| Sl. No. | Item Description |
| 1 | Construction of Centre of excellence for Jila Shiksha and Prashikshan Sansthan Kanpur District-Kanpur Nagar (U.P.) |
| 2 | ADMIN BUILDINGExcavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 3 | Carted Earth filling |
| 4 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to eithe.r re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 6 | Construction of drain along with apron. 150X150MM |
| 7 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum R.C.C. work upto Plinth Lvl. (a) Tie Beam |
| 9 | (b) R.C.C.work in foundation / Footing |
| 10 | (c) R.C.C.work in Column upto Plinth Lvl. |
| 11 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (a) Lintel / Lintel Band |
| 12 | (b) R.C.C. work in slab |
| 13 | (c) R.C.C.work in Beams |
| 14 | (d) R.C.C.work in Column |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 17 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 18 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). (a) Ground Floor |
| 19 | (b) First Floor |
| 20 | (c) Mumty |
| 21 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (a) Ground Floor |
| 22 | (b) First Floor |
| 23 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 24 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 25 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 26 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 27 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 28 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (a) Ground Floor |
| 29 | (b) First Floor |
| 30 | (c) Second Floor |
| 31 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor |
| 32 | (b) First Floor |
| 33 | (c) Second Floor |
| 34 | Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng verticalLy or horizonta ly as required |
| 35 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 36 | Supply and fixing of Kota Stone in flooring 25mm thick and joint filled 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12mm base coat (bedding) of 1:2 cement & coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, tools & plants etc required for proper completion of the work. 25mm thick |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 39 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 40 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 41 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 43 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items(galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles |
| 44 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 45 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage(a) For vertical surface two coats @ 0.70 kg per sqm per coat |
| 46 | (b) For horizontal surface one coat @1.10 kg per sqm. |
| 47 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsc) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 48 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 49 | Fixing of Door, windows/ventilatiors chaukhats in position. |
| 50 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 51 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 52 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 53 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 54 | Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick (a) Single leaf |
| 55 | (b) Extra for double leaf doors |
| 56 | (c) both side laminated |
| 57 | Extra for providing lipping with 2nd class eak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 58 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 59 | Brick work with common burnt clay selected F.P.S. (non modular)bricks of class designation 7.5 in exposed brick work including makinghorizontal and vertical grooves 10 mm wide 12 mm deep complete incement mortar 1:6 (1 cement : 6 coarse sand) |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 61 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 62 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 63 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 64 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. |
| 65 | INTERNAL W/S & SANITATION (ADMIN BUILDING) |
| 66 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 67 | Providing & fixing toilet paper holder C.P. brass |
| 68 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 69 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:\\"White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap\\" |
| 71 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 72 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 73 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 74 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 75 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore |
| 76 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore |
| 77 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 78 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 79 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 80 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 81 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 82 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc. |
| 83 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal Toilet (a) 15 mm nominal outer dia Pipes |
| 85 | (b) 20 mm nominal outer dia Pipes |
| 86 | (c) 25 mm nominal outer dia Pipes |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (a) 20 mm nominal bore |
| 88 | (b) 25 mm nominal bore |
| 89 | (c) 32 mm nominal bore |
| 90 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on WallTerrace loop & Tank Filling Pipe(a) 25 mm nominal bore |
| 91 | (b) 40mm nominal bore |
| 92 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : (a) 25mm diameter pipe |
| 93 | (b) 40mm diameter pipe |
| 94 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (a) 25mm diameter pipe |
| 95 | (b) 40mm diameter pipe |
| 96 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain(a) 20 mm nominal bore |
| 97 | (b) 25mm nominal bore |
| 98 | (c) 32mm nominal bore |
| 99 | (b) 40mm nominal bore |
| 100 | (c) 50mm nominal bore |
| 101 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 25 to 40 mm nominal bore |
| 102 | (b) 50 to 80 mm nominal bore |
| 103 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 104 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. (a) 25mm dia. |
| 105 | (b) 40mm dia. |
| 106 | (c) 50mm dia. |
| 107 | (d) 65mm dia. |
| 108 | (e) 100mm dia. |
| 109 | (f) 150mm dia. |
| 110 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) |
| 111 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler 110 mm dia |
| 112 | Single tee with door 110x110x110 mm |
| 113 | Plain bend 87.5 deg 110 mm dia |
| 114 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 115 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 116 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soilPipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 117 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 118 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.Internal Toilet (Soil & Waste Pipe)(a) 75 mm |
| 119 | (b) 110 mm |
| 120 | Exposed on Wall (Soil & Waste Pipe) 110 mm |
| 121 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°)(a) 75mm |
| 122 | (b) 110mm |
| 123 | Bend without door (87.5°) (a) 75mm bend |
| 124 | (b) 110mm |
| 125 | Y' Fitting without door (a) 75mm |
| 126 | (b) 110mm |
| 127 | Single Tee without door (a) 75mm |
| 128 | (b) 110 mm |
| 129 | Single Tee with door (a) 75mm |
| 130 | (b) 110 mm |
| 131 | Bend with door (87.5°) (a) 75mm |
| 132 | (b) 110 mm |
| 133 | Clean Out Plug (COP) (a) 75mm |
| 134 | (b) 110 mm |
| 135 | Reduced 'Y' Fitting without door (a) 110mm x 75mm |
| 136 | Reduced Tee with door 110mm x 75mm |
| 137 | Coupler (a) 75mm |
| 138 | (b) 110mm |
| 139 | Vent Cowl 110mm |
| 140 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal(a) 32mm dia. Pipe |
| 141 | (b) 50mm dia. pipe |
| 142 | Elbow (45°) (a) 32mm |
| 143 | (b) 50mm |
| 144 | Elbow (90°) (a) 32mm |
| 145 | (b) 50mm |
| 146 | T fitting (a) 32mm |
| 147 | Coupler (a) 32mm |
| 148 | (b) 50mm |
| 149 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) |
| 150 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) |
| 151 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 152 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 153 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 154 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soilPipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 155 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 156 | INTERNAL ELECTRIFICATION (ADMIN BUILDING) |
| 157 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 158 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 159 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 160 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 161 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 162 | (d) 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 163 | (e) 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 164 | (d) 4 x 16 sq.mm + 2 x 6 sq.mm. earth wire |
| 165 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 166 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 167 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 168 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 169 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 170 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 171 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 172 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 173 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 174 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 175 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degcentigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)22 watt |
| 176 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)18- 22 watt |
| 177 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim8 - 10 watt |
| 178 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 179 | Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 180 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 181 | Supply, Installation, Testing and Commissioning of 400mm wall mounted single phase Wall Fan complete in all respect as per engineer in charge. |
| 182 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 183 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (a) 63 A,25KA,FP MCCB |
| 184 | (b) 100 A,30KA,FPMCCB |
| 185 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way Double door |
| 186 | (b) 8 way Double door |
| 187 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door |
| 188 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 40 amps 4P MCB |
| 189 | (b) 63 amps 4P MCB |
| 190 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. (a) 25 amps |
| 191 | (b) 40 amps |
| 192 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 193 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 194 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 195 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 196 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 197 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 198 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 199 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 2 Pair (4 core) |
| 200 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. 5 Pair telephone cable |
| 201 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 5 Pair tag block |
| 202 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia PVC conduit |
| 203 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 204 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) Telephone socket outlet |
| 205 | (b) RJ-45 Data Socket outlet |
| 206 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 207 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Up to 35 sq.mm. |
| 208 | (b) Above 35 sq.mm. and up to 95 sq.mm. |
| 209 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required (a) Up to 35 sq.mm. |
| 210 | (d) Above 35 sq.mm. and up to 95 sq.mm. |
| 211 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required (a) Upto 35 sq. mm (clamped with 1mm thick saddle |
| 212 | (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 213 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (a) 3.5 x 50 sq.mm |
| 214 | (b) 4 x 16 sq.mm |
| 215 | (c) 3 x 6 sq.mm |
| 216 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 2 X 6 sq. mm (19mm) |
| 217 | (b) 3½ X 50 sq. mm (35mm) |
| 218 | (c) 4 X 16 sq. mm (28mm) |
| 219 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
| 220 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 221 | FIRE FIGHTING (ADMIN BUILDING) |
| 222 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 100 mm dia. |
| 223 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 224 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 225 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 226 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 227 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) |
| 228 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) |
| 229 | Providing & fixing of Anti vibration Expansion Bellow at pump inlet and outlet etc. as required. 100 mm dia. |
| 230 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump) |
| 231 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia. |
| 232 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 233 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 234 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (a) 80 mm nominal bore |
| 235 | (b) 100 mm nominal bore |
| 236 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 237 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m |
| 238 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal |
| 239 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
| 240 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. |
| 241 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height) |
| 242 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 243 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 244 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 245 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 246 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 247 | Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor) |
| 248 | Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 4 Core, X 6 sqmm. |
| 249 | Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 4 Core, X 6 sqmm. |
| 250 | Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 2 x 2.5 sq.mm |
| 251 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. |
| 252 | FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 253 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 254 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 255 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 256 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. |
| 257 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 258 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 259 | ACADEMIC BUILDINGExcavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 260 | Carted Earth filling |
| 261 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to eithe.r re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 262 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 263 | Construction of drain along with apron. 150X150MM |
| 264 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 265 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the followinggrades of concrete.: Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cementcontent of 330 kg /cum R.C.C. work upto Plinth Lvl. (a) R.C.C. TIE Beam |
| 266 | (b) R.C.C.work in foundation / Footing |
| 267 | (c) R.C.C.work in Column upto Plinth Lvl. |
| 268 | Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (a) Lintel / Lintel Band |
| 269 | (b) R.C.C. work in slab |
| 270 | (c) R.C.C.work in Beams |
| 271 | (d) R.C.C.work in Column |
| 272 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6(1 cement : 6 coarse sand) |
| 273 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 274 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 275 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). (a) Ground Floor |
| 276 | (b) First Floor |
| 277 | (c) Second Floor |
| 278 | (d) Mumty |
| 279 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (a) Ground Floor |
| 280 | (b) First Floor |
| 281 | (c) Second Floor |
| 282 | (d) Mumty |
| 283 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 284 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 285 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 286 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 287 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 288 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (a) Ground Floor |
| 289 | (b) First Floor |
| 290 | (c) Second Floor |
| 291 | (d) Mumty |
| 292 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor |
| 293 | (b) First Floor |
| 294 | (c) Second Floor |
| 295 | (d) Mumty |
| 296 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 297 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 298 | Supply and fixing of Kota Stone in flooring 25mm thick and joint filled 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12mm base coat (bedding) of 1:2 cement & coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, tools & plants etc required for proper completion of the work. 25mm thick |
| 299 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 300 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 301 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 302 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 303 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 304 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 305 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 306 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 307 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 308 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage(a) For vertical surface two coats @ 0.70 kg per sqm per coat |
| 309 | (b) For horizontal surface one coat @1.10 kg per sqm. |
| 310 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cementadmixed with water proofing compound conforming to IS. 2645 andapproved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cementmortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-chargeto required slope and treating similarly the adjoining walls upto 300 mmheight including rounding of junctions of walls and slabs.pattern of 300x300 mm square 3 mm deep.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with nea(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thicknessat khurra as 65 mm\\" |
| 311 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 312 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 313 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 314 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 315 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 316 | Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick (a) Single leaf |
| 317 | (b) Extra for double leaf doors |
| 318 | (c) both side laminated |
| 319 | Extra for providing lipping with 2nd class eak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 320 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 321 | Brick work with common burnt clay machine moulded modular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).Above plinth level upto floor V level |
| 322 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 323 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 324 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 325 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. |
| 326 | INTERNAL W/S & SANITATION (ACADEMIC BUILDING) |
| 327 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 328 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 329 | Providing & fixing toilet paper holder C.P. brass |
| 330 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 331 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 332 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 333 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 334 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 335 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 336 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 337 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore |
| 338 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore |
| 339 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm |
| 340 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe32mm Dia |
| 341 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 342 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 343 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 344 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 345 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 346 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc. |
| 347 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 348 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal Toilet (a) 15 mm nominal outer dia Pipes |
| 349 | (b) 20 mm nominal outer dia Pipes |
| 350 | (c) 25 mm nominal outer dia Pipes |
| 351 | (d) 32 mm nominal outer dia Pipes |
| 352 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (a) 20mm diameter pipe |
| 353 | (b) 25mm diameter pipe |
| 354 | (c) 32mm diameter pipe |
| 355 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on WallTerrace loop & Tank Filling Pipe(a) 20mm diameter pipe |
| 356 | (b) 25mm diameter pipe |
| 357 | (c) 32mm diameter pipe |
| 358 | (d) 40mm diameter pipe |
| 359 | (e) 50mm diameter pipe |
| 360 | (f) 65mm diameter pipe |
| 361 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : (a) 20mm diameter pipe |
| 362 | (b) 25mm diameter pipe |
| 363 | (c) 32mm diameter pipe |
| 364 | (d) 40mm diameter pipe |
| 365 | (e) 50mm diameter pipe |
| 366 | (f) 65mm diameter pipe |
| 367 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (a) 20mm diameter pipe |
| 368 | (b) 25mm diameter pipe |
| 369 | (c) 32mm diameter pipe |
| 370 | (d) 40mm diameter pipe |
| 371 | (e) 50mm diameter pipe |
| 372 | (f) 65mm diameter pipe |
| 373 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain(a) 20 mm nominal bore |
| 374 | (b) 25mm nominal bore |
| 375 | (c) 32mm nominal bore |
| 376 | (d) 40mm nominal bore |
| 377 | (e) 50mm nominal bore |
| 378 | (f) 65mm nominal bore |
| 379 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 25 to 40 mm nominal bore |
| 380 | (b) 50 to 80 mm nominal bore |
| 381 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 382 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. (a) 25mm dia. |
| 383 | (d) 50mm dia. |
| 384 | (e) 65mm dia. |
| 385 | (g) 100mm dia. |
| 386 | (h) 150mm dia. |
| 387 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) |
| 388 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler110 mm dia |
| 389 | Single tee with door 110x110x110 mm |
| 390 | Plain bend 87.5 deg 110 mm dia |
| 391 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 392 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 393 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 394 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 395 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.Internal Toilet (Soil & Waste Pipe)(a) 75 mm |
| 396 | (b) 110 mm |
| 397 | Exposed on Wall (Soil & Waste Pipe) 110 mm |
| 398 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°) (a) 75mm |
| 399 | (b) 110mm |
| 400 | Bend without door (87.5°) (a) 75mm bend |
| 401 | (b) 110mm |
| 402 | Y' Fitting without door (a) 75mm |
| 403 | (b) 110mm |
| 404 | Single Tee without door (a) 75mm |
| 405 | (b) 110 mm |
| 406 | Single Tee with door (a) 75mm |
| 407 | (b) 110 mm |
| 408 | Bend with door (87.5°) (a) 75mm |
| 409 | (b) 110 mm |
| 410 | Clean Out Plug (COP) (a) 75mm |
| 411 | (b) 110 mm |
| 412 | Reduced 'Y' Fitting without door 110mm x 75mm |
| 413 | Reduced Tee with door 110mm x 75mm |
| 414 | Coupler (a) 75mm |
| 415 | (b) 110mm |
| 416 | Vent Cowl 110mm |
| 417 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal(a) 32mm dia. Pipe |
| 418 | (b) 50mm dia. pipe |
| 419 | Elbow (45°) (a) 32mm |
| 420 | (b) 50mm |
| 421 | Elbow (90°) (a) 32mm |
| 422 | (b) 50mm |
| 423 | T fitting (a) 32mm |
| 424 | (b) 50mm |
| 425 | Coupler (a) 32mm |
| 426 | (b) 50mm |
| 427 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) |
| 428 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) |
| 429 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 430 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 431 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 432 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soilPipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 433 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 434 | INTERNAL ELECTRIFICATION (ACADIMIC BUILDING) |
| 435 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 436 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 437 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 438 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 439 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 440 | (d) 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 441 | (e) 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 442 | (f) 4 x 16 sq.mm + 2 x 6 sq.mm. earth wire |
| 443 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 444 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 445 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 446 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 447 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 448 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 449 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 450 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 451 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 452 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 453 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 degcentigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)36 watt |
| 454 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)(a) 18- 22 watt |
| 455 | (b) 40 watt |
| 456 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim 8 - 10 watt |
| 457 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 458 | Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 459 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 460 | Supply, Installation, Testing and Commissioning of 400mm wall mounted single phase Wall Fan complete in all respect as per engineer in charge. |
| 461 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 462 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (a) 63 A,25KA,FP MCCB |
| 463 | (b) 100 A,30KA,FPMCCB |
| 464 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way Double door |
| 465 | (b) 8 way Double door |
| 466 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door |
| 467 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 63 amps TP MCB |
| 468 | (b) 40 amps 4P MCB |
| 469 | (c) 63 amps 4P MCB |
| 470 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. (a) 25 amps |
| 471 | (b) 40 amps |
| 472 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 473 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 474 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 475 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel should be manufactured as per detailed SLD.) The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmMain LT PanelIncoming :One (1) No 250 Amp. 4P MCCB of 25KA Breaking capacity Metering :1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter1 Set of Phase Indication Lamp.Bus Bar :One (1) No. 315 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.125 Amps FP MCCB of 25KA - 2 No100 Amps FP MCCB of 25KA - 1 No63 Amps FP MCCB of 25KA - 6 No40 Amps FP MCB of 25KA - 1 No2 No. Space for SparePanel described as above |
| 476 | ELEVATOR PANELIncoming :One (1) No 63 Amp. 4P MCCB of 25KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incomingOne (1) No. of Phase Indication Lamp each incomingBus Bar : One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.40 Amps FP MCCB of 25KA - 1 No32 Amps DP MCB of 10KA - 1 No2 No. Space for SparePanel described as above |
| 477 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 478 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 479 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 480 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 481 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20mm dia PVC conduit |
| 482 | (b) 25mm dia PVC conduit |
| 483 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 484 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ-45 Data Socket outlet |
| 485 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 486 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Up to 35 sq.mm. |
| 487 | (b) Above 185 sq.mm. and up to 400 sq.mm. |
| 488 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required (a) Up to 35 sq.mm. |
| 489 | (b) Above 185 sq.mm. and up to 400 sq.mm. |
| 490 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requiredUpto 35 sq. mm (clamped with 1mm thick saddle |
| 491 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 492 | (b) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 493 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (a) 3.5 x 300 sq.mm. |
| 494 | (b) 3.5 x 35 sq.mm |
| 495 | (c) 3.5 x 25 sq.mm. |
| 496 | (d) 4 x 16 sq.mm |
| 497 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 3½ X 25 sq. mm (28mm) |
| 498 | (b) 3½ X 35 sq. mm (32mm) |
| 499 | (c) 3½ X 300 sq. mm (70mm) |
| 500 | (d) 4 X 16 sq. mm (28mm) |
| 501 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
| 502 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 503 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 504 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 505 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 506 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. For lightining Conductor |
| 507 | Providing and fixing of lightning conductor finial , made of 25mm dia 300mm long Copper tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required. |
| 508 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 509 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) |
| 510 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 511 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 512 | FIRE FIGHTING (ACADEMIC BUILDING) |
| 513 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 100 mm dia. |
| 514 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 515 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 516 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 517 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 518 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) |
| 519 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) |
| 520 | Providing & fixing of Anti vibration Expansion Bellow at pump inlet and outlet etc. as required. 100 mm dia. |
| 521 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump) |
| 522 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia. |
| 523 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 524 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : (a) 100 mm dia. |
| 525 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (a) 80 mm nominal bore |
| 526 | (b) 100 mm nominal bore |
| 527 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 528 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m |
| 529 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal |
| 530 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
| 531 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. |
| 532 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height) |
| 533 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 534 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 535 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 536 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 537 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 538 | Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor) |
| 539 | Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 4 Core, X 6 sqmm. |
| 540 | Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 4 Core, X 6 sqmm. |
| 541 | Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 2 x 2.5 sq.mm |
| 542 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness. |
| 543 | GIRL'S HOSTELExcavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 544 | Carted Earth filling |
| 545 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to eithe.r re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 546 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 547 | Construction of drain along with apron. 150X150MM |
| 548 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 549 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C. work in (a) Plinth Band |
| 550 | (b) R.C.C.work in foundation / Footing |
| 551 | (c) R.C.C.work in Column upto Plinth Lvl. |
| 552 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (a) Lintel / Lintel Band |
| 553 | (b) R.C.C. work in slab |
| 554 | (b) R.C.C.work in Beams |
| 555 | (c) R.C.C.work in Column |
| 556 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 557 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 558 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 559 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). (a) Ground Floor |
| 560 | (b) First Floor |
| 561 | (c) Mumty |
| 562 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (a) Ground Floor |
| 563 | (b) First Floor |
| 564 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 565 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 566 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 567 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 568 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 569 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (a) Ground Floor |
| 570 | (b) First Floor |
| 571 | (c) Mumty |
| 572 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor |
| 573 | (b) First Floor |
| 574 | Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng verticalLy or horizonta ly as required |
| 575 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 576 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 577 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 578 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 579 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 580 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 581 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 582 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 583 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 584 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 585 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 586 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage (a) For vertical surface two coats @ 0.70 kg per sqm per coat |
| 587 | (b) For horizontal surface one coat @1.10 kg per sqm. |
| 588 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsc) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 589 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 590 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 591 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 592 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 593 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 594 | Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick (a) Single leaf |
| 595 | (b) Extra for double leaf doors |
| 596 | (c) both side laminated |
| 597 | Extra for providing lipping with 2nd class eak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 598 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 599 | Brick work with common burnt clay selected F.P.S. (non modular)bricks of class designation 7.5 in exposed brick work including makinghorizontal and vertical grooves 10 mm wide 12 mm deep complete incement mortar 1:6 (1 cement : 6 coarse sand) |
| 600 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws with Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both side laminated. |
| 601 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 602 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 603 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 604 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. |
| 605 | INTERNAL W/S & SANITATION (GIRL'S HOSTEL) |
| 606 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 607 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 608 | Providing & fixing toilet paper holder C.P. brass |
| 609 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 610 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 611 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 612 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 613 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 614 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 615 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 616 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore |
| 617 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length15 mm nominal bore |
| 618 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter |
| 619 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 620 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 621 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 622 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board510x1040 mm bowl depth 200 mm |
| 623 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe32mm Dia |
| 624 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 625 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 626 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 627 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc. |
| 628 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 629 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal Toilet (a) 15 mm nominal outer dia Pipes |
| 630 | (b) 20 mm nominal outer dia Pipes |
| 631 | (c) 25 mm nominal outer dia Pipes |
| 632 | (d) 32 mm nominal outer dia Pipes |
| 633 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (a) 20 mm nominal bore |
| 634 | (b) 25 mm nominal bore |
| 635 | (c) 32 mm nominal bore |
| 636 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on WallTerrace loop & Tank Filling Pipe(a) 20 mm nominal bore |
| 637 | (b) 25 mm nominal bore |
| 638 | (c) 40mm nominal bore |
| 639 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 20mm diameter pipe |
| 640 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 25mm diameter pipe |
| 641 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 40mm diameter pipe |
| 642 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20mm diameter pipe |
| 643 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25mm diameter pipe |
| 644 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40mm diameter pipe |
| 645 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : For vertical pipe connection with terrace ringmain(a) 20 mm nominal bore |
| 646 | (b) 25mm nominal bore |
| 647 | (c) 32mm nominal bore |
| 648 | (d) 40mm nominal bore |
| 649 | (e) 50mm nominal bore |
| 650 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 25 to 40 mm nominal bore |
| 651 | (b) 50 to 80 mm nominal bore |
| 652 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 653 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. (a) 25mm dia. |
| 654 | (b) 40mm dia. |
| 655 | (c) 50mm dia. |
| 656 | (d) 65mm dia. |
| 657 | (e) 100mm dia. |
| 658 | (f) 150mm dia. |
| 659 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) |
| 660 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler110 mm dia |
| 661 | Single tee with door 110x110x110 mm |
| 662 | Plain bend 87.5 deg 110 mm dia |
| 663 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 664 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 665 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 666 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 667 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil & Waste Pipe) (a) 75 mm |
| 668 | (b) 110 mm |
| 669 | Exposed on Wall (Soil & Waste Pipe) 110 mm |
| 670 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°)(a) 75mm |
| 671 | (b) 110mm |
| 672 | Bend without door (87.5°) (a) 75mm bend |
| 673 | (b) 110mm |
| 674 | Y' Fitting without door (a) 75mm |
| 675 | (b) 110mm |
| 676 | Single Tee without door (a) 75mm |
| 677 | (b) 110 mm |
| 678 | Single Tee with door (a) 75mm |
| 679 | (b) 110 mm |
| 680 | Bend with door (87.5°) (a) 75mm |
| 681 | (b) 110 mm |
| 682 | Clean Out Plug (COP) (a) 75mm |
| 683 | (b) 110 mm |
| 684 | Reduced Tee with door 110mm x 75mm |
| 685 | Coupler (a) 75mm |
| 686 | (b) 110mm |
| 687 | Vent Cowl 110mm |
| 688 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 32mm dia. Pipe |
| 689 | Elbow (45°) 32mm |
| 690 | Elbow (90°) 32mm |
| 691 | T fitting 32mm |
| 692 | Coupler 32mm |
| 693 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) |
| 694 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) |
| 695 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 696 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 697 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 698 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 699 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 700 | INTERNAL ELECTRIFICATION (GIRL'S HOSTEL) |
| 701 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 702 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 703 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 704 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 705 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 706 | (d) 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 707 | (e) 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 708 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 709 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 710 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 711 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 712 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 713 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 714 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 715 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 716 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 717 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 718 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)(a) 18- 22 watt |
| 719 | (b) 40 watt |
| 720 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim8 - 10 watt |
| 721 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 722 | Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 723 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 724 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 725 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)50 watt |
| 726 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 727 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 728 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB |
| 729 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way Double door |
| 730 | (b) 8 way Double door |
| 731 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 40 amps TP MCB |
| 732 | (b) 40 amps 4P MCB |
| 733 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps |
| 734 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 735 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 736 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 737 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 738 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 739 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 740 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 741 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ-45 Data Socket outlet |
| 742 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 743 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 35 sq.mm. and up to 95 sq.mm. |
| 744 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required (a) Upto 35 sq. mm (clamped with 1mm thick saddle |
| 745 | (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 746 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (a) 3.5 x 70 sq.mm |
| 747 | (b) 3.5 x 35 sq.mm |
| 748 | (c) 4 x 16 sq.mm |
| 749 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 3½ X 35 sq. mm (32mm) |
| 750 | (b) 3½ X 70 sq. mm (38mm) |
| 751 | (c) 4 X 16 sq. mm (28mm) |
| 752 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
| 753 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 754 | FIRE FIGHTING (GIRL'S) |
| 755 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 100 mm dia. |
| 756 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 757 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 758 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 759 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 760 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) |
| 761 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) |
| 762 | Providing & fixing of Anti vibration Expansion Bellow at pump inlet and outlet etc. as required. 100 mm dia. |
| 763 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump) |
| 764 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia. |
| 765 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 766 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 767 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (a) 80 mm nominal bore |
| 768 | (b) 100 mm nominal bore |
| 769 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 770 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m |
| 771 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal |
| 772 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Gun metal |
| 773 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. |
| 774 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height) |
| 775 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 776 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 777 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 778 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 779 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 780 | Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor) |
| 781 | Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 4 Core, X 6 sqmm. |
| 782 | Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 4 Core, X 6 sqmm. |
| 783 | Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 2 x 2.5 sq.mm |
| 784 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. |
| 785 | BOY'S HOSTELExcavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 786 | Carted Earth filling |
| 787 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to eithe.r re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 788 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 789 | Construction of drain along with apron. 150X150MM |
| 790 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 791 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C. work in (a) Plinth Band |
| 792 | (b) R.C.C.work in foundation / Footing |
| 793 | (c) R.C.C.work in Column upto Plinth Lvl. |
| 794 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (a) Lintel/Lintel Band |
| 795 | (b) R.C.C. work in slab |
| 796 | (c) R.C.C.work in Beams |
| 797 | (d) R.C.C.work in Column |
| 798 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 799 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 800 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 801 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). (a) Ground Floor |
| 802 | (b) First Floor |
| 803 | (c) Mumty |
| 804 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (a) Ground Floor |
| 805 | (b) First Floor |
| 806 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 807 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 808 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 809 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 810 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 811 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (a) Ground Floor |
| 812 | (b) First Floor |
| 813 | (c) Mumty |
| 814 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor |
| 815 | (b) First Floor |
| 816 | Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng verticalLy or horizonta ly as required |
| 817 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 818 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 819 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 820 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 821 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 822 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 823 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 824 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 825 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 826 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 827 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 828 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage (a) For vertical surface two coats @ 0.70 kg per sqm per coat |
| 829 | (b) For horizontal surface one coat @1.10 kg per sqm. |
| 830 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsc) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 831 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 832 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 833 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 834 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 835 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 836 | Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick (a) Single leaf |
| 837 | (b) Extra for double leaf doors |
| 838 | (c) both side laminated |
| 839 | Extra for providing lipping with 2nd class eak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 840 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 841 | Brick work with common burnt clay selected F.P.S. (non modular)bricks of class designation 7.5 in exposed brick work including makinghorizontal and vertical grooves 10 mm wide 12 mm deep complete incement mortar 1:6 (1 cement : 6 coarse sand) |
| 842 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws with Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both side laminated. |
| 843 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 844 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 845 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 846 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. |
| 847 | INTERNAL W/S & SANITATION (BOY'S HOSTEL) |
| 848 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 849 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 850 | Providing & fixing toilet paper holder C.P. brass |
| 851 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 852 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 853 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 854 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 855 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 856 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 857 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 858 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore |
| 859 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 860 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter |
| 861 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 862 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 863 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 864 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board510x1040 mm bowl depth 200 mm |
| 865 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe32mm Dia |
| 866 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 867 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 868 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 869 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 870 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 871 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr) including all its accessories, complete in all respect including testing etc. |
| 872 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 873 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal Toilet (a) 15 mm nominal outer dia Pipes |
| 874 | (b) 20 mm nominal outer dia Pipes |
| 875 | (c) 25 mm nominal outer dia Pipes |
| 876 | (d) 32 mm nominal outer dia Pipes |
| 877 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (a) 20 mm nominal bore |
| 878 | (b) 25 mm nominal bore |
| 879 | (c) 32 mm nominal bore |
| 880 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on WallTerrace loop & Tank Filling Pipe(a) 20 mm nominal bore |
| 881 | (b) 25 mm nominal bore |
| 882 | (c) 40mm nominal bore |
| 883 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : (a) 20mm diameter pipe |
| 884 | (b) 25mm diameter pipe |
| 885 | (c) 40mm diameter pipe |
| 886 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (a) 20mm diameter pipe |
| 887 | (b) 25mm diameter pipe |
| 888 | (c) 40mm diameter pipe |
| 889 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain(a) 20 mm nominal bore |
| 890 | (b) 25mm nominal bore |
| 891 | (c) 32mm nominal bore |
| 892 | (d) 40mm nominal bore |
| 893 | (e) 50mm nominal bore |
| 894 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 25 to 40 mm nominal bore |
| 895 | (b) 50 to 80 mm nominal bore |
| 896 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 897 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. (a) 25mm dia. |
| 898 | (b) 40mm dia. |
| 899 | (c) 50mm dia. |
| 900 | (d) 65mm dia. |
| 901 | (e) 100mm dia. |
| 902 | (f) 150mm dia. |
| 903 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) |
| 904 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler 110 mm dia |
| 905 | Single tee with door 110x110x110 mm |
| 906 | Plain bend 87.5 deg 110 mm dia |
| 907 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 908 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 909 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 910 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 911 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.Internal Toilet (Soil & Waste Pipe)(a) 75 mm |
| 912 | (b) 110 mm |
| 913 | Exposed on Wall (Soil & Waste Pipe) 110 mm |
| 914 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) (a) 75mm |
| 915 | (b) 110mm |
| 916 | Bend without door (87.5°) (a) 75mm bend |
| 917 | (b) 110mm |
| 918 | Y' Fitting without door (a) 75mm |
| 919 | (b) 110mm |
| 920 | Single Tee without door (a) 75mm |
| 921 | (b) 110 mm |
| 922 | Single Tee with door (a) 75mm |
| 923 | (b) 110 mm |
| 924 | Bend with door (87.5°) (a) 75mm |
| 925 | (b) 110 mm |
| 926 | Clean Out Plug (COP) (a) 75mm |
| 927 | (b) 110 mm |
| 928 | Reduced 'Y' Fitting without door 110mm x 75mm |
| 929 | Reduced Tee with door 110mm x 75mm |
| 930 | Coupler (a) 75mm |
| 931 | (b) 110mm |
| 932 | Vent Cowl 110mm |
| 933 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal(a) 32mm dia. Pipe |
| 934 | (b) 50mm dia. Pipe |
| 935 | Elbow (45°) (a) 32mm |
| 936 | 9b) 50mm |
| 937 | Elbow (90°) (a) 32mm |
| 938 | (b) 50mm |
| 939 | T fitting (a) 32mm |
| 940 | (b) 50mm |
| 941 | Coupler(a) 32mm |
| 942 | (b) 50mm |
| 943 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) |
| 944 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) |
| 945 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 946 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 947 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 948 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soilPipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 949 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 950 | INTERNAL ELECTRIFICATION (BOY'S HOSTEL) |
| 951 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 952 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 953 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 954 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 955 | (c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 956 | (d) 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 957 | (e) 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 958 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 959 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 960 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 961 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 962 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 963 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 964 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 965 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 966 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 967 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 968 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)(a) 18- 22 watt |
| 969 | (b) 40 watt |
| 970 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim8 - 10 watt |
| 971 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 972 | Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 973 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 974 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 975 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)50 watt |
| 976 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 977 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 978 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB |
| 979 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way Double door |
| 980 | (b) 8 way Double door |
| 981 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 40 amps TP MCB |
| 982 | (b) 40 amps 4P MCB |
| 983 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps |
| 984 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 985 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 986 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 987 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 988 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 989 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 990 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 991 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ-45 Data Socket outlet |
| 992 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 993 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 35 sq.mm. and up to 95 sq.mm. |
| 994 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required (a) Upto 35 sq. mm (clamped with 1mm thick saddle |
| 995 | (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 996 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (a) 3.5 x 70 sq.mm |
| 997 | (b) 3.5 x 35 sq.mm |
| 998 | (c) 4 x 16 sq.mm |
| 999 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 3½ X 35 sq. mm (32mm) |
| 1000 | (b) 3½ X 70 sq. mm (38mm) |
| 1001 | (c) 4 X 16 sq. mm (28mm) |
| 1002 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
| 1003 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1004 | FIRE FIGHTING (BOY'S HOSTEL) |
| 1005 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 100 mm dia. |
| 1006 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 1007 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 1008 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 1009 | \\"Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump)\\"(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 1010 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) |
| 1011 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) |
| 1012 | Providing & fixing of Anti vibration Expansion Bellow at pump inlet and outlet etc. as required. 100 mm dia. |
| 1013 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump) |
| 1014 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia. |
| 1015 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. |
| 1016 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. |
| 1017 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (a) 80 mm nominal bore |
| 1018 | (b) 100 mm nominal bore |
| 1019 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 1020 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m |
| 1021 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal |
| 1022 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
| 1023 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. |
| 1024 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door: 900mm Wide & 1500mm Height) |
| 1025 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 1026 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 1027 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 1028 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 1029 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 1030 | Fabricating & Supply, installing, testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle. (As per the Technical Specifications) (At Terrace floor) |
| 1031 | Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 4 Core, X 6 sqmm. |
| 1032 | Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 4 Core, X 6 sqmm. |
| 1033 | Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 2 x 2.5 sq.mm |
| 1034 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. |
| 1035 | RESIDENTIAL BLOCK TYPE-2, 2 NO. |
| 1036 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1037 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1038 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to eithe.r re-design the mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 1039 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 1040 | Construction of drain along with apron. 150X150MM |
| 1041 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 1042 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) , R.C.C. work upto Plinth Lvl. (a) Plinth Band |
| 1043 | (b) R.C.C.work in foundation / Footing |
| 1044 | (c) R.C.C.work in Column upto Plinth Lvl. |
| 1045 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). R.C.C. works above plinth lvl (a) Lintel / Lintel Band |
| 1046 | (b) R.C.C. work in slab |
| 1047 | (c) R.C.C.work in Beams |
| 1048 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1049 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1050 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 1051 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 1052 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand). (a) Ground Floor |
| 1053 | (b) First Floor |
| 1054 | (c) TERRACE |
| 1055 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (a) Ground Floor |
| 1056 | (b) First Floor |
| 1057 | Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick (a) Single leaf |
| 1058 | (b) both side laminated |
| 1059 | Extra for providing lipping with 2nd class eak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 1060 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 1061 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 1062 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 1063 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters , with ISI marked M.S. pressed butt hinges bright finished of required size , Second class teak wood |
| 1064 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1065 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 1066 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (a) Ground Floor |
| 1067 | (b) First Floor |
| 1068 | (c) TERRACE FLOOR |
| 1069 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (a) Ground Floor |
| 1070 | (b) First Floor |
| 1071 | (c) TERRACE FLOOR |
| 1072 | 6 mm cement plaster of mix :. 1:3 (1 cement : 3 fine sand) |
| 1073 | Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng verticalLy or horizonta ly as required |
| 1074 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 1075 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 1076 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 1077 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 1078 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 1079 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. |
| 1080 | Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. |
| 1081 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1082 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 1083 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1084 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 1085 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage (a) For vertical surface two coats @ 0.70 kg per sqm per coat |
| 1086 | (b) For horizontal surface one coat @1.10 kg per sqm. |
| 1087 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsc) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 1088 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 1089 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 1090 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 1091 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 1092 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 1093 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws with Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both side laminated. |
| 1094 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : , 25 mm dia |
| 1095 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 1096 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 1097 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1098 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. |
| 1099 | INTERNAL W/S & SANITATION (RESIDENTIAL BLOCK TYPE 2) |
| 1100 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 1101 | Providing & fixing toilet paper holder C.P. brass |
| 1102 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 1103 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 1104 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 1105 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1106 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 1107 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 1108 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1109 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore |
| 1110 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 1111 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter |
| 1112 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 1113 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 1114 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 1115 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board510x1040 mm bowl depth 200 mm |
| 1116 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe 32mm Dia |
| 1117 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 1118 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 1119 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 1120 | Providing and fixing of storage type (pressurised type) electric hot water heater copper sheet container, 25 mm thick insulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters |
| 1121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Internal Toilet (a) 15 mm nominal outer dia Pipes |
| 1122 | (b) 20 mm nominal outer dia Pipes |
| 1123 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal bore |
| 1124 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall Terrace loop & Tank Filling Pipe 25 mm nominal bore |
| 1125 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 25mm diameter pipe |
| 1126 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25mm diameter pipe |
| 1127 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : For vertical pipe connection with terrace ringmain (a) 20 mm nominal bore |
| 1128 | (b) 25mm nominal bore |
| 1129 | (c) 32mm nominal bore |
| 1130 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 1131 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 25 mm nominal bore, 152 mm long, weighing not less than 440 gms |
| 1132 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1133 | Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral or equivalent approved complete in all respect as directed by Engineer-in-charge. (a) 15mm dia (9 mm thickness) |
| 1134 | (b) 20mm dia (9 mm thickness) |
| 1135 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) |
| 1136 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler 110 mm dia |
| 1137 | Single tee with door 110x110x110 mm |
| 1138 | Plain bend 87.5 deg 110 mm dia |
| 1139 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia |
| 1140 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 1141 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil & Waste Pipe) (a) 75 mm |
| 1142 | (b) 110 mm |
| 1143 | Exposed on Wall (Soil & Waste Pipe) 110 mm |
| 1144 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°) (a) 75mm |
| 1145 | (b) 110mm |
| 1146 | Bend without door (87.5°) (a) 75mm bend |
| 1147 | (b) 110mm |
| 1148 | Y' Fitting without door (a) 75mm |
| 1149 | (b) 110mm |
| 1150 | Single Tee without door (a) 75mm |
| 1151 | (b) 110 mm |
| 1152 | Single Tee with door (a) 75mm |
| 1153 | (b) 110 mm |
| 1154 | Bend with door (87.5°) (a) 75mm |
| 1155 | (b) 110 mm |
| 1156 | Reduced Tee with door (a) 110mm x 75mm |
| 1157 | Coupler (a) 75mm |
| 1158 | (b) 110mm |
| 1159 | Vent Cowl 110mm |
| 1160 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. (a) For Wash basin & Urinal 32mm dia. Pipe |
| 1161 | (b) Elbow (45°) 32mm |
| 1162 | (c) Elbow (90°) 32mm |
| 1163 | (d) T fitting 32mm |
| 1164 | (e) Coupler 32mm |
| 1165 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) |
| 1166 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) |
| 1167 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 32mm dia. Pipe |
| 1168 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1169 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 1170 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 1171 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100mm dia SW pipe |
| 1172 | INTERNAL ELECTRIFICATION (RESIDENTIAL BLOCK TYPE-2) |
| 1173 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1174 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1175 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1176 | (c) 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 1177 | (d) 2 x 10 sq.mm + 1 x 6 sq.mm. earth wire |
| 1178 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 1179 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 1180 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 1181 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 1182 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 1183 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1184 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1185 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 1186 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 1187 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 1188 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 1189 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)18- 22 watt |
| 1190 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 1191 | Supplying of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 1192 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1193 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 1194 | \\"LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)\\"50 watt |
| 1195 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1196 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 1197 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door |
| 1198 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 1199 | (b) Double pole |
| 1200 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1201 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel should be manufactured as per detailed SLD.) The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.Meter Panel Board-TYPE-IIIncoming : One (1) No 125 Amp. 4P MCCB of 25KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incomingOne (1) No. of Phase Indication Lamp each incomingBus Bar : One (1) No. 150Amp.TPN aluminimum bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.32 Amps DP MCB of 10KA - 3 NoSINGLE PHASE ENERGY METER - 3 No2 No. SPACE FOR SPAREPanel described as above |
| 1202 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1203 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1204 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 1205 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1206 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 2 Pair (4 core) |
| 1207 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. 5 Pair telephone cable |
| 1208 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 5 Pair tag block |
| 1209 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20mm dia PVC conduit |
| 1210 | (b) 25mm dia PVC conduit |
| 1211 | (c) 32mm dia PVC conduit |
| 1212 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 1213 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) Telephone socket outlet |
| 1214 | (b) TV antenna socket outlet |
| 1215 | (c) Bell Push |
| 1216 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 1217 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 1218 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1219 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (a) 3.5 x 35 sq.mm |
| 1220 | (b) 3 x 6 sq.mm |
| 1221 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 2 X 6 sq. mm (19mm) |
| 1222 | (b) 3½ X 35 sq. mm (32mm) |
| 1223 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. (a) 150 mm dia |
| 1224 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1225 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 1226 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 1227 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 1228 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. For lightining Conductor |
| 1229 | Providing and fixing of lightning conductor finial , made of 25mm dia 300mm long Copper tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required. |
| 1230 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 1231 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) |
| 1232 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 1233 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 1234 | BLOCK 1 AND BLOCK 2 |
| 1235 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm |
| 1236 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 1237 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In lime mortar with old mughal bricks |
| 1238 | Scraping of Old white surface including stacking dismantled matreials as directed by Engineer-in-charge with in a distence of 60 mtr. (200 Feet). |
| 1239 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 1240 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) |
| 1241 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 1242 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation |
| 1243 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 1244 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 1245 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 1246 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofin compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 1247 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 1248 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (Ceiling & inner) |
| 1249 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1250 | INTERNAL ELECTRICAL WORKS BLOCK 1 |
| 1251 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1252 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1253 | Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 1254 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 1255 | (b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire |
| 1256 | (c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire |
| 1257 | (d) 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire |
| 1258 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1259 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1260 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. (a) 5/6 amps switch |
| 1261 | (b) 2 Way 5/6 amps switch |
| 1262 | (c) 15/16 amp switch |
| 1263 | (d) 3 pin 5/6 amp socket outlet |
| 1264 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 1265 | Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 1266 | Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required. (a): Up to 450mm sweep |
| 1267 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 1268 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1269 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1270 | Supply of recess/Surface mounting round 6-8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. Make: Philips or Equivalent in approved make |
| 1271 | Supply of recess/Surface mounting round 10-15 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. Make: Philips or Equivalent in approved make |
| 1272 | Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. Make: Philips or Equivalent in approved make |
| 1273 | Supply of LED Tube Light 40 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. Make: Philips or Equivalent in approved make |
| 1274 | Supply of 7W Bulkhead light fixture with specification complete as per architectural design Make: Philips or Equivalent in approved make |
| 1275 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way Double door (4 + 12) |
| 1276 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) |
| 1277 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 way, Double door TPN MCBDB |
| 1278 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 1279 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 1280 | Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. |
| 1281 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 1282 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1283 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1284 | Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 1285 | RENOVATION BLOCK 2 |
| 1286 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm |
| 1287 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 1288 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In lime mortar with old mughal bricks |
| 1289 | Scraping of Old white surface including stacking dismantled matreials as directed by Engineer-in-charge with in a distence of 60 mtr. (200 Feet). |
| 1290 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 1291 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) |
| 1292 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 1293 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation |
| 1294 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Steel Painting |
| 1295 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Wood Painting |
| 1296 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 1297 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 1298 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofin compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 1299 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 1300 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. (Ceiling & inner) |
| 1301 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1302 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1303 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed midium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1304 | Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 1305 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 1306 | (b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire |
| 1307 | (c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire |
| 1308 | (d) 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire |
| 1309 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1310 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1311 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. (a) 5/6 amps switch |
| 1312 | (b) 2 Way 5/6 amps switch |
| 1313 | (c) 15/16 amp switch |
| 1314 | (d) 3 pin 5/6 amp socket outlet |
| 1315 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 1316 | Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 1317 | Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required. (a): Up to 450mm sweep |
| 1318 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 1319 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1320 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1321 | Supply of recess/Surface mounting round 6-8 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. Make: Philips or Equivalent in approved make |
| 1322 | Supply of recess/Surface mounting round 10-15 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respec. Make: Philips or Equivalent in approved make |
| 1323 | Supply of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. Make: Philips or Equivalent in approved make |
| 1324 | Supply of LED Tube Light 40 watt Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. Make: Philips or Equivalent in approved make |
| 1325 | Supply of 7W Bulkhead light fixture with specification complete as per architectural design Make: Philips or Equivalent in approved make |
| 1326 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way Double door (4 + 12) |
| 1327 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) |
| 1328 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 way, Double door TPN MCBDB |
| 1329 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 1330 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 1331 | Suplly and burring of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) Make: As approved in U.P.P.W.D & C.P.R.I. all respects. |
| 1332 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 1333 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1334 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 1335 | Supply, Installation, Testing and Commissioning of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. |
| 1336 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.(a) up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 1337 | (b) 1.50 m to 3.00 m depthPipes 80 mm to 300 mm diameter |
| 1338 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter |
| 1339 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth 1.5 to 3.00 meter |
| 1340 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. (a) 150 mm. dia. RCC Pipes |
| 1341 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design (a) 150 mm. dia. RCC Pipes |
| 1342 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line |
| 1343 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1344 | Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line |
| 1345 | Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1346 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 1347 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) (a) 65mm nominal bore. |
| 1348 | (b) 50mm nominal bore. |
| 1349 | (c) 40mm nominal bore. |
| 1350 | (c) 25mm nominal bore. |
| 1351 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (a) 65mm nominal bore. |
| 1352 | (b) 50mm nominal bore. |
| 1353 | (c) 40mm nominal bore. |
| 1354 | (d) 25mm nominal bore. |
| 1355 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) (a) 65mm nominal bore. |
| 1356 | (b) 50mm nominal bore. |
| 1357 | (c) 40mm nominal bore. |
| 1358 | (d) 25mm nominal bore. |
| 1359 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1360 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1361 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. (a) In all kind of soil upto 1.5m depth |
| 1362 | (b) In all kind of soil upto 1.5m to 3.0m. depth |
| 1363 | (c) In all kind of soil upto 3.0m to 4.5m. depth |
| 1364 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 1365 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 1366 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1367 | Suspended floors, roofs, landings, balconies and access platform. |
| 1368 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1369 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 1370 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 1371 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 1372 | Providing & fixing 75mm dia vent pipes. |
| 1373 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 1374 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. (a) M.D. -10- Circular shape 500mm internal diameter |
| 1375 | (b) M.D. -2.5- Circular shape 450mm internal diameter |
| 1376 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 1377 | TUBE WELL |
| 1378 | Drilling of 200 mm dia bore hole. |
| 1379 | Supply of 125 mm dia MS pipe as per IS1239 |
| 1380 | Supply of 125 mm dia slotted MS pipe |
| 1381 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 1382 | Providing and packing of coarse sand / pea gravel around the pipe. |
| 1383 | Transport of boring tools other required equipements and installation at site. |
| 1384 | Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. |
| 1385 | Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) |
| 1386 | Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) |
| 1387 | Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. |
| 1388 | Lowering of 125 mm dia MS pipe in bore hole including cutting, jointing etc complete. |
| 1389 | Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. |
| 1390 | Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. |
| 1391 | Testing and development of tube well. |
| 1392 | RAIN WATER HARVESTING |
| 1393 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. (a) In all kind of soil upto 1.5m depth |
| 1394 | (b) In all kind of soil upto 1.5m to 3.0m. depth |
| 1395 | (c) In all kind of soil upto 3.0m to 4.5m. depth |
| 1396 | (d) In all kind of soil upto 4.5 m to 6.0m. depth |
| 1397 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1398 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1399 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1400 | Suspended floors, roofs, landings, balconies and access platform. |
| 1401 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1402 | 12mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) |
| 1403 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 1404 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 1405 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 1406 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 1407 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1408 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1409 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 1410 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 1411 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. (a) In all kind of soil upto 1.5m depth |
| 1412 | (b) In all kind of soil upto 1.5m to 3.0m. depth |
| 1413 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1414 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1415 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1416 | Suspended floors, roofs, landings, balconies and access platform. |
| 1417 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1418 | 12mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) |
| 1419 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 1420 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 1421 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 1422 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 1423 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. |
| 1424 | Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as per design. With FPS bricks |
| 1425 | Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: Drain 300 wide average. Depth 45 cm with R.C.C. slab |
| 1426 | PARKING |
| 1427 | Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. |
| 1428 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 1429 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 1430 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 1431 | C.C. ROAD |
| 1432 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
| 1433 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 1434 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1435 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriateproportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer |
| 1436 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. |
| 1437 | M.S. GATE |
| 1438 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. |
| 1439 | Providing and laying in cement concrete 1:4:8 (1 cement :4 fine sand :8 graded stone ballast 40 mm nominal size) and curing complete, including cost of form-work,in foundation and floors. |
| 1440 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion 1:1.5:3 in R.C.C. Footing excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200. |
| 1441 | As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-150. (a) Below plinth lvl. |
| 1442 | (b) Above plinth lvl. |
| 1443 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1444 | 12 mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. With water proofing material. (1)1 cement :6 coarse sand. |
| 1445 | Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials. |
| 1446 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1447 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 1448 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1449 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1450 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 1451 | NEW BOUNDARY WALL |
| 1452 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1453 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 1454 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C.in Plinth band |
| 1455 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 1456 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C.in Column |
| 1457 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1458 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C. work in footing |
| 1459 | TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1460 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1461 | M-150 Brick work in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : Coarse sand). |
| 1462 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1463 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 Coarse sand. 2.25 F.M. |
| 1464 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1465 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 1466 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 1467 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 1468 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 1469 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. |
| 1470 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 1471 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1472 | BADMINTON COURT |
| 1473 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer lncharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 1474 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rte required for proper completion of the work and curing complete also including cost of formwork in foundation& floors. |
| 1475 | Cost of brick worl in 1:4 cement and coarse sand for toe wall. |
| 1476 | C.C. flooring (1:2:4) |
| 1477 | Grit filling. |
| 1478 | Filling of clay I earth. |
| 1479 | C.C. Interlocking |
| 1480 | Providing & fixing of M.S. Pole |
| 1481 | LANDSCARE WORK |
| 1482 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts |
| 1483 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 1484 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm. |
| 1485 | Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately). |
| 1486 | Carrigae of manure upto 5 K.M. |
| 1487 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 1488 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 1489 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) (a) Holes 90 cm dia, and 90 cm deep |
| 1490 | (b) Holes 60 cm dia, and 60 cm deep |
| 1491 | (c) Holes 45 cm dia, and 45 cm deep. |
| 1492 | Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. |
| 1493 | Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags. |
| 1494 | Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. |
| 1495 | Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. |
| 1496 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 1497 | EXTERNAL ELECTRICAL |
| 1498 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. (The panel to be manaufactured as per detailed SLD.)STREET LIGHT PANEL (OUTDOOR TYPE) IP 65Incoming :One (1) No 63 Amp. 4P MCCB of 25KA Breaking capacity Metering :One (1) No. Sets Multifunction Meter each incomingOne (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.2 No 32 Amp. DP MCB of (10 KA)10 No. 16 Amp DP MCB. (10 KA)2 No. SPACE & SPAREPanel described as above |
| 1499 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1500 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1501 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 1502 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1503 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Up to 35 sq.mm. |
| 1504 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. |
| 1505 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1506 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm |
| 1507 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3 x 6 sq.mm, |
| 1508 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 2 X 6 sq. mm (19mm) |
| 1509 | (b) 4 X 16 sq. mm (28mm) |
| 1510 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 1511 | Supplying, installation & testing of 7.0 m high octagonal GI pole with single arm/Double arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 150mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 2Cx6 sq.mm YWY cables and 2x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. |
| 1512 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥105 <120 lm/Watt)\\"Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).\\"72 watt |
| 1513 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 1514 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply |
| 1515 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre |
| 1516 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32 mm dia |
| 1517 | COST OF SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM [UPPWD PAR E&M, Item 8] FOR MAIN BUILDING (CPWD PAR-6.8.1) |
| 1518 | Front Loading, SS body ANSI 304 grade preferred, capacity of minimum 30kg at a time, disposal at least, Fully Automatic operation. |
| 1519 | FURNISHING WORK |
| 1520 | HOSTEL BOYS(a) BEDS wooden takhat Make-Geeken/Godrej or as per UPPWD approved makes |
| 1521 | (b) STUDY TABLE Make-Geeken/Godrej or as per UPPWD approved makes |
| 1522 | (d) STUDY CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1523 | Brand handwood furniture(d) 4 SEATER DINING TABLE WITH 4 SET OF DINING CHAIRS Make-Geeken/Godrej or as per UPPWD approved makes |
| 1524 | Brand handwood furniture(e) WARDEN CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1525 | (f) WARDEN TABLE Make-Geeken/Godrej or as per UPPWD approved makes |
| 1526 | (g) VISITOR CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1527 | (h) WARDEN BED Make-Geeken/Godrej or as per UPPWD approved makes |
| 1528 | (i) ONE STORAGE CABINET Make-Geeken/Godrej or as per UPPWD approved makes |
| 1529 | GIRLS HOSTEL(a) BEDS wooden takhat Make-Geeken/Godrej or as per UPPWD approved makes |
| 1530 | (b) STUDY TABLE Make-Geeken/Godrej or as per UPPWD approved makes |
| 1531 | (d) STUDY CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1532 | Brand handwood furniture(d) 4 SEATER DINING TABLE WITH 4 SET OF DINING CHAIRS Make-Geeken/Godrej or as per UPPWD approved makes |
| 1533 | Brand handwood furniture(e) WARDEN CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1534 | (f) WARDEN TABLE Make-Geeken/Godrej or as per UPPWD approved makes |
| 1535 | (g) VISITOR CHAIR Make-Geeken/Godrej or as per UPPWD approved makes |
| 1536 | (h) WARDEN BED Make-Geeken/Godrej or as per UPPWD approved makes |
| 1537 | (i) ONE STORAGE CABINET Make-Geeken/Godrej or as per UPPWD approved makes |
| 1538 | AUDITORIUMCHAIRS |
| 1539 | LABORATORIES (5no.)(a) CHAIR |
| 1540 | (b) STUDENT STOOL |
| 1541 | (c) TABLE SHEESHAM WOOD |
| 1542 | Brand handwood furniture(d)STORAGE CABINET |
| 1543 | SEU(a) TABLES 4 SEATER |
| 1544 | (b) CHAIRS |
| 1545 | RESEARCH AND INNOVATION(a) TABLES 4 SEATER |
| 1546 | (b) CHAIRS |
| 1547 | PRINCIPAL ROOM(a) EXECUTIVE CHAIR |
| 1548 | (b) EXECUTIVE TABLE (2000X750) |
| 1549 | (c) 3 VISITOR CHAIR |
| 1550 | (d) ONE TWO SEATER SOFA |
| 1551 | (e) ONE SINGLE SEATER SOFA |
| 1552 | (f) CENTRE TABLE |
| 1553 | (g) ONE STORAGE CABINET |
| 1554 | VICE PRINCIPAL ROOM(a) EXECUTIVE CHAIR |
| 1555 | (b) EXECUTIVE TABLE (2000X750) |
| 1556 | (c) 3 VISITOR CHAIR |
| 1557 | (d) ONE STORAGE CABINET |
| 1558 | FACULTY ROOM(a) EXECUTIVE CHAIR |
| 1559 | (b) EXECUTIVE TABLE (1500X750) |
| 1560 | (c) 2 VISITOR CHAIR |
| 1561 | (d) ONE STORAGE CABINET |
| 1562 | ACADEMIC CLASSROOM(a) CHAIR |
| 1563 | (b) TABLE |
| 1564 | (c) STOOLS (gst 823 geeken) |
| 1565 | (d) WHITE BOARD |
| 1566 | AUDIO VIDEO SYSTEM |
| 1567 | SITC of Wall mount Speaker: Power Tap: 10W/20W/40W/OFF-8ohm,Power at 8ohm, 60W;Peak Power: 80W,SPL@1M: 94±3db, Max SPL@1M: 112db, Frequency Response: 65-20KHz,Dispersion Angle: Vertical : 80° and Horizontal:100° (1KHz),Enclosure Material : PP Enclosure and 360-degree metal mounting bracket, Speaker 6.5” weatherproof woofer and 1” silk tweeter. |
| 1568 | SITC of Amplifier: Power Output 550W Max., 500W RMS at 10% THD, 440W RMS at 5% THD, Output Regulation 2 dB, no load to full load at 1kHz, Input Channels 7 X Mic. 0.65mV/4.7k Ohms , 2 X Aux 100mV/470k Ohms, Frequency Response 50-15,000Hz ±3dB, Signal to Noise Ratio 60dB , Tone Controls Bass ±10dB at 100Hz, Treble±10dB at 10KHz, Outputs Line: 200mV/600 Ohms, 1V/1k Ohms, Speaker Output 4 Ohms, 8 Ohms & 100V, Digital Player MP3 Player with USB, SD Card & Bluetooth, Power Supply AC: 220-240V 50/60Hz , DC: 12V, Power Consumption : AC : 250VA DC : 4A, Power Consumption AC : 250VA DC : 4A, Consist of USB Pen drive Port, SD Card Plug and Play, Compatible with Radio & Bluetooth, EQ & Recording, 7 Channels Microphone Inputs, 2 Channels Aux Inputs, 1 Channel Line Output. 100V Constant Voltage Output and 4Ω\ 8 Ω \16 Ω Resistance Output. |
| 1569 | Supply Installation testing & commissioning of 12 channel mixer with 8 mic/line, 2 stereo line, 4 aux, 2 subgroup, graphic EQ, DSP effects, mp3, BT, mp3 recording |
| 1570 | SITC of Handheld Combo Variable Frequency: High quality UHF band frequency dual Wireless Microphone System; 80 Selectable UHF Channels. UHF Operating Frequency Range: 583–683 MHZ; Back Light Display for Frequency Identification ;Individual channel output with level control & mix output ; Two microphones can be used at the same time; Easy setup of the system with Infra-Red; Can cover distance upto 150 mtr. (between Receiver and Microphone); Separate LCD Display for channels; High quality capsule in Handheld Mics; XLR Balanced and unbalanced out; Flight Case |
| 1571 | Supply Installation Testing & Commisionning of Laser Projector,WUXGA resolution (1,920x1,200) , 7000 ANSI Lumenns,Contrast Ratio 3,000,000:1, Zoom , Focus &Lens Shift , (Make - Sony , Epson , LG ) |
| 1572 | Supply, Installation testing & commissioning of 180\\" diagonal motorized screen with aspect ratio of 16:9, complete with all standard accessories as per the tender specification (Make - Liberty , Suvira , Prima ) |
| 1573 | Supply Installation Testing & Commisionning of Mount (Make - Liberty , Suvira , Prima ) |
| 1574 | Supply Installation testing & commissioning of RX - TX 40 mtr Range |
| 1575 | Supply Installation Testing & Commisionning of HDMI PLATE |
| 1576 | Supply Installation Testing & Commisionning of HDMI Switch (2x1) (Make - Aten , Milestone , Kramer ) |
| 1577 | Supply Installation Testing & Commisionning of Audio Embader (Make - Aten , Milestone , Kramer ) |
| 1578 | Supply Installation testing & commissioning of Speaker Wire 16 awg -1.5 MM X 2 CORE |
| 1579 | Supply Installation Testing & Commisionning of 18U Equipment for backend system for Equipment Rack (Make - Comrack , Valrack , Legrand ) |
| 1580 | Supply Installation testing & commissioning of Digital cable & connectors |
| 1581 | CCTV SYSTEM |
| 1582 | S/I/T/C of CCTV Camera dome 4 MP Make-HikvisionDS-2CD3151G0-I |
| 1583 | S/I/T/C of CCTV Camera Bullet 5 MP Make-HikvisionDS-2CD3151G0- |
| 1584 | S/I/T/C of CCTV NVR |
| 1585 | S/I/T/C of CCTV Back Box Make-Hikvision |
| 1586 | S/I/T/C of NVR Surveillance HDD 8 TB for 30 days CCTV Backup Make-W/D |
| 1587 | S/I/T/C 0f 12 Port POE Switch Make Dlink/DGS-F121028P/ME |
| 1588 | S/I/T/C 17 U Rack Make Netrack |
| 1589 | S/I/T/C Cat 6 Cable Make- Dlink for complete works |
| 1590 | S/I/T/C 25 mm Conduit Make- Branded for complete works |
| 1591 | Cat 6 Networking Cable For Modern Grey for complete works |
| 1592 | S/I/T/CRJ 45 Connector for complete works |
| 1593 | S/I/T/C 1 KVA UPS with inbuilt Battery Make-Eaton |
| 1594 | S/I/T/C of 32'' TV Make-LG/Samsung |
| 1595 | SMART CLASS ROOM |
| 1596 | SOUND RE-INFORCEMENT SYSTEMSITC of Amplifier + Two Wall Speaker + Wireless Micsystem |
| 1597 | VIDEO & PROJECTION SYSTEMSITC of Interactive Display 65 Stunning 4K UHDresolution redefines clarity • 20 Touch points Highaccuracy touch screen. • support 1 point 2mm precision writing and 6 points 3mm simultaneous writing • All- channel annotating, • built-in Android Operating System• Public USB port auto switch • Smart sidebar menu |
| 1598 | CABLE AND CONNECTORSSITC of HDMI Cable. And connector |
| 1599 | GST Extra as applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail