| Sl. No. | Item Description |
| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 min width as well as10 sqm on plan including disposal of excavated earth, leadupto50 meter and lift upto 1.5m, as directed by Engineer-in-Charge.All kinds of soil: |
| 2 | Deduct for not rolling with power roller of minimum 8tonnes for banking excavated Earth in layers not exceeding 20cm in depth. |
| 3 | Deduct for not watering the excavated earth for banking. |
| 4 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5m in widthaswell as10m2 on plan)includingdisposal ofexcavated earth lead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge. All kinds of soil: |
| 5 | All kinds of soil |
| 6 | Earth work in bulk excavation bymechanical means(hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50meters and lift upto 1.5 m,as directed by Engineer-in-Charge. |
| 7 | All kinds of soil |
| 8 | OrdinaryRock |
| 9 | Earth workin excavation bymanualmeans intrenchesfor foundations, drains,pipes, cablesetc. (not exceeding1.5m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms liftupto 1.5 m, including getting outexcavated earth and disposalof surplus excavated earth as directed: All Kinds of Soil |
| 10 | Rate for a lead upto 1 meter from cutting edge |
| 11 | Rate for a lead upto 25 meter from cutting edge |
| 12 | Rate for a lead upto 50 meter from cutting edge |
| 13 | Extra for every additional lift of 1.5 morpart there of in excavation /banking excavated or stacked material : |
| 14 | All kinds of soil : |
| 15 | Ordinary or hard rock |
| 16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating eachdeposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 17 | Excavating,supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches,plinth,sides of foundation etc.complete. |
| 18 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto50m and lift upto1.5min-All kinds of soil. |
| 19 | Supplying and filling in plinth with fines and under floors including, watering, ramming,consolidating and dressing complete. |
| 20 | Clearing grass and removal of the rubbish upto a distance of 50m outside the periphery of the area cleared. |
| 21 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 22 | Beyond 30 cm girth upto and including 60cm girth |
| 23 | Beyond 60cm girth upto and including 120cm girth. |
| 24 | Beyond 120cm girth upto and including 240cm girth. |
| 25 | Above 240cm girth |
| 26 | Extra for levelling & neatly dressing of disposeds oil completely as directed by Engineer-in-charge. |
| 27 | Pumping outwatercaused by springs, tidal or river seepage,broken water mains or drains and the like. |
| 28 | Removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions,all inclusive. |
| 29 | Providing and laying dry stone soling in the Trenches/ feilds duly hand packed in level including ramming with iron rammers for foundation including all carriages up to 15 kms, Loading and unloading. |
| 30 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering.All work upto plinth level with: |
| 31 | 1:1½:3 (1cement: 1½coarsesand: 3gradedstoneaggregate 20mm nominal size) |
| 32 | 1:2:4 (1cement :2coarsesand: 4gradedstone aggregate 20mm nominal size) |
| 33 | 1:2:4(1cement: 2coarses and: 4graded stone aggregate 40mm nominal size) |
| 34 | 1:3:6 (1cement: 3coarses and: 6graded stone aggregate 20mm nominal size) |
| 35 | 1:3:6 (1cement: 3coarses and: 6graded stone aggregate 40mm nominal size) |
| 36 | 1:4:8 (1cement: 4coarses and: 8graded stone aggregate 40mm nominal size) |
| 37 | 1:5:10 (1cement: 5coarses and: 10graded stone aggregate 40mm nominal size) |
| 38 | Providing and laying cement concrete in retaining walls,return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses ,parapets, coping,bedblocks,anchors blocks,plainwindowsills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. |
| 39 | 1:1½:3 (1cement: 1½coarse sand: 3graded stone aggregate 20mm nominal size) |
| 40 | 1:2:4 (1cement: 2coarses and: 4graded stone aggregate 20mm nominal size) |
| 41 | 1:3:6 (1cement: 3coarses and: 6graded stone aggregate 20mm nominal size) |
| 42 | 1:3:6 (1cement: 3coarses and: 6graded stone aggregate 40mm nominal size) |
| 43 | 1:5:10 (1cement 5coarses and: 10graded stone aggregate 40mm nominal size) |
| 44 | 1:5:10 (1cement: 5coarses and: 10graded brick aggregate 40mm nominal size |
| 45 | Providing & laying damp-proof Course 40mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete |
| 46 | Providing and layingdamp-proof Course 50mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 47 | Providing and mixing waterproofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1kg of waterproofing material in 50kg of cement) |
| 48 | Applying a coat of residual petroleum bitumen of gradeVG-10 of approved quality using1.7 kg per square meter on damp proof courses after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 49 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal sizewell rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 50 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. |
| 51 | 1:1½:3 (1cement: 1½coarses and: 3graded stone aggregate 20mm nominal size) |
| 52 | 1:2:4 (1cement: 2coarses and: 4graded stone aggregate 20mm nominal size) |
| 53 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and strutsuptofloor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1cement: 1½coarsesand: 3graded stone aggregate 20mm nominal size). |
| 54 | Reinforced cement concrete workin beams, suspended floors, roofs havingslope upto15°, landings, balconies, shelves, chajjas,lintels, bands, plain windowsills, staircasesandspiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with --- 1:1½:3 (1cement: 1½coarses and: 3graded stone aggregate 20mm nominal size) |
| 55 | Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with---1:1½:3 (1cement: 1½coarses and: 3graded stone aggregate 20mm nominal size) |
| 56 | Centering and shuttering including strutting ,propping etc.and removal of form for: |
| 57 | Foundations, footings, bases of columnsetc.for mass concrete. |
| 58 | Walls (anythickness) including attached pilasters, buttresses, plinth and string coursesetc. |
| 59 | Suspended floors ,roofs ,landings ,balconies and access platforms. |
| 60 | Shelves(cast-in-situ) |
| 61 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 62 | Columns, pillars, piers, abutments,posts and struts. |
| 63 | Stairs (excluding landings) except spiral stair cases. |
| 64 | Spiral stair cases (including landings) |
| 65 | Extra for shuttering in circular work (20% of respective centering and Shuttering items) |
| 66 | Smalll intels not exceeding1.5m clears pan, mouldings as in cornices,window sills, string courses, bands, copings, bed plates, anchor blocks and the like. |
| 67 | Edges of slabs and breaks in floors and walls Under 20cm wide |
| 68 | Edges of slabs and breaks in floors and walls Above 20cm wide |
| 69 | Steel reinforcementfor R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level and above Plinth level. |
| 70 | Mild steel and medium tensile steel bars |
| 71 | Hard drawn steel wire |
| 72 | Cold twisted bars |
| 73 | Hot rolled deformed bars |
| 74 | Hard drawn steel wire fabric |
| 75 | Thermo-Mechanically Treated bars of gradeFe-500D or more. |
| 76 | Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) including curing. |
| 77 | Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement: 2 coarse sand) including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landingsand steps including subsequent removal and cleaning of the same. |
| 78 | Extra for laying reinforced cement concrete in or under foul position. |
| 79 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: |
| 80 | Cement mortar 1:4 (1cement: 4coarse sand) |
| 81 | Cement mortar 1:6 (1cement: 6coarse sand) |
| 82 | Extra for brick work with common burnt clay bricks /cement concrete bricks in superstructure above plinth level upto floor five level |
| 83 | Extra for brick work in:Square or rectangular pillars |
| 84 | Extra for brick work with bricks of class designation 75 curved on plan upto a meanradius not exceeding 6 meters. |
| 85 | Extra for cutting or chamfering of bricks to required shape in masonry work. |
| 86 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in : |
| 87 | Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 88 | Cement mortar 1:4 ( 1 cement : 4 coarse sand |
| 89 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 90 | Extra for half Brick masonry in superstructure, above floor V level for every four floorsor part thereof by mechanical means. |
| 91 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every thirdcourse of half brick masonry. |
| 92 | Labour charges for Brickworkwithcommonburntclay(non-modular)bricksofclassdesignation7.5in foundation / plinth and superstructure includingcuringin Cementmortar1:4& 1:6 (1cement:4 or 6coarse sand ): |
| 93 | Random Rubble masonry with hard stone in foundation and plinthincluding leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Quarry Stone (a-Cement mortar 1:6 (1Cement: 6coarse sand)) |
| 94 | Random Rubble masonry with hard stone in foundation and plinthincluding leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Nallah Stone (b-Cement mortar 1:6 (1Cement :6coarse sand)) |
| 95 | Random Rubble masonry with hard stone in superstructure above plinthincluding leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Quarry Stone (a-Cement mortar 1:6 (1Cement :6 coarse sand)) |
| 96 | Random Rubble masonry with hard stone in superstructure above plinthincluding leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Nallah Stone (b-Cement mortar 1:6 (1Cement :6coarse sand)) |
| 97 | Dryrandomrubblemasonrywithhardstoneinfoundationandplinth: Withbondstone.Withoutbondstone Quarry Stone |
| 98 | Dryrandomrubblemasonrywithhardstoneinfoundationandplinth: Withbondstone Nallah Stone |
| 99 | Dryrandomrubblemasonrywithhardstoneinfoundationandplinth: Withoutbondstone Nallah Stone |
| 100 | Coursed Rubble Masonry with hard stone in foundation and plinth and curing complete with: 7.6.1 Cement mortar1:6(1Cement :6coarseSand)- 1stSort |
| 101 | Coursed Rubble Masonry with hard stone in foundation and plinth and curing complete with Cement mortar 1:6 (1Cement: 6coarse Sand)- 2ndSort |
| 102 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing.One face dressed -Fine chisel dressed. |
| 103 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing.One face dressed -Rough chisel dressed |
| 104 | Marble work gang sawcut (polished and machinecut) of thickness 16 mm for wall lining (veneer work), backingfilledwitha grout of12mmthickaveragein cement mortar1:3(1 cement: 3coarsesand), includingpointingwith white cement mortar 1:2(1white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Raj Nagar plain white marble/Udaipur green marble/zebra black marble. |
| 105 | (Area of slab upto 0.5sqm) |
| 106 | (Area of slab over 0.5sqm) |
| 107 | Providing and fixing gang sawcut, mirror polished, premoulded and prepolished,machine cut for kitchen platforms,vanity counters,windowsills,facias and similar locations,of required size, approved shade,colour and texture laid over 20mm thick base cement mortar 1:4 (1cement: 4coarses and),joints treated with white cement, mixed with matching pigment,epoxy touchups,including rubbing,curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels – |
| 108 | Raj Nagar plain white marble/Udaipur green marble/zebra black marble: 16 MM |
| 109 | (Area of slab upto 0.5sqm) |
| 110 | (Area of slab over0.5 sqm) |
| 111 | Granite of any colour or shade -16 MM |
| 112 | (Area of slab upto 0.5sqm) |
| 113 | (Area of slab over 0.5sqm) |
| 114 | Granite of any colour or shade -18 MM |
| 115 | (Area of slab upto 0.5sqm) |
| 116 | (Area of slab over 0.5sqm) |
| 117 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 118 | MarbleWork |
| 119 | GraniteWork |
| 120 | Extra for fixing marble / granite stone over and above corresponding basic item, infacia and drops of width upto 150mm with epoxy resin based adhesive including cleaning etc complete. |
| 121 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 122 | Mirror polishing on marble work/granite/stone work where ever required to give high gloss finish complete. |
| 123 | Stone tile (polished) work for walllining over 12mm thick bed of cement mortar 1:3 (1 stone tile (polished) work for walllining over 12mm thick bed of cement mortar 1:3 (1 cement with curing complete. |
| 124 | 8mm thick - Raj Nagar white marble/Udaipur green marble/zebra black marble |
| 125 | 8mm thick - Granite of any colour and shade |
| 126 | 18mm thick Doongri Adanaga marble |
| 127 | Wall lining butch work upto10mheight with Dholpur stone40mm thickrough facingon the exposed surface with stone strips of minimum length 300mm and required width includingembeddingeverytenth layer andbottommostlayerin masonryor concreteafter making necessary chases of size 75 x 75mm and by providing layer of75 thick strips including 12mm thick bed of cement mortar 1:3 (1cement: 3coarse sand) including ruled pointing in cement mortar 1: 2 (1 white cement : 2 stone dust) with an ad mixture of pigment to match the shade of the stone and curing complete as per the directions of engineer-in-charge. |
| 128 | Providing and fixing plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface- Second class Teak Wood |
| 129 | 12mm thick |
| 130 | 20mm thick |
| 131 | 25mmthick |
| 132 | 40mm thick |
| 133 | Providing and fixing plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface- Second class Deodar Wood |
| 134 | 12mm thick |
| 135 | 20mm thick |
| 136 | 25mmthick |
| 137 | 40mm thick |
| 138 | Providing and fixingin wall lining of specified medium densityboard, pre-laminated one side decorative lamination other side balancing lamination Grade I, exterior grade, with necessary fixing arrangement and screws etc. complete.:-Flatpressed 3layer particle board or graded wood particle boardgrade-Itype-II, IS: 12823 marked including primer coat on unexposed surfaces |
| 139 | 12mm thick |
| 140 | 18mm thick |
| 141 | 25mm thick |
| 142 | Providing and fixingin wall lining of specified medium densityboard, pre- laminated one side decorative lamination other side balancing lamination Grade I, exterior grade, with necessary fixing arrangement and screws etc.complete :- MDF board IS:1998 marked. |
| 143 | 12mm thick |
| 144 | 18mm thick |
| 145 | 25mm thick |
| 146 | Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete: |
| 147 | Second Class Teak Wood |
| 148 | Second Class Kail Wood |
| 149 | Kiln seasoned and chemically treated hollock wood |
| 150 | Providing and fixing plain panelling with skirting chair rails, and cornice with necessary screws, priming coat on unexposed surface etc., complete.:-Second class Teak Wood |
| 151 | 12mmthick |
| 152 | 20mmthick |
| 153 | 25mmthick |
| 154 | 40mmthick |
| 155 | Providing and fixing plain panelling with skirting chair rails, and cornice with necessary screws, priming coat on unexposed surface etc., complete.:-Second class Deodar Wood |
| 156 | 12mmthick |
| 157 | 20mmthick |
| 158 | 25mmthick |
| 159 | 40mmthick |
| 160 | Providing and fixing plywood 4mm thick one side decorative veneer conforming toIS: 1328(type1),for plain lining/cladding with necessary screws, including priming coat on unexposed surface with. Decorative veneer facings of approved manufactures |
| 161 | Providing and fixing 4mm thick coir veneer board ISI marked IS:14842 plain lining with necessary screws,priming coat on unexposed surface etc.complete |
| 162 | Providing and fixing skirting of specified board pre laminated with (one side decorative and other side balancing lamination), medium density Grade I exterior grade, with necessary fixing arrangements and screws including drilling necessary holes for rawlPlugs etc complete. |
| 163 | Flatpressed 3layer particle boardor graded wood particle board grade-Itype-II, IS:12823 marked including priming coat on unexposed surfaces- 18 mm . |
| 164 | Flatpressed 3layer particle boardor graded wood particle board grade-Itype-II,IS:12823 marked including priming coat on unexposed surfaces- 25 mm. |
| 165 | Providing and fixing skirting of specified board pre laminated with (one side decorative and other side balancing lamination), medium density Grade I exterior grade, with necessary fixing arrangements and screws including drilling necessary holes for rawlPlugs etc complete. |
| 166 | MDF board conforming to IS:14587 edges to be sealed with PVC edge bending tape 2.00mm thick of approved brand.-18 mm |
| 167 | MDF board conforming to IS:14587 edges to be sealed with PVC edge bending tape 2.00mm thick of approved brand.-25 mm |
| 168 | CERAMICGLAZEDTILESProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting,risersof stepsand dados over 12mmthick bed of cementmortar 1:3 ( 1 cement : 3 coarse sand) and jointing with greycement slurry@ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 169 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class teak wood |
| 170 | First class teak wood |
| 171 | Second class teak wood |
| 172 | First class deodar wood |
| 173 | Second class deodar wood |
| 174 | First class kail wood |
| 175 | Second class kail wood |
| 176 | Sal wood |
| 177 | Providinglaminated veneer lumber conformingtoIS. 14616andTAD-15: 2001 (part B) in factory made frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugsor with dash fasteners shall be paid for separately). |
| 178 | Providing hoisting and fixing trusses/purlins/rafters/posts/post-platesorlike components including cost ofscrews etc. complete:A) SecondclassKailwood |
| 179 | A) SecondclassKailwood |
| 180 | B) FirstclassBudloo/Firwood |
| 181 | Providing wood work in frames of false ceiling, partitions etc.sawn and fixed in position:- Salwood |
| 182 | Providing wood work in frames of false ceiling, partitions etc.sawn and fixed in position:- Budloo/Firwood |
| 183 | Providing wood work in frames of false ceiling, partitionsetc.sawn and fixed in position:- Kiln seasoned and chemically treated hollockwood |
| 184 | Extra for circular works,such as in frames of fan light |
| 185 | Second class teak wood |
| 186 | First class deodar wood |
| 187 | Second class deodar wood |
| 188 | First class kail wood |
| 189 | Second class kail wood |
| 190 | Salwood |
| 191 | Kiln seasoned and chemically treated hollock wood |
| 192 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws,excluding panelling which will be paid for separately,all complete as per direction of Engineer-in-charge.(Note:-Butt hinges and necessary screws shall be paid separately).-35 mm THICK |
| 193 | Secondclassteakwood |
| 194 | Firstclassdeodar wood |
| 195 | Secondclassdeodar wood |
| 196 | Firstclasskailwood |
| 197 | Secondclasskailwood |
| 198 | Kiln seasoned and chemically treated hollock wood |
| 199 | Kiln seasoned selected planks of sheesham wood |
| 200 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws,excluding panelling which will be paid for separately,all complete as per direction of Engineer-in-charge.(Note:-Butt hinges and necessary screws shall be paid separately).-30 mm THICK |
| 201 | Secondclassteakwood |
| 202 | Firstclassdeodar wood |
| 203 | Secondclassdeodar wood |
| 204 | Firstclasskailwood |
| 205 | Secondclasskailwood |
| 206 | Kiln seasoned and chemically treated hollock wood |
| 207 | Kiln seasoned selected planks of sheesham wood |
| 208 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :(Note:-Butt hinges and necessary screws shall be paid separately) |
| 209 | 12 mm thick plain grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848: |
| 210 | 12 mm thick pre-laminatedparticle board (decorative lamination on both sides)grade-I,mediumdensityflat pressedthreelayer particleboardFPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and pre-laminated conforming to IS: 12823, Grade-I, Type-II marked : |
| 211 | 12mm thickpre-laminated particle board (decorative lamination on one side and other side balancing lamination) grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT- I, IS: 3087 marked, bonded with BWP type syntheticresin adhesive asper IS: 848 and pre-laminatedconformingtoIS:12823,Grade-I,Type-IImarked: |
| 212 | Labour Charges for hoisting and fixing trusses/ purlins/ rafters/posts/post- plates or like components including cost ofscrews etc. complete in all sorts of timber. |
| 213 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windowsto be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick(Area of opening for panel inserts excluding portion inside grooves or rebates |
| 214 | SecondClassteak wood |
| 215 | FirstClassdeodar wood |
| 216 | SecondClassdeodar wood. |
| 217 | FirstClasskail wood |
| 218 | SecondClasskail wood |
| 219 | Kilnseasoned&chemicallytreatedhollock wood |
| 220 | Ply wood 5 ply, 9 mm thick -Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type |
| 221 | Decorative ply wood one side decorative veneer and commercial veneer on other face (type 1) conforming IS 1328 BWR type |
| 222 | Commercial ply on both sides |
| 223 | Plywood 7 ply, 9mm thick- Decorative plywood one side decorative veneer and commercial veneer on other face (Type -I) conforming to IS 1328 BWR type |
| 224 | Particle Boad 12mm thick-Plain particleboardflatpressed, 3layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 225 | Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sidesConformingto IS : 3097 grade 1 |
| 226 | Pre-laminated particle board withdecorative laminationon oneside and balancing lamination on other side, Grade I, Type II IS : 12823 marked |
| 227 | Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 12823 marked |
| 228 | MDF boad 12 mm thick -Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 14587 |
| 229 | 12mm thick Coir Veneer Board (conformingtoIS: 14842) |
| 230 | Float glass panes 4mm thick glass pane (weighing not less than 10 kg/sqm).2 |
| 231 | 5.0mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 232 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm diawireand 1.4 mm wide aperture with matching wood beading |
| 233 | 12mm thick Marine plywood conforming to IS: 710 |
| 234 | 12 mm thick Fire retardant plywood conforming to IS: 5509 |
| 235 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture1.4mm in both directions all complete. With Galvanized M.S.Wire gauge with wire of dia 0.63mm. With 2nd class teak wood beading 62x19mm |
| 236 | With12mmmildsteelUbeading |
| 237 | With stainless steel grade 304 wire gauge with wire of dia 0.50 mm With 2nd class teak wood beading 62x19mm |
| 238 | With12mmmildsteelUbeading |
| 239 | Providing and fixing glazed shutters for doors,windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws.-35 mm thick Second class teak wood |
| 240 | Firstclassdeodar wood |
| 241 | Secondclassdeodar wood |
| 242 | Firstclasskailwood |
| 243 | SecondclassKailwood |
| 244 | Kiln seasoned and chemically treated hollock wood |
| 245 | Kiln seasoned and selected planks of sheesham wood. |
| 246 | Providing and fixing glazed shutters for doors,windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws.- 30 mm thick |
| 247 | Second class teakwood |
| 248 | First class deodar wood |
| 249 | Second class deodar wood |
| 250 | First class kail wood |
| 251 | Second class Kail wood |
| 252 | Kiln seasoned and chemically treated hollock wood |
| 253 | Kiln seasoned and selected planks of sheesham wood. |
| 254 | Providing and fixing30 mm thickfactorymadelaminatedveneer lumber glazed shutter conformingto IS:14616andTADS 15 :2001 (PartB), using 4mmthick float glass panes for doors, windows and clerestory windows fixing with ISI marked butt hinges of required sizewith necessary screws as per directions of Engineer-in-charge.(Note:-Butt hinges and necessary screws shall be paid separately) |
| 255 | Extra for providingheavysheet float glass panes instead of ordinaryfloat glass in glazed doors, windows and clerestorywindow shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 5.0mm thick instead of 4 mm thick |
| 256 | Extra for providing frosted glass panes 4 mm thick instead of ordinary floatglass panes 4 mm thick in doors, windows and clerestory window shutters.(Area of opening for glass panes excluding portion inside rebate shall be measured) |
| 257 | Deduct for providing pin headed glass panes instead of ordinary float glass panes 4mm thick indoors,windows and clerestory window shutters.(Area of opening for glass panes excluding portion inside rebate shall b emeasured). |
| 258 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws, (Shutter area to be measured). |
| 259 | Deduct for not providing hinges indoors, windows and clerestory windows shutters for 2nd class teak wood and other class of wood shutters with: |
| 260 | Stainless steel butt hinges with Stainless Steel Screws: |
| 261 | ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws |
| 262 | Providing and fixing 25 mm thick shutters for cupboard etc, including ISI marked M.S. pressed butt hinges bright finished ofrequiredsize with necessary screws Panelled or paneled and glazed shutters Second class teak wood |
| 263 | Firstclassdeodarwood |
| 264 | Secondclassdeodarwood |
| 265 | Firstclasskailwood |
| 266 | Secondclasskailwood |
| 267 | Glazed Shutters |
| 268 | Secondclassteakwood |
| 269 | Firstclassdeodarwood |
| 270 | Secondclassdeodarwood |
| 271 | Firstclasskailwood |
| 272 | Secondclasskailwood |
| 273 | MDF board shutters including ISI marked nickel plated bright finished M.S.piano hinges IS:3818 marked with necessary screws complete: Pre-laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked one side decorative and other side balancing lamination, edgestobesealedwithPVCedgebendingtape2.00mmthickofapproved brand. |
| 274 | Extra for providing ISI marked Nickel plated bright finished M.S. Pianohinges IS: 3818 instead of IS marked M.S. pressed butt hinges bright finished of required size with necessary screws for cupboard shutters:(shutter area to bemeasured). |
| 275 | Extra for providing ISI marked Anodized Aluminium butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws for cupboard shutters. (Shutter area to be measured). |
| 276 | Providing and fixing specifiedboard medium density exterior grade (Grade I) to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) |
| 277 | Flat pressed 3 layer particle board or graded wood particle board IS:3087 |
| 278 | Pre-laminated with decorative lamination on both sides MDF board conforming to IS:14587. |
| 279 | Providing and fixing specified pre-laminated medium density board with one side decorative and other side balancing lamination Grade I (exterior grade)in shelves with screws and fittings wherever required, (fittings to be paid separately). |
| 280 | Flat pressed 3 layer particle board or graded wood particle boardgrade- I type-II conforming to IS” 3087 edges to be painted with polyurethane primer. |
| 281 | MDF board conforming to IS:14587 edges to be sealed with PVC edge bending tape 2.00mm thick of approved brand. |
| 282 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (PartI)decorativetype, coreofblockboardconstruction withframeof1st class hard wood and well matched teak 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 283 | With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 284 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws |
| 285 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters |
| 286 | With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 287 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws |
| 288 | Extra for providing and fixing flush doors with decorative veneering instead of non-decorative ISI marked flush door shutters conforming to ISI: 2202 (Part-I) On one side only |
| 289 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 290 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge |
| 291 | Second class teak wood |
| 292 | First class deodar wood |
| 293 | Second class deodar wood |
| 294 | First class kail wood |
| 295 | Second class kail wood |
| 296 | Kiln seasoned and chemically treated hollock wood |
| 297 | Kiln seasoned and selected planks of sheesham wood |
| 298 | Extra for using stainless steel grade 304 wire gauge with wire of dia. 0.5 mm instead of Galvanized M.S. Wire gauge with wire of dia. 0.63 mm for doors, windows and clerestory windows with necessary screws: (shutter area to be measured) |
| 299 | Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS 14616 and as per TADS 15:2001( Part B) using galvanized wire gauze with average width of aperture 1.4mm in both direction with wire of dia 0.63mm as per IS: 1568 for doors, windows and clerestory windows, including ISI marked MS pressed butt hinges bright finished of required size with necessary screws, as per direction of engineer in charge |
| 300 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: |
| 301 | 2nd class teak wood |
| 302 | 50 x 12 mm |
| 303 | 50x20mm |
| 304 | 2nd class deodar wood |
| 305 | 50 x 12 mm |
| 306 | 50 x 20mm |
| 307 | 2nd Class Kail wood |
| 308 | 50 x 12 mm |
| 309 | 50 x 20mm |
| 310 | Budloo / Fir wood |
| 311 | 50 x 12 mm |
| 312 | 50 x 20mm |
| 313 | Kiln seasoned and chemically treated hollock wood |
| 314 | 50 x 12 mm |
| 315 | 50 x 20mm |
| 316 | Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with |
| 317 | Second class teak wood |
| 318 | First class deodar wood. |
| 319 | Second class deodar wood. |
| 320 | First class kail wood. |
| 321 | 2nd class kail wood |
| 322 | Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked including top cover of 6mm commercial ply wood conforming to IS :303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100mm x 40mmx40 mm on both inner side of pelmet and rawl plugs 75mm long etc. all complete. |
| 323 | Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842-2000, including top cover of 6mm coir veneer board, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100mm x 40mmx40 mm on both inner side of pelmet and rawl plugs 75mm long etc. all complete. |
| 324 | Extra for using veneered particle board conforming to IS: 3097 Grade I, in item of pelmet 18mm thick 150mm wide |
| 325 | Non decorative Veneer on both sides |
| 326 | Particle board with decorative veneering on both sides. |
| 327 | Providing and fixing teak wood lipping of size 25x3mm in pelme |
| 328 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete |
| 329 | 12mm dia |
| 330 | 20mm dia |
| 331 | 25mm dia |
| 332 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets |
| 333 | 20mm dia (heavy type) |
| 334 | 25mm dia (heavy type) |
| 335 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 336 | Fixed to steel windows by welding |
| 337 | Fixed to openings / wooden frames with rawl plugs screws etc |
| 338 | Providing and fixing expanded metal 20x60mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62x19 mm beading of 2ndclass teak wood and priming coat with approved steel primer all complete. |
| 339 | Providing and fixing hard drawn steel wire fabric 75x25mm mesh of weight not less than 7.75 kg/sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete.. |
| 340 | Deduct for fixing 75x25mm hard drawn steel wire fabric of weight not less than 7.75 kg. persqm in panelled and glazed door and window shutter insteadof glass sheet 4mm thick. |
| 341 | Providing 40x5mm flat iron holdfast 40cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 342 | Providing beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : |
| 343 | Salwood |
| 344 | Second class deodar wood |
| 345 | Second class kailw ood |
| 346 | Hollock wood |
| 347 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : |
| 348 | 125x65x2.12mm |
| 349 | 100x58x1.90mm |
| 350 | 75x47x1.70mm |
| 351 | 50x37x1.50mm |
| 352 | Providing and fixing IS:1341 marked M.S.heavy weight-Butt Hinges with necessary screws etc.,complete: |
| 353 | 125x90x4.00mm |
| 354 | 100x75x3.50mm |
| 355 | 75x60x3.10mm |
| 356 | 50x40x2.50mm |
| 357 | Providing an dfixing ISI marked oxidized M.S .pressed butt hinges with necessary screws etc. complete: |
| 358 | 125x65x2.12mm |
| 359 | 100x58x1.90mm |
| 360 | 75x47x1.70mm |
| 361 | 50x37x1.50mm |
| 362 | Providing and fixing ISI marked oxidized M.S .pressed parliamentary hinges with necessary screws etc. complete: |
| 363 | 150x125x27x2.80mm |
| 364 | 125x125x27x2.80mm |
| 365 | 100x125x27x2.80mm |
| 366 | 75x100x20x2.24mm |
| 367 | Providing and fixing ISI marked oxidized M.S. spring hinges with necessary screws etc. complete: |
| 368 | SingleActingSpringhinge |
| 369 | 150mm |
| 370 | 2125mm |
| 371 | 3100mm |
| 372 | DoubleActingSpringhinge |
| 373 | 1150mm |
| 374 | .2125mm |
| 375 | 3100mm |
| 376 | Providing M.S.PianohingesISImarkedIS:3818finished with nickelplating and fixing with necessary screws etc., complete. |
| 377 | Over all width 35mm |
| 378 | Over all width 50mm |
| 379 | Over all width 65mm |
| 380 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : |
| 381 | 300x16mm |
| 382 | 250x16mm |
| 383 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. |
| 384 | 250x10mm |
| 385 | 200x10mm |
| 386 | 150x10mm |
| 387 | 100x10mm |
| 388 | Providing and fixing ISI marked 85 mm x 42 mm oxidized M.S. pull bolt lock conforming to IS:7534 with necessary screws, bolts, nut and washers etc. complete. |
| 389 | Providing and fixing ISI marked oxidized M.S. door latches conforming to IS :5930 with screws etc. complete : |
| 390 | 300x20x6mm |
| 391 | 250x20x6mm |
| 392 | Providing and fixing ISI marked oxidized M.S.handles conforming to IS:4992 with necessary screws etc. complete : |
| 393 | 125mm |
| 394 | 100mm |
| 395 | Providing and fixing oxidized M.S. hasp and staple (Safety type) conforming to IS : 363 with necessary screws etc. complete : |
| 396 | 150mm |
| 397 | 115mm |
| 398 | Providing and fixing oxidized M.S.casement stays (straight peg type) with necessary screws etc. complete. |
| 399 | 300 mm weighing not less than 200 gms. |
| 400 | 250mmweighingnot lessthan150gms. |
| 401 | 200mmweighingnot lessthan120gms. |
| 402 | Providing and fixing oxidized M.S.Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) |
| 403 | Providing and fixing ISI:12817 marked Stainless Steel Butt Hinges with Stainless Steel screws etc. complete. |
| 404 | 125x64x1.90mm |
| 405 | 100x58x1.90mm |
| 406 | 75x47x1.80mm |
| 407 | 50x37x1.50mm |
| 408 | Providing and fixing ISI:12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete. |
| 409 | 125x64x2.50mm |
| 410 | 100x60x2.50mm |
| 411 | 75x50x2.50mm |
| 412 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : |
| 413 | 125x85x5.5mm(heavytype) |
| 414 | 125x70x4mm(ordinarytype) |
| 415 | 100x85x5.5mm(heavytype) |
| 416 | 100x70x4mm(ordinarytype) |
| 417 | 75x65x4mm(heavytype) |
| 418 | 75x40x2.5mm(ordinarytype) |
| 419 | 50x40x2.5mm(ordinarytype) |
| 420 | Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete: |
| 421 | 150x125x27x5mm |
| 422 | 125x125x27x5mm |
| 423 | 100x125x27x5mm |
| 424 | 75x100x20x3.2mm |
| 425 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : |
| 426 | 250x10mm |
| 427 | 200x10mm |
| 428 | 150x10mm |
| 429 | 100x10mm |
| 430 | Providing and fixing bright finished brass door latch with necessaryscrews etc. complete. : |
| 431 | 300x16x5mm |
| 432 | 250x16x5mm |
| 433 | Providing and fixing bright finished brass 100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 434 | Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 435 | Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. |
| 436 | Providing and fixing special quality bright finished brass cup board or wardrobe locks with four levers of approved quality including necessary screws etc. complete: |
| 437 | Providing and fixing 50mm bright finished brass cupboard or wardrobe knob of approved quality with necessary screws. |
| 438 | Providing and fixing bright finished brass handles with screws etc. complete: |
| 439 | 125mm |
| 440 | 100mm |
| 441 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 442 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35kg and door width upto700mm),with necessary accessories and screws etc. complete: |
| 443 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc.complete: |
| 444 | Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. |
| 445 | Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete. |
| 446 | 300mm weighing not less than 330gms. |
| 447 | 250mm weighing not less than 280gms. |
| 448 | 200mm weighing not less than 240gms. |
| 449 | Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : |
| 450 | 150mm |
| 451 | 115mm |
| 452 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 453 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc.complete. |
| 454 | Providing and fixing special quality chromium plated brass cupboard locks of approved quality with six levers including necessary screws etc. complete : |
| 455 | Providing and fixing chromium plated brass 50mm cupboard or wardrobe knobs with nuts complete. |
| 456 | Providing and fixing chromium plated brass handles with necessaryscrews etc. complete : |
| 457 | 125mm |
| 458 | 100mm |
| 459 | Providing and fixing chromium plated brass casement window fastener with necessary screws etc.complete.: |
| 460 | Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete. |
| 461 | 300mm weighing not less than 330gms |
| 462 | 250mm weighing not less than 280gms. |
| 463 | 200mm weighing not less than 240gms. |
| 464 | ANODIZED ALUMINUM FITTINGS(All fittings shall be ISI marked)Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 465 | 125x75x4mm |
| 466 | 125x63x4mm |
| 467 | 100x75x4mm |
| 468 | 100x63x4mm |
| 469 | 100x63x3.2mm |
| 470 | 75x63x4mm |
| 471 | 75x63x3.2mm |
| 472 | 75x45x3.2mm |
| 473 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 474 | 300x16mm |
| 475 | 250x16mm |
| 476 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 477 | 300x10mm |
| 478 | 250x10mm |
| 479 | 200x10mm |
| 480 | 150x10mm |
| 481 | 100x10mm |
| 482 | Providing and fixing aluminum pull bolt lock anodized ISI marked (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws bolt nuts and washers etc. complete. |
| 483 | Providing and fixing 50 cm long aluminum kicking plate of size 100x3.15 mm, anodized (anodic coating not less than grade AC 10 as per IS : 868),transparent or dyed to required colour or shade with necessary screws etc. complete. |
| 484 | Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 485 | 125mm |
| 486 | 100mm |
| 487 | 150mm |
| 488 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessaryscrews etc. complete : |
| 489 | Single rubber stopper |
| 490 | Twin rubber stopper |
| 491 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 492 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked,with six levers and a pair ofanodized (anodic coating not less than grade AC10 as per IS: 1868) aluminum lever handles of approved quality with necessary screws etc.complete. |
| 493 | Providing and fixing aluminum tee channels (heavy duty) with rollers,stop end in pelmets as curtain rods. |
| 494 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at thespacing of 610 mm centreto centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs48mm wide having one flange of 34mm and other flange 36mm and 0.50mm thick fixed vertically with in flanges off loor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs atspacingof 450 mm centre to centre, and fixing of boards to both side of framework by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners(25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. |
| 495 | 75mm overall thickness partitions with 12.5 thick double skin fire rated Glass Reinforced Gypsum (GRG), plaster board confirming to IS : 2095 (Part 3) 1996 (Board with BIS Certification marks) |
| 496 | 75mm over allthickness partitions with 12.5mmthickdoubleskin tapered edgePlain Gypsum plaster Board confirming to IS : 2095 (Part I) 2011(Board with BIS Certification marks) |
| 497 | 66mm over all thickness partitions with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materialsreinforced with cellulose fiber manufactured through autoclaving process with compressive strength 225 kg /sq.cm, Bending strength 100kg/sq.cm |
| 498 | 66mmover allthicknesspartitionsusing8mmthickdoubleskinnon asbestos multipurpose cement board reinforced with cellulose fiber manufactured through autoclaving process (high pressure steam cured) as perIS: 14862with suitable fiber cement screws |
| 499 | 66mm overall thickness partition using 8 mm thick double skin multi purpose cement bonded wood particle board manufactured as per IS:14276 with suitable cement bonded board screws |
| 500 | Providing and fixing PTMT handles with necessary screws etc. Complete |
| 501 | 125x34x24mm weighing not less than 23gms |
| 502 | 150x34x24mm weighing not less than 26gms |
| 503 | Providing and fixing PTMT butt hinges with necessary screws etc. Complete |
| 504 | 75x60x10mm fitted with 5.5mm dia MS bright bar rod weighing not less than 34gms |
| 505 | 100x75x10mm fitted with 5.5mmdia M.S.bright bar rod weighing not less than 53gms |
| 506 | Providing and fixing PTMT tower bolts with 12 mm one piece rod inside andnecessary screws etc. Complete |
| 507 | 152x42x18mm weighing not less than 60gms |
| 508 | 202x42x18mm weighing not less than 78gms |
| 509 | Providing and fixing PTMT door catcher of length 72mm and dia of 42mm with suitable washers weighing not less than 33gms |
| 510 | Providing and fixing Bamboo jaffery/fencing consisting of superior quality 25 mm dia. (average) half cut bamboo placed vertically and fixed together with three number horizontal running members of hollock wood in scantling of section 50x25mm fixed with nails and G.I.wire on existing support complete as per direction of engineer-in-charge |
| 511 | Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape tothe junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete. |
| 512 | Second class teak wood |
| 513 | Second class deodar wood |
| 514 | Second class kail wood |
| 515 | Providing and fixing 2nd class teak wood lipping/moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/nails on the edges of the pre laminated particle board as per directions ofthe engineer-in-charge |
| 516 | Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminum doors of approved quality with necessary screws etc.complete as per direction of Engineer-in-charge. |
| 517 | Providing and fixing magnetic catcher of approved quality in cupboard /wardrobe shutters including fixing with necessary screws etc. complete. |
| 518 | Triple strip (Vertical type) |
| 519 | Double strip (Horizontal type) |
| 520 | Providing and fixing powder coated telescopic drawer channels 300mm long with necessary screws etc.complete as per directions of engineer-in-charge |
| 521 | Providing and fixing sliding arrangement in racks/cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminum channel section (the payment for C or E channel shall be made separately) |
| 522 | Providing and fixing factory made UPVC door frame madeof UPVC extruded, section having an overall dimension, as below (tolerance+/-1mm with wall thickness 2.0mm +/-0.2mm, corners of the door frame to be joined with galvanized brackets and stainless steel screws, joint mitred and plastic welded. Thehinges side vertical of the frames reinforced bygalvanized MS tube of size 19x19mm and 1mm +/-0.1mm wall thickness and three numbers stainless steel hinges fixed to the frame complete as per manufacturers’ specifications and direction of engineer-in-charge) |
| 523 | Extruded section profile size 48x40mm |
| 524 | Extruded section profile size42x50mm |
| 525 | Providing and fixing to existing door frames |
| 526 | 24mm thick factorymade PVC door shutters made ofstyles and rails ofaUPVChollow sectionofsize 59x24mmand wallthickness2mm+/-0.2mm with inbuilt edging on both sides. The styles andrails mitred and joined at the cornersby means of MS galvanized/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized MS tube of size 20x20mm and1 mm+/- 0.1mm wall thickness. The lock rail made up of‘H’ section, a UPVC hollow section of size 100x24mm and 2mm +/-0.2mm wall thickness fixed to theshutter styles by means of plastic/galvanized MS ‘U’ cleats. T he shutter frame filled with UPVC multi-chambered single panels of size not less than 620mm, having over- all thickness of 20mm and 1mm +/-0.1mm wall thickness. The pannels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized MS rod and fastened with nuts and washers, complete as per manufacturers’ specification and direction of engineer-in-charge. (For W.C and bathroom door shutters). |
| 527 | 30mm thickfactorymade PVCdoor shuttersmadeofstyles and rails ofaUPVChollow sectionofsize 60x30mmand wallthickness2mm+/-0.2mm with inbuilt decorative moulding edging on one sides. The styles and rails mitred and joined at the corners and by means of MS galvanized/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm+/-0.1mmwall thickness. The lockrail made upof ‘H’section, a UPVC hollow section of size 100x30mm and 2mm +/-0.2mm wall thickness fixed to the shutter styles by means of plastic/galvanized MS ‘U’ cleats. The shutter frame filled with UPVC multi-chambered single panels of size not less than 620mm, having over-all thickness of 20mm and 1mm+/- 0.1mm wall thickness.Thepannels filled vertically and tie barat two places by inserting horizontally 6mm galvanized MS rodand fastened with nuts and washers,complete as per manufacturers’specification and direction of engineer-in-charge. |
| 528 | 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVCsection ofthe size of762 mmX 25mm or less as perrequirement withan average wall thicknessof1 mm (±0.3mm). PVCfoam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm.An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along thehinge side of the door. Core of the door shutter should be filled with High DensityPolyurethane foam. The Top & Bottom edges of the shutter are covered with an end-capof the size25mmX11mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures.Stickers indicating the locations of hardware will be pasted at appropriate places |
| 529 | Providing and fixing factory made PVC door frames of size 50x47mm with a wall thicknessof5mm,madeout ofextruded 5mmrigidPVCfoam sheetmitred at corners and jointed with two numbers of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The doorframe to be fixed to the wall using MS screws of 65/100mm size complete as per manufacturers’specifications and directions of engineer-in-charge |
| 530 | Providing and fixing 30 mm thick factory made panel PVC door shutter consisting offramemadeout ofM.S. tubes of19 gaugethickness and sizeof19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out ofwhich 75mm shall be flat and20mm shall be taperedin 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out ofwhich 75mm shall beflatand20mm shall betaperedon bothsides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVCsheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width isto be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. |
| 531 | Plain PVC door shutters |
| 532 | Pre-laminated PVC door shutters |
| 533 | Providing and fixing fiber glass reinforced plastic (FRP) door frames of cross section 90mmx45mmhaving singlerebateof32mmx15mmtoreceiveshutter of 30mm thickness The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminates shall be 2 mm thick and shall be filled with suitable wooden block in all three legs. The frame shall be covered with fiber glass from all sides. MS stay shall be provided at the bottom to steady the frame. |
| 534 | Providing and fixing 30mm thick door shutters to existing door frames. |
| 535 | Glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture, made with fire retardant grade unsaturated polyester resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles,with wooden frames and suitable blocks of seasoned wood inside at required places for fixing or fittings, cast monolithically with 5mm thick FRP laminate for panels confirming to TADS6:1993 and / or IS:14856-2000 including fixing to frames |
| 536 | Fiberglass reinforced plastic(FRP) Flush door shutter indifferent plain and wood finished made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all aroundwith suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of FRP laminate confirming to table-3 of IS:14856-2000,complete as per directions of engineer-in-charge. |
| 537 | Providing and fixing factorymade door frame(singlerebate)madeout of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred& Jointed with self drivenself tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. |
| 538 | Providing and fixing factorymade 30mmthick door shutter madeof solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wallthickness of15 mm integrallyextruded on thehinge sideoftheprofilefor better screwholding power. The styles andrailsshall be reinforced with M.S.tubes of size 33 mm x 17 mm x 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet aspanel. Thestyles andrails will be mitred cut andjoint with thehelpofPVC solvent cement &selfdrivenselftapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with thehelpofPVC solvent cement &selfdrivenselftapping screws of size 100 mm x 8 mm complete as per manufacturer’s specifications and direction of Engineer-in-charge. |
| 539 | Non decorative finish |
| 540 | Decorative finish (both side wood grained finish) |
| 541 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive |
| 542 | Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality |
| 543 | 1.5mmthick |
| 544 | 1mm thick |
| 545 | Providing and fixing factory made fiberglass reinforced plastics (F.R.P) chajja 4mm thick of required colour, size and design made by resin transfer moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easydrainage of water & duly reinforced by 2 Nos. vertically and 1 no. horizontally 50x2mm thick M.S flat with 12mm inbuilt hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings. The FRP chajja should be manufactured using unsaturated polyester resin as per IS:6746 duly reinforced with fiber glass chopped strand mat (CSM) as per IS:11551 complete with protective Gel coat U/V coating on top for complete resistance from the extreme temperature,weather & sunlight (Only plan area of chajjas shall be measured for making payments) |
| 546 | Providing and fixing cupboard shutters 25mm thick, with pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade I Type II) having one side decorative lamination and other side a balancing lamination including second class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainlesssteel piano hinges complete as per directions of Engineer-in-charge |
| 547 | Providing and fixing cupboard shutters with 25mm thick veneered particleboard IS: 3097 marked exterior grade (Grade I) of approved make including second class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges complete as perdirections of engineer-in-charge |
| 548 | With decorative veneering on one side and commercial veneering on other side |
| 549 | With non decorative veneering on both sides. |
| 550 | Deduct for providing nickel plated bright finished M.S.Piano hinges instead of Bright Finished stainless steel piano hinges. |
| 551 | Providing and fixing factory made flushdoorshutters 30 mm thick made ofpre- laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination of approved shade and other side balancing lamination including second classteak wood lipping of 25mm wide x 12mm thick with necessary screws and black enameled M.S.butt hinges complete as per directions of Engineer-in-charge |
| 552 | Providing and fixing 15 cmhigh drawer of the cupboard with 12 mm thick base and side planks with wooden handles and 20x25 mm runner fixed with screws complete including painting and polishing.Note:Over all plan area of the drawer shall be measured. |
| 553 | FirstclassTeakWood |
| 554 | SecondclassTeakWood |
| 555 | SecondclassDeodarWood |
| 556 | FirstclassKailWood |
| 557 | SecondclassKail Wood |
| 558 | Providing and fixing 25 mm thick factory made shutters of pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823GradeITypeII, ofapproveddesignandedgessealedwith waterresistant paint and lipped with aluminum ‘U’ type edge beading all-round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminum hinges 100x63x4mm etc. Complete as per architectural drawing and directions of Engineer-in-charge (cost of ‘U’ beading and hinges will be paid for separately) |
| 559 | Providing and fixing aluminum‘U’beading of required size to pre-laminated / flush door shutter including fixing etc. complete as per directions of engineer-in-charge. |
| 560 | Providing and fixing,in position concealed G.I section for wall panelling using board of required thickness fixed on the ‘W’ profile (0.55mm thick) having aknur led web of51.55mm and two flanges of 26mm each with lipsof10.55mm placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves@ 610mm C/C with fully threaded self-tapping dry wall screws.Board is fixed to the ‘W’ profile with 25mm countersunkribbed head screws @ 200mm C/C, all complete as per the drawing and directions of engineer- in-charge. The joints of the boardsare finished with speciallyformulated jointing compoundand48mm wide jointing tape to provide seamless finish. |
| 561 | 10 mm thick Tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure withcompressive strength 225kg/sqcm, Bending strength 100kg/sqcm |
| 562 | Multi purpose cement board reinforced with suitable fibre cement screw.8mm thick cement fibre board as perIS:14862 |
| 563 | 8mm thick Cement bonded wood particle boards per IS:14276 |
| 564 | Plain Gypsum plaster board conforming to IS:2095 (Part -1): 2011 (Board with BIS certification marks)12.5mm thick |
| 565 | Providing and fixing fire resistant door frame of section 143 x 57 mm, having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) dulyfilled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated doorshutters. The frame is fitted withintumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approvedbrand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). |
| 566 | Providing and fixing 50mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as perlaboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make,including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in- charge (paneling to be paid for separately). |
| 567 | Providing and fixing glazing in fire resistant door shutters, fixed panels& partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coatingnot less than 120gm/m²) ofsize20 x 33mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applyinga coat ofapproved fireresistantprimer/powder coatingofnot less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity &radiation control (EW60) and minimum 20 minutes of insulation(EI20). The manufacturers have to give test report/certification of fire glass and the glass should have the stamp showing the value of E,EW&EI.The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible.The maximum glazing sizes hall not be more than 1100x2200mm(wxh) or2.42sqm. |
| 568 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer-in-charge,all complete |
| 569 | Providing and fixing plain lining with necessary screws/nuts&bolts/nails, including a coat of approved primer on one face,and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge (Frame work shall be paid for separately).12mm thick commercial ply conforming to S:1328 BWR type |
| 570 | Providing and fixing PVC Door Frame ofsize 50x47mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitredcutjointsandjoint with 2nos ofPVC bracketofsize190mmx100mm longarms ofcross section size35 x15mm&selfdrivenselftaping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8mm, including providing EPDM rubber gasket weather seal throughoutthe frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. Thedoor frametobefixed tothewall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification anddirectionofEngineer-in-charge. |
| 571 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single pieceextruded solid PVC profiles, 5mm(± 0.2mm)thick,havingstyles &rails (except lock rail) of size 95mm x 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on thehinge side of the profile for better screwholding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, selfdrivenselftapping screws & M.S. rectangular pipes bracket ofsize 190 mm X 100 mm of cross sectionsize 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 x 35x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid corein middle of rail section integrallyextruded, fixing the styles & railswith thehelp of solvent and self drivenself tapping screws of 125 mm x11mm, includingproviding5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 572 | Nondecorativefinish(mattfinish) |
| 573 | Decorativefinish(woodgrainedfinish) |
| 574 | ProvidingandFixing factorymade UPVC door frame, made of UPVC extruded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm ( ± 0.2 mm) , corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners,all complete as pe rmanufacturer’s specificationand direction of Engineer-in-charge. |
| 575 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness2 mm ( ± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cutand joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ±0.2 mm).Lock rail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snap fit beads and panel of size 100 mm x 20 mm, and inserting 2nos tie bar of 6 mm diaand fastening with nuts and washers complete ,all as pe rmanufacturer’sspecification and direction of Engineer-in-charge. |
| 576 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticals sides of the frame reinforced with PVC profile of cross section size28mmx30mmx2mmthickness (±0.2mm)and75mmx200mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos& sizes of anchor dash fastener, all complete as per manufacturer’s specification and direction of Engineer-in-charge |
| 577 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and railsmadeofPVChollowextruded printedandlaminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20mm printed &laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer’s specification and direction of Engineer-in-charge. |
| 578 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles dulyreinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shallbe also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) |
| 579 | Casement window single panel with S.S. friction hinges (300 x 19 x1.9 mm), made of (small series) frame 47 x 50 mm &sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) |
| 580 | Casement windowdouble panels with S.S. friction hinges (300x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqmupto1.50 sqm). |
| 581 | Casement window double panels with top fixed with S.S. friction hinges (350 x19 x 1.9mm)made of(small series) frame47x 50 mm, sash 47x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). |
| 582 | Casement window single panel with S.S.friction hinges(400x19x 1.9mm)made of (big series )frame 67 x60mm &sash 67 x80 mm both having wall thickness of 2.3 ± 0.2mmand single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) |
| 583 | Casement window double panels with S.S. friction hinges (350 x19 x1.9 mm) made of (big series) frame 67 x 60 mm & sash /mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 584 | Casement cum fixed pane lwindow having bothend single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350x 19 x1.9) made of(big series) frame 67 x 60mm, sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/doubl eglazing bead of appropriate dimension. (Areaof windowa bove 3.00 sqm upto5.00 sqm). |
| 585 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (whereever required)extruded profilesdulyreinforced with1.60±0.2mmthick galvanizedmild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frameto finished wall, plastic packers, plastic caps and necessarystainless steel screws etc. Profile offrameshall be mitredcut andfusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixinghardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backerrod of required size and of approved quality, all completeas per approved drawing& direction ofEngineer-in-Charge. (Single/ double glass panes and silicon sealant shall be paid separately).:-Fixedwindow/ventilatormadeof(smallseries)frame47x50mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 586 | Providing and fixing factory made uPVC white colour casement /Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (whitepowdercoated) 3D hinges and one handle on eachside of panels along with zinc plated mild steel multi point locking having transmission gear, cylinderwith keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shallbe also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).:- |
| 587 | Casement door with 3D hinges made of (big series) frame 67 x 64 mm &sash 67 x 110 mm both having wal thickness of 2.3 ± 0.2mm and single glazing bead/ double glazing bead ofappropriate dimension .(Area ofdoor upto 2.00 sqm). |
| 588 | Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead/double glazing bead o fappropriatedimension.(Areaof door upto2.50sqm) |
| 589 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame within-built roller track and sash extruded profilesduly reinforced with1.60±0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriatedimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded a all corners,including drilling ofholesfor fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as perapproved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 590 | Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 591 | Threetrackthreepanels slidingwindow with flyproofSS wiremesh (Two nos. glazed & one no. wire meshpanels) made of (small series) frame 92x 44 mm & sash32 x 60 mmboth having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm). |
| 592 | Twotrack twopanelssliding windowmadeof(big series) frame67 x 50 mm & sash46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm andsingleglazingbead /doubleglazing beadof appropriatedimension.(Areaof window above 1.75 sqm upto 2.50 sqm). |
| 593 | Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & oneno. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm). |
| 594 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and singl eglazing bead/double glazingead of appropriate dimension.(Area of window above1.75 sqm) |
| 595 | Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi- chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),appropriate dimension of uPV Cextruded glazing beads, uPVC extruded interlocks and uPVC extruded In line sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy(white powder coated) touch lock with hook (ifrequired for wiremesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 596 | Two track two panels sliding window made of (big series) frame 67x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.) |
| 597 | Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriatedimension.(Area of window above 4.00sqmupto8.00 sqm). |
| 598 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mildsteel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile offrame & sash shall be mitred cut andfusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately):-Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqmupto5.00 sqm) |
| 599 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mildsteel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile offrame & sash shall be mitred cut andfusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately):-Two track two panels sliding door made of (big series) frame67x 50mm & sash 46x82mm bot having wall thickness of 2.3±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqmupto5.00 sqm) |
| 600 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mildsteel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile offrame & sash shall be mitred cut andfusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately):-Three track three panels sliding door madeof(big series) frame116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) |
| 601 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mildsteel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile offrame & sash shall be mitred cut andfusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbacker rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately):-Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & oneno. wiremesh panels) made of (big series) frame116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofdoor above 2.00sqm upto 5.00sqm) |
| 602 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.:-200x 19x1.9mm |
| 603 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.: 250x 19x1.9mm |
| 604 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.:-300x 19x1.9mm |
| 605 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.:- 350x 19x1.9mm |
| 606 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge.:-400x 19x1.9mm |
| 607 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPV Ccasement window with necessary screws etc.complete. |
| 608 | Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc.complete |
| 609 | Providing and fixing steel roller for UPVC sliding window with necessary screws etc.complete. |
| 610 | Providing and fixing steel roller for UPVC sliding door with necessary screws etc.complete. |
| 611 | Providing and fixing steel (white powder coated)crescent lock for UPVC sliding window/ door with necessary screws etc.complete |
| 612 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctionsandfixingtheframetowall/ceiling/ floorswith steel dashfastenersof 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc.complete,all as per direction of Engineer-in-charge. |
| 613 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm onvertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulationhavingdensitymin 96Kg/m³.The frame will have a provision of G.I. Anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in theopening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer-in charge.(Cost of SS ball bearing hinges is excluded). |
| 614 | Providing and fixing 60 mm thick glazed fire resistant door shutters of120 min Fire Rating confirming to IS:3614 (PartII) or EN1634-1:1999,tested and certified as per laboratory approved by Engineer-in-charge,with suitable mounting on door frame, consisting of vertical styles, top rail &siderail 60mm x60mm wide and bottom rail of 110mmx60mm made out of 1.6mm thick G.I. sheet (zinc coating not less than120gm/m²) duly filled mineral wool insulation having densitymin 96 kg/ m³and fixingwith necessarystainlesssteel ball bearing hinges of size 100x89x3mm of approved make, including applyinga coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for separately). |
| 615 | Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120minutes Fire Rating, made out toa profileofdimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet asper test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed tothe supporting construction bymeans ofanchor fastenersofsize M10x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement offrame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/ m³ and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desiredshadeasperNBC2016,IS16231(Part3):2016anddirectionsofEngineer-in-charge. |
| 616 | Providing and fixing glazing in fire resistant door shutters, fixed panels& partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coatingnot less than 120gm/m²) ofsize20 x 33mm screwed with M4 x 38 mm SS screws at distance 75mm from the edges and 150mm c/c,including applying a coat of approved fire resistant primer/powder coatingofnotless than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturers have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accreditedlab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible.The maximum glazing size shall not be more than 1100x2200mm (wxh) or 2.42sqm. |
| 617 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.- 125mm |
| 618 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.- 100mm |
| 619 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.- 75mm |
| 620 | Structural steel workin single section, fixed with or with out connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 621 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 622 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys,complete with bolts, nuts, locking arrangement, stoppers, handles, including applying apriming coat of approved steel primer, |
| 623 | Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonals braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners, 25mm dia pulley, 40x40x6mm angleandT-iron guide at the top and bottom respectively including applying apriming coat of approved steel primer, |
| 624 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 625 | Using M.S.angles 40x40x6mm for diagonal braces |
| 626 | Using flats 30x6mm for diagonal braces and central cross piece. |
| 627 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1and M.S. top cover of required thickness for rolling shutters. |
| 628 | 80x1.25mm M.S.laths with 1.25mm thick top cover |
| 629 | 80x1.20mm M.S.laths with 1.20mm thick top cover |
| 630 | 80x0.90mm M.S.laths with 0.90mm thick top cover |
| 631 | Providing and fixing ball bearing for rolling shutters. |
| 632 | Extra for providing mechanical device chain crank operation for operating rolling shutters.Exceeding 10.00sqm and upto16.80 sqm in the area & Exceeding16.80 sqm in area |
| 633 | Extra for providing grilled rolling shutters manufactured out of 8mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured.) |
| 634 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position andapplying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete. |
| 635 | Hot finished welded type tubes |
| 636 | Hot finished seamless type tubes |
| 637 | Electric resistance or induction butt welded tubes |
| 638 | Providing and fixing mild steelrings of 6mm round bar and 40mm internal dia for fastening ropes of chicks |
| 639 | Providing and fixing M.S. fan clamp of 16mm dia M.S. bar, bent to shape with hooked ends in R.C.C, slabs or beams during laying, including painting the exposed portion of loop,all as per standard design complete. |
| 640 | Providing and fixing circular/hexagonal cast iron box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5mm thick M.S. sheet with itstop surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet boxbymeans of 3.3mm dia. round headed screws, one lock at thecorners.Clampsshall bemadeof12mm diaM.S. barbent to shape as per standard drawing. |
| 641 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 642 | Providing and fixing bolts including nuts and washers complete. |
| 643 | Welding,including transportation of plant at site etc. complete |
| 644 | Bygas plant |
| 645 | Byelectric plant |
| 646 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 647 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 648 | In gratings, frames, guardbar, ladder, railings, brackets, gates and similar works. |
| 649 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, stair case railing and similar works, including applying priming coat of approved steel primer. |
| 650 | M.S.tube |
| 651 | E.R.W.tubes |
| 652 | G.I. pipes |
| 653 | Providing and fixing carbon steel galvanized (minimum coating 5 micron)dash fastener of 10 mmdia double threaded 6.8 grade (yield strength 480 N/mm2) counter sunkhead, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete masonry etc. as per direction of Engineer-in-charge. |
| 654 | 10x60mm |
| 655 | 10x80mm |
| 656 | 10x120mm |
| 657 | 10x140mm |
| 658 | 10x160mm |
| 659 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessarystainless steelnutsandbolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts,fasteners etc.). |
| 660 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. |
| 661 | Galvanized M.S wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 662 | Stainless steel (grade304) wire gauze of 0.5mm dia wire and 1.4 mm aperture on both sides. |
| 663 | Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer,all complete as per the direction of Engineer-In-charge. |
| 664 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 gradedstone aggregate) finished with a floating coat of neat cement including cement slurryand curing complete, but excluding the cost of nosing of steps etc. complete. |
| 665 | 25 mm thick with 12.5 mm nominal size stone aggregate. |
| 666 | 40mm thick with 20 mm nominal size stone aggregate. |
| 667 | 50 mm thick with 20mm nominal size stone aggregate. |
| 668 | 52mm thick cement concrete flooring with concrete hardener topping, under layer 40mm thick cement concrete1:2:4(1cement:2 coarses and :4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardenerconsisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cements lurry and curing complete, but excluding the cost of no sing of steps etc.complete. |
| 669 | 62mm thick cement concrete flooring with concrete hardener topping under layer 50mm thick cement concrete 1:2:4 (1cement :2coarse sand :4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardenerconsisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of no sing of steps etc.complete. |
| 670 | Cement plaster skirting upto 30cm height with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement and curing complete. 18mmthick. |
| 671 | Red oxide plaster skirting (upto 30cm height) with top layer of 6 mm thick plasterof cement mortar red oxide mix, using 3.5 kg of red oxideof iron per 50 kg of cement in mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of cement red oxide mix of same proportion. |
| 672 | 18mm thick with under layer12mm thick cement plaster1:3 (1cement: 3coarse sand) |
| 673 | 21 mm thick with under layer 15 mm thick cement plaster 1:3 (1cement: 3 coarse sand). |
| 674 | Cement concrete pavement with1:2:4 (1cement: 2coarse sand: 4graded crushed stone aggregate 20mm nominal size)including finishing and curing complete. |
| 675 | Extra for making chequers of approved pattern on cement concrete floors,steps, landing, pavementsetc |
| 676 | TERRRAZO FLOORING40mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size and top layer 6 mm thick with white, black, chocolate, grey, yellowor green marble chips of sizes from 1mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume including cement slurry and curing complete : |
| 677 | Dark shade pigment with ordinary cement. |
| 678 | Light shade pigment with white cement. |
| 679 | Medium shade pigment with 50% white cement and 50% ordinary cement. |
| 680 | White cement without any pigment. |
| 681 | Light shade pigment with ordinary cement. |
| 682 | Ordinary cement with out any pigment. |
| 683 | 40mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 9mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4 mm to 7mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder : 7 marble chips) byvolume including cement slurry and curing complete : |
| 684 | Dark shade pigment with ordinary cement. |
| 685 | Light shade pigment with white cement. |
| 686 | Medium shade pigment with 50% white cement and 50% ordinary cement. |
| 687 | White cement without any pigment. |
| 688 | Light shade pigment with ordinary cement. |
| 689 | Ordinary cement without any pigment. |
| 690 | 40mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 28mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix :3 marble chips) by volume including cement slurry and curing complete : |
| 691 | Dark shade pigment with ordinary cement. |
| 692 | Lightshadepigmentwithwhitecement. |
| 693 | Medium shade pigment with 50% white cement and 50% ordinary cement. |
| 694 | White cement without any pigment. |
| 695 | Light shade pigment with ordinary cement. |
| 696 | Ordinary cement without any pigment. |
| 697 | Marble chips skirting upto 30 cm height, rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizesfrom smallest to 4 mm nominal size, laid in cement marble powder mix 3:1 ( 3 cement : 1marble powder) byweight in proportion of 4:7(4cementmarble powder mix : 7 marble chips) by volume : 18mm thickwith under layer 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand) – |
| 698 | Dark shade pigment with ordinary cement. |
| 699 | Light shade pigment with white cement. |
| 700 | Medium shade pigment with 50% white cement and50% ordinarycement. |
| 701 | White cement without any pigment. |
| 702 | Light shade pigment with ordinary cement. |
| 703 | Ordinary cement without any pigment. |
| 704 | Providing and fixing strips in joints of terrazzo/cement concrete floors. Glasss trips |
| 705 | 40mm wide and 4mm thick |
| 706 | 40mm wide and 6mm thick. |
| 707 | Extra for terrazzo flooring laid as floor borders, margins and similar bands exceeding7.5cm but not exceeding 30cm in width. |
| 708 | Extra for laying terrazzo flooring on stair case treads not exceeding 30cm in width, including cost of forming, nosing etc |
| 709 | Extra for laying terrazzo in narrow bands not exceeding 7.5cm in width. |
| 710 | Extra for making moulded no singin terrazzo including returned moulded ends and angles to mouldings. |
| 711 | Special surface finishing to teads,riser sand the ends of concrete steps and the like,including form work |
| 712 | Crazy marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture ( 3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 ( 4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size), including rubbing, polishing and cement slurry and curing complete.18mm thick crazy marble stone white,black or as specified. |
| 713 | TILE FLOORINGPrecast terrazzo tiles 22mm thick with graded marble chips of size upto 12 mm, laid in floors, and landing,jointed with neat cement slurrymixed with pigment to match the shade of the tiles including rubbing polishingandcuringcomplete, on 20mm thickbedofcement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 714 | Light shade using white cement |
| 715 | Medium shade using 50% white cement and 50% ordinary cement. |
| 716 | Dark shade using ordinary cement. |
| 717 | Ordinary cement without any pigment. |
| 718 | Extra if terrazzo tiles are laid intreads of steps not exceeding 30cm in width. |
| 719 | Precast terrazzo tiles 22mm thick with graded marble chips of size upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1cement : 3coarse sand),jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curing complete with tiles of : |
| 720 | Light shade using white cement |
| 721 | Medium shade using 50% white cementand 50% ordinary cement. |
| 722 | Dark shade using ordinary cement. |
| 723 | Ordinary cement without any pigment. |
| 724 | Precast terrazzo tiles 22mm thick with graded marble chips of size upto 12mm fixed on walls, on 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curing complete with tiles of : |
| 725 | Light shade using white cement |
| 726 | Medium shade using 50% white cement and 50% ordinary cement |
| 727 | Dark shade using ordinary cement. |
| 728 | Ordinary cement without any pigment. |
| 729 | Extra if cut tiles other than half tiles are used in risers of steps,skirting and dado. |
| 730 | Chequerred terrazzo tiles 22mm thick with graded marble chips of size upto 6mmin floors,jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curingcomplete,on20mm thick bed of cement mortar 1:4(1cement:4 coarse sand) . |
| 731 | Light shade using white cement |
| 732 | Medium shade using 50% white cement and 50% ordinary cement. |
| 733 | Dark shade using ordinary cement. |
| 734 | Ordinary cement without any pigment. |
| 735 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . |
| 736 | Light shade using white cement |
| 737 | Medium shade using 50% white cement and 50% ordinary cement. |
| 738 | Dark shade using ordinary cement. |
| 739 | Ordinary cement without any pigment. |
| 740 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per direction of Engineer-in-charge |
| 741 | In flooring on a bed of 10mm thick mortar 1:4 (1acidproof cement : 4 coarse sand) |
| 742 | In dado/skirting on 12mm thick mortar 1:4 (1 acid proofcement : 4 coarse sand) |
| 743 | Tile work in skirting, risers of step and dedoupto 2 metre height, over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. Marble tiles (polished) Raj Nagar.( 8mm thick ) |
| 744 | MARBLESTONEFLOORINGFlooringwith marble stone of specified thickness as per sample of marbleapproved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with:-- 16mm |
| 745 | MakranaWhiteSecondquality |
| 746 | MakranaDoongriadangaveined. |
| 747 | RajNagarplain |
| 748 | AgariaWhite |
| 749 | Blackzebra |
| 750 | Udaipurgreenmarble |
| 751 | Pinkplainmarble |
| 752 | MARBLESTONEFLOORINGFlooringwith marble stone of specified thickness as per sample of marbleapproved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with:-- 18mm |
| 753 | MakranaWhiteSecondquality |
| 754 | MakranaDoongriadangaveined. |
| 755 | RajNagarplain |
| 756 | AgariaWhite |
| 757 | Blackzebra |
| 758 | Udaipurgreenmarble |
| 759 | Pinkplainmarble |
| 760 | Extra for pre finished nosing to treads of steps of marble stone |
| 761 | Extra for marble stone flooring in treads of steps and risers using single length upto 2.00meter. |
| 762 | KOTASTONEFLOORINGKota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed withpigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4(1 cement : 4 coarse sand) : |
| 763 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing, polishing and curing complete. |
| 764 | SANDSTONEFLOORING40mm thick fine dressed stone flooring over 20mm (average) thick base of cement mortar1:5 (1 cement: 5 coarse sand)with joints finishedflush and curing complete: Redsandstone |
| 765 | 40mm thick fine dressed stone flooring over 20mm (average) thick base of cement mortar1:5 (1 cement: 5 coarse sand)with joints finishedflush and curing complete: Whitesandstone |
| 766 | 40mm thick fine dressed stone flooring over 20mm (average) thick base ofcement mortar1:5 (1cement: 5coarse sand), including pointing with cement mortar 1:2 ( 1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone and curing complete. Redsandstone |
| 767 | 40mm thick fine dressed stone flooring over 20mm (average) thick base ofcement mortar1:5 (1cement: 5coarse sand), including pointing with cement mortar 1:2 ( 1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone and curing complete. Whitesandstone |
| 768 | 40 mm thick fine dressed and rubbed stone flooring over 20mm(average) thick base of cement mortar1:5 (1 cement: 5 coarse sand), with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement :2 stone dust) admixture with pigment to match the shade of stone and pointing with the same mortar and curing complete. Redsandstone |
| 769 | 40 mm thick fine dressed and rubbed stone flooring over 20mm(average) thick base of cement mortar1:5 (1 cement: 5 coarse sand), with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement :2 stone dust) admixture with pigment to match the shade of stone and pointing with the same mortar and curing complete. Whitesandstone. |
| 770 | Extra for pre finished nosing in treads of steps of kota stone/sand stone slab. |
| 771 | Extra for kotastone /sand stone flooring in treads of steps and risers using single length upto 1.05 meter. |
| 772 | WOODENFLOORINGWooden planking,tongued and grooved in flooring including fixing with iron screws complete: 12mmthick |
| 773 | Second class teak wood |
| 774 | Secondclassdeodarwood |
| 775 | Wooden planking,tonguedandgrooved in flooringincluding fixingwith iron screws complete: 15mmthick |
| 776 | Secondclassteakwood |
| 777 | Secondclassdeodarwood |
| 778 | Wooden planking,tonguedandgrooved in flooringincluding fixing with iron screws complete.18mmthick |
| 779 | Second class teak wood |
| 780 | Second class deodar wood |
| 781 | Wooden planking,tongued and grooved in flooring including fixingwith iron screws complete: 25mmthick |
| 782 | Second class teak wood |
| 783 | Second class deodar wood |
| 784 | 38mm thick wood block flooring of first class teak wood laid over 25mm thick leveling layer of cement concrete 1:2:4 (1cement: 2coarse sand: 4 graded stone aggregate10mm nominal size) to be paid separately coated, with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. |
| 785 | Extra for plaining the lower surface of wooden planking |
| 786 | Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5mm,10cmlong, forkedat end60cmapart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. |
| 787 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make,laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour suchas White, Ivory,Grey,FumeRedBrown |
| 788 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make,laid on 20mm thick bed of cement mortar 1:4( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours,shades,except White, Ivory, Fume Red Brown |
| 789 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS: 15622 (thicknesstobespecified bythe manufacturer )ofapproved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge inskirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg persqm including pointing in white cement mixed with pigmentof matching shade complete. |
| 790 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more(thickness to be specified by the manufacturer),of 1st qualityconforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matchingpigments etc., complete. |
| 791 | In colour such asWhite,Ivory,Grey,Fume Red Brown |
| 792 | In all colours,shades,except White,Ivory,Fume Red Brown |
| 793 | VITRIFIEDFLOORTILESProviding and laying vitrified floor tiles in different sizes(thickness tobe specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 794 | Size of tile 500x500mm |
| 795 | Size of tile 600x600mm |
| 796 | Size of tile 800x800mm |
| 797 | Size of tile 1000x1000mm |
| 798 | Deduct for not using 20mm thick cement mortar 1:4 (1cement: 4coarse sand)bedding in laying of floor tiles. |
| 799 | Providing and laying Vitrified tiles in floor with different sizes(thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based)conforming to IS: 15477,in average 6mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 800 | Size of tile 500x500mm |
| 801 | Size of tile 600x600mm |
| 802 | Size of tile 800x800mm |
| 803 | Size of tile 1000x1000mm |
| 804 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 805 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. |
| 806 | Size of tile 500x500mm |
| 807 | Size of tile 600x600mm |
| 808 | Size of tile 800x800mm |
| 809 | Size of tile 1000x1000mm |
| 810 | Providingandfixingglazedscreen printed border tile 75mm wide having thickness 5mm, of approved quality &make, in all shades, design and prints, in dado, over 12mm thick bed of cementmortar 1:3 (1 Cement :3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade,all complete as approved by Engineer-in-Charge |
| 811 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 812 | Size of tile 500x500mm |
| 813 | Size of tile 600x600mm |
| 814 | Size of tile 800x800mm |
| 815 | Size of tile 1000x1000mm |
| 816 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 817 | Size of tile 500x500mm |
| 818 | Size of tile 600x600mm |
| 819 | Size of tile 800x800mm |
| 820 | Size of tile 1000x1000mm |
| 821 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477,in average 3mm thickness |
| 822 | Crazy ceramic tile flooring, with under layer 12mmthick cementmortar 1:4 (1 cement: 4coarse sand), with jointsnot exceeding5mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre,triangular in shape having specific gravity of 1.34to 1.40,cross sectionsize ranging from10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. |
| 823 | Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick fine sand, including spreading,well ramming, consolidating and finishing smooth etc.all complete as per direction of Engineer-in-charge. |
| 824 | Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20mm (average) thick base of cement mortar 1:4(1cement:4 coarses and) laid and jointed with white cement slurry @4.4kg/sqm including pointing with white cement slurry ad mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.a. 18 mm thick Italian Marble stone slab,Perlato, Rossoverona,Fire Redor Dark Emperadore etc. |
| 825 | Providing and laying machine cut, mirror polished Marble stoneflooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc.,in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer- in-Charge. a.18mm thick Italian Marble stone slab,Perlato,Rossoverona, Fire Red or Dark Emperadore etc. |
| 826 | Providing and fixing Glassmossaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5kg per sqm and grouting of the same.The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: |
| 827 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper thearchitectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurryand pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishingetc.all complete as specifiedand as directed by the Engineer-in-Charge Flamed finish granite stone slab JetBlack, CherryRed, Elite Brown,Cat Eye or equivalent. |
| 828 | Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyro grip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. |
| 829 | 300 mm Finished Floor Height (FFH) |
| 830 | 450 mm Finished Floor Height (FFH). |
| 831 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand)laid and jointed with cement slurryand pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black,CherryRed,Elite Brown,CatEye or equivalent. |
| 832 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:-1.60 mm thick with zinc coating not less than 350 gram/m2 |
| 833 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:- 1.25 mm thick with zinc coating not less than 350 gram/m2 |
| 834 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:- 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 835 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:- 0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 836 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:- 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 837 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.:- 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 838 | Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40sq.decimetre for chimney stacks, sky light etc.:- 1.60 mm thick |
| 839 | Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40sq.decimetre for chimney stacks, sky light etc.:-1.25 mm thick |
| 840 | Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40sq.decimetre for chimney stacks, sky light etc.:- 1.00 mm thick |
| 841 | Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40sq.decimetre for chimney stacks, sky light etc. 0.80 mm/0.63 mm/0.50 mm thick |
| 842 | Labour Charges for corrugated G. S. sheet roofing including vertical/curved surface fixed with nails and washers including cutting to size and shape wherever required with necessary scaffolding wherever required as per the directions of Engineer Incharge. |
| 843 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimeter.:- 1.60 mm thick |
| 844 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimeter.:- 1.25 mm thick |
| 845 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimeter.:- 1.00 mm thick |
| 846 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimeter.:-0.80 mm/0.63 mm thick |
| 847 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimeter.:- 0.50 mm thick |
| 848 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.:--0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 849 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.:- 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 850 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.:- 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 851 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.:- 1.60 mm thick with zinc coating not less than 350 gram/m2 |
| 852 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.:- 1.25 mm thick with zinc coating not less than 350 gram/m2 |
| 853 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.:- 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 854 | Providing and fixing flashing of 40cm overall width in plain G.S. sheets fixed with polymer coated J or L hooks, bolts and nuts G.I. limpet and bitumen washers complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand):- 1.25 mm thick with zinc coating not less than 350 gram/m2 |
| 855 | Providing and fixing flashing of 40cm overall width in plain G.S. sheets fixed with polymer coated J or L hooks, bolts and nuts G.I. limpet and bitumen washers complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand):- 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 856 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.:- 0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 857 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.:-0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 858 | Providing flat iron brackets 50x3mm size with necessary bolts, nuts and washers etc.for fixing as bestoscement/G.S.sheets gutters with purlins. |
| 859 | Painting top of roofs with bitumen of approved quality at 17kg per 10sqm impregnated with a cost of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete.with residual type petroleum bitumen of grade VG-10 |
| 860 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc.complete (excluding the cost of purlins, rafters and trusses),including cutting sheets to size and shape wherever required. |
| 861 | Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40square decimeter for chimney stacks,sky lightsetc. |
| 862 | Extra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated /semi corrugated 6mm thick sheet roofing for making openings of area exceeding 40 square decimeter. |
| 863 | Extra for providing and fixing wind ties of 40x6mm flat iron section |
| 864 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. :- Corrugated serrated adjustable ridges |
| 865 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.:- Plain wing adjustable ridges |
| 866 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.:- Close fitting adjustable ridges |
| 867 | Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.:- Unserrated adjustable hips |
| 868 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Corrugated Apron pieces |
| 869 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Eave’s filler pieces |
| 870 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- North light curves |
| 871 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Ventilator curves |
| 872 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Barge boards |
| 873 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Ridge finials |
| 874 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete::- Special North light curves |
| 875 | Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete:;- S type louvers |
| 876 | Providing and fixing UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.:- 2mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\") as specified. |
| 877 | Providing and fixing UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.:- 2mm thick flat |
| 878 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 gramsper sqm as per IS: 277, in 240mpa steel grade, 5-7microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredbyEngineer-in-charge.Thesheetshallbefixedusingselfdrilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,raftersandtrussesandincludingcuttingtosizeandshapewhereverrequired. |
| 879 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :- Ridgesplain(500-600mm) |
| 880 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :- Flashings/Aprons.(Upto600mm) |
| 881 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :-Northlightcurves |
| 882 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :-Bargeboard(Upto300mm) |
| 883 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :-Crimpcurve |
| 884 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete :-Gutter.(600mmoverallgirth |
| 885 | 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa at 35kg per cum of earth and gobri leaping with mix 1:1 (1 clay: 1 cow dung) and covered with specified tile bricks grouted with cement mortar1:3(1cement:3 fines and ) mixed with 2% of integral water proofing compound by weight of cement and finishing neat.:-With common burnt clay (non modular) brick tiles of class designation 10.0 |
| 886 | Extra for every additional 1cm thickness of mud phaska. |
| 887 | Providing and laying common burnt clay(non modular)brick tiles of class designation 10 over mumty roofs grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% ofintegral water proofing compound by weight of cement, over a 12mm layer of cement mortar1:3(1cement: 3fines and) and finished neat. |
| 888 | Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1cement :4 coarse sand) and finished neat complete |
| 889 | Providing and fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). |
| 890 | Providing and fixing on roof pressed clay tile ridge (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). |
| 891 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 892 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 893 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : |
| 894 | Red sand stone slab 40 to 50 mm thick |
| 895 | White sand stone slab 40 to 50 mm thick |
| 896 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws:- 2nd class teak wood |
| 897 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws:- 1st class deodar wood |
| 898 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws:-1st class kail wood |
| 899 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws:-2nd class kail wood |
| 900 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws:-Budloo/fir wood |
| 901 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :-12 mm thickness:- Natural colour insulating board |
| 902 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :-12 mm thickness:-White face insulating board |
| 903 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :-12 mm thickness:-Flame retardant face insulating board |
| 904 | Providing and fixing 12 mm thick flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately) : |
| 905 | Providing and fixing plain multi purpose cement board(Height pressure steam cured) with suitable screws for cement particle boardin ceiling etc. complete (frame work to be paid separately).:-6mmthickCementfiberboardasperIS:14862 |
| 906 | Providing and fixing plain multi purpose cement board(Height pressure steam cured) with suitable screws for cement particle boardin ceiling etc. complete (frame work to be paid separately).:-6 mm thick Cement bonded wood particle board as per IS:14276 |
| 907 | Providing and fixing ceiling in Circular opening including cutting with:- 20 mm thick:- 2nd class Teak Wood planks |
| 908 | Providing and fixing ceiling in Circular opening including cutting with:- 20 mm thick:-1st class Deodar Wood planks |
| 909 | Providing and fixing ceiling in Circular opening including cutting with:- 20 mm thick:- 1st class Kail Wood planks |
| 910 | Providing and fixing ceiling in Circular opening including cutting with:- 12 mm thick Natural colour insulation board |
| 911 | Providing and fixing ceiling in Circular opening including cutting with:- White face insulating board- 12 mm |
| 912 | Providing and fixing ceiling in Circular opening including cutting with:- Flame retardant face insulating board :- 12 mm thick |
| 913 | Providing and fixing ceiling in Circular opening including cutting with:- Flame retardant face insulating board :- Standard quality hard board sheet- 3mm |
| 914 | Providing and fixing ceiling in Circular opening including cutting with:- Flame retardant face insulating board :- Standard quality hard board sheet- 4.5 mm |
| 915 | Extraforprovidingandfixingceilingtocurvedsurfacesinnarrowwidths |
| 916 | Providing and fixing false ceiling with 12mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of syntheticenamel paintofapprovedqualityon exposed face, fixedtoa grid made out of anodized aluminum (with 15 micron anodic coating) T- sections35x15x1.5mm sizemainrunners, cross runners 23.5x19x1.5mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600x1200mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer(aluminum framework shall be paid separately). |
| 917 | Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12mm thick plain or design particle board ceiling tiles. |
| 918 | Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5m above floor level over first class kail wood strips 25x6 mm with 10mm gapin between andreinforced with rabbit wire mesh fixed to wooden frame ( frame work to be paid separately) :-Flatsurfaces |
| 919 | Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5m above floor level over first class kail wood strips 25x6 mm with 10mm gapin between andreinforced with rabbit wire mesh fixed to wooden frame ( frame work to be paid separately) :- Curvedsurfaces |
| 920 | Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous)ceiling. |
| 921 | Extra for providing plaster of Paris (Gypsum anhydrous) ceiling above 5 meters height from floor level. |
| 922 | Providing and fixing 12mm thick plaster of Paris (gypsum anhydrous) ceiling tiles upto a height of 5 Metres above floor level over wooden frames and rendered smooth with plaster of Paris (frame work to be paidseparately). |
| 923 | Extra for providing and fixing Plaster of Paris (Gypsum anhydrous) ceiling tiles beyond 5 metres height from floor level (Height beyond 5 m to be measured for extra payment). |
| 924 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete.:-Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm |
| 925 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete.:-Including providing and fixing minimum 10 mm thick POP (calcium sulphate semi hydrate variety) jute reinforced tiles of 600 mm x 600 mm of plain or of approved design. |
| 926 | Providing and fixing plain, square edged wooden beading 65x12 mm section with screws of approved quality for ceiling:- 2nd class teak wood. |
| 927 | Providing and fixing plain, square edged wooden beading 65x12 mm section with screws of approved quality for ceiling:- 1st class deodar wood. |
| 928 | Providing and fixing plain, square edged wooden beading 65x12 mm section with screws of approved quality for ceiling:-1st class kail wood |
| 929 | Providing and fixing hard board sheet ceiling of approved quality withnecessary nails etc. complete (frame work to be paid for separately):- Standard Quality board:-3mm |
| 930 | Providing and fixing hard board sheet ceiling of approved quality withnecessary nails etc. complete (frame work to be paid for separately):-Standard Quality board 4.5mm |
| 931 | Providing and fixing thermal insulation of ceiling (under deck insulation) with specified glass wool conforming to IS: 8183, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60cm c/c and wire mesh of 12.5mm x 24g wire for top most ceiling of building.:- With resin bonded fiber glass wool with density 24 kg/cum |
| 932 | Providing and fixing thermal insulation of ceiling (under deck insulation) with specified glass wool conforming to IS: 8183, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60cm c/c and wire mesh of 12.5mm x 24g wire for top most ceiling of building.:-With resin bonded rock wool with density 48 kg/cum |
| 933 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire.:-With resin bonded fiber glass wool with density 16 kg/cum |
| 934 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire.:-With resin bonded rock wool with density 48 kg/cum |
| 935 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions of Engineer-in-charge.:-With resin bonded fiber glass wool with density 24 kg/cum |
| 936 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions of Engineer-in-charge.:-With resin bonded rock wool with density 48 kg/cum |
| 937 | Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer- in-charge.:- With Type N-Normal 50 mm thick |
| 938 | Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer- in-charge.:- With Type SE-Self Extinguishing type 50 mm thick |
| 939 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 cement : 4 fine sand):-Stone ware spout. |
| 940 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc.:-100 mm dia. |
| 941 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc.:-150 mm dia. |
| 942 | Providing lead caulked joints to sand cast iron water pipes and fittings :-100 mm dia pipe |
| 943 | Providing lead caulked joints to sand cast iron water pipes and fittings :- 150 mm dia pipe |
| 944 | Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) :-Sand cast iron plain shoes( 150 mm diametre) |
| 945 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes:- 75 mm diametre |
| 946 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes:-110 mm diametre |
| 947 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:-Coupler (75 mm) |
| 948 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Coupler (110 mm) |
| 949 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:-Single push fit coupler (75 mm) |
| 950 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:-Single push fit coupler ( 110 mm) |
| 951 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Single tee with door (75x75x75 mm) |
| 952 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Single tee with door (110x110x110 mm) |
| 953 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Single tee without door 75x75x75 mm |
| 954 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Single tee without door 110x110x110 mm |
| 955 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Bend 87.5° 75 mm bend |
| 956 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Bend 87.5° 110 mm bend |
| 957 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Shoe (plain) 75 mm shoe |
| 958 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.:- Shoe (plain):-110 mm shoe |
| 959 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.:-75 mm |
| 960 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.:-110 mm |
| 961 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 962 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: |
| 963 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks) |
| 964 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part-I : 2011 (Board with BIS certification marks) |
| 965 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 966 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in- charge and as per manufacturer’s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 |
| 967 | 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 968 | Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. |
| 969 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately). |
| 970 | GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 971 | GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 972 | 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from natural gypsum as per IS 2095 part-I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit. |
| 973 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fiber conforming to IS: 2095 part-I, of size 595x595 mm, having perforation of9.7x9.7 mm at 19.4 mm c/c with center borders of 48mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 974 | 8 mm thick fully perforated Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/cm2, bending strength 100 kg/cm2, of size 595x595 mm, having perforation of dia. 10mm with minimum perforated area 18% with non-woven tissue on the back side, having an NRC (Noise Reduction Certificate) of 0.85, with 50 mm thick rock wool of 48 kg/cum backing. |
| 975 | Providing and Fixing 15 mm thick densified tegular edged eco-friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on Perimetre wall angle pre-coated steel size (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (Spin tone / Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’ , bottom exposed with 24 mm of all T-sections shall be pre- painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. |
| 976 | Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with |
| 977 | GI Metal Ceiling Clip in plain Beveled edge global white colour tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 978 | GI Metal Ceiling Clip in plain Beveled edge global white colour tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum),including factory painted after bending and perforation. |
| 979 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection> 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 980 | Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per liter, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. |
| 981 | Providing and fixing plained eaves boarding.:- 2nd class Deodar wood (250x32 mm (nominal size)) |
| 982 | Providing and fixing plained eaves boarding.:- 2nd class Deodar wood(300x40 mm (nominal size) |
| 983 | Providing and fixing plained eaves boarding.:- -2nd class kail wood-250x32 mm (nominal size ) |
| 984 | Providing and fixing plained eaves boarding.:-2nd class kail wood-300x40 mm (nominal size) |
| 985 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacturer’s specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., and washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-charge. |
| 986 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Changez Khani |
| 987 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Chaar Gul |
| 988 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Chaar Phool |
| 989 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Pahal Gardan |
| 990 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Dawaz-dal-i-girde |
| 991 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Paanch Murabah |
| 992 | CEMENTPLASTER(INFINESAND / INCOARSESAND)12mm Cement plaster of mix: |
| 993 | 1 :4( 1cement: 4fine sand) |
| 994 | 1 :6( 1cement: 6fine sand) |
| 995 | 15mm Cement plaster on the rough side of single or half brick wall of mix: |
| 996 | 1 :4( 1cement :4 finesand) |
| 997 | 1 :6( 1cement: 6 finesand) |
| 998 | 20mm Cement plaster of mix: |
| 999 | 1 :4( 1cement:4finesand) |
| 1000 | 1:6( 1cement:6finesand) |
| 1001 | CEMENTPLASTERWITHAFLOATINGCOATOFNEAT CEMENT12mm Cement plaster finished with a floating coat of neat cement of mix: |
| 1002 | 1 :3( 1cement:3finesand) |
| 1003 | 1 :4( 1cement:4finesand) |
| 1004 | 15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 1005 | 1 :3( 1cement:3finesand) |
| 1006 | 1 :4( 1cement:4finesand) |
| 1007 | 20mm cement plaster finished with a floating coat of neat cement of mix: |
| 1008 | 1 :3(1cement:3finesand) |
| 1009 | 1 :4( 1cement:4finesand) |
| 1010 | Cement plaster1 : 3 (1 cement : 3 coarse sand) finished with a floatingcoat of neat cement |
| 1011 | 12mm cement plaster |
| 1012 | 20mm cement plaster |
| 1013 | 15mm Cement plaster 1:3 (1cement: 3coarses and) finished with afloating coat of neat cement on the rough side of single or half brick wall |
| 1014 | CEMENTPLASTERINTWO COATS18mm Cement plasterin two coats under layer 12mm thick cementplaster 1:5(1cement :5coarsesand)finishedwithatoplayer 6mm thick cementplaster 1 : 6 (1 cement : 6 fine sand) |
| 1015 | 18mm Cement plasterin two coats under layer 12mm thickcementplaster 1:5(1cement: 5coarses and)finished with a top layer 6mm thick cement plaster 1:3 (1cement: 3coarse sand) finished rough with sponge |
| 1016 | 12mm Cement plaster 1:2 (1cement:2Stone dust) |
| 1017 | 15mm Cement plaster 1:2(1cement: 2Stone dust)on the rough side of single or half brick wall |
| 1018 | 20mm Cement plaster 1:2 (1cement:2Stonedust) |
| 1019 | 6MMCEMENTPLASTER6mmcementplastertoceilingofmix1:3(1cement:3finesand) |
| 1020 | Neatcementpunning |
| 1021 | CEMENTLIME PLASTER12mmcementlimeplaster ofmix: |
| 1022 | 1:1:6 (1 cement:1limeputty:6 finesand |
| 1023 | 15mmcement lime plasteronroughside ofsingle orhalfbrickwallof mix1 : 1 : 6 (1 cement : 1 lime putty : 6 fine sand) |
| 1024 | ROUGHCASTPLASTERRough cast plaster upto 10m height above groundlevel with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. |
| 1025 | Ordinarycementfinishusingordinarycement |
| 1026 | PEBBLEDASHPLASTERPebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers,under layer 12mm cement plaster 1:4 (1 cement: 4 Coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 10% finely groundedhydrated lime by volume of cement. |
| 1027 | Providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers: |
| 1028 | Extra for plastering exterior walls of the height more than 10m from ground level for every additional height of 3m or part there of. |
| 1029 | Extra for plastering on circular work not exceeding 6min radius: |
| 1030 | Inonecoat |
| 1031 | Intwocoats |
| 1032 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level : |
| 1033 | Inonecoat |
| 1034 | Intwocoats |
| 1035 | Extraforplastering |
| 1036 | SphericalCeiling |
| 1037 | Groinedceiling |
| 1038 | FlewingSoffits |
| 1039 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 1040 | ARTIFICIALSTONEPLASTERExtra for lining out plaster to imitates tone or concrete blocks walling |
| 1041 | 18mm thick artificial red stone plaster consisting of 12mm under coat of cement plaster 1 : 4 (1 cement : 4 coarse sand) with 6mm thick finishing coat of cement mortar 1: 1 : 3 (1 cement : 1 marble dust : 3 stone dust) mixed with red oxide to match the shade of red stone |
| 1042 | TERRAZOPLASTER18mm plastering with terrazzo finish rubbed and polished complete, under layer 12mm thick cement plaster 1 :3 (1 cement : 3 coarse sand) and top layer 6mm thick white, black, chocolate, grey, yellow or Baroda green marble chipsof3mm anddown sizelaidin cement marble powder mix3: 1(3cement:1marble powder)by weightin proportion 4:7(4cementmarble powder mix: 7marble chips ) by volume |
| 1043 | Extra if white cement is used instead of ordinary cement in to player of 18mm thick plastering with terrazzo finish |
| 1044 | Extra ifcolor isaddedtogreyor white cementin toplayer of18mm thick plastering with terrazzo finish : |
| 1045 | Red,Chocolate,OrangeorBuff(yellow)colour |
| 1046 | BlackColour |
| 1047 | Blueor GreenColour |
| 1048 | Extra for 18mm thick terrazzo finish marble chips plaster in circular work not exceeding 6 meter radius |
| 1049 | PLAINCEMENTMORTARBANDS12mm thick plain cement mortar bands in cement mortar 1: 4(1cement : 4 fine sand) |
| 1050 | FlushBand |
| 1051 | sunkBand |
| 1052 | RaisedBand |
| 1053 | Mouldedband |
| 1054 | 18mm thick plain cement mortar band in cement mortar1:4(1cement :4 fine sand) |
| 1055 | Flush Band |
| 1056 | Sunk Band |
| 1057 | Raised Band |
| 1058 | Moulded band |
| 1059 | 18mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1 :5 (1 cement : 5 coarse sand) top layer 6mm thick with cement mortar 1 : 4 (1 cement : 4 fine sand) |
| 1060 | POINTINGONBRICKWORKPointing on brick work or brick flooring with cement mortar1:3 (1 cement : 3 fine sand) |
| 1061 | Flush/Ruled/StruckorweatheredPointing |
| 1062 | RaisedandcutPointing |
| 1063 | Pointing on brick work or brick flooring with cement mortar1:4 (1 cement : 4 fine sand) |
| 1064 | Flush/Ruled/StruckorweatheredPointing |
| 1065 | POINTINGONTILEBRICK WORKPointing on tile brick work with cement mortar1 :3 (1cement:3fine sand) |
| 1066 | Flush/Ruled/StruckorweatheredPointing |
| 1067 | POINTINGONSTONEWORKPointing on stone work with cement mortar1:3(1cement:3finesand) |
| 1068 | Flush/RuledPointing |
| 1069 | Raisedandcut pointing |
| 1070 | Raised and cut pointing on stone work in white cement mortar1:3(1 white cement: 3 marble dust) |
| 1071 | Extra for pointing on walls on the outside at height more than 10m from ground level for every additional height of 3m or part thereof. |
| 1072 | INTERIORFINISHINGWhite washing with lime to give an evenshade onNew Work (three ormore coats) |
| 1073 | Colour washing such asgreen blue or buff to give an even shade |
| 1074 | New work (two or more coats) with a basecoat of white washing with lime. |
| 1075 | New work (two or more coats)with base coat of whiting |
| 1076 | Distempering with dry distemper of approved brand and manufacture (two or more coats)and of required shade on new work,over and including water thinnable priming coat to give an even shade |
| 1077 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 1078 | Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 1079 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 1080 | EXTERIORFINISHINGFinishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 1081 | FinishingwallswithtexturedexteriorpaintofrequiredshadeonNewwork (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 1082 | FinishingwallswithacrylicsmoothexteriorpaintofrequiredshadeonNewwork(Two or more coats [email protected]/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 1083 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied@ 1.43liter/10sqm over and including priming coat of water exterior paint [email protected]/10sqm) |
| 1084 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’specifications: |
| 1085 | Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm |
| 1086 | Painting wood work with deluxe multi surface paint of required shade.Two or more coats [email protected]/10sqm overan under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 1087 | Painting steel work with deluxe multi surface paint of required shade to give an even shade.Two or more coats applied @ 0.90litre/10 sqm over an under coat of primer [email protected]/10 sqm of approved brand and manufacture |
| 1088 | Applying priming coat: |
| 1089 | With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 1090 | With ready mixed aluminum primer of approved brand and manufacture on resinous wood and ply wood |
| 1091 | With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works |
| 1092 | WithreadymixedredoxideZincChromateprimerof approved brand and manufacture on steel work (second coat) |
| 1093 | Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: |
| 1094 | One coat |
| 1095 | Two coats |
| 1096 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete |
| 1097 | On steel work |
| 1098 | On concrete work |
| 1099 | Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 1100 | Applying a coat of mordant solution on G.S.sheets: |
| 1101 | With a solution of 38gms of copper acetate in liter of soft water |
| 1102 | With a solution made of 13gms of hydrochloric acid in a solution of 13gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a liter of soft water. |
| 1103 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture over and including a priming coat of ready mixed zinc chromate yellow primer on new work. |
| 1104 | 75mmdiameter pipe |
| 1105 | 100mmdiameterpipe |
| 1106 | 150mmdiameterpipe |
| 1107 | Painting (two or more coats) on rain water, soil, waste andvent pipes and fittings with aluminumpaint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work. |
| 1108 | 75mm diameter pipe |
| 1109 | 100mm diameterpipe |
| 1110 | 150mm diameterpipe |
| 1111 | Painting (two or more coats) on rain water, soil, waste andvent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work : |
| 1112 | 100mm diameterpipe |
| 1113 | 150mm diameterpipe |
| 1114 | Paintingwithoiltypewoodpreservativeofapprovedbrandandmanufactureon Newwork(twoor morecoats) |
| 1115 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5sqm per liter per coat including preparation ofbasesurfaceas perrecommendations ofmanufacturertomakethesurfacefireretardant |
| 1116 | Coaltarringtwocoatsonnew workusing0.16literand0.12litercoaltarpersqminthe1stcoatand2ndcoatrespectively |
| 1117 | Wall Painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade.Two or more coats on new work |
| 1118 | Painting with synthetic enamel paint of approved brand and manufacture to give an evens shade. |
| 1119 | Twoormorecoatsonnewwork |
| 1120 | Two ormorecoatsonnew workoveran undercoatof suitable shade with ordinary paint of approved brand and manufacture. |
| 1121 | Paintingwithaluminumpaintofapprovedbrandandmanufacturetogivean even shade.Twoormorecoatsonnewwork |
| 1122 | Paintingwithacidproofpaintofapprovedbrandandmanufactureofrequiredcolour togivean even shade.Twoor morecoatsonnewwork |
| 1123 | Paintingwithblackanti-corrosivebitumasticpaintof approvedbrandandmanufacturetogiveanevenshadeonnewworkTwoormorecoats. |
| 1124 | Floor paintingwithfloorenamelpaintofapprovedbrand andmanufactureofrequiredcolourtogiveanevenshadeonnewworkTwoormorecoats. |
| 1125 | Varnishingwithvarnishofapprovedbrandandmanufacture: |
| 1126 | Twoormorecoatsofgluesizingwithcopalvarnish over and under coat of flatting varnish. |
| 1127 | Two or more coats of glue sizing with spar varnish on |
| 1128 | an under coat of flatting varnish |
| 1129 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture on New work |
| 1130 | Floorpolishingonmasonryorconcretefloorswithwaxpolishofapprovedbrandandmanufacture |
| 1131 | LetteringwithblackJapanpaintofapprovedbrandandmanufacture. |
| 1132 | Washed stone grit plaster on exterior walls of height upto 10 m above ground level in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per m2, top layer 15mm cement plaster 1:1/2 :2 (1 cement: 1/2 coarse sand : 2 stone chippings 10mm nominal size), in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specificationanddirectionofEngineer-in-charge(paymentforprovidinggroovesshallbemadeseparately). |
| 1133 | Forming groove of uniform size in the top layer of washed stonegritplaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : |
| 1134 | 15mm wideand15mmdeepgroove |
| 1135 | 20mm wideand15mmdeepgroove |
| 1136 | Extraforwashedgritplasteronexteriorwallsofheightmorethan10mgroundlevelforeveryadditionalheightof3morpartthereof |
| 1137 | Extraforwashedstonegritplasteroncircularworknotexceeding6minradius(intwocoats) |
| 1138 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approvedpattern, including providing and fixing aluminum channels of appropriate size andthickness (not less than 2mm),nailedtothe under layer with rust proofscrewsandnailsandfinishingthegroovecompleteasperspecificationsanddirectionoftheEngineerin-Charge. |
| 1139 | Extraforusingwhitecementinplaceofordinarycementinthetoplayeroftheitemofwashedstonegritplaster |
| 1140 | Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregatesasvermiculite/perliterespectivelyconformingtoIS: 2547(Part-1&II)1976,appliedonhacked/unevenbackgroundsuchasbarebrick/block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete. |
| 1141 | Extra for addition of synthetic Polyester triangular fibre of length 6 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125 gms. of synthetic Polyester triangular fibrefor50KgcementusedincementmortarasperdirectionsofEngineer-in-Charge. |
| 1142 | Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1143 | 1mm thick |
| 1144 | 2mm thick |
| 1145 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour. |
| 1146 | One coat |
| 1147 | Twocoats |
| 1148 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 1149 | One coat |
| 1150 | Twocoats |
| 1151 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 1152 | One coat |
| 1153 | Twocoats |
| 1154 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 1155 | Withreadymixedpinkor greyprimer onwoodwork(hardand soft wood) havingVOC content less than 50 grams/ liter |
| 1156 | Withreadymixedredoxidezincchromatic on steel /iron works having VOC content less than 250 grams/ liter |
| 1157 | Withwaterthinnablecementprimeronwallsurfacehaving VOCcontentlessthan50grams/liter |
| 1158 | Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives. |
| 1159 | Newwork(Twoor [email protected]/10sqm.Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 1160 | 6mmplasteroncementconcrete orreinforcedcementconcreteworkwith whitecementbasedpolymermodifiedselfcuringmortarofapproved make asper the direction of Engineer-In-Charge. |
| 1161 | Whitewashingwithlimetogiveanevenshade : |
| 1162 | 13.96.1 Oldwork(twoormorecoats) |
| 1163 | 13.96.2 Oldwork(oneormorecoats) |
| 1164 | Removingwhiteorcolourwashbyscrappingandsandpaperingand preparingthesurfacesmoothincludingnecessaryrepairstoscratchesetc.complete. |
| 1165 | Distemperingwithdrydistemperofapprovedbrandandmanufacture(oneormorecoats)andofrequiredshadeonoldworktogiveanevenshade. |
| 1166 | Removingdry oroilbound distemper,waterproofingcementpaintand thelikebyscrappingandsandpaperingandpreparingthesurfacesmoothincludingnecessaryrepairstoscratchesetc.complete. |
| 1167 | Painting onG.S.sheetwithsyntheticenamelpaintofapprovedbrandand manufacture of required colour togive an even shade on old work (one or more coats |
| 1168 | Painting(oneor morecoats)onrain water, soil, wasteandvent pipesand fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : |
| 1169 | 75mm diameter pipes |
| 1170 | 100mm diameterpipes |
| 1171 | 150mm diameterpipes |
| 1172 | Painting(twoor morecoats)onrainwater, soil, wasteandventpipesand fittings with aluminum paint of approved brand and manufacture over a primingcoat ofreadymixedzinc chromate yellowprimer onnewwork : |
| 1173 | 75mmdiameter pipes |
| 1174 | 100mmdiameterpipes |
| 1175 | 150mmdiameterpipes |
| 1176 | Painting (oneor morecoats) on rain water, soil, wasteandvent pipesand fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : |
| 1177 | 75mmdiameter pipes |
| 1178 | 100mmdiameterpipes |
| 1179 | 150mmdiameterpipes |
| 1180 | Painting with oil type wood preservative of approved brand andmanufacture on old work(one or more coats) |
| 1181 | Wallpaintingwithplasticemulsionpaintofapprovedbrandandmanufacturetogiveanevenshade,oneormorecoatsonoldwork. |
| 1182 | Painting with synthetic enamel paint of approved brand and manufacture of required colour togive an even shade,one or more coats on old work. |
| 1183 | Painting with aluminum paint of approved brand and manufacture to give an even shade,one or more coats on old work. |
| 1184 | Painting with acid proof paint of approved brand and manufacture of required colour togivean even shade,one or more coats on old work. |
| 1185 | Painting with black anti-corrosive bitum as tic paint of approved brand and manufacture to give an even shade,one or more coats on old work |
| 1186 | French spirit polishing, one or more coats on old work |
| 1187 | Polishing on wood work with readymade wax polish of approved brand and manufacture on old work. |
| 1188 | Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. |
| 1189 | Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : |
| 1190 | 32mm dia. |
| 1191 | 40mmdia. |
| 1192 | Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’specifications,one or more coats on old work |
| 1193 | Finishing walls with water proofing cement paint of required shade: |
| 1194 | Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @0.80liters/10sqm complete including cost of priming coat. |
| 1195 | Old work (one or more coats applied @2.20kg/10sqm) complete |
| 1196 | Finishing walls with textured exterior paint of required shade: |
| 1197 | Old work (two or more coats on existing cement paint surface applied @ 3.28 ltr/10sqm) |
| 1198 | Old work (one or more coats) applied @1.82ltr/10sqm |
| 1199 | Finishing walls with Acrylic smooth exterior paint of required shade: |
| 1200 | Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface) |
| 1201 | Old work (one or more coats applied @ 0.90 liters/10sqm) |
| 1202 | Finishing walls with premium Acrylic smoothexterior paint with silicon additives of required shade: |
| 1203 | Old work (Two or more coats applied @ 1.43 liters/ 10 sqm) over existing cement paint surface. |
| 1204 | Old work (one or more coats applied @0.83 liters/10sqm) |
| 1205 | Varnishing with varnish of approved brand and manufacture: |
| 1206 | One or more coats with copal varnish. |
| 1207 | One or more coats with spar varnish. |
| 1208 | Melamine polishing on wood work (one or more coats) |
| 1209 | Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work |
| 1210 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead:- With cement mortar 1:4(1cement:4 fine sand) |
| 1211 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead:-With cement mortar 1:4( 1 cement : 4 coarse sand) |
| 1212 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding holdfasts in cement concrete blocks of size 15x10x10cm with cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead:- Door chowkhats |
| 1213 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding holdfasts in cement concrete blocks of size15x10x10cm with cement concrete1:3:6(1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative tosides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meterslead:-Window chowkhats |
| 1214 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size15x10x10cm with cement concrete1:3:6(1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative tosides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meterslead:-Clerestory window chowkhats |
| 1215 | Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/chemical fasteners of appropriate size (3 nos on each vertical member of door chowkh at sand 2 nos.one each vertical member of window chowkhats), including cost of dash fasteners/chemical fasteners. |
| 1216 | Making the opening for door/window/clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. |
| 1217 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty :- Float glass panes of thickness 4.0mm (weight not less than 10kg / sqm) |
| 1218 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty :- Float glass panes of thickness 5.0 mm(weight not less than 12.5 kg/sqm) |
| 1219 | Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0mm (weight not less than 10kg/sqm) |
| 1220 | Renewing glass panes, with wooden fillets wherever necessary :Float glass panes of thickness 5.0mm (weight not less than 12.5 kg/sqm) |
| 1221 | Renewing glass panes and re-fixing existing wooden fillets:- Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 1222 | Renewing glass panes and re-fixing existing wooden fillets:-14.8.2 Float glass panes of thickness 5.0 mm (weight not less than 12.5 kg/sqm) |
| 1223 | Supplying and fixing new wooden fillets wherever necessary :- 2nd class teak wood fillets |
| 1224 | Supplying and fixing new wooden fillets wherever necessary :- Hollock wood fillets |
| 1225 | Fixing old glass panes with wooden fillets (excluding cost of fillets) |
| 1226 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, and cleaning, refilling the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 1227 | Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to dumping ground all complete as per directions of Engineer-in-Charge:- Sal wood battens |
| 1228 | Renewing wooden beams in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to dumping ground within 50 meters lead :- Not exceeding 4.00 meters in length.:- Salwood beams |
| 1229 | Renewing wooden beams in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to dumping ground within 50 meters lead :- Not exceeding 4.00 meters in length:- Hollock wood beams |
| 1230 | Renewing wooden beams in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to dumping ground within 50 meters lead :- Above 4.00 meters and upto 5.00 meters length.:- Sal wood beams |
| 1231 | Renewing wooden beams in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to dumping ground within 50 meters lead :- Above 4.00 meters and upto 5.00 meters length.:- Hollock wood beams |
| 1232 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or re-plastering, including disposal of rubbish to the dumping ground within 50 meters lead. |
| 1233 | Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. |
| 1234 | Fixing of old wind ties with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacture over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. |
| 1235 | Renewing bottom rail and / or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer: |
| 1236 | Renewing Wrought Iron or M.S. Wheel or roller of steel door or gate and fittingand fixing thesame with necessaryclamps,nutsand bolts / welding and erection etc. complete.:-Wheel 50 mm dia. And below |
| 1237 | Renewing Wrought Iron or M.S. Wheel or roller of steel door or gate and fittingand fixing thesame with necessaryclamps,nutsand bolts / welding and erection etc. complete.: Wheel above 50 mmdia. |
| 1238 | Providing and fixing 25mm thick shutters for cupboard etc, including nickel plated bright finished M.S. piano hinges with necessary screws.:- Paneled or paneled and glazed shutters:-1st class teak wood |
| 1239 | Providing and fixing 25mm thick shutters for cupboard etc, including nickel plated bright finished M.S. piano hinges with necessary screws.:- Glazed shutters:- Ist class teak wood |
| 1240 | Providing and fixing plain jaffri door and window shutters including bright or / and black enameled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50 x12 mm beading complete with Secondclassteakwood |
| 1241 | Providing and fixing brass curtain rods of wall thickness1.25mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.:- 20 mm diameter. |
| 1242 | Providing and fixing brass curtain rods of wall thickness1.25mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.:- 25 mm diameter. |
| 1243 | Providing and fixing M.S. round or square bars at required spacing in wooden frame of windows and clerestory windows. |
| 1244 | Providing joist (karries) including hoisting, fixing in position and applying wood preservative on unexposed surface etc. complete with :- Salwood |
| 1245 | Providing joist (karries) including hoisting, fixing in position and applying wood preservative on unexposed surface etc. complete with :- Hollackwood |
| 1246 | Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete :-150mm |
| 1247 | Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete :-125mm |
| 1248 | Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete :-100mm |
| 1249 | Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete :-150mm |
| 1250 | Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete :-125mm |
| 1251 | Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete :-100mm |
| 1252 | Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete :-250mm |
| 1253 | Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete :-150 mm |
| 1254 | Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete :-100 mm |
| 1255 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 1256 | Providing and fixing bright finished brass hard drawn hooks and eyes300 mm |
| 1257 | Providing and fixing bright finished brass hard drawn hooks and eyes 250 mm |
| 1258 | Providing and fixing bright finished brass hard drawn hooks and eyes 200 mm |
| 1259 | Providing and fixing bright finished brass hard drawn hooks and eyes 150 mm |
| 1260 | Providing and fixing bright finished brass hard drawn hooks and eyes 100 mm |
| 1261 | Providing and fixing bright finished brass fan light pivot with necessary brass screws etc. complete. |
| 1262 | Providing and fixing 300 mm long bright finished brass chain with hook for fan light catch including necessary brass screws etc. complete. |
| 1263 | Providing and fixing bright finished brass quadrant stay 300mm long with necessary brass screws etc. complete. |
| 1264 | Providing and fixing chromium plated brass butt hinges with necessary brass screws etc. complete. 125x70x4 mm (ordinary type) |
| 1265 | Providing and fixing chromium plated brass butt hinges with necessary brass screws etc. complete. 100x70x4 mm (ordinary type) |
| 1266 | Providing and fixing chromium plated brass butt hinges with necessary brass screws etc. complete. 75x65x4 mm (heavy type) |
| 1267 | Providing and fixing chromium plated brass butt hinges with necessary brass screws etc. complete.-75x40x2.5 mm (ordinary type) |
| 1268 | Providing and fixing chromium plated brass butt hinges with necessary brass screws etc. complete.-50x40x2.5 mm (ordinary type) |
| 1269 | Providing and fixing 85x42mm chromium plated brass pull bolt lock with necessary C.P. brass screws, nuts, bolts and washers etc. complete |
| 1270 | Providing and fixing double scaffolding system (cup lock type) on the exteriorside,up tosevenstorey heightmadewith40mmdiaM.S.tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directionsand approval of Engineer-in-charge. The elevational area of thescaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 1271 | Providing and fixing bright finished brass casement window fasteners or peg stays to windows/ventilators with necessary welding and machine screws etc. complete. |
| 1272 | Providing and fixing 14 mm bright finished brass spring catch to steel centre hung ventilators with necessary welding and machine screws etc.complete. |
| 1273 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 1274 | Cleaning of terrace/loft water storage tank (inside surface area) upto2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date isnot removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 1275 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 1276 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and de- chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia up to 300 mm |
| 1277 | Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as perdirection of Engineer-in-Charge. |
| 1278 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace includingshifting at ground level as per direction of Engineer-in- charge. |
| 1279 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm |
| 1280 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm |
| 1281 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS- 12818 and making good the same etc.completeasper direction of Engineer-in-charge. |
| 1282 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 1283 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 1284 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.:- InternalWork-Exposedon wall |
| 1285 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 1286 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in- charge:-1:3:6 or richer mix (i/c equivalent design mix) |
| 1287 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in- charge:1:4:8 or leaner mix (i/c equivalent design mix) |
| 1288 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 1289 | Demolishing R.B work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 1290 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 1291 | R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 1292 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In mud mortar |
| 1293 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In lime mortar with old mughal bricks |
| 1294 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In limemortar |
| 1295 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In cement mortar |
| 1296 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) :-From brick work in mud mortar |
| 1297 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) :- From brick work in lime mortar |
| 1298 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) :-From brick work in cement mortar |
| 1299 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:-In lime mortar |
| 1300 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In cement mortar |
| 1301 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:-In lime mortar |
| 1302 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:-In cement mortar |
| 1303 | Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured):-In lime mortar |
| 1304 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :- Of area of 3 sqm. and below |
| 1305 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :-Of area beyond 3 sqm. |
| 1306 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :-Of area of 3 sqm. and below |
| 1307 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :-Of area beyond 3 sqm. |
| 1308 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 1309 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead :-Of sectional area below 40 sqcm. |
| 1310 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one meter or part thereof beyond 10 meters :-Of sectional area 40 sqcm and above. |
| 1311 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one meter or part thereof beyond 10 meters :- Of sectional area below 40 sqcm. |
| 1312 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one meter or part thereof beyond 5 meters :-Of sectional area 40 sqcm. and above. |
| 1313 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one meter or part thereof beyond 5 meters :- Of sectional area below 40 sqcm. |
| 1314 | Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in :-R.S. Joists |
| 1315 | Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in :-Channels, angles, tees and flats |
| 1316 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc.including dismembering and stacking within 50 meters lead. |
| 1317 | Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge: |
| 1318 | Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one meter or part thereof beyond 10 meters. |
| 1319 | Extras for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one meter or part thereof beyond 5 meters. |
| 1320 | Extra for marking of structural steel work required to be re-erected. |
| 1321 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.:-For thicknessoftiles10mmto25mm |
| 1322 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.:- For thicknessoftilesabove25mmandupto40mm. |
| 1323 | Demolishing dry brick pitching in floors,drainsetc.including stacking serviceable material and disposal of unserviceable material within 50 meters lead. |
| 1324 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within50 meters lead. |
| 1325 | Dismantling roofing including ridges, hips valleys and gutters etc.,and stacking the material within 50 meters lead of :- G.S. Sheet |
| 1326 | Dismantling roofing including ridges, hips valleys and gutters etc.,and stacking the material within 50 meters lead of :-Asbestossheet |
| 1327 | Dismantling jack arch roofing and floors including stacking of serviceablematerial and disposal of unserviceable material within 50meters lead. |
| 1328 | Dismantling tiled roofing with battens boardingetc.complete includingstacking of serviceable material and disposal of unserviceable material within 50 meters lead |
| 1329 | Dismantling wooden ballies in posts and struts including stacking within 50 meters lead. |
| 1330 | Dismantling and stacking within 50 meters lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of TorLironorpipe |
| 1331 | Dismantling and stacking within 50 meters lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of R.C.C. |
| 1332 | Cutting ballies or wooden posts of fencing at the point of projection abovethe concrete or ground and stacking the same within 50 meters lead. |
| 1333 | Dismantling barbed wire or flexible wire rope in fencing including makingrolls and stacking within 50 meters lead. |
| 1334 | Dismantling wooden trellis work excluding frames but including stackingthe serviceable material within 50 meters lead. |
| 1335 | Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 meters lead. |
| 1336 | Dismantling wooden boardingsin lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead :- Upto10 mm thick |
| 1337 | Dismantling wooden boardingsin lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead :- Thickness above 10 mm upto25mm |
| 1338 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead :-Thickness above 25 mm upto 40mm. |
| 1339 | Dismantling precast concrete or stone slabs in walls ,partition walls etc. including stacking within 50 meters lead:- Thickness upto 40 mm |
| 1340 | Dismantling precast concrete or stone slabs in walls ,partition walls etc. including stacking within 50 meters lead:-Thickness above 40 mm upto 75 mm |
| 1341 | Dismantling cement asbestos or other hardboard ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 meters lead. |
| 1342 | Dismantling C.I. or asbestos rain water pipes with fittings and clamps including stacking the material within 50 meters lead :-75 to 80 mm dia pipe. |
| 1343 | Dismantling C.I. or asbestos rain water pipes with fittings and clamps including stacking the material within 50 meters lead :-100 mm dia pipe. |
| 1344 | Dismantling C.I. or asbestos rain water pipes with fittings and clamps including stacking the material within 50 meters lead :- 150 mm dia pipe. |
| 1345 | Dismantling manually/ mechanically including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:-Water bound macadam road. |
| 1346 | Dismantling manually/ mechanically including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- Bituminous road. |
| 1347 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge :-15 mm to 40 mm nominal bore. |
| 1348 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge :- Above 40 mm nominal bore |
| 1349 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:-Including excavation and refilling trenches after taking out the pipes.:- Upto 150 mm diameter. |
| 1350 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:-Including excavation and refilling trenches after taking out the pipes.:-Above 150 mm diaupto 300 mm dia. |
| 1351 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:-Including excavation and refilling trenches after taking out the pipes.:-Above 300 mm diameter. |
| 1352 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:- Excluding excavation and refilling trenches after taking out the pipes.:- Upto 150 mm diameter. |
| 1353 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:- Excluding excavation and refilling trenches after taking out the pipes.:- Above 150 mm diaupto 300 mm dia. |
| 1354 | Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer- in-charge.:- Excluding excavation and refilling trenches after taking out the pipes.:- Above 300 mm diameter. |
| 1355 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 meters lead as per direction of Engineer-in-charge : |
| 1356 | Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 meters lead. |
| 1357 | Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 meters lead including refilling the excavated gap. |
| 1358 | Dismantling of flushing cistern of all types(C.I/PVC/Vitreous china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 meters lead |
| 1359 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 1360 | Dismantling aluminum / Gypsum partitions, doors, windows, fixedglazing and false ceiling including disposal of unserviceable surplus materialand stacking of serviceable material within 50meters lead as directed by Engineer-in-charge. |
| 1361 | Demolishing RCCwork by mechanical means & stock-piling at designated locations & disposal of dismantled materials upto a lead of 1 kilometer, stacking serviceable & unserviceable material separatelyincluding cutting reinforcement bars |
| 1362 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometer ,as perdirectionofEngineer-in-charge. |
| 1363 | Supplying at site R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge (cost of earth works in excavation, concrete works in foundation to be paid separately). |
| 1364 | Supplying at site Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). |
| 1365 | Supplying and fixing turn buckles and straining bolts for barbed wire fencing. each |
| 1366 | Fencingwith R.C.C.postplacedatrequireddistance,embeddedin cement concrete blocks, every 15th post, last but one end post and corner postshall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 meters (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):-Payment to be mad per meter cost of total length of barbed wire used.:- With G.I.barbedwire. |
| 1367 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per meter cost of total length of barbed wire used.:-With G.I. barbed wire |
| 1368 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. |
| 1369 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge.:- Made of G.I. wire of dia 4 mm |
| 1370 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge.:-16.25.2 Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade. |
| 1371 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 1372 | Engraving letters in hard stone |
| 1373 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 1374 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. |
| 1375 | Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.:-100x100x16 mm |
| 1376 | Providing and laying matt finished vitrified tile of specified size having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge.:-300x300x9.8 mm |
| 1377 | Excavating holes upto 0.10 cum, including getting out the excavated soil, then returning the soil as deported in layers not exceeding 20 cm in depth, including consolidating and deposited layer by ramming watering etc., disposing of surplus excavated soil as directed with in a lead of 50 mm and lift upto 1.5 m.:-All kind of soil |
| 1378 | Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment) |
| 1379 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation |
| 1380 | Fine dressing of the ground |
| 1381 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.):- In rows 5 cm apart in either direction |
| 1382 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.):- In rows 7.5 cm apart in either direction |
| 1383 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.):- In rows 15 cm apart in either direction |
| 1384 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.):- with grass turf |
| 1385 | Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing & disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid separately.) |
| 1386 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts |
| 1387 | Providing and fixing M.S. flat iron tree guard 60 cm dia. and 2 m high above ground level formed of 4 nos. 25x6 mm, 2.25m long and 8 nos. 25x3 mm 2 m long vertical M.S. flats riveted to 3 nos.25x6 mm MS flat iron rings in two halves, fixed together at site with required 6 no. of 8 mm dia. and 30 mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/PWD/any other approved name The tree guard shall be suitably fixed to the ground by embedding four legs of the tree guard in pits of suitable dia. and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction on direction of Officer-in-charge |
| 1388 | Making tree guard 53 cm dia & 1.3 m high as per design from empty coal tar drums supplied free by the department including providing and fixing two nos. MS sheet rings 50x0.5mm with rivets complete in all respects including painting inside and outside of tree guard with :-A coat of coal tar. |
| 1389 | Making tree guard 53 cm dia & 1.3 m high as per design from empty coal tar drums supplied free by the department including providing and fixing two nos. MS sheet rings 50x0.5mm with rivets complete in all respects including painting inside and outside of tree guard with :-Two or more coats of ready mixed synthetic enamel paint of approved quality and shade over a priming coat. |
| 1390 | Making tree guard 53 cm dia& 2.0 m high as per design from empty coal tar drums supplied free by the department including providing and fixing 4 legs 40 cm long of 30x3 mm MS flat riveted to tree guard & providing and fixing two nos. MS sheet rings 50x0.5mm with rivets complete in all respects including painting inside and outside of tree guard with:- A coat of coal tar. |
| 1391 | Making tree guard 53 cm dia& 2.0 m high as per design from empty coal tar drums supplied free by the department including providing and fixing 4 legs 40 cm long of 30x3 mm MS flat riveted to tree guard & providing and fixing two nos. MS sheet rings 50x0.5mm with rivets complete in all respects including painting inside and outside of tree guard with :- Two or more coats of ready mixed synthetic enamel paint of approved quality & shade over a priming coat. |
| 1392 | Providing and fixing M.S tree guard 45 cm square in plan, height 1.20 meter above ground level and 0.40 meter below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical members shall be welded to 4 nos. 25x6 mm M.S flats placed horizontally around the vertical members of the cage. One name plate of 1 mm thick M.S sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD /PWD/any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two more coats of synthetic enamel paint of approved brand and or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer complete in all respect. |
| 1393 | Providing and fixing M.S tree guard 50 cm square in plan, height 1.40 meter above ground level and 0.50 meter below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x5 mm, 1.9 m long, one at each corner and 8 nos flat iron of size 25x5 mm, 1.4 m long. The vertical members shall be welded to 4 nos. 25x6 mm M.S flats placed horizontally around the vertical members of the cage. One name plate of 1 mm thick M.S sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/PWD/any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer complete in all respect. |
| 1394 | Preparation of mounds of various size and shape by available excavated/supplied earth in layers not exceeding20 cm in depth, breaking clods, watering of each layer dressing etc. lead upto 50 meter and lift upto 1.5 m complete as per direction of officer- in -charge |
| 1395 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100 mm diameter |
| 1396 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150 mm diameter |
| 1397 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.200 mm diameter |
| 1398 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.230 mm diameter |
| 1399 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 250 mm diameter |
| 1400 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 300 mm diameter |
| 1401 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-All around S.W. pipe :- 100 mm diameter S.W. pipe |
| 1402 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-All around S.W. pipe :- 150 mm diameter S.W. pipe |
| 1403 | roviding and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-All around S.W. pipe :- 200 mm diameter S.W. pipe |
| 1404 | roviding and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-All around S.W. pipe :- 230 mm diameter S.W. pipe |
| 1405 | roviding and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-All around S.W. pipe :- 250 mm diameter S.W. pipe |
| 1406 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.-Upto haunches of S.W. pipe 100 mm diameter S.W. pipe |
| 1407 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.- 150 mm diameter S.W. pipe |
| 1408 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.- 200 mm diameter S.W. pipe |
| 1409 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.- 230 mm diameter S.W. pipe |
| 1410 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.- 250 mm diameter S.W. pipe |
| 1411 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.- 300 mm diameter S.W. pipe |
| 1412 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.:- 100 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1413 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 100 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 1414 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1415 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 1416 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1417 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.:-180 x 150 mm size P type With Sewer bricks conforming to IS : 4885 |
| 1418 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-100 mm diameter |
| 1419 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-150 mm diameter |
| 1420 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-200 mm diameter |
| 1421 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-230 mm diameter |
| 1422 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-250 mm diameter |
| 1423 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-300 mm diameter. |
| 1424 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-350 mm diameter |
| 1425 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-400 mm diameter |
| 1426 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :-450 mm diameter |
| 1427 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 100 mm dia. R.C.C. pipe |
| 1428 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 150 mm dia. R.C.C. pipe |
| 1429 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 250 mm dia. R.C.C. pipe |
| 1430 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 300 mm dia. R.C.C. pipe |
| 1431 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 450 mm dia. R.C.C. pipe |
| 1432 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 500 mm dia. R.C.C. pipe |
| 1433 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 600 mm dia. R.C.C. pipe |
| 1434 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 700 mm dia. R.C.C. pipe |
| 1435 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 800 mm dia. R.C.C. pipe |
| 1436 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 900 mm dia. R.C.C. pipe |
| 1437 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 1000 mm dia. R.C.C. pipe |
| 1438 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 1100 mm dia. R.C.C. pipe |
| 1439 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:- 1200 mm dia. R.C.C. pipe |
| 1440 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 450 mm dia. R.C.C. pipe |
| 1441 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 600 mm dia. R.C.C. pipe |
| 1442 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 900 mm dia. R.C.C. pipe |
| 1443 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 1000 mm dia. R.C.C. pipe |
| 1444 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 1200 mm dia. R.C.C. pipe |
| 1445 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class (Medium duty) R.C.C. pipes - 1800 mm dia. R.C.C. pipe |
| 1446 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class ( Heavy duty) R.C.C. pipes - 450 mm dia. R.C.C. pipe |
| 1447 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class ( Heavy duty) R.C.C. pipes - 600 mm dia. R.C.C. pipe |
| 1448 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class ( Heavy duty) R.C.C. pipes - 900 mm dia. R.C.C. pipe |
| 1449 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class ( Heavy duty) R.C.C. pipes - 1000 mm dia. R.C.C. pipe |
| 1450 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-3 class ( Heavy duty) R.C.C. pipes - 1200 mm dia. R.C.C. pipe |
| 1451 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. Complete :- Non-pressure NP-4 class ( Heavy duty) R.C.C. pipes - 1800 mm dia. R.C.C. pipe |
| 1452 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :- Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :- With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1453 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :-Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :- With Sewer bricks conforming to IS : 4885 |
| 1454 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :- Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :- With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1455 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :-Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :- With Sewer bricks conforming to IS : 4885 |
| 1456 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :-Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1457 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :- -Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- With Sewer bricks conforming to IS : 4885 |
| 1458 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :- Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :- With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 1459 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :- Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :-With Sewer bricks conforming to IS : 4885 |
| 1460 | Extra for depth for manholes Size 90x80 cm:- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1461 | Extra for depth for manholes Size 90x80 cm :- With Sewer bricks conforming to IS : 4885 |
| 1462 | Extra for depth for manholes Size 120 x 90 cm:- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1463 | Extra for depth for manholes Size 120x 90 cm :- With Sewer bricks conforming to IS : 4885 |
| 1464 | Supplying and fixing C.I. cover without frame for manholes:- 455 x 610mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 1465 | Supplying and fixing C.I. cover without frame for manholes:- 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. |
| 1466 | Supplying and fixing C.I. cover without frame for manholes:- 560 mm diameter C.I. cover ( heavy duty) the weight of the cover to be not less than 108 kg |
| 1467 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 2.5 :- Rectangular shape 600x450 internal dimensions. |
| 1468 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 2.5 :- Square shape 450mm internal dimensions |
| 1469 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 2.5 :- Circular shape 450mm internal diameter |
| 1470 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 10 :- Square shape 450 mm internal dimensions |
| 1471 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 10 :- Circular shape 500mm internal diameter |
| 1472 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 20 :- Circular shape 560 mm internal diameter |
| 1473 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 35 :- Circular shape 560 mm internal diameter |
| 1474 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg |
| 1475 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :- For pipes 100 to 250 mm diameter |
| 1476 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :- For pipes 250 to 300 mm diameter. |
| 1477 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :- For pipes 350 to 450 mm diameter |
| 1478 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately).:- Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 |
| 1479 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately).:-Rectangular manhole 120x90 cm with circularcover 500 mm dia of grade MD - 10 |
| 1480 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately).:-Rectangular manhole 120x90 cm with circularcover 560 mm dia of grade HD - 20 |
| 1481 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately).:- Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 |
| 1482 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :- Inside dimensions 455x610 mm and 45 cm deep for single pipe line. |
| 1483 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :-Inside dimensions 500x700 mm and 45 cm deep for single pipe line with one or two inlets. |
| 1484 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :-Inside dimensions 600x850 mm and 45 cm deep for singlepipe line with three or more inlets. |
| 1485 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion :- |
| 1486 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion :- |
| 1487 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion :- |
| 1488 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) :- For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) :- Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 1489 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.):- Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 1490 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.):- Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) |
| 1491 | Providing and fixing 12mm thick prelaminated particle board flatpressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge.:- Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 1492 | Providing and fixing 12mm thick prelaminated particle board flatpressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge. Pre laminated particle board with decorative lamination on both sides. |
| 1493 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.):-With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 1494 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.):- With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 1495 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.):- With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm) |
| 1496 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- plate etc. complete as per the direction of Engineer-in-charge.:-With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 1497 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- plate etc. complete as per the direction of Engineer-in-charge.:- With brass cover plate minimum 1.25 mm thickness |
| 1498 | Providing and fixing powder coated aluminium work (minimum thickness ofpowder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall withstainless steel rawl plugs @ 450 mm centre to centre and fixing theframe work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paidfor separately). |
| 1499 | Providing and fixing 6mm dia. G.I level adjusting hangers (upto 1200 mm length) fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3mm size 60mm long and stainless steel expandable dash fasteners 12.5 mm dia. 50mm long complete as per direction of Engineer-in-charge |
| 1500 | Providing and fixing machine moulded aluminum covering of approved pattern & design, made out of machine-cut aluminum sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceilings floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastner of 8 mm dia. and 75 mm long bolt including providing aluminum washers 2mm thick, 15mm dia. at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. as per drawing and direction of Engineer in-charge :- Anodized aluminum sheet 2.5 mm thick (Anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 1501 | Providing and fixing machine moulded aluminum covering of approved pattern & design, made out of machine-cut aluminum sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceilings floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastner of 8 mm dia. and 75 mm long bolt including providing aluminum washers 2mm thick, 15mm dia. at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. as per drawing and direction of Engineer in-charge Powder coated aluminum sheet 2.5 mm thick (minimum thickness of powder coating 50 micron). |
| 1502 | Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.:- Upto 5mm depth and 5mm width. |
| 1503 | Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminum extruded sections. Forfixedportions |
| 1504 | Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminum extruded sections. Shutters of doors, windows and ventilators |
| 1505 | Providing and fixing double glazed hermetically sealed glazing in aluminum windows, ventilators and partition etc. with 6mm thick clear float glass both side having 12mm air gap including providing EPDM gasket, perforated aluminum spacers, desiccants, silicon sealant (both primary and secondary sealant )etc.as per specifications ,drawings and directions of Engineer-in-chargecomplete. |
| 1506 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 205 x 19 mm |
| 1507 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 225 x 19mm |
| 1508 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 355 x 19 mm |
| 1509 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 510 x 19 mm |
| 1510 | Providing &fixing stainless steel (SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 710 x 19 mm |
| 1511 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100 mm long with SS screw etc. complete as per direction of Engineer-in-charge. Anodized (AC 15) aluminum tubular handle bar. |
| 1512 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100 mm long with SS screw etc. complete as per direction of Engineer-in-charge:- Powder coated minimum thickness 50 micron aluminum tabular handle bar. |
| 1513 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100 mm long with SS screw etc. complete as per direction of Engineer-in-charge.:-Polyester powder coated minimum thickness 50 micron aluminum tubular handle bar. |
| 1514 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc.complete. |
| 1515 | Providingand fixing Anodizedaluminum (Anodizedtransparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) sub frame work for windows and ventilators withextruded built up standard tubular sections of approved make conforming to IS:733 and IS:1285 fixed with dash fastener of required dia and size(dash fastener to be paid separately). |
| 1516 | Providing and fixing aluminum casement windows fastner of required length for aluminum windows with necessary screws etc. Complete |
| 1517 | Anodized (AC15) aluminum |
| 1518 | Powder coated minimum thickness 50micron aluminum |
| 1519 | Polyester powder coated minimum thickness 50microns aluminum |
| 1520 | Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge |
| 1521 | Anodized (AC15) aluminum |
| 1522 | Powder coated minimum thickness 50micron aluminum |
| 1523 | Polyester powder coated minimum thickness 50microns aluminum |
| 1524 | Providing and fixing Anodized aluminum grill (Anodized transparent or dyed torequired shadeaccording toIS: 1868minimumanodiccoating of Grade AC 15) of approved design/pattern, with approved standardsection andfixed tothe existingwindows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(only weight of grill to be measured for payment) |
| 1525 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top& bottom pivot &double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle,lock and stopper etc.to be paid separately). |
| 1526 | Providing and fixing 12mm thick frameless toughened glass of approved brand and manufacture all complete as per directions of Engineer Incharge at site |
| 1527 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sage lastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer- in- charge complete,complying to ASTMC920, DIN18540-F&ISO11600 |
| 1528 | Upto5mmdepthand5mmwidth |
| 1529 | Upto10mmdepth and10mmwidth |
| 1530 | Upto20 mmdepthand20mmwidth . |
| 1531 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures as directed by Engineer-in-Charge and consisting of :i) 1st layer of 22 mm to 25 mm thick approved and specified roughstone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.ii) 2nd layer of 25mm thick cement mortar 1:3 (1cement: 3coarsesand) mixed with waterproofing compound in recommended proportions.iii) Finishing top with stone aggregate of 10 mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone. |
| 1532 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with waterproofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm(minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with waterproofing compound and finishing the exterior of stone slab with cement mortar 1:3(1cement: 3coarse sand) 20mm thick with neat cement punning mixed with waterproofing compound in recommended proportion complete at all levels and as directed by Engineer-in-Charge.Using rough kota stone. |
| 1533 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & thelike consisting of:(i) Ist course of applying cement slurry@ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrdcourseofapplyingblown orresidual bitumenappliedhot at1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other withbitumen @ 1.7 kg/sqm). |
| 1534 | Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire beforepouring concrete etc. complete. |
| 1535 | Serrated with central bulb (225mm wide, 8-11mm thick) |
| 1536 | Dumb bell with central bulb (180mm wide,8mm thick) |
| 1537 | Kickers(320mm wide, 5mmthick) |
| 1538 | Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @0.126kg/sqm.This layer will be allowed to air cure for 4hours followed with water curing for 48 hours.The rate includes preparation of surface,treatment and sealing of all joints,corners,junctions of pipes and masonry with polymer mixed slurry. |
| 1539 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) [email protected] kg/sqm mixed with water proofing cement compound @ 0.670 kg./sqm. and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours.The entiretreatment will be taken upto30cm on parapet wall and tucked into groove in parapet all around.(d) fourth andfinal layer of brick tiling with cement mortar (which will be paid for separately)For the purpose of measurement the entire treated surface will be measured. |
| 1540 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface beforetreatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining wallsupto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishingthe surface with 20mm thick joint less cementmortar ofmix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operationstobe donein orderandas directed andspecified byEngineer- in- charge.23.7.1With average thickness of 120mm and minimum thickness at khurra as 65mm |
| 1541 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25or90/15conformingtoIS 702 applied hot @ 1.45 kg/sqm of area for each course, second course of roofing felt type 3 grade-I (Hessian based self finished bitumen felt) and fourth & final course of stone grit6mm & down size or pea-sized gravel spread at 6 cubic decimeters per square metre including preparation of surface but excluding grading complete with Bitumen felt (Hessian based) type 3grade I conforming to Is:1322 |
| 1542 | Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. |
| 1543 | Grading roof for water proofing treatment with :- Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 1544 | Grading roof for water proofing treatment with:- Cement mortar 1:3 (1cement : 3 Coarse sand) |
| 1545 | Grading roof for water proofing treatment with:- Cement mortar 1:4 (1cement : 4 Coarse sand) |
| 1546 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges,min4-point cremonelocking sets with stainlesssteel plates,handles,buffersetc.including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings ,as per the approved shop drawings,as specified and as directed by the Engineer -in- Charge. |
| 1547 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, inlinear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm / sqm, made of randomly oriented glass fibres distributed in a binder by a wet-layprocess including fixing1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SSrivets, nuts, bolts, washers etc complete. |
| 1548 | Providing and supplying Spandrel Glass Panels comprising of 6 mmthick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc.,all complete for the required performances as specified, asper the Architectural drawings, as per the approved shop drawings, as specified, and asdirected by the Engineer-in-Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position,shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item*).(i)Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to35 %, Light reflection internal 10 to15%,lightreflection external 10 to 20%, shading coefficient (0.25-0.28) and Uvalue of 3.0 to 3.3 W/m2 degree K etc.The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 1549 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS-316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings.The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at theperimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 1550 | Providing and fixing of superior quality accessories for toughened glass enclosures including Carriage of all materials from approved sources up to site of work completed. Stainless steel L Connection |
| 1551 | Providing and fixing of superior quality accessories for toughened glass enclosures including Carriage of all materials from approved sources up to site of work completed Wheel Set (1 Pair) |
| 1552 | Providing and fixing of superior quality accessories for toughened glass enclosures including Carriage of all materials from approved sources up to site of work completed Steel Rod including steel channel |
| 1553 | Providing and fixing of superior quality accessories for toughened glass enclosures including Carriage of all materials from approved sources up to site of work completed Fixed Rod |
| 1554 | Providing and fixing of superior quality accessories for toughened glass enclosures including Carriage of all materials from approved sources up to site of work completed Door Seal |
| 1555 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm Dia wire and 1.4 mm wide aperture with matching wood beading including Carriage of all materials from approved sources up to site of work completed |
| 1556 | Providing and laying Pre Laminated Scratch proof water resistant HDF Wooden Purgo flooring (AC 4) in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Including all carriages complete as specified and as directed by the Engineer-in-Charge. 8mm thick |
| 1557 | Providing and fixing of plywood in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge..6mm |
| 1558 | Providing and fixing of plywood in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge.. 10mm |
| 1559 | Providing and fixing of plywood in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge.. 12mm |
| 1560 | Providing and fixing of plywood in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge.. 18mm |
| 1561 | Providing and fixing of plywood (BWR) in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge.. 6mm |
| 1562 | Providing and fixing of plywood (BWR) in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge 10mm |
| 1563 | Providing and fixing of plywood (BWR) in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge 12mm |
| 1564 | Providing and fixing of plywood (BWR) in walls, ceiling or like of approved brand and manufacture with all necessary fittings and fixtures, scoldings all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge 18mm |
| 1565 | Providing and fixing of HDF(AC 4type) wooden flooring approved brand and quality sample to be got approved by engineer in charge at site over 4 to 6mm thick PVC Thermocoal base including providing and fixing of matching imported wooden cornice beading for edges with necessary fitting and fixture etc including all carriage complete as per direction of engineer in charge at site |
| 1566 | Providing and fixing of MDFC Beading / profile / Angle /Cornice of desired colour and pattern and match as all complete as specified and as directed by the Engineer-in-Charge including all carriages complete as specified and as directed by the Engineer-in-Charge.. |
| 1567 | Designing, Fabricating, testing, Installation and fixing of Alumni Composite panels (ACP) of Alstone, Eurobond or E.g. in wall cladding, Ceiling (4 mm thick with 0.5 mm thick skin thickness) over and Including the frame work of Alumimum Sections of 16 gauge of required length with necessary fittings like Screws, Dash Fasteners, silicon and scaffolding etc all carriages complete as per directions of in charge engineer at site |
| 1568 | Designing, Fabricating, testing, Installation and fixing of Alumni Composite panels (ACP) coloured of Alstone, Eurobond or E.g. in wall cladding, Ceiling (4 mm thick with 0.5 mm thick skin thickness) over and Including the frame work of Alumimum Sections of 16 gauge of required length with necessary fittings like Screws, Dash Fasteners, silicon and scaffolding etc all carriages complete as per directions of in charge engineer at site |
| 1569 | Providing and fixing ply wood of good quality in Rough ceilings and at all places including cost of nails, adhesives and scaffolding etc complete and partitions including priming and painting (two coats) of including fixing of 1st class KD wood base work wherever required and all carriages involved 12mm |
| 1570 | Providing and fixing ply wood of good quality in Rough ceilings and at all places including cost of nails, adhesives and scaffolding etc complete and partitions including priming and painting (two coats) of including fixing of 1st class KD wood base work wherever required and all carriages involved 8mm |
| 1571 | Providing and fixing ply wood of good quality in Rough ceilings and at all places including cost of nails, adhesives and scaffolding etc complete and partitions including priming and painting (two coats) of including fixing of 1st class KD wood base work wherever required and all carriages involved 6mm |
| 1572 | Providing and fixing of Corrugated Panelled Boarding GI Sheets 0.15 mm Thick of approved brand, design and colour over and including 2\\" x 1.5\\" jams of KD wood, plyboard 12mm where ever required with all necessary fittings and fixtures including scaffolding, swings. Ladders etc and dismantling of previous soffit all complete as per the directions of incharege engineer |
| 1573 | Providing and fixing of Aluminium Foil Bubble Insulation Sheet, Thickness 12mm Neo Insulation Material is made of Single or Double layers of polyethylene industrialized air bubbles bonded between two layers of highly reflective pure aluminium foil film.• Industrialized strength, lightweight yet durable insulation designed to hold staples without tearing.• Does not compress, collapse or disintegrate. Reflects 97% of radiant heat, emits less than 3% of heat, Class 1 / Class A fire rated radiant barrier that has passed the ASTM E84 test & ASTM E2599.• Non-toxic, non-carcinogenic, fibre-free, safe to handle and does not require protective clothing or respirators to install including 50x40mm wooden frame work. |
| 1574 | Providing and fixing of imported PVC panelling of approved make and pattern including base work of GI channels with necessary screw and cornice at the edge with all the carriage complete as per the direction of EIC at site |
| 1575 | Providing and fixing of HDF(AC 4type) scratch proof laminated panelling fixed on walls of approved brand and quality sample to be got approved by engineer in charge at site over required size of ply board including all carriage (the measurement of ply shall be paid seperately) excluding angle and corns (of approved brand and make as directed by EIC |
| 1576 | Providing wood work in frames of false ceiling, partitions trusses etc sawan and fixed in position with necessary fitting and fixture all carriages involved complete as per direction of IES (Popular wood ) |
| 1577 | Painting with synthetic enamel paint Deco (Berger Jivan) of approved brand and manufacture with one or more coat of approved Wood primer to give an even shade of Two or more coats on old as well as new work mechanically including scrapping on the old existing paint with all procedures etc. including all carriages and up to floor V |
| 1578 | Providing and Fixing of PVC side knobs Chromium plated fancy type of approved colour and make including all carriages and up to floor V |
| 1579 | Providing and Fixing of Table Top Glass of approved make and quality including providing smooth edging etccompleteincluding all carriages and up to floor V 8mm thick |
| 1580 | Providing and Fixing of Table Top Glass of approved make and quality including providing smooth edging etccompleteincluding all carriages and up to floor V 12mm thick |
| 1581 | Engagement of carpenter workers for easing of doors / Windows and other Carpentry works along with machines, cutters, grinders, tools , generator and other necessary required equipment's including carriages too and for for doing necessary repairs all complete as per the directions Carpenter |
| 1582 | Engagement of workers for repairing tiles, plaster, brick work or any other construction work along with machines, cutters, grinders, tools , and other necessary required equipment's including carriages too and for for doing necessary repairs all complete as per the directions Meson |
| 1583 | Mason for Tile repairing |
| 1584 | Helper |
| 1585 | Engagement of painter for painting wood work or any other construction work along with tools , and other necessary required equipment's including carriages too and for for doing necessary repairs all complete as per the directions Painter |
| 1586 | Providing and fixing of Bamboo wooden flooring 17 mm thick with necessary filling,foametc all complete as per the direction ofEngineer-in- charge. |
| 1587 | Providing and fixing of Blinders for door/windows openings with imported fabric including cost of Aluaminiumchannel, operating system etc all complete as per the direction of Engineer-in-charge.:-Zebra Blind |
| 1588 | Providing and fixing of Blinders for door/windows openings with imported fabric including cost of Aluaminiumchannel, operating system etc all complete as per the direction of Engineer-in-charge.:-Roller Blind |
| 1589 | Providing and fixing of Blinders for door/windows openings with imported fabric including cost of Aluaminiumchannel, operating system etc all complete as per the direction of Engineer-in-charge.:-Vertical Blinds |
| 1590 | Providing and fixing of windows Awnings DICKSON ACRYLIC/POLYSTER fabric basket window Awnings having sunrays protection ,rain & wind proof striped out words curve shaped.etc all complete as per the direction of Engineer-in-charge |
| 1591 | Providing and fixing of retractable Awnings for door/window sunshades stripped ACRYLIC/POLYSTER make water and wind proof including all fittings etc all complete as per the direction of Engineer-in-charge. |
| 1592 | Providing and fixing of hard wooden cornice 3/4inches ( 20mm) for floorings and penallingsetc all complete as per the direction of Engineer-in- charge. |
| 1593 | Providing and fixing of 20mm cornice imported all complete as per the direction of Engineer-in-charge. |
| 1594 | Providing and fixing of T-profile for door/window joints in flooring,penelling etc. all complete as per the direction of Engineer-in-charge. |
| 1595 | Providing and fixing of 40mm jumbo channel Aluminium made for curtains windows,door including cost of screws etc.all complete as per the direction of Engineer-in-charge. |
| 1596 | Providing and fixing of 40mm PVC channel for curtains windows, door, curtain holders, etc including cost of screws etc.all complete as per the direction of Engineer-in-charge. |
| 1597 | Providing and fixing of aluminium grill/mesh decorative type approved by incharge engineer (anodised)with aperture of 50x50mm of 16 gauge with all necessary fittings like nuts bolts washers including scaffolding upto 22m allcomplete as per directions. |
| 1598 | Providing and Fixing of Door Closer of approved make and quality :-Pump type |
| 1599 | Providing and Fixing of Door Closer of approved make and quality:-Capsule type |
| 1600 | Providing and Fixing of Door Closer of approved make and quality:-Hydraulic type |
| 1601 | Providing and Fixing of Almira locks with screws complete of approvedmake and quality such as Link/ Godrej |
| 1602 | Providing and Fixing of brass fittings superior of approved make andquality:-Handle 150mm Long |
| 1603 | Providing and Fixing of brass fittings superior of approved make andquality:-Hanger plate stainless steel 450mm long |
| 1604 | Providing and Fixing of brass fittings superior of approved make andquality:-Hanger hook cromium plated single type |
| 1605 | Providing and Fixing of brass fittings superior of approved make andquality:-Hanger hook cromium plated Double type |
| 1606 | Providing and Fixing of mortice lock for doors link / Godrej make |
| 1607 | Providing and Fixing of pad lock of link / Godrej make:-(65mm) |
| 1608 | Providing and Fixing of pad lock of link / Godrej make:- above 65mm |
| 1609 | Providing and Fixing of PVC side knobs Cromium plated fancy type of approved color and make |
| 1610 | Providing and fixing of rubber strip nosing for stair steps fixed with adhasive including removing of old damaged strips (If any including sandpapering and cleaning the surface) |
| 1611 | Providing and fixing of Aluminium strip nosing for stair steps fixed with adhasive including removing of old damaged strips (If any including sandpapering and cleaning the surface (size 37.5x37.50mm) |
| 1612 | Providing and fixing of anti slip/skid tape high traction abrasive tape (1.17 mm thick and above) for slippery floors ,stair case,ramps,indore andoutdoors with all charges complete. |
| 1613 | Engagement of black smith along with welding machines, generator and other necessary required equipments including carriages too and fro for doing necessary repairs all complete as per the directions. |
| 1614 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.A. 8 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from naturalgypsum as per IS 2095 part-I and laminated with white 0.16mm thick fireretardant PVC film on the face side and 12micron metalized polyester onthe back side with all edges sealed with the face side PVCfilm which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile acompletely sealed unit. |
| 1615 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.B. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from naturalgypsum as per IS 2095 part-I and laminated with white 0.16mm thick fireretardant PVC film on the face side and 12micron metalized polyester onthe back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile acompletely sealed unit. |
| 1616 | Providing and fixing of imported wooden panelling lining on walls, ceilings tongued and grooved planks including cost of ground work of 12mm to 10mm (as per requirement) thick ply 50mm wide 600mm*600mm center to center harizontally and vertically fixing with rawl plugs and screws and cover mouldings but including cost of nails, screws and scafolding etc. including cost of two coats of touch wood and 50mm wide wooden cornice etc. complete (12mm thick) |
| 1617 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick (BWR)ply wood in sides, shelves and front shutters and back with 6mm thick (BWR) ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of primer and painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-600mm |
| 1618 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick (BWR)ply wood in sides, shelves and front shutters and back with 6mm thick (BWR) ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of primer and painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-450mm |
| 1619 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick (BWR)ply wood in sides, shelves and front shutters and back with 6mm thick (BWR) ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of primer and painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-300 mm |
| 1620 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick ply wood in sides, shelves and front shutters and back with 6mm thick ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of wood primer painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-600mm |
| 1621 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick ply wood in sides, shelves and front shutters and back with 6mm thick ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of wood primer painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-450mm |
| 1622 | Providing and fixing of Kitchen cabinets / Amirah made of 19 mm thick ply wood in sides, shelves and front shutters and back with 6mm thick ply wood including lining of front shutters with sun-mica or teak wood mirror polished as per approved drawings icluding one coat of wood primer painting two or more coats of synthetic enamel paint of approved quality and color inside including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages:-300 mm |
| 1623 | Providing and fixing of denmica /Sunmica over old almira or like of approved quality, design and color including all Brass hardware fittings,glazing and drawer telescopic channels etc. wherever required & locking arrangements (As per the directions of EIC) all inclusive complete job.(Face area of the cabinet will be measured for payment) including all carriages |
| 1624 | Providing and Fixing of ornamental stair posts (Surrya) Bren Wood design to be approved by EIC) with necessary fittings and macchinesetc including carriages complete as per the directions by EIC |
| 1625 | Providing and Fixing of ornamental ornamental King posts (Surrya) Bren Wood design to be approved by EIC) with necessary fittings and macchinesetc including carriages complete as per the directions by EIC |
| 1626 | providing and Fixing of ornamental railing (Surrya) Bren Wood design to be approved by EIC) with necessary fittings and macchinesetc including carriages complete as per the directions by EIC |
| 1627 | Providing and Fixing Prelaminated HD , AC IV of approved brand , of planks 8 mm thick on walls & floors including cost of supporting member as of 5mm, foam layer for floor and supporting members and frame work to support plank like runners 2\\" x 1.5\\" @ 600 mm centrerocentrehortizontally and vertically where ever required as directed by EIC fixing with rawal plugsand screws , jams , studs , plyboards 12 mm @ 600 mm etc in level and plum to be measured in fitted and finished form colour and patter as approved by competent authority & ENGINEER INCHARGE . excluding angle and cornice( OF APPROVED BRAND AND MAKE AS DIRECTED EIC). |
| 1628 | Providing and Fixing of MDFC Beadings , cornices , profile's of desired/ matching colour with the Planks whehere ever required AS DIRECTED BY ENGINEER INCHARGE . A complete job. |
| 1629 | Providing and Fixing of MDFC, cornices , profile's of desired/ matching colour with the Planks whehere ever required AS DIRECTED BY ENGINEER INCHARGE . A complete job. |
| 1630 | Providing and Fixing of FANCY PVC LINING ON WALLS CEILING TOUNGED AND GROOVED INCLUDING COST OF GROUND WORK OF ALUMINIUM 50 MM WIDE 600MM C/C HORZINTOLLY AND VERTICALLY, INCLUDING SCREWS FITTING AND SCAFFOLDING. INCUDING EDGE BEADING, CORNICES , PROFILES A COMPLETE JOB AS DIRECTED BY ENGINEER INCHARGE . A complete job. |
| 1631 | Providing and fixing plained eaves boarding of coloured G.S Sheet of required size 300mm wide x 0.5mm thick as directed by Engineer Incharge. |
| 1632 | Providing and fixing pre- color coated galvanized iron high rib sheets / tile profile (size, shape and pitch of corrugation as approved by Engineer-in- charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required(to be placed vertically). |
| 1633 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275gram/m2 |
| 1634 | Providing and fixing pre- colour coated corrigatedgalvanised steel sheet for fencing in horizontal/ vertical / curved position 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. |
| 1635 | Providing and fixing 35 thick panell door with 6 to 8 panells of 35 mm thick WOOD , with desired profile and pattern as aproved by competant authority including fixing with butt hinges of required size with necessary screws,with ALL FITTINGS AND FASTNINGS LIKE ornamental HANDLE, TOWER BOLTS 230etc of , 35 mm thick K.D Wood in door frame as well as in panells .PENELS INCLUDED As per the direction of Engineer Incharge. Including French spirit polishing, Two or more coats on new works including a coat of wood filler and make base a complete job |
| 1636 | Providing and fixing 35 mm thick paneled door shutters, including ISI marked black enameled M.S. butt hinges with necessary screws including paneling of 12mm thick decorative Nova pan Particle board both sides laminated as per the approved design complete with required beading/moldings. (styles and rails shall be of standard size) First. Class K.D/Silver wood. |
| 1637 | Providing and fixing 35 mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI markedM.S. pressed butt hinges bright finished of required size with necessary screws . Including two or more coats of synthetic enamel paint with one of coat of wood primer, |
| 1638 | Providing and fixing glazed shutters 35 mm thick for doors, windows and clerestory windows using 3.5 mm thick float glass panes including ISI markedM.S. pressed butt hinges bright finished of required size with necessary screw with ALL FITTINGS AND FASTNINGS LIKE HANDLE, TOWER BOLT100 mm etc . Including two or more coats of synthetic enamel paint with one of coat of wood primer, of K.D Wood including all hardware fittings. |
| 1639 | Providing and fixing Corrugated ColourPanelled Boarding of G.I Sheets 0.125 mm thick of approveed make design , pattern and colour as directed by Engineer Incharge for the soffits etc over 2\\"x1.5 \\" jams , ply board 12 mm where ever required, Including Cost of Nails , Scaffolding redquired , Ladders, ropes and other safteyequipments with Dismantling of previous Soffits making good , a complete job what so ever. UPTO A HEIGHT A 30 M |
| 1640 | Providing and fixing of 6 mm thick ply for Almirah s , INCLUDING CARRIAGE |
| 1641 | Providing and fixing 19 mm thick ply board in level and plum of approved brand . Where Ever reqd as directed by EIC.including the cost of hinges,wooden beading and other hardware fitting |
| 1642 | Providing and fixing of 12 mm thick ply for Almirah including the cost of hinges,wooden beading and other hardware fittings , INCLUDING CARRIAGE |
| 1643 | Providing and fixing of Dulmica/ sunmica sheeting including cost of nails and adhesive complete at all places and as lamination to wardrobes etc.. 1 MM |
| 1644 | Providing and fixing of TEAK sheeting including cost of nails and adhesive complete at all places and as lamination to wardrobes etc.. |
| 1645 | Polishing on wood work with touch wood polish (One or more coats) including preparing of surface by cleaning and sand papering. |
| 1646 | Clearance of debris / Mulba by mechanically or by manually including accumulation at diffirent spots including its disposal out sideMuncipal limits which includes all loading and unloading complete. |
| 1647 | Engagment of TATA MOBILE for disposal of dismantled material out of the MuncipleLimts along with loading and un loading of material . |
| 1648 | Providing and Fixing of Acrylic iluminted Signages 2D Board of rectangular Shape: ( size 15''x 7'') having Thickness of Board 3 mm with Vinyle Lettering including wooden frame box,saver lamp and wiring all necessary items by way of chiseling of plaster for fixing the same on gate piller .Complete Job |
| 1649 | Providing and fixing of fixing retro reflective signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, and fixing the same to the wallls of building plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts. Including scaffolding upto 30m . a complete job |
| 1650 | Providing and fixing of letters of various sizes on Roll of Honour Board including cost of material , carriage to &fro board . |
| 1651 | Providing and fixing of 8mm thick itching glass including cost of required beading etc. |
| 1652 | Providing and fixing specified board medium density exterior grade (Grade I) to frame, backing or studding with screws etc. including all carriages and up to Floor V all complete (Frames, backing or studding to be paid separately) Pre•laminated with decorative lamination on ONE SIDE MDF board conforming to IS:14587. 8 MM THICK |
| 1653 | UPVC CORRUGATED GUTTER Horizontal 160 mm wide , 110 mm deep , standard outlet 90 mm , capacity 16 Ltr/ Mtr ,with Leaf Guard , along with all accessories sch as runners , runner drop, elbow, stop end , inner bracket PVC, Stop end drop, Elbows of all angle, colour white, UPVC Bracket with steel extension , steel clamps GI 160 / UPVC BRACKS as per requirements of make Aquastar or equivalent . InCLUDING SCAFFOLDING UPTO 30 M |
| 1654 | UPVC CORRUGATED C SQUARE Down pipes of standard size 90 mm x 60 mm , of capacity 6 Ltr/ mtr , colour white GUTTER , with fitting and fastenings spacing @ 900 mm c / c , anchored properly in level and plum all accessories such as elbow, stop end , inner bracket PVC, , Elbows of all angle, UPVC Bracket with steel extension , steel clamps GI 160mm / UPVC BRACKS as per requirementsof make Aquastar or equivalent |
| 1655 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately).KD Wood. |
| 1656 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position:- Budloo / Fir wood. |
| 1657 | Providing and fixing of superior quality wall paper of approved brand, manufacture, color and design with necessary adhesive Gum powder fully chemicalised or favicol whichever is suitable including prepration of wall surface by way of sand papering, applying of POP/wall putty and other necessary repair , all complete at all heights as per specifications, drawings and as directed by Engineer In-charge etc. |
| 1658 | Providing and fixing of wooden moulded cornice of required size (base and height) of traingular shape to the junction of panelling etc with iron screws , plugs and priming coat on unexposed surface etc complete. KD wood. |
| 1659 | Providing and fixing Ist quality ceramic glazed wall tiles (Digital Series) conforming to IS : 13753 (thickness to be specified by the manufacturer or minimum thickness 5mm), of approved make like AGL, NITCO,ORIENT, SOMANY, KAJARIA, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade upto floor V level complete. |
| 1660 | Providing and fixing Ist quality ceramic glazed floor tiles (Digital Series and Anti skid) conforming to IS : 13753 (thickness to be specified by the manufacturer or minimum thickness 5mm), of approved make like AGL, NITCO,ORIENT, SOMANY, KAJARIA, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- inCharge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade upto floor V level complete. |
| 1661 | Dismantling of old damaged tiles and cement plaster and like from walls including ranking out joints including disposal of malba outside municipal limits as directed by Engineer Incharge at site. |
| 1662 | Providing and fixing of chromium plated utensil basket for kitchen cupboards |
| 1663 | Providing and fixing of HDF(AC 4type) scratch proof laminated panelling fixed on walls of approved brand and quality sample to be got approved by engineer in charge at site over required size of ply board including all carriage (the measurement of ply shall be paid seperately) |
| 1664 | Engagement of JCB for clearance of site as per the directions of Engineer Incharge at site complete. |
| 1665 | Providing and fixing of alumunium hardware fittings of standard quality and of required size. |
| 1666 | Al Drop |
| 1667 | Handles 150mm |
| 1668 | Handles 100mm |
| 1669 | Butt Hinges |
| 1670 | Raising / Repairing main hole cover and frames slab to required level incld dismantling existing slab and making good the damage as required in brick masonary incld cement plaster 1:4 complete incld disposal of unserviceable material beyond the municipal limits as directed by Engineer Incharge on site. |
| 1671 | 1' x 1' x 1' |
| 1672 | 1'-6'' x 1'-6'' x 1'-6'' |
| 1673 | 2'-0'' x 2'-0'' x 1'-6'' |
| 1674 | Providing and fixing of fiber sheet to the existing door shutters all complete as per the directions of Engineer Incharge at site. |
| 1675 | Providing and fixing polycarbonated 4mm transparent as per requirement and as desired by Engineer Incharge incld fixing of same by screws complete job. |
| 1676 | Providing and fixing acrylic vinyl board of room of hounour alongwith framing of the same with frame beading of requisite shape and pattern with complete fitting mechanism and fixing of the same at desired locations incld all carriage complete. |
| 1677 | Providing and fixing acrylic vinyl board of room of hounour alongwith framing of the same with frame beading of requisite shape and pattern with complete fitting mechanism and fixing of the same at desired locations incld all carriage complete. |
| 1678 | Providing and fixing of double action heavy duty hinge from high quality steel long lasting with self closure mechanisim with double action for swing door of approved make and quality. |
| 1679 | Providing and fixing bright matt finished stainless steel handles of approved quality and make with necessary screws etc all complete. 100mm. |
| 1680 | Providing and fixing aluminium hardware fittings of approved make and quality, Al drop with lock (300mm) of make Godrej / link approved by EIC. |
| 1681 | P/F nominal rubber wood panelling on walls comprising frames, panels and moulding of approved design and thickness 19mm fixed over wooden battens as reuired , incld cutting, shapping, plaining, jointing, nailing / screwing all labour and material complete job incld surface preparation as directed by EIC. |
| 1682 | P/F rubber wood 19mm for window casing or architrave of approved section fixed to window jams/ reveals / frame lining incld cutting fitting screws/ nails adhesieve and finishing with polishing / melamine complete job. |
| 1683 | P/F of nominal rubber wooden 19mm thick beeding (2\\") incld cutting , moulding and sand papering, cutting , placing complete job. |
| 1684 | P/F nominal rubber wood panelling on walls comprising frames, panels and moulding of approved design and thickness 6mm fixed over wooden battens as required , incld cutting, shapping, plaining, jointing, nailing / screwing all labour and material complete job incld surface preparation as directed by EIC. |
| 1685 | Providing and fixing glass panes with wooden fittings of required size wherever necessary glass panes 3.5mm thick weighing 8.75 Kg/ Sqm |
| 1686 | Providing and fixing coat hook as per the directions of Engineer Incharge at site. |
| 1687 | Providing and laying of good earth in layers not exceeding 15 cm in depth incld all watering, levelling , ramming etc and carriage all complete as per the directions of Engineer Incharge. |
| 1688 | Providing wood work of false ceiling, partitions trusses etc sawan and fixed in position with necessary fittings and fixture all carrages involved complete as per direction of Engineer incharge (KD wood) |
| 1689 | Providing and fixing of wood work in trusses, purlins, rafters complete in Ist Class KD wood with all costs & carriages complete upto the site of work as directed by Engineer incharge |
| 1690 | Providing and fixing of plain jaffery of 35x10mm placed 35mm apart with frames to be paidn separately including fixing 50x12mm beading complete with Ist class KD wood including two or more coats of synthetic enamel paint over one coat of wood primer |
| 1691 | Carriage of material by mechanical transport from source upto site of work. |
| 1692 | Sand,. Stone aggregate below 40mm nominal size. (15 Kms) |
| 1693 | Earth (20 Km) |
| 1694 | Bricks (20 Kms) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail