| 1 | DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5Sq mm FRLS PVC insulated copper conductor single core cable and 1.5Sq mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group A |
| 3 | DSR item No.1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 4 | 3 Module |
| 5 | 4 Module |
| 6 | 6 Module |
| 7 | 8 Module |
| 8 | DSR item No.1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 amps switch |
| 11 | 3 Pin 5/6 A. socket outlet |
| 12 | 15/16 amps switch |
| 13 | 6 Pin 15/16 A. socket outlet |
| 14 | DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 15 | DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 16 | 25 mm |
| 17 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 18 | 3 x 1.5 sq. mm |
| 19 | 3 x 2.5 sq. mm |
| 20 | DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 21 | DSR item no. 8.6.10LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 9 of the DNIT) |
| 22 | 36 watt |
| 23 | DSR item no.8.9.5 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 10 of the DNIT) |
| 24 | 18- 22 watt |
| 25 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 11 of the DNIT) |
| 26 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 380-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 27 | Supply and erection of 14 GMS sheet frame of suitable size for erection of exhaust fan. The hole should be suitable required size for exhaust fan shall be cut from the Centre of the sheet duly fixed on existing M.S. glazing/ ventilator. (As per Complete Item No. 13 of the DNIT) |
| 28 | Suitable for 12” / 15” / 18” Exhaust Fan. |
| 29 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 13 of the DNIT) |
| 30 | DSR item no.8.16.3LED Flood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, (As per Complete Item No. 14 of the DNIT) |
| 31 | 100 watt Please Enable Macros to View BoQ information |