxes, T&P and labour cess but excluding GST) |
| 285 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size 16 sqmm 4 core (Including all taxes, T&P and labour cess but excluding GST) |
| 286 | Supply and fixing of fire extinguisher ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work (Including all taxes, T&P and labour cess but excluding GST) |
| 287 | Supply and fixing of fire extinguisher ,CO2 Type6.5kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. (Including all taxes, T&P and labour cess but excluding GST) |
| 288 | Supply and fixing of self glow exit signages for stair and exits made from not less then 4mm of trnsparent acralyic sheet of 300x150mm siz e with self illuminaed plastic word of 100mm height suspended from ceiling by means of MS chain or fixed of the wall as required (Including all taxes, T&P and labour cess but excluding GST) |
| 289 | Supply and fixing of four fire bucket with one stand fill with river sand supply of all materials and labour for proper completion of work. (Including all taxes, T&P and labour cess but excluding GST) |
| 290 | Externnal fire fighing for comman campus Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 150mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 291 | Sam as above but size 100 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 292 | Sam as above but size 80 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 293 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 4 way-150 mm dia M.S. Pipe (Including all taxes, T&P and labour cess but excluding GST) |
| 294 | Supplying and fixing single headed external hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Stainless steel (Including all taxes, T&P and labour cess but excluding GST) |
| 295 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Gun Metal (Including all taxes, T&P and labour cess but excluding GST) |
| 296 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required- Gun metal (Including all taxes, T&P and labour cess but excluding GST) |
| 297 | Providing&fixing of hose box wall mounting type made out of 16 gauge ms sheet to accommodate 2 x15 mtr length of hose pipe , branch pipe, acrlic fronted double door, with lock two keys and break glass recess for keys painted fire red cost of materials and labour etc complete in all respect. (Including all taxes, T&P and labour cess but excluding GST) |
| 298 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 200mm (Including all taxes, T&P and labour cess but excluding GST) |
| 299 | Same as above but size 80 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 300 | Same as above but size 100 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 301 | Same as above but size 150 mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 302 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required size 100mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 303 | Same as above but size 150mm dia (Including all taxes, T&P and labour cess but excluding GST) |
| 304 | Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room lessMRL) lift with regenerative drive as per CPWDGeneral Specification for Electrical Works (Part-III Lift& Escalator) 2003, BIS Codes, NBC 2016 asamended upto date having provision for barrier freeaccess as per Harmonised Guidelines & Standards forUniversal Accessibility in India - 2021 of MoHUA,serving different floors in the lift shaft as per detailedspecifications enclosed and as under including allother equipment and accessories complete asrequired:-(i) Speed-1.5 MPS(ii) Floors-9 (G+8)(iii) Travel -28 Meters (approx.)(iv) Stops & opening-9 stops and 9 openings(v) Controller: A.C. variable voltage & variablefrequency(vi) Automatic rescue device (ARD) complete with drymaintenance free batteries as required.vii) Operation: Microprocessor based single automaticpush button/simplex selective collective/duplexcollective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem(ix) Car Enclosure: Stainless steel scratch proof(Moon Rock/Honeycomb/ Hairline Finish) on all sidesand stainless steel decorative ceiling with fans (indirectthrow) and LED fitting.(x) The car flooring should be smooth and antiskid asapproved by engineer-in-charge.(xi) Type of doors(a) Car: Power operated, centre opening horizontalsliding stainless steel scratch proof (MoonRock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mmabove floor level to be fixed adjacent to control panelin the lift car.(xiii)Voice announcement system in the car toannounce the position of the elevator in the hoistway as the car passes or stops at floor served by theelevator. For 8 passanger ( 544 Kg ) G+8 , 9 stop (Including all taxes, T&P and labour cess but excluding GST) |
| 305 | Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room lessMRL) lift with regenerative drive as per CPWDGeneral Specification for Electrical Works (Part-III Lift& Escalator) 2003, BIS Codes, NBC 2016 asamended upto date having provision for barrier freeaccess as per Harmonised Guidelines & Standards forUniversal Accessibility in India - 2021 of MoHUA,serving different floors in the lift shaft as per detailedspecifications enclosed and as under including allother equipment and accessories complete asrequired:-(i) Speed-1.5 MPS(ii) Floors-9 (G+8)(iii) Travel -28 Meters (approx.)(iv) Stops & opening-9 stops and 9 openings(v) Controller: A.C. variable voltage & variablefrequency(vi) Automatic rescue device (ARD) complete with drymaintenance free batteries as required.vii) Operation: Microprocessor based single automaticpush button/simplex selective collective/duplexcollective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem(ix) Car Enclosure: Stainless steel scratch proof(Moon Rock/Honeycomb/ Hairline Finish) on all sidesand stainless steel decorative ceiling with fans (indirectthrow) and LED fitting.(x) The car flooring should be smooth and antiskid asapproved by engineer-in-charge.(xi) Type of doors(a) Car: Power operated, centre opening horizontalsliding stainless steel scratch proof (MoonRock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mmabove floor level to be fixed adjacent to control panelin the lift car.(xiii)Voice announcement system in the car toannounce the position of the elevator in the hoistway as the car passes or stops at floor served by theelevator. For 16passanger ( 1088 Kg ) G+8 , 9 stop (Including all taxes, T&P and labour cess but excluding GST) |
| 306 | Supplying, Installation, Testing & Commissioning of Unit Rate ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled,multi cylinder, dynamically balanced fly wheel, electricstart of suitable BHP at 1500 RPM suitable for aboveoutput of alternator at 40 0C, 50% RH & at 1000 MeterMSL , capable of taking 10% over loading for one hourafter 12 hours of continuous operation. The engine willbe with Electronic governor, Dry type Air filter withservice indicator, first filling of engine fuel (aftercommissioning) lubricating Oil, Coolant and other consumables complete with all the requiredaccessories, the Electronic governor shall be as perISO 8528.The engine shall comply to the latest CPCBnorms (CPCB IV + or better) and Conforming to BS5514, BS 649, IS 10000, IS 10002, IS 13018 and asper CPWD specifications. 160KVA (Including all taxes, T&P and labour cess but excluding GST) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail