| 1 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift up ot 1.5 M and lead up to 50M, and including filling, watering and ramming of the excavated earth into the trenches or into the space between the building and the sides of the foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 50M. from the foundation trenches. |
| 2 | Cement concrete with 4 cm gauge brick ballast, fine sand of 1.25 FM and cement in proportion of 12:6:1 in foundation & under floors, including supply of all materials, labour & T&P etc. required for proper completion of the work. |
| 3 | R.C.C. work with cement, approved coarse sand and 2cm (3/4”) gauge approved stone grit in the proportion of 1:2:4 in Raft having span upto 6.0 mtr. excluding supply of reinforcement and its bending but including its fixing and binding the same with 24B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials labour and T&P etc. required for proper completion of the work |
| 4 | R.C.C. work with cement, approved coarse sand and 2cm(3/4”) gauge approved stone grit in the proportion of 1:1.5:3 in Coloumn of doors & windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 24B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials labour and T&P etc. required for proper completion of the work. |
| 5 | M-150 class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work. |
| 6 | Filling of carted earth in trenches, plinth and sides of foundation etc. in lavers not exceeding 20 cm . in depth consolidating each deposited layer by remaining & watering and dressing and watering and dressing and including cartage of earth upto 5.00 km and all taxes required for proper completion of the work. |
| 7 | Sand filling in plinth and under floors including watering ramming, cosolidating and dressing complete including supply of all materials, labour and T&P etc. required for proper completion of work. . |
| 8 | Cost in cement conc. work with cement, approved coarse sand and 2cm(3/4”) gauge approved stone grit in the proportion of 1:2:4 in plinth beam of doors & windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 24B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials labour and T&P etc. required for proper completion of the work. |
| 9 | Painting over DPC with hot bitumen two coats of air blown………….(SI No. 4.13) knp |
| 10 | R.C.C. work with cement, approved coarse sand and 2cm (3/4”) gauge approved stone grit in the proportion of 1:2:4 in beam excluding supply of reinforcement and its bending but including its fixing and binding the same with 24B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials labour and T&P etc. required for proper completion of the work |
| 11 | R.C.C. work with cement, approved coarse sand and 2cm (3/4”) gauge approved stone grit in the proportion of 1:2:4 in SLAB having span upto 6.0 mtr. excluding supply of reinforcement and its bending but including its fixing and binding the same with 24B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials labour and T&P etc. required for proper completion of the work. |
| 12 | M-150 classbrick work in 1:6 cement and coarse sand 1(.25FM) mortar in super structure in one brick thikc wall, including necessary cutting and moulding of bricks as required and also including honey comb brick work includinig supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 13 | Mild steel or iron in plain work such as reinforced cement concrete or reinforced brick work (when not included in an overall rates), wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bends, hooks and authorized overlapping shall be measured upto floor two lever. |
| 14 | Supply and fixing of Mildsteel Z sectin openable window and grill with masquto steel jail and beading handel, stay, tower bolt etc and including supply of all materials, labour and T&P etc. required for proper coompletion of work |
| 15 | Supplying and fixing rolling shutters of approved make made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 16 | Providing and fixing ball bearing for rollig shutter. |
| 17 | Supply and fixing of 10cm internal diameter P.V.C.(6kg/cm2) down pipes complete with rose head, bends, shoes and gratings and including supply of necessary M.S.clamps 25mmx3mm size fixed to |
| 18 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.0 mm thick glass panes |
| 19 | M-150 class brick work in 1:4 cement and coarse sand 1(.25FM) mortar in super structure in Half brick thick wall, including necessasry cutting and moulding of bricks as required and also including honey comb brick work including supply o all materials, labour and T&P etc. required for proper completion of the work. |
| 20 | 12mm thick cement plaster 1:4 cement and coarse sand mortar over brickwork including supply of all materials, labour and T&P et. required for proper completion of work |
| 21 | 6 mm thick plaster in 1:3 cement and approved Fine sand (FM 1.25) mortar in celling and soffits of stairs & beams, including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 22 | 100 mm thick cement concrete flooring 1:2:4 (1cement; 2coarse sand: 4graded stone agregate of size 12.5 mm and below) laid over base concrete and finished with floating coat of neat cement excluding base conc. fixing of glass strips. (Excluding cost of glass strips) |
| 23 | 40 mm thick cement concrete flooring 1:2:4 (1cement; 2coarse sand: 4graded stone agregate of size 12.5 mm and below) laid over base concrete and finished with floating coat of neat cement with 10cm thick base concrete 1:6:12 including fixing of glass strips. (Excluding cost of glass strips) |
| 24 | Providing and fixing glass strips 3.8-4.70mm thick and 35mm wide in joints of floors |
| 25 | Providing & fixing of 6mm thick A.C sheet strips with 100 mm deep |
| 26 | Distempering two coats with Oil bound destemper of approved brand & manufacture & of required shade on undercorated wall and celling surface to give an even shade including priming coat with cement primer of approved brand & manufacture such as Bergar, J&N, Shalimar, Asian Paints after throughly brushing the surface free from mortar droppings & other foreign matter & also including preparing the surface even with plaster of paris or approved synthatic material& sand papered smooth including cost of all materials, labour & T&P etc. required for proper completion of work |
| 27 | Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade: new work two or more cleats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (apex, Ultima, weather coat all guard) asian ( 660+661.) |
| 28 | Proving and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations (A) Acplying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge overthe RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (B) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 15 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 15 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) Ater two days of proper curing applying a second coat of cement slurry using 2.75 kg sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top ayer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. \\"All above operations to be done in order and as directed and specified by the Engineer-In-Charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.With average thickness of 120 mm and minimum thickness at khurra as 65 mm.with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. \\"All above operations to be done in order and as directed and specified by the Engineer-In-Charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 29 | Painting two coats over priming coat on new steel or wood surface including priming coat with red oxide superior synthetic enamel such as berger asian neroluc LUxOL3, Higloss apcolite superlac, DULUX specified brushing to give an even shade and includinig cleaning the surface of all dirt, dust and other foreign matter, sand paperinig and stopping including cost of all materials labour tools and plants etc. required for proper completion of the work. |
| 30 | 20 mm thick cement plaster in dado skirting in 1:3 consisting of one part of cement and three parts of approved coase sand laid in panels finished with 3 mm floating coat of neat cement or cement mixed with marble dust in ratio 5:1 including supply of all material labour T&P etc. required for proper completion of work. Please Enable Macros to View BoQ information |